Chihiros Smart Dosing Pump User Manual
- June 9, 2024
- Chihiros
Table of Contents
Chihiros Smart Dosing Pump
Package Contents
Naming
Enter the name of supplements
Priming
Priming fills the dosing tube with the supplement from the container to the
tip of the dosing tube. Make sure that the supplement is at the end of the
outlet dosing tube before proceeding to the calibration. The head can be
primed by pressing “Long press to priming” / “Stop” priming buttons in the
App.
Calibration
The instructions in the App will guide you through a simple calibration
process using the laboratory grade measuring cylinder provided with the unit.
Make sure that the measuring cylinder is clean and dry before each measurement
as any drops left inside will affect the accuracy of the reading.Due to the
physical properties of liquids the surface of the liquid inside a measuring
cylinder is flat in the middle but rise slightly at the sides. The correct
measurement is at the center (lower part) of the surface and not the sides.
The measuring cylinder has printed graduations every 0.1ml however you should
estimate the volume to the nearest Inlet Outlet 0.05ml which is half way
between the printed graduations.
Always hold the tip of the dosing tube at the center of the cylinder so that
the drops do not stick to the cylinder walls.
During the calibration process the doses a predetermined number of rotations
of the dosing head that should give a volume of between 3 and 4ml. Once you
enter the exact volume into the App it will give a confirmation dose of
exactly 4ml so that you can confirm that the calibration was done correctly.
The confirmation dose should be between 3.95 and 4.05ml. If not, you will be
guided to repeat the calibration process again.
Scheduling Automatic Dosing Schedule
A selection dosing schedules can be set to run for each head on a regular
daily basis, or on selected days of the week. Additional manual doses can be
added at any time and without disrupting an automated schedule. The schedule
can also be switched on and off as required, without losing your settings.
Single dose, Hourly dose and Custom Periods dose schedules are based on a
desired total daily dose (total amount of supplement that should be dosed per
day) for each head. The schedule will divide the total daily dose volume
equally between the total number (1-24) doses per day, so that you can easily
update your daily dose volume anytime. Individual doses may vary by up to 1
drop throughout the day to ensure the single drop accuracy for the complete
daily dose. The total daily dose per head can be from 0.2ml up to 999.9ml in
increments of 0.1ml, however the smallest individual dose is limited to 0.2ml.
You can change the total daily dose or the number of doses whenever
desired.Dose will automatically recalculate the dosing schedule for the rest
of the day and if necessary will present you with options regarding how to
proceed. For example.If you increase your daily dose in the middle of the day,
but have already run some doses at that point, but still have some doses to
run, the My Chihiros app will prompt you to make a one-off compensation by
adding the added dose to the remaining doses for the day and start running
your new schedule the next day.
The effective time of all automatic scheduling settings, set up on the same day, if dose has not been run today, all schedules are executed immediately on this day, if the set up schedule has been run, and reset the setting, there are 2 cases, the update schedule is less than the previous schedule dose amount. will not running today, and the new schedule is executed the next day; if the update schedule dose volume is more than the previous one, App will be reminded whether the amount of the new schedule setting on the same day minus the amount already dosed in this day, dose the left in all at once, or you can cancel dose today, new schedule is executed starting the next day.
Run Delay
To prevent individual additives reacting with each other, if you switch on the run delay function, each channel will be added after a certain interval of 30 seconds and if two heads are scheduled to be set at exactly the same time, the head on the left will take precedence. The run delay function is only used for automatic scheduling and is not available manual mode.
Single dose
Your daily dose will be given in one portion, once a day.
- Select the “Single dose” option.
- Press on “Single dose” to set the total daily dose, the specific time that you wish the dose to be given, and your dosing rote.
- Press “Save” to implement the new schedule settings and return to the Head Settings page.
Recurrence (days of week)
Select “Daily” if you want your schedule to run seven days a week. This is the
default setting.
Select “Select days” if you wish your schedule to run on specific days of the
week. The selection can be updated at any time.
Manual Dosing
Manual Dosing enables you to dose a specific volume on-demand at any time
without affecting the automatic dosing schedule and is available even when the
schedule is turned Off.
The volume of Manual Doses given today is displayed separately from the
automatically scheduled doses in both the Homepage and the Dashboard.
Supplement Volume Monitor
The “Supplement Volume Monitor” automatically deducts the amount of supplement dosed (scheduled and manual) from the last updated volume of supplement in the container. MY CHIHIROS app shows the number of days left in the container that can be used for dosing based on the current schedule. By default, the Supplement Volume Monitor will notify you three days before your supplement runs out.
Missed dose compensation
Automated doses may miss their scheduled times due to external circumstances such as a power outage.When the ‘missed dose compensation function’ is enabled, all missed doses for the day (after 0:00 midnight) will be compensated once the doses is back in normal operation mode. If you disable this function,dose will not be rescheduled if they are not run on time(This feature will not take effect until the battery is installed).
Power-off memory
After installing a CR2032 button battery, it can ensure that the clock is accurate, the program is normal, and the settings will not be lost in the event of a power failure (the battery needs to be purchased separately).
FCC Warning Statement
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
– Reorient or relocate the receiving antenna.
– – Increase the separation between the equipment and receiver.
– – Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– – Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
The device has been evaluated to meet general RF exposure requirement.
Thanks for purchasing Chihiro’s products, please read this manual carefully
before use.
This device requires an App to be used on your phone. Please download and
install it as follows.
For Android
Please GET IT ON Google Play and search for “MyChihiros” to install.
For iOS
Please Download on the App Store and search for “My Chihiros” to install.
Safety Tip: To avoid electric shock, be careful when working with an
aquarium already in water. When the equipment fails, please do not attempt to
repair it yourself. You should follow the instructions of the after-sales
personnel or send the faulty equipment to an authorized repair place or
discard the faulty equipment. To prevent injury, the following basic safety
precautions should be followed:
–Do not use this product if any part of the connecting cable or power adapter
is damaged, the device malfunctions or is dropped. Damaged parts must be
replaced before reuse. Please use original Chihiro parts. Using third-party
accessories may lead to unsafe conditions.
–The power plug should always be within easy reach so that the power can be
turned off immediately in the event of an emergency failure after
installation.
–Children or individuals with reduced physical, mental, sensory abilities or
lack of experience or knowledge, please use this product under the supervision
and guidance of adults; do not let children touch this product without
supervision, and do not allow children to clean or carry out maintain. Close
supervision is required when children use or have children that may come into
contact with the device.
–To avoid injury, do not touch moving parts. When removing or placing the
device, please unplug it first. Also unplug the device when it is not in use
or before cleaning. Do not pull out the plug by pulling on the power cord. The
correct way to do this is to hold the plug and pull it out to disconnect.
–Do not use this product for any purpose other than its purpose.
–This device is only for indoor use, do not use the device in the open air or
in an environment where the temperature is below 0° C.
–Before operating, make sure the device is securely installed.
–Do not dispose of this product as ordinary household garbage, but take it to
the local garbage collection station.
— Read and follow all important notes about the device.
Note: Care should be taken to arrange the cord so that it cannot be tripped over or pulled accidentally.
Specifications
Number of dosing heads | 4 |
---|---|
Dose flow | > 50ml/min |
BPT lifetime | 2e1000H |
Dimensions | 17.7 x 5.4 x 4.2cm(7.0″ x 2.2″ x 1.7″) |
Operating Temperature | 5 to 45° C |
Relative Humidity | 15-85%RH |
Supply voltage | 100-240V 50/60Hz |
Operating Voltage | DC12V |