Mendip M00530-00-00-00-02 Woodland DC SE Multi Fuel Wood Burning Stove Instruction Manual
- June 9, 2024
- Mendip
Table of Contents
OPERATION AND INSTALLATION MANUAL
MULTI-FUEL & SMOKE EXEMPTION MODELS
THE WOODLAND DUAL CONTROL
The Woodland DC SE – M00530-00-00-00-02
The Woodland DC Logstore SE – M00531-00-00-00-02
The Woodland DC Logstore Convector Plus SE – M00533-00-00-00-01
The Woodland DC Convector Plus SE – M00534-00-00-00-01
Dimensions
WOODLAND DC STOVE DIMENSIONS
WOODLAND DC CONVECTOR PLUS STOVE DIMENSIONS
The direct air intake spigot (80mm diameter) to the rear of the stove is
removable with a 2.5mm Allen key.
WOODLAND DC LOGSTORE CONVECTOR PLUS STOVE DIMENSIONS
The additional, top flue rear convection panel (supplied loose within the
stove) needs to be used when installing the stove 100mm from a combustible
wall; this slots over the rear convection panel and provides additional
radiant protection from the flue collar.
The direct air intake spigot (80mm diameter) to the rear of the stove is
removable with a 2.5mm Allen key.
The SE appliances include a modified air control to prevent closure of the
secondary air control beyond 25% open**
Installation Instructions
MENDIP STOVES WARRANTY
5 Year Extended Warranty
If you have purchased your stove from a Mendip Stoves registered retailer,
then your stove will carry a 2 year warranty as standard. The 2 year warranty
can be further extended to a total warranty period of 5 years by registering
your Mendip Stove within one month of the latter of the purchase date or
installation date. Accordingly, the start date for the warranty period is the
date of purchase. During the registration process, the Registered Retailer
details will be required for your Extended Warranty to be activated. Any
product purchased outside of our registered Retailer Network will carry a
standard 12 month, non-extendable warranty. It is a condition of the Extended
Warranty that the installation complies with the relevant Building Regulations
and is carried out by a suitably trained and qualified individual (HETAS in
the UK or equivalent in other countries) with the certificate of installation
and proof of purchase supplied. Full terms and conditions are detailed in the
Warranty Statement on the Euro stove website www.eurostove.co.uk. In the event
of any conflict of information the wording on the website shall prevail.
Important Note: Should any problems be experienced with your product, claims
must first be submitted to the Retailer where the appliance was purchased from
who will offer immediate assistance or contact Euro stove on your behalf.
Register online today to activate warranty: online.
http://www.mendipstoves.co.uk/SIT/StoveRegistration
INSTALLATION MANUAL
This manual refers to the stoves listed above, which are tested in accordance
with EN 13240.
Thank you for purchasing your new stove from Mendip Stoves. Please read this
manual carefully to ensure that you get maximum enjoyment and performance from
your new stove and to prevent any potential operational problems. Please note
that “all local regulations, including those referring to national and
European Standards, need to be complied with when installing this appliance”.
For further information on installing and using fireplaces and wood burning
stoves, please see the relevant building regulations.
These instructions cover the basic principals to ensure the satisfactory
installation of your multi-fuel stove, although detail may need slight
modification to suit particular local site conditions.
HEALTH AND SAFETY PRECAUTIONS
INFORMATION FOR THE USER, INSTALLER AND SERVICE ENGINEER
Special care must be taken when installing a stove such that the requirements
of the Health & Safety at Work Act are met.
Handling
Adequate facilities must be available for loading, unloading and site
handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into
contact with the skin. In case of contact wash immediately with plenty of
water.
PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating
appliance. There must not be an extractor fan fitted in the same room as the
stove because this can cause the stove to emit fumes into the room.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any
asbestos in the coarse of installation then please seek specialist guidance
and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the
possibility of personal injury.
CO Alarms:
Building regulations require that whenever a new or replacement fixed solid
fuel or wood/biomass appliance is installed in a dwelling a carbon monoxide
alarm must be fitted in the same room as the appliance. Further guidance on
the installation of the carbon monoxide alarm is available in BS EN 50292:2002
and from the alarm manufacturer’s instructions.
Provision of an alarm must not be considered a substitute for either
installing the appliance correctly or ensuring regular servicing and
maintenance of the appliance and chimney system.
Stove paint Aerosols
Paint aerosols are flammable and therefore dangerous to use around a lit
stove. Be sure to allow aerosols spray paints to dry and ventilate the room
well before lighting the stove. The use of any aerosol around lit stove is
dangerous and care must be take in handling aerosols.
Fireguards: The use a fireguard to BS 8423:2002 in the presence of
children, aged and/or infirm persons is essential for their safety, even when
the stove is not in use.
The glass on the stove is ceramic glass and able to withstand very high
temperatures however it is not toughened and a hard impact could cause the
glass to break.
IMPORTANT:
These instructions cover the basic principles to ensure the satisfactory
installation of Mendip Stoves product :- Woodland models, although detail may
need slight modification to suit particular local site.
In all cases the installation must comply with current Building Regulations,
Local Authority Byelaws and other specifications or regulations as they affect
the installation of the stove. It should be noted that the Building
Regulations requirements may be met by adopting the relevant recommendations
given in British Standards BS 8303, BS EN 15287 as an alternative means to
achieve an equivalent level of performance to that obtained following the
guidance given in Approved Document J.
FLUE & CHIMNEY CONNECTION TO STOVE
The outlet from the chimney should be above the roof of the building in
accordance with the provisions of Building Regulations Approved Document J. If
installation is into an existing chimney then it must be sound and have no
cracks or other faults which might allow fumes into the house. Older
properties, especially, may have chimney faults or the cross section may be
too large .
Mendip Stoves recommend the use of a solid fuel flue lining system for all
installation into existing chimneys. All chimney systems must be used in
accordance with Building Regulations Approved Document J.
If an existing chimney is used the chimney must be clear of obstruction and be
swept clean immediately before installaiton of the stove. The chimney should
be tested to confirm the chimney will provide the correct chimney pressure for
the stove. If the stove is fitted in place of an open fire the chimney should
be swept one month after installation to clear any soot falls which may have
occurred due to the difference in combustion between the stove and the open
fire. If there is no existing chimney then either a prefabricated block
chimney in accordance with Building Regulations Approved Document J or a twin
walled insulated stainless steel flue to BS 1856-1 . These chimneys must be
fitted in accordance with the manufacturer’s instructions and Building
Regulations. A single wall metal flue pipe is suitable for connecting the
stove to the chimney but is not suitable for using for the complete chimney.
The connecting flue pipe must have a minimum diameter of 125 mm and its
dimension should be not less than the size of the outlet socket of the stove.
Registered smoke exempt models with a 125mm collar burning wood only can be
installed on a flue of 125mm throughout. Any bend in the chimney or connecting
flue pipe should not exceed 45º. 90º bends should not be used other than
within 150mm of stove rear flue outlet.
Chimney Connection
In order for the stove to perform satisfactorily the chimney height must be
sufficient to ensure an adequate draught to clear the products of combustion
and prevent smoke problems into the room.
Tested Gas flow rates flue gas temperatures| Flue gas flow rate Wood /
smokeless briquetted fuel| Test flue gas temperature wood /smokeless
briquetted fuel| @ pascals of pressure
---|---|---|---
THE WOODLAND| 5.1/5.0 g/sec| 238/248 °C| 12 pa
A chimney height of not less than 4.5 metres measured vertically from the
outlet of the stove to the top of the chimney should be satisfactory.
Alternatively the calculation procedure given in BS5854:1980 may be used as
the basis for deciding whether a particular chimney design will provide
sufficient draught.
If it is found that there is excessive draught in the chimney then either an
adjustable flue damper or alternately a draught stabiliser should be fitted.
The adjustable flue damper should not close off the flue entirely but should
in its closed position leave a minimum continuous opening free area of at
least 20 % of the total cross sectional area of the flue or flue pipe.
Adequate provision e.g. easily accessible soot door or doors must be provided
for sweeping the chimney and connecting flue pipe.
Your appliance needs to be maintained routinely, the throat plate/baffle
should be cleaned regularly (monthly) . The flue pipe can be cleaned using a
flexible brush. Only Use a dry cloth on external surfaces. Over time the glass
may become dirty, clean with a damp cloth and polish off with dry cloth. If
the stove has not been used for some time the flue should be checked for
blockages before use. Do not modify the appliance; only use spares authorised
by the manufacturer.
STOVE PERFORMANCE & TESTING
Mendip Stoves, The Woodland models are tested in accordance with EN 13240.
| Output| Efficiency| CO (at 13% O2)| Particulates (at 13% O2 )
Nmg/m³| Nox (at 13% O2)
Nmg/m³| CnHm (at 13% O2) Nmg/m³
---|---|---|---|---|---|---
Wood| 5.0kW| 79.5%| 0.09%| 27| 103| 74
smokeless briquetted fuel| 4.9kW| 76.4%| 0.08%| 17| 135| 61
Weight & Nominal Heat Output for Wood and Smokeless Fuels
| Log Length| Wood Reload| Weight Wood Load| smokeless
briquetted fuel Reload| Weight smokeless briquetted fuel (anth)
---|---|---|---|---|---
Woodland| 35cm| 1hr| 1.2kg| 2hr| 1.5kg
THE MINIMUM DISTANCE TO COMBUSTIBLE MATERIALS
Combustible materials should not be located where the heat dissipating through
the walls of fireplaces or flues could ignite it. Therefore when installing
the stove in the presence of combustible materials due account must be taken
of the guidance on the separation of combustible material given in Building
Regulations Approved Document J and also in these stove instructions. The
minimum distances to flammable materials are specified on the EN 13240 plate
on the back of the stove.
When installing the stove 100mm from a combustible wall behind , use the
additional, rear convection panel supplied with the stove, this slots over the
rear convection panel providing additional radiant protection from the flue
collar. A twin wall insulated flue should be fitted flush to flue collar for
this type of installation.
| Minimum Distance to Combustible Materials| Suitable for 12mm non-
combustible floor plate
---|---|---
REAR| SIDES| FRONT
Woodland| 100mm| 250mm| 600mm| YES
Woodland Convection| 100mm| 100mm| 600mm| YES
PLEASE NOTE THAT A MINIMUM DISTANCE OF 1350mm STD WOODLAND FURNISHINGS SHOULD ALWAYS BE MAINTAINED
Woodland DC Convector Plus
Distance to combustibles rear and sides| Woodland DC
Distance to combustibles rear and sides
---|---
|
MINIMUM DISTANCE TO NON-COMBUSTIBLE MATERIALS
The stove can be recessed in a suitable sized non – combustible fireplace but
a permanent free air gap of at least 50mm must be left around the sides, the
top and the back of the stove; this is to facilitate a reasonable heat output
and allows access to the stove for removal and maintenance. A clearance of
100mm will give a better heat output.
All non – combustible walls closer than 100mm to the stove should be at least
75mm thick. For practical reasons the back wall of the fireplace recess and
the hearth should ideally be made of non -combustible material. When
installing your stove in a non combustible chamber, combustible materials
should not be located where the heat dissipating through the walls of
fireplaces or flues could ignite it. Therefore when installing the stove in
the presence of combustible materials due account must be taken of the
guidance on the separation of combustible material given in Building
Regulations Approved Document J and also in these stove instructions. The
minimum distances to flammable materials are specified on the EN 13240 plate
on the back of the stove.
To ensure that the stove has sufficient air flow available to it during
operation, please allow at least 40mm of clearance from the back of the air
intake to the rear wall. This means that if you are installing your stove
between 50mm and 100mm away from a non – combustible wall, it may be necessary
to remove the intake spigot.
HEARTH
The hearth should be able to accommodate the weight of the stove and its
chimney if the chimney is not independently supported. The Woodland stoves
have been tested and are suitable to be installed on a 12 mm non combustible
plate, such as 12mm glass plates. Installation of all hearths should comply in
size and construction so that it is in accordance with the provisions of the
current Building Regulations Approved Document J.
The clearance distances to combustible material beneath, surrounding or on the
hearth and walls adjacent to the hearth should comply with the guidance on the
separation of combustible material given in Building Regulations Approved
Document J and also in these stove instructions.
If the stove is to be installed on a combustible (wooden) floor, it must be
covered with a non-combustible material at least 12 mm thick, in accordance
with Building Regulations Approved Document J, to a distance of 30 cm in front
of the stove and 15 cm to each side measuring from the door of the combustion
chamber.
INSTALLING THE WOODLAND CONVECTION IN A CORNER POSITION
Woodland DC Distance to combustibles installation into a corner position
HOW TO FIT A LOGSTORE LEGS – Loxton – Churchill – Woodland
COMBUSTION AIR & PERMANENT AIR VENT
In order for the stove to perform efficiently and safely there should be an
adequate permanent air supply into the room in which the stove is installed to
provide combustion air. This is particularly necessary if the room is double-
glazed or a flue draught stabiliser is operating in the same room as the
appliance. The provision of air supply to the stove must be in accordance with
current Building Regulations Approved Document J. An opening window is not
appropriate for this purpose. Air inlets must be positioned in such a way that
they cannot be blocked. An air inlet may be a vent (the vent must be open and
the capacity for the vent sufficient when the stove is lit) .
Woodland models take all combustion air (primary, secondary & tertiary) from a
single 80mm port at the bottom rear of the stove, with the door closed the air
port supplies all combustion air for the appliance. This port can be connected
to the outside via a 80mm pipe so the appliance does not draw combustion air
from the room. However as this stove needs the door to be ajar when lighting
and combustion air is taken from the room when reloading. Mendip stoves
recommends the use of an additional air vent as laid out in document J .
The stove requires a permanent air vent to the room . This is to provide
adequate air supply in order for the stove to operate safely and efficiently.
in accordance with current Building Regulations the installer may have fitted
a permanent air supply vent into the room in which the stove is installed to
provide combustion air. This air vent should not under any circumstances be
shut off or sealed.
The direct air intake spigot (80mm diameter) to the rear of the stove is removable with a 2.5mm Allen key.
COMBUSTION CHAMBERS
Mendip Stoves are fitted internally with vermiculite heat deflection panels
and baffles, these panels are designed to ensure the maximum efficiency andare
an integral part of the clean burn process of the stove. These baffles should
not be removed other than for cleaning the stove. Any defective panels should
be replaced, (small hairline cracks do not need replacement) however can
develop during long term use to a larger crack, if this passes through the
vermiculite to the stove body then the panel must be replaced. When refuelling
your stove place the wood fuel into the chamber (wearing a glove), impact from
logs can cause the heat deflection panel to crack.
Connection to chimney
Mendip Stoves are built with a top flue outlet as standard, this can be
altered to a rear connection by removing the top collar, rear cover plate then
exchanging collar and plate. Care should be taken to ensure an airtight fit
when refitting collar and plate. When installing a rear flue exit model please
remove rear cleaning steel plate inside the flue collar box. A decorative
cover plate is included in each stove to cover the hole in the convection top
plate. This collar allows connection to either a masonry chimney or a
prefabricated factory made insulated metal chimney.
COMMISSIONING AND HANDOVER
Ensure all loose parts (bricks and grates) are fitted in accordance with the
instructions given in the instruction booklet. On completion of the
installation allow a suitable period of time for any fire cement/silicon and
mortar to cure, a small fire may be lit to check that smoke and fumes are
taken from the stove up the chimney and emitted safely into the atmosphere.
Do not run at full output for at least 24 hours after this appliance has been
installed.
On completion of the installation and commissioning ensure that the operating
instructions for the stove are left with the customer. Ensure to advise the
customer on the correct use of the appliance with the fuels likely to be used
in the stove and notify them to use only the recommended fuels for the stove.
Advise the user what to do should smoke orfumes be emitted from the stove.
The customer should be warned to use a fireguard to BS 8423:2002 in the
presence of children, aged and/or infirm persons.
Operating Guidance
OPERATING YOUR STOVE -WOODLAND DUAL CONTROL
THE WOODLAND STOVE HAS THREE AIR CONTROL LEVERS TO HELP REGULATE YOUR STOVE.
Air regulation, the three control levers perform differing tasks in regulating
the combustion air on your appliance:
Primary air: this is generally used when starting the fire or re igniting
the fire. If burning smokeless briquetted fuel then the primary will need to
be open. Primary air comes from below the grate.
Secondary air: this is commonly known as air wash, preheated air flows in
a continuous thin stream down the glass and into the very heart of the wood
fire, when burning wood this should always be open to enable cleaner
combustion.
Tertiary Air: this is injected into the rear of the fire chamber above
the logs, enabling re combustion of already burnt gases and improving the
quality of combustion.
If the stove is to be operated in a Smoke Control Area then this control MUST
remain pushed in at all times.
LIGHTING YOUR STOVE FOR THE FIRST TIME
Before lighting your stove for first time make sure you have read this manual
fully and acquainted yourself with the controls of this appliance.
Ensure that you have allowed sufficient time for the heat resistant sealant to
cure.
The heat-resistant paint on your stove will cure and harden the first time you
light your appliance. The curing process produces a good deal of smoke and
odour, it is therefore important that the first time you light your stove the
room should be well ventilated.
During the process it is important to open and close the stove door
periodically (every 30mins) during the first couple of firings therefore
preventing the door seal cord around the door from sticking and coming away
from the door. Once the heat-resistant paint has hardened the smell will
disappear.
Your stove is NOT designed to be used with the door open, the stove door must
be kept closed except when lighting the stove, adding firewood or removing ash
in order to prevent flue gases from escaping.
Use of Fire lighters
Quality Firelighters should be used when lighting your stove. (Neveruse
mentholated spirit, petrol or other flammable liquids). Lighting your stove
with firelighters will be more reliable and easier than using paper. Lighting
your fire with paper results in excess smoke, more ash and possible blackening
of glass.
HOW TO LIGHT YOUR WOODBURNING STOVE
Note: If the chimney is externally fitted or the stove has been installed
on a larger diameter clay chimney liner then on cold days it maybe necessary
to warm the flue using firelighters prior to lighting with wood.
-
Place two small dry split logs (% split) on the fire bed. Kindling stacked as in the picture which allows combustion air to flow freely and will aid ignition. On top of the kindling two or more non toxic firelighters.
-
Open fully Primary and Secondary air by pulling out the levers, this provides the stove with a mix of primary and secondary air to help establish the fire.
-
Light the firelighters and push door to closed position, latch in 1st position so the door is open 2 mm. (see picture) This provides additional combustion air for start up and reduces condensation on the door glass.
-
Once the flames from the logs are fully established, this can take up to 10 min’s. The door cannow be closed. Slide the Primary air inwards to the closed position.
If the stove flames begin to falter and generate smoke in chamber pull out primary lever again to re-establish the fire, it maybe necessary to unlatch the door again until the fire is fully established. -
Once the fire bed is established close primary air, slide the secondary in by 50%, forthe stove to burn cleanly plenty of secondary air is needed, do not be tempted to shut the fire down too early as this may cause smoke. At nominal heat output, expect to refuel your stove approximately once an hour. Check load weights for your model on the table on page 7. Use the glove when operating air controls and door.
The stove will get very hot during use, therefore due care must be exercised.
Please use the glove when operating air controls, door and ash pan.
WOOD FUEL
Good quality wood is the most important factor in your stove working
efficiently and cleanly. Always use dry split hardwood firewood (moisture
content of 20% or less). The dryness of the firewood plays an important role
because the use of wet wood results in poor fuel economy and may cause a tarry
sooty film on the internals of the stove.
Newly cut wood contains 60-70% water, making it totally unsuitable for use as
firewood; it should be stacked and air dried under cover for two years before
being used as firewood.
Do not burn liquid fuels, drift wood, finished, sawn wood, pallet wood,
chipboard/plywood, varnished wood or plastic coated wood, wood treated with
preservatives, or house hold waste.
WARNING NOTE
Properly installed, operated and maintained this stove will not emit fumes
into the dwelling. Occasional fumes from de-ashing and re-fuelling may occur.
However, persistent fume emission is potentially dangerous and must not be
tolerated. If fume emission does persist, then the following immediate action
should be taken:-
(a) Open doors and windows to ventilate the room and then leave the premises.
(b) Let the fire go out.
(c) Check for flue or chimney blockage and clean if required
(d) Do not attempt to relight the fire until the cause of the fume emission
has been identified and corrected. If necessary seek expert advice.
The most common cause of fume emission is flue way or chimney blockage. For
your own safety these must be kept clean at all times.
CO Alarm
Your installer should have fitted a CO alarm in the same room as the
appliance. If the alarm sounds unexpectedly, follow the instructions given
under “Warning Note” above.
Aerosols
Aerosols are flammable and therefore dangerous to use around alit stove. Do
not use aerosols sprays near your lit stove. The use of any aerosol is
dangerous and care must be take in handling aerosols.
OPERATING YOUR STOVE
Suitable fuels:- Your stove is tested to burn wood or registered smokeless
briquetted fuel . Wood briquettes can also be burnt but special account should
be taken of fuel weight. For a full list of suitable fuels, check with the
official solid fuels approvals body, HETAS or Solid Fuel Association. Do not
overload stove as this can cause excessive heat and damage the stove (see
table on page 7).
Wood and smokeless briquetted fuel should not be burned at the same time as
they require a different air supply for them to burn cleanly and efficiently.
Wood requires predominantly secondary air and smokeless fuel predominantly
primary air. If you want to change fuel type, wait until the stove requires
refuelling and then refuel with wood or smokeless briquetted fuel and adjust
the air controls accordingly.
ALWAYS KEEP FUEL LOAD BELOW TERTIARY PORTS AT REAR OF STOVE. Only use fuels
approved for use on heating stoves.
Do not burn liquid fuels, drift wood, finished wood, sawn wood, pallet wood,
chipboard/ plywood ,varnished wood or plastic coated wood, wood treated with
preservatives, or any house hold waste.
DO NOT EXCEED SPECIFIED FUEL WEIGHTS (SEE page.7).
DO NOT RUN AT FULL OUTPUT FOR EXTENDED PERIODS OF TIME.
DO NOT BURN HOUSE COAL. DO NOT BURN HOUSEHOLD WASTE.
THIS APPLIANCE IS NOT AN INCINERATOR.
MENDIP STOVES RECOMMEND THE USE OF A FLUE THERMOSTAT TO CHECK YOUR STOVE IS
NOT OVERHEATING. PLACE FLUE THERMOSTAT DIRECTLY ABOVE COLLAR OF STOVE AND
REFER TO TEMPERATURE GAUGE ON PAGE 6.
RE-FUELLING WHEN BURNING WOOD
Adding fuel to your stove when you only have glowing embers,and the flames
have died down, is the cleanest way to refuel your stove.
- Before refuelling, Pull open both the Primary and Secondary controls fully.
- Unlatch the door to equalise the pressure inside the stove with that of the room.
- Then, open the door gently.
- If it is necessary, use a poker to create a level bed before adding a piece of wood below the level of the tertiary air ports (please check weight table page 7).
- Now, close the door.
- Once the flames are fully established, close Primary air fully and close Secondary air to the nominal position halfway in (50% air supply). For optimum combustion efficiency the tertiary air control should be pushed in.
Please regard these instructions as guidelines because each installation will
be slightly different.
Experience will determine the settings that produce best results.
To prevent overheating your appliance we recommend that you use a flue
thermostat (placed on a non insulated section of pipe directly above the
collar of the stove).
The efficient operating temperature range is between 180°C and 250°C
These stoves are not designed to run overnight or for long periods unattended
(see page 15)
INCOMPLETE COMBUSTION
Incomplete combustion may lead to a build-up of hard, shiny soot on the inside
of your stove and glass. It is generally the results of an insufficient air
supply to the combustion chamber. If you find that this build-up is occurring
to your Mendip Stove, you should:
- Increase the amount of secondary air used when running the stove, ensure tertiary air control pushed in fully.
- Check that the fuel you use is suitable and dry (less than 20% moisture content).
- Check that your flue system (chimney) is producing sufficient draught.
It is important to check the draft conditions before lighting your stove. This
may be done, for instance, by crumpling a piece of newspaper, placing it in
the combustion cha mber a nd lighting it. The draft conditions are good if the
smoke is drawn away through the chimney.
TROUBLE SHOOTING
-
Fire Will Not Burn – check
a) the air inlet is not obstructed in any way,
b) that chimney and flue ways are clear,
c) that a suitable fuel is being used,
d) that there is an adequate air supply into the room,
e) that an extractor fan is not fitted in the same room as the fire. -
Fire Blazing Out Of Control – check
a) the doors are tightly closed,
b) the air controls are turned down to the minimum setting,
c) the flue damper is closed (if fitted),
d) a suitable fuel is being used,
e) the door seals are in good condition,
f) the chimney draft may be too strong
g) check ash pan seal and
h) check for ash below ash pan causing pan to seat incorrectly and clean out. -
Soot forms on the window
a) The firewood may be too wet
b) the intake of secondary air may be insufficient
c) fire not hot enough -
The stove fails to heat fully
a) The firewood may be too wet
b) the intake of secondary air may be insufficient -
Smoke or odour
a) weak chimney draft
b) check for blockages in the flue pipe/chimney
c) check the height of the chimney relative to the surroundings -
Soot in the chimney
a) The firewood may be too wet
b) intake of secondary air may be insufficient
LIGHTING THE STOVE – SOLID FUELS
SOLID SMOKELESS FUELS (Smokeless briquetted fuel)
The Woodland mode! is suitable for use with good quality smokeless fuels
(smokeless briquetted fuel) and has been fully tested to the relevant European
standard. Only use registered smokeless fuels on this stove. Take special note
of load quantities (page 7).
Note: on cold days it maybe necessary to warm the flue using two
firelighters.
-
Place Firelighters and afew smaller pieces of dry wood (kindling) among a small quantity of fuel in the combustion chamber.
-
Fully open (pull out) Primary and Secondary air, the stove now has total primary and secondary air for start up.
-
Using long match light the firelighters and securely close door.
-
Once the fire is established, open the door and add a full load of fuel (see weight table on page7)
Do Not Overload. Do not cover the tertiary air ports. -
Close fire door and adjust Primary air to about 80% open and the Secondary air 10% open.
-
Once the additional fuel is burning, adjust the amount of primary air entering the combustion chamber to your personal preference.
Please regard these instructions as guidelines because each installation will
be slightly different. Experience will determine the settings that produce
best results.
To prevent overheating your appliance we recommend that you use a flue
thermostat (placed on a non insulated section of pipe directly above the
collar of the stove).
The efficient operating temperature range is between 180°C and 250°C
These stoves are not designed to run overnight or for long periods unattended
(see “Overnight Burning”)
To Re-fuel Your Stove Using Solid Fuel:
- Your stove will need to be refueled approximately every 2 hours (see page 7.)
- Before refueling, open the control to full primary air.
- Then slowly open door to allow the pressure to equalize between the inside of the stove and the room.
- Once the door has been opened, de -ash your stove with use of poker (not provided).
- Add fuel (see weight table on page 7), ensuring the fuel is placed below the level of the tertiary air ports.
- Finally, close the door and when then fire has re-established reduce the primary air supply to your preferred settings.
PLEASE USE A HEAT RESISTANT GLOVE WHEN OPERATING THE AIR CONTROLS, DOOR AND
ASH PAN, AS THE APPLIANCE WILL BECOME VERY HOT.
HOUSE COAL AND PETROLEUM COKE ARE NOT SUITABLE FOR USE ON THIS STOVE; ITS
USE WILL INVALIDATE THE GUARANTEE.
OVERNIGHT BURNING
Mendip Stoves do not recommend burning registered smokeless briquetted fuel in
a slumbering position, Mendip stoves are designed to burn wood or quality
registered smokeless fuels. Wood burns more efficiently and cleanly if it is
burnt hotter.
Mendip stoves do not recommend that their stoves are burnt overnight for this
reason.
As a night time regime we recommend that the fire is loaded when hot and burnt
for five minutes with the secondary air control fully open, until the new wood
has taken and is burning, Then place the Secondary Air to 50%. On returning to
the stove in the morning the fire will have burn out, reload with some paper
(or a firelighter) and some kindling, Fully open the Primary and Secondary air
controls and the fire should relight quickly. Beware as the ash bed will have
hot embers.
MAINTENANCE
Mendip stoves recommends that your model needs to have the ash removed from
the stove at regular intervals (weekly if used daily). Allowing the ash pan to
over flow can impede the function of the stove and can cause possible damage
to the stove grate and ash pan. To remove ash pan, use heat protecting glove
provided. Lift and pull out of firebox chamber. Take care to support ash pan
during movement. Make sure the stove is completely cold before cleaning out
ash (embers can remain hot for over 24 hours). Ash must be stored in a non-
combustible container and must not be mixed with other combustible waste.
Annual service
The stove should be serviced by a registered dealer once a year. The stove,
the flue pipe connection and the chimney should be checked regularly by a
qualified engineer. The chimney should also be checked for blockages before
relighting the stove if it has not been used for an extended period of time.
Insulating fire bricks checked for wear andreplacedif necessary door and ash
pan rope seals should be changed annually, glass clamps & glass should checked
making sure glass is correctly positioned.
To clean the inside of the stove, remove all ash, soot and tar residue from
the combustion chamber. Remove insulated chamber panels and baffle, dirt and
soot will collect behind it and this must be cleaned out. The paint can wear
thin in exposed places due to overheating. This, and other lacquer damage, may
be repaired using Mendip paint spray available from your Mendip dealer. To
clean the outside of the stove use a dry cloth.
Your stove should be serviced annually by a registered dealer as a condition
of the extended warranty of the stove, failure to maintain a service record
will invalidate the extended warranty on your stove.
Prolonged non use (summer)
If the stove is to be left unused for a prolonged period of time (e.g. over
the summer) then it should be given a thorough clean to remove ash and un-
burnt fuel residues. To enable a good flow of air through the appliance to
reduce condensation and subsequent damage, leave the air controls fully open.
It is important that the flue connection, any appliance baffles or throat
plates and the chimney are swept prior to lighting up after a prolonged
shutdown period.
Spare parts & unauthorised alterations
Only the manufacturer’s own components, or replacement parts recommended and
approved by Mendip stoves, shall be used for appliance servicing and repair.
Any unauthorised alterations will invalidate the stove warranty and compliance
with EN13240.
SWEEPING YOUR CHIMNEY & CHIMNEY FIRES
Ensure that your appliance, flue ways and chimney are swept regularly. This
can be incorporated in the service regime of your appliance. Regular sweeping
is essential and means at least once a year for smokeless fuels anda minimum
of twice a year for wood . If a throat plate is incorporated, it is essential
that the throat plate is removed and cleaned above, all ash and debris should
be removed. Ensure adequate access to cleaning doors where it is not possible
to sweep the chimney through the appliance.
Where a chimney has served an open fire installation previously it is possible
that the higher flue gas temperature from a closed appliance may loosen
deposits that were previously firmly adhered, with the consequent risk of flue
blockage.
It is therefore recommended that the chimney be swept a second time within a
month of regular use after installation of the stove.
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney fires should not
occur. However, if a chimney fire does occur turn the air control setting to
the minimum, and tightly close the doors of the stove. This should cause the
chimney fire to go out in which case the control should be kept at the minimum
setting until the fire in the stove has gone out. The chimney and flue ways
should then be cleaned. If the chimney fire does not go out when the above
action is taken then the fire brigade should be called immediately.
After a chimney fire the chimney should be carefully examined for any damage.
Expert advice should be sought if necessary.
BURNING WOOD IN A SMOKE CONTROL AREA
You must purchase a smoke exempt version of a Mendip Stove; the tertiary air
control should be pushed in fully at all times to comply with regulations. Any
alteration to this setting will invalidate the stoves compliance for smoke
control areas.
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the
district of the authority to be a smoke control area. It is an offence to emit
smoke from a chimney of a building, from a furnace or from any fixed boiler if
located in a designated smoke control area. It is also an offence to acquire
an “unauthorised fuel” for use within a smoke control area unless it is used
in an “exempt” appliance (“exempted” from the controls which generally apply
in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary
of State in accordance with changes made to sections 20 and 21 of the Clean
Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland
appliances are exempted by publication on a list by Scottish Ministers under
section 50 of the Regulatory Reform (Scotland) Act 2014. In Wales and Northern
Ireland these are authorised by regulations made by Welsh Ministers and by the
Department of the Environment respectively.
Further information on the requirements of the Clean Air Act can be found
here: https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993
including designation and supervision of smoke control areas and you can
contact them for details of Clean Air Act requirements.
The Woodland Mk.4 SE and Woodland Large stoves have been recommended as
suitable for use in smoke control areas when burning wood logs. The appliances
can also burn authorised fuels in smoke control areas. More information
regarding authorised fuels can be found at_
https://smokecontrol.defra.gov.uk/fuels.php .
The SE appliances include a modified air control to prevent closure of the
secondary air control beyond 25% open(11mm) alterations should not be
attempted. Mendip Stoves smoke control stoves should not be burnt with the
door left open.
The refuelling procedure :
Allow the newly charged fuel to burn with the secondary air control set at
maximum for up 3 to 4 minutes. After this period, with flames from the logs
fully established, close the secondary air supply to the low output setting.
When operating at high output (secondary air set fully open) the new refuel
charge does not require any boost air to establish combustion.
Refuelling on to a low fire bed
If there is insufficient burning material in the fire bed to light a new fuel
charge, excessive smoke emission can occur.
Refuelling must be carried out onto a sufficient quantity of glowing embers
and ash that the new fuel charge will ignite in a reasonable period. If there
are too few embers in the fire bed, add suitable kindling to prevent excessive
smoke.
Fuel Overloading
The maximum amount of fuel specified in this manual should not be exceeded,
overloading can cause excess smoke.
Air controls & doors left open
Operation with the air controls fully open can cause excess smoke. The
appliance must not be operated with air controls, appliance dampeners or the
door left open except as direct in the instructions.
STOVE PARTS, COMBUSTION CHAMBER, ASSEMBLY
This section shows the parts contained in your stove, each stove has over 80
spare-parts and, each part is detailed. When new parts are required the
section will allow spares to be recognised and ordered. As a further source of
reference please visit www.eurostove.co.uk
for latest spare-part information.
LOOSE PARTS
Always use the operating tools provided when handling parts likely to be hot
when the stove is in use. Your stove has the following parts in the stove.
- Cast Iron grate & log retainer.
- Ashpan & Ashpan tool
- Stove Glove
- Top plate decorative cover plate.
- Instruction manual & warranty card
- Vermiculite brick linings ( these are integral to the stoves performance-Do not throw away)
- Moisture absorbency bag
- Flue heat deflection panel
COMBUSTION CHAMBER
HOW TO REMOVE THE INTERNAL BRICK PARTS
| To remove the vermiculite brick set take the following steps:
Lift out the 2 base bricks next to the grate.
Remove the left hand vermiculite side brick by lifting the top baffle brick
and pulling the side brick down from the top.|
---|---|---
| It is now possible to remove the top baffle brick by lifting up the left
side and sliding it to the left then dropping it down.
The right hand side brick can be removed by gently pulling it down from the
top.
You may find it easier to remove the cast iron grate Before finally removing
the rear brick.|
| To remove upper steel baffles/ turbulence plates
Firstly lift the upper, ribbed, turbulence plate, slide forwards towards the
front of the stove.
This will create enough space to allow the plate drop down so that the baffle
can be removed.|
| To remove rear steel baffle is Simply push this away from The holding frame,
which it rests on, and twist it to fit through the opening.
You now have access to the flue system, whether the collar is situated on the
top or to the rear of your stove.|
Exploded parts diagrams
VERMICULITE BRICK SET PART NUMBERS
VERMICULITE BRICKS REFERENCE TABLE
Diagram No. | Part No. | Description | No. Of Parts |
---|---|---|---|
ES-500-400-1 | Full Brick Set – Loxton 5 | 8 | |
1 | ES-500-412-1 | Rear Brick | 1 |
2 | ES-500-413-1 | Baffle Brick | 1 |
3 | ES-500-414-1 | Right Side Brick | 1 |
4 | ES-500-415-1 | Left Side Brick | 1 |
5 | ES-500-417-1 | Base Brick Side | 2 |
6 | ES-500-417-2 | Base Brick Rear | 2 |
7 | ES-500-420-0 | RH Spacer | 1 |
8 | ES-500-421-0 | LH Spacer | 1 |
WOODLAND DOOR ASSEMBLY – ( complete door assembly M??????-0?-00-00-??)
Diagram No. | Part No. | Description |
---|---|---|
1 | ES-500-209-0 | Door Handle |
2 | CH-500-120-0 | Glass Clamp |
3 | ES-500-220-0 | Cast ODoor Frame (only) |
4 | ES-500-501-0 | Glass |
5 | M90520-06-02-01-05 | Door Rope Seal Kit |
6 | M90520-06-13-99-02 | Handle Fixing Kit (complete) |
7 | M90026-01-02-01-04 | Glass Seal Kit (incl. 6 Clamp Pads) |
8 | U91000-98-12-99-00 | M5 X 8mm screw ( 6) |
9 | Handle Latch Assembly |
STOVE PART NUMBERS
STOVE PART NUMBERS
Diagram No. | Part No. | Description |
---|---|---|
1 | ES-500-187-0 | Top Flue Rear Convection Panel |
2 | EST 2051 000 11 3 | Flue Collar |
3 | M90500-07-03-00-04 | Flue Cover Plate |
4 | M90500-07-10-01-01 | Collar/Blanking Plate Seal |
5 | ES-500-142-0 | Flue Blanking Plate |
6 | CH-500-180-0 | Secondary Air Smoke Deflector |
7 | ES-S00-117-0 | Turbulence Plate |
8 | B90300-05-01-00-00 | Grate |
9 | ES-500-147-0 | Grate Support |
10 | ES-500-140-1 | Log Retainer |
11 | ES-500-703-0 | Ash Pan |
12 | ES-500-612-0 (R)/ ES-500-611-0 (L) | Convector Side Panel Right/ Left |
13 | ES-500-614-0 | Rear Inner Heat Shield |
14 | ES-500-613-0 | Rear Outer Heat Shield |
15 | ES-500-703-0 | Tool |
16 | ES-500-194-0 | Top Plate |
17 | ES-500-109-0 | Cleaning Access Plate |
18 | CH-500-164-0 | Logstore Base |
19 | ES-500-152-1 | Air control wheel ( primary /secondary) |
20 | ES-500-154-1 | Guide Bracket |
21 | CH-500-125-0 | Secondary Slider Bar |
22 | CH-500-123-0 | Primary Slider Bar |
23 | ES-500-133-0 | Tertiary air adjustment shaft |
24 | ES-400-172-0 | Tertiary Knob |
25 | ES-300-711-3 | Primary /Secondary knob |
26 | CH-500-119-0 | Lever cover shield |
27 | ES-500-122-0 | Tertiary air slider |
28 | ES-500-154-1 | Air adjustment block |
29 | Tension spring | |
30 | M5 lager washer / m5 nut | |
31 | ES-500-130-0 | Air inlet assembly |
32 | ES-500-128-0 | External air box assembly |
33 | ES-500-600-0 | Internal convector panels |
Declaration of Performance DOP
NO: | DOP 7 |
---|---|
Product type: | Freestanding stove |
Type, batch or serial number: | Woodland DC |
Intended use of the product: | Heat distribution/room heating. |
Without hot water supply.
Name and Address of the manufacturer:| Mendip Stoves Eurostove Ltd
Unit H1, Mendip Industrial Estate, Rooksbridge, Somerset TA9 4NG
AVCP:
System(s) of assessment and verification of constancy op performance (AVCP)
of the construction product as set out in CPR, Annex V| System 3
ISO 9001 CA15256
Notified body: Kiwa Gastec, Kiwa House, Bishops Cleeve, Cheltenham,
GL52 7DQ, UK Test report no: 61511-1| NB 0558 KIWA UK No 61511-1 (wood)
NB 0558 KIWA UK No 61511-1 (maxibrite)
Declared performance:|
Harmonized technical specification| EN13240:2001/A2:2004/AC2007
Essential characteristics| Performance
Fire safety|
Reaction to fire| Al
Distance to combustible materials| Minimum distances, in mm
Rear – 100mm
Side = 250mm std ,
Side with flat convector panel = 100mm,
Risk of burning fuel falling out| NPD
Emission of combustion products| CO 0,09% [0,08%] (maxibrite)
NOx [ 103 mg/Nm3] (w) [135 mg/Nm3] (maxibrite) OGC 74 mgC/Nm3 [61
mgC/Nm3] (maxibrite) Dust [27 mg/Nm3 ] (w) [17 mg/Nm3 ] (maxibrite)
Surface temperature| Pass
Electrical safety| –
Clean ability| Pass
Maximum water operating pressure| –
Flue gas temperature at nominal heat output| T [ 238°] (w) T [ 248°]
(maxibrite)
Mechanical resistance (to carry a chimney/flue)| NPD
Thermal output|
Normal heat output| 5.0 kW (w) 4.9 kW (maxibrite)
Room heating output| 5.0 kW (w) 4.9 kW (maxibrite)
Water heating output| N/A -*kW
Energy efficiency| r| [79.5%] (W) [76.4%] (maxibrite)
Rooksbridge
March 2022
(Date and place of Issue)
Signature
DECLARATION: The performance of the product identified in points 1 and 2
in conformity with the declared performance in point 8. This declaration of
performance is issued under the sole responsibility of the manufacturer
identified in point 4.
Signed on behalf of the manufacturer
Chris Baines
Director
Eurostove Ltd, Unit H1, Mendip Industrial Estate, Rooksbridge. Somerset. TA9
4NG
Tel: 01934 750500
E-mail: info@eurostove.co.uk
Mendip Stoves
Unit H1
Mendip Industrial Estate
Mendip Road
Rooksbridge, Somerset
BS26 2UG
Website:www.mendipstoves.co.uk
Email:info@eurostove.co.uk
Telephone: 01934 750 500 CODE:
M10530-49-00-99-01″
Woodland DC std – Version 2.1 – May 2022
Documents / Resources
|
Mendip M00530-00-00-00-02 Woodland DC SE Multi Fuel Wood Burning
Stove
[pdf] Instruction Manual
M00530-00-00-00-02 Woodland DC SE Multi Fuel Wood Burning Stove,
M00530-00-00-00-02, Woodland DC SE Multi Fuel Wood Burning Stove, Fuel Wood
Burning Stove, Burning Stove
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>