velleman DVM841 Digital Handheld Multimeter
Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device
after its lifecycle could harm the environment. Do not dispose of the unit (or
batteries) as unsorted municipal waste; it should be taken to a specialized
company for recycling. This device should be returned to your distributor or
to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before
bringing this device into service. If the device was damaged in transit, do
not install or use it and contact your dealer.
U sed Symbols
**** | AC (Alternating Current) |
---|---|
**** | DC (Direct Current) |
**** | Both AC and DC |
**** | Risk of Electric shock. A potentially hazardous voltage is |
possible.
**| Caution: risk of danger, refer to the user manual for safety
information.
Warning : a hazardous condition or action that may result in injury or
death
Caution : condition or action that may result in damage to the meter or
equipment under test
**| Double insulation (class 2-protection)
| Earth
| Fuse
| Capacitor
| Diode
****| Continuity
General Guidelines
Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.
| This symbol indicates: Read instructions
Not reading the instructions and manual can lead to damage, injury or
death.
---|---
| This symbol indicates: Danger
A hazardous condition or action that may result in injury or death
| This symbol indicates: Risk of danger/damage
Risk of a hazardous condition or action that may result in damage, injury
or death
| This symbol indicates: Attention; important information
Ignoring this information can lead to hazardous situations.
| WARNING: To avoid electrical shock always disconnect the test leads
prior to opening the housing. To prevent fire hazards, only use fuses with the
same ratings as specified in this manual. Remark: refer to the warning on
the battery compartment
| Avoid cold, heat and large temperature fluctuations. When the unit is moved
from a cold to a warm location, leave it switched off until it has reached
room temperature. This to avoid condensation and measuring errors.
| Protect this device from shocks and abuse. Avoid brute force when operating.
| Pollution degree 2-device. For indoor use only. Keep this device away from
rain, moisture, splashing and dripping liquids. Not for industrial use.
Refer to §8 Pollution degree.
| Keep the device away from children and unauthorised users.
| Risk of electric shock during operation. Be very careful when measuring
live circuits.
| There are no user-serviceable parts inside the device.
Refer to an authorized dealer for service and/or spare parts.
| This is an installation category CAT III measuring instrument. Refer to
§7 Overvoltage/installation category.
| Read this addendum and the manual thoroughly. Familiarise yourself with the
functions of the device before actually using it.
| All modifications of the device are forbidden for safety reasons. Damage
caused by user modifications to the device is not covered by the warranty.
| Only use the device for its intended purpose. Using the device in an
unauthorized way will void the warranty. Damage caused by disregard of certain
guidelines in this manual is not covered by the warranty and the dealer will
not accept responsibility for any ensuing defects or problems.
Maintenance
| There are no user-serviceable parts inside the device.
Refer to an authorized dealer for service and/or spare parts.
---|---
Before performing any maintenance activities, disconnect the test leads from
the jacks. For instructions on replacing battery or fuse, refer to §11
Battery and fuse replacement.
Do not apply abrasives or solvents to the meter. Use a damp cloth and mild
detergent for cleaning purposes.
During Use
| Risk of electric shock during operation. Be very careful when
measuring live circuits.
---|---
- Never exceed the limit value for protection. This limit value is listed separately in the specifications for each range of measurement.
- Do not touch unused terminals when the meter is linked to a circuit which is being tested.
- Never use the meter with CAT II installations when measuring voltages that might exceed the safety margin of 500 V above earth ground. Never use the meter with CAT III installations when measuring voltages that might exceed the safety margin of 300 V above earth ground.
- Set the range selector at its highest position if the intensity of the charge to be measured is unknown beforehand.
- Disconnect the test leads from the tested circuit before rotating the range selector in order to change functions.
- When carrying out measurements on a TV set or switching power circuits, always remember that the meter may be damaged by any high amplitude voltage pulses at test points.
- Always be careful when working with voltages above 60 VDC or 30 VAC rms. Keep your fingers behind the probe barriers at all times during measurement.
- Never perform resistance, diode or continuity measurements on live circuits. Make sure all capacitors in the circuit are depleted.
General Description
This device is a battery-operated, hand-held 3 ½ digital multi-meter for measuring DC and AC voltages, DC current and resistance. It also offers the possibility of executing continuity tests and of testing diodes and transistors. The back light is optional.
Refer to the illustration on page 2 of this manual:
-
Display
3 ½ digits, 7 segments, LCD: 47 x 15 mm 2 -
Back light
In any range, press this button to activate the backlight. Press again to deactivate. -
Rotary switch
This switch is used to select functions and desired ranges as well as to turn the meter on/off. -
Hold button
In any range, press this button to freeze the last reading. Press again to unfreeze. -
“VmA” jack
Insert the red (positive) test lead in this connector to measure voltage, resistance and current (except 10 A). -
“COM” jack
Insert the black (negative) test lead. -
“10A” jack
Insert the red test lead in this connector in order to measure a max. current of 10 A.
Overvoltage/Installation Category
DMMs are categorized depending on the risk and severity of transient
overvoltage that might occur at the point of test. Transients are short-lived
bursts of energy induced in a system, e.g. caused by lightning strike on a
power line.
The existing categories according EN 61010-1 are:
CAT I| A CAT I-rated meter is suitable for measurements on protected
electronic circuits that are not directly connected to mains power, e.g.
electronics circuits, control signals…
---|---
CAT II| A CAT II-rated meter is suitable for measurements in CAT I-
environments and mono-phase appliances that are connected to the mains by
means of a plug and circuits in a normal domestic environment, provided that
the circuit is at least 10 m apart from a CAT III- or 20 m apart from a CAT
IV-environment. E.g. household appliances, portable tools…
CAT III| A CAT III-rated meter is suitable for measurements in CAT I- and CAT
II-environments, as well as for measurements on (fixed) mono- or poly-phased
appliances which are at least 10 m apart from of a CAT IV-environment, and for
measurements in or on distribution level equipment (fuse boxes, lighting
circuits, electric ovens).
CAT IV| A CAT IV-rated meter is suitable for measuring in CAT I-, CAT II- and
CAT III-environments as well as on the primary supply level. Note that for all
measurements on equipment for which the supply cables run outdoors (either
overhead or underground) a CAT IV meter must be used.
Warning:
This device was designed in accordance with EN 61010-1 installation category
CAT II 500 V and CAT III 300 V. This implies that certain restrictions in use
apply that are related to voltages and voltage peaks which can occur within
the environment of use. Refer to the table above
| This device is only suitable for measurements up to 500 V in CAT II
and up to 300 V in CAT III
---|---
Pollution Degree
IEC 61010-1 specifies different types of pollution environments, for which different protective measures are necessary to ensure safety. Harsher environments require more protection, and the protection against the pollution which is to be found in a certain environment depends mainly on the insulation and the enclosure properties. The pollution degree rating of the DVM indicates in which environment the device may be used.
Pollution degree 1| No pollution or only dry, nonconductive pollution occurs.
The pollution has no influence. (only to be found in hermetically sealed
enclosures)
---|---
Pollution degree 2| Only nonconductive pollution occurs. Occasionally,
temporary conductivity caused by condensation is to be expected.(home and
office environments fall under this category)
Pollution degree 3| Conductive pollution occurs, or dry nonconductive
pollution occurs that becomes conductive due to condensation that is to be
expected.
(industrial environments and environments exposed to outside air – but not in contact with precipitation)
Pollution degree 4| The pollution generates persistent conductivity caused by conductive dust or by rain or snow. (exposed outdoor environments and environments where high humidity levels or high concentrations of fine particles occur)
Warning: This device was designed in accordance with EN 61010-1
pollution degree 2. This implies that certain restrictions in use apply
that
are related to pollution which can occur within the environment of use. Refer
to the table above.
| This device is only suitable for measurements in Pollution degree class 2
environments.
---|---
Specifications
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CAT I, CAT II and CAT III environments
(see §7)
Use this meter only in a pollution degree 2 environment (see §8)
Ideal working conditions include:
temperature: 0 °C to 40 °C (32 °F to 104 °F) relative humidity: max. 80 %
altitude: max. 2000 m (6560 ft)
voltage ………………………………………………………………… 500 V fuse protection
F500 mA/500 V, 5 x 20 mm
F10 A/500 V, 5 x 20 mm
power supply ………………………………… 2 x 1.5 V AAA/R03P (incl.)
display …………………………………………………… LCD, 1999 counts
display dimensions ……………………………………………47 x 15 mm
over-range ……………………………………………………………….. yes
continuity buzzer ………………………………………………………… yes
diode test …………………………………………………………………. yes
low-battery indication ………………………………………………….. yes
ranging mode ………………………………………………………. manual
ranges ………………………………………………………………………19
data hold …………………………………………………………………. yes
backlight ………………………………………………………………….. yes
auto power-off ……………………………………………………………. no
dimensions …………………………………………….. 74 x 125 x 30 mm
weight (with battery) …………………………………………….. ± 100 g
storage environment
temperature …………………………………………. -20 °C to 60 °C
humidity …………………………………………………… < 90 % RH test lead probe (incl.) . CAT II 1000
V/CAT III 600 V, 10 A, L = 75 cm
DC VOLTAGE
| Do not measure circuits that may contain voltages > 500 V
---|---
range| resolution| accuracy
200 mV| 0.1 mV| ± (1.0 % rdg + 2 digits)
2000 mV| 1 mV
20 V| 10 mV
200 V| 100 mV
500 V| 1 V| ± (1.2 % rdg + 2 digits)
Overload protection: 500 V DC or AC rms
Impedance: 1 MΩ
AC VOLTAGE
| Do not measure circuits that may contain voltages > 500 V
---|---
range| resolution| accuracy
200 V| 100 mV| ± (1.5 % rdg + 3 digits)
500 V| 1 V
Average sensing, calibrated to rms of sine wave
Frequency range: 40-500 Hz
Overload protection: 500 V DC or AC rms
Impedance: 450 kΩ
DC CURRENT
**** | Do not measure circuits that may contain voltages > 500 V |
---|---|
range | resolution |
200 µA | 0.1 µA |
2 mA | 1 µA |
20 mA | 10 µA |
200 mA | 100 µA |
10 A | 10 mA |
Overload protection: F500 mA/500 V, F10 A/500 V fuse
Note: 10 A up to 10 seconds
RESISTANCE
**** | Do not conduct resistance measurements on live circuits |
---|---|
range | resolution |
200 Ω | 0.1 Ω |
2k Ω | 1 Ω |
20 kΩ | 10 Ω |
200 kΩ | 100 Ω |
2 MΩ | 1 kΩ |
Overload protection: F500 mA/500 V fuse
DIODE AND CONTINUITY
**** | Do not conduct diode or continuity measurements on live circuits |
---|---|
range | description |
**** | display reads the approximate forward voltage of the diode |
forward DC current ± 10 µA reversed DC voltage ± 1.8 V
****| built-in buzzer sounds if resistance < 50 Ω| open-circuit voltage ± 1.8 V
Overload protection: F500 mA/500 V fuse
Voltage Measurement
**** | Do not measure circuits that may contain voltages > 500 V |
---|---|
**** | Use extreme caution when measuring voltages higher than 60 VDC or 30 |
VAC rms.
Always place your fingers behind the protective edges of the test probes while
measuring!
DC VOLTAGE MEASUREMENT
- Connect the red test lead to the “VΩmA” jack and the black lead to the “COM” jack.
- Set the rotary switch in the desired V position. If the voltage to be measured is unknown beforehand, you should set the range switch in the highest range position and then reduce gradually until the ideal resolution is obtained.
- Connect the test leads to the source being measured.
- Read the voltage value on the LCD display along with the polarity of
the red lead connection.
AC VOLTAGE MEASUREMENT
- Connect the red test lead to the “VΩmA” jack and the black test lead to the “COM” jack.
- Set the rotary switch in the appropriate V~ position.
- Connect the test leads to the source to be measured.
- Read the voltage value on the LCD display.
Current Measurement
**** | Do not measure circuits that may contain voltages > 500 V |
---|---|
**** | Use extreme caution when measuring voltages higher than 60 VDC or 30 |
VAC rms.
Always place your fingers behind the protective edges of the test probes while
measuring!
- Connect the red test lead to the “VΩ mA” jack and the black test lead to the “COM” jack (switch the red lead to the “10A” jack for measurements between 200 mA and 10 A).
- Set the rotary switch (DCA) in the desired position.
- Open the circuit in which the current is to be measured and connect the test leads to the circuit IN SERIES.
- Read the current value and the polarity of the red lead connection on the LCD display
Resistance Measurement
****| Do not conduct resistance measurements on live circuits. Make sure all
capacitors in the circuit are depleted.
---|---
-
Connect the red test lead to the “VΩmA” jack and the black test lead to
the “COM” jack (the red lead has a positive polarity “+”). -
Set the rotary switch in the appropriate “Ω” range position.
-
Connect the test leads to the resistor to be measured and read the LCD display.
-
If the resistance being measured is connected to a circuit, turn off the power and discharge all capacitors before applying the test probes.
Diode Testing
****| Do not conduct diode or continuity measurements on live circuits.
Make sure all capacitors in the circuit are depleted.
---|---
- Connect the red test lead to “VΩmA” jack and the black one to the “COM” jack (the red lead has a positive polarity “+”.).
- Set the rotary switch in the “ ” position.
- Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode. The approx. forward voltage drop of the diode will be displayed. If the connection is reversed, the display will merely show a “1”.
Continuity Testing
****| Do not conduct diode or continuity measurements on live circuits.
Make sure all capacitors in the circuit are depleted.
---|---
- Connect the red test lead to “VΩmA” and the black one to “COM”.
- Set the range switch in the “ ” position.
- Connect the test leads to two points of the circuit to be tested. If continuity exists, the built-in buzzer will sound.
Battery and Fuse Replacement
**| WARNING: To avoid electrical shock always disconnect the test
leads prior to opening the housing. To prevent fire hazards, only use fuses
with the same ratings as specified in this manual.
Remark:** refer to the warning on the battery compartment
---|---
- When “ ” is displayed, the battery should be replaced.
- Fuses rarely need replacement and blown fuses almost always result from human error
To replace the battery or fuse:
- Switch of the meter.
- Remove the two screws on the bottom of the case and gently open the housing.
- Remove the old battery and insert a new one.
- Close the housing and fasten the screws.
Battery: 2 x 1.5 V AAA/R03P, make sure to respect the polarity
Fuses: F500 mA/500 V and F10 A/500 V, 5 x 20 mm
Make sure the meter is closed tight and put the protective edge back in place
before using the meter.
Troubleshooting
If the device beeps continuously while measuring continuity, this means that
the F500 mA/500 V internal fuse is defective. Replace this fuse.
Keep in mind that a low battery level could lead to incorrect measurements.
Replace the battery on a regular basis.
(tip: the reduced luminosity of the backlight/LCD display indicates a low
battery level)
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our websitewww.velleman.eu. The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights
reserved. No part of this manual may be copied, reproduced, translated or
reduced to any electronic medium or otherwise without the prior written
consent of the copyright holder.
Velleman® Service and Quality Warranty
Since its foundation in 1972, Velleman® acquired extensive experience in the
electronics world and currently distributes its products in over 85 countries.
All our products fulfil strict quality requirements and legal stipulations in
the EU. In order to ensure the quality, our products regularly go through an
extra quality check, both by an internal quality department and by specialized
external organisations. If, all precautionary measures notwithstanding,
problems should occur, please make appeal to our warranty(see guarantee
conditions).
General Warranty Conditions Concerning Consumer **Products (for
EU):**
- All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase.
- Velleman® can decide to replace an article with an equivalent article, or to refund the retail value totally or partially when thecomplaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion.
You will be delivered a replacing article or a refund at the value of 100% of the purchase price in case of a flaw occurred in the first year after the date of purchase and delivery, or a replacing article at 50% of the purchase price or a refund at the value of 50% of the retail value in case of a flaw occurred in the secondyear after the date of purchase and delivery.
Not covered by warranty:
– all direct or indirect damage caused after delivery to the article
(e.g. by oxidation, shocks, falls, dust, dirt, humidity…), and by the article,
as well as its contents (e.g. data loss), compensation for loss of profits;
– consumable goods, parts or accessories that are subject to an aging process
during normal use, such as batteries (rechargeable, non-rechargeable, built-in
or replaceable), lamps, rubber parts, drive belts… (unlimited list);
– flaws resulting from fire, water damage, lightning, accident, natural
disaster, etc.…;
– flaws caused deliberately, negligently or resulting from improper handling,
negligent maintenance, abusive use or use contrary to the manufacturer’s
instructions;
– damage caused by a commercial, professional or collective
use of the article (the warranty validity will be reduced to six (6) months
when the article is used professionally);
– damage resulting from an inappropriate packing and shipping of the article;
– all damage caused by modification, repair or alteration performed by a third
party without written permission by Velleman®.
- Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description.
- Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a nondefective article can also involve handling costs.
- Repairs occurring after warranty expiration are subject to shipping costs.
- The above conditions are without prejudice to all commercial warranties.
The above enumeration is subject to modification according to the article (see article’s manual).
Made in PRC
Imported by Velleman nv
Legen Heirweg 33, 9890 Gavere, Belgium
www.velleman.eu
Documents / Resources
|
velleman DVM841 Digital Handheld
Multimeter
[pdf] User Manual
DVM841, Digital Handheld Multimeter, Handheld Multimeter, DVM841, Multimeter
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>