Product Specifications
Model No. | HV1843T | HV1843RGBW |
---|---|---|
Name | Split | |
Material | 316 Stainless Steel | |
Colour | Stainless Steel | |
IP Rating | IP67 | |
Input Voltage | 12v DC | |
Protection Class | (Low Voltage) | |
Lamp Base | Built-In LED | |
Lamp Wattage | 1 x 12w | |
Colour Temp | TRI Colour – 3000k, 4000k, 5500k | RGBW (RGB + 3000K) |
Lumens | 9001m, 10301m, 12001m | 4151m (3000k) |
CRI | > 80 | |
Wiring | Parallel | |
Dimmable | No | Yes with RGBW Controller |
Warranty | 3 Years Replacement* |
Important Safety Issues:
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- Ensure all electrical mains are disconnected before any installation.
- Modification of this product will void any warranty.
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
- When installing low voltage fittings, the Voltage to fitting must be within +or- 5% of the voltage required, if not within this allowance warranty will be voided.
- Aluminum and 304SS fittings must not be installed within 5km of any saltwater environments.
- All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on the fitting. (Warranty does not cover Tea Staining)
- All o-rings and seals must be in place correctly to maintain the warranty
- When installing inground light fittings, Adequate drainage must be allowed to prevent fittings from sitting in water for a long period of time, if no drainage is allowed, the Warranty will be voided, See sample adequate drainage diagram for correct installation method.
- This form may be updated at any time due to product improvements, please check the online installation form for the most current version.
Steps for Installation: HV1843T
- Make sure that the electrical circuit is free of voltage (master switch off)
- Make a hole where the fitting is to be placed using dimensions provided on line drawings, making sure adequate drainage is allowed.
- Insert the canister, and ensure that the top is level with the ground or floor. Failure to do so will void the warranty.
- Using an appropriate 12v DC LED Driver – DO NOT CONNECT LIGHT FITTING DIRECTLY TO 240V
- Connect the cable – If more than one fitting is installed, wiring must be done in parallel.
- Strip back the cable on both fitting and cable run and twist the positive cables together. Then connect neutral cables together
- Solder all joins using solder and either a heat gun or butane gas torch.
- over connections using an adhesive-lined heat shrink or gel cap to make the connection watertight. Failure to do this will void the warranty.
- Heat the heat shrink or crimp the gel cap making sure all connections are covered.
- Make sure the seals are still in place and screws are tight to avoid any water penetration.
- Fitting is preset to 3000k, locate cap on the bottom of fitting and remove by twisting anti-clockwise, Slide switch to desired color temperature, and Reattach cap making sure it is tight.
- Insert fitting into the canister.
- Apply silicon around the edge of the fitting to prevent any water from getting inside to electrical connections.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Steps for Installation: HV1843RGBW
-
Make sure that the electrical circuit is free of voltage (master switch off)
-
Make a hole where the fitting is to be placed using dimensions provided on line drawings, making sure adequate drainage is allowed.
-
Insert the canister, and ensure that the top is level with the ground or floor. Failure to do so will void the warranty.
-
Connect the cable –
-
Use an appropriate 12v DC LED Driver and RGBW LED Controller- DO NOT CONNECT LIGHT FITTING DIRECT TO 240V
-
Do this by stripping back the cable on both fitting and cable run and twisting the cable together making sure all colors are correctly joined to the correct color-
• Black= Positive
• Red = Red
• Green = Green
• Blue = Blue
• White = White -
Solder all joins using solder and either a heat gun or butane gas torch.
-
Cover connections using an adhesive-lined heat shrink or gel cap to make the connection watertight. Failure to do this will void the warranty.
-
Heat the heat shrink or crimp the gel cap making sure all connections are covered.
-
Connect cable run to RGBW Controller.
-
Connect the RGBW Controller to a 12v DC LED Driver.
-
Apply silicon around the edge of the fitting to prevent any water from getting inside to electrical connections.
-
All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Steps for Installation: HV1843-F-SH
- Remove nuts on the back of the fitting and set aside
- Remove cover and replace with security face
- Reattach nuts and tighten making sure seals are still in place
- Insert fitting into the canister
- Insert screws and tighten
Must be installed by a licensed electrician
**Warranty Terms & Conditions*** | Additional Information |
---|
|
https://havit.com.au/pages/warranty-terms-and-conditions|
https://havit.com.au/
Contact Details:
143 Beauchamp Road
Matraville NSW 2036
Australia
Tel: 02 9381 8300
Fax: 02 9666 8881
Email: sales@havit.com.au
Web: www.havit.com.au
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>