HUMAN CARE 89009 Rollator Fellow Classic User Manual

June 9, 2024
HUMAN CARE

HUMAN CARE 89009 Rollator Fellow Classic

HUMAN-CARE-89009-Rollator-Fellow-Classic-PRODUCT

Rollator Fellow Classic

Important!
You must read the user manual for your device prior to usage. Keep this booklet and information handy for future use.

Symbols

  • WARNING symbol indicates a poten-tially hazardous situation which, if not avoided, could result in serious injury to the user or damage to property and/or the device itself.
  • INFORMATION symbol indicates recommendations and information for proper, trouble-free usage.
  • WEIGHT CAPACITY symbol indicates maximum user weight for the product. Do not exceed this weight in any circumstance.
  • CE MARKING symbol indicates product meets requirements of EU Directive 93/42/EEC (MDD) and/or EU Regulation 2017/745 (MDR).
  • MEDICAL DEVICE symbol indicates that the product is a medical device according to the definition of medical device in EU Directive 93/42/EEC (MDD) and/or EU Regulation 2017/745 (MDR).
  • RECYCLE according to local regulations.
  • READ INSTRUCTIONS and ensure you fully understand them before using this product.

Product modification is not per-mitted. Before use, always check that the sling is not damaged or worn.

Human Care’s products are continuously being developed and updated to provide our customers with the highest quality. We reserve the right to make design changes without prior notice. Always make sure that you have the most recent version of the manual which is available for downloading from our website at www.humancaregroup.com.

Contact your local distributor if you have any questions about the product and its use.

Notice to user/patient in case of serious incident
Any serious incident that has occurred in rela-tion to the product, should be reported to the local contact, who reports to the manufacturer, and the competent authority of the country in which the user/patient is established.

Compliances and Standards

Human Care is an ISO 13485:2016 certified Swedish medical device company. The Quality Management System is in compliance with US 21 CFR part 820. The product is CE marked in accordance with EU

About our products

On delivery
Check the following before using your new product:

  1. Check that no damage has occurred during transport (if this is the case, please immedia-tely inform the delivery agent).
  2. Check that the number and type (s) of products detailed on the delivery certificate agree with the goods delivered.
  3. Check that the delivery is of the desired model and type of product.

Please contact us immediately in case of any delivery problem.

Return or refund
If any product has to be returned for any rea-son, please contact us to obtain a claim number and advice on how to proceed. The goods should be returned in complete and undamaged condition in their original packa-ging. Directive 93/42/EEC (MDD) and/or EU Regula-tion 2017/745 (MDR), as class I medical device. The CE mark is on the product. This product has been tested in accordance with ISO 11199-2:2005. The following information should accompany any product on its return. The product’s identifi-cation number, delivery date, the date the user took possession of the aid, the date of the pro-duct’s last service, the person whom we should contact about the fault, whether it be the user or another, and the nature of the fault. Human Care HC AB reserves the right to inspect the returned product. If no fault can be found, the item will be returned to the user. Transport costs may then be chargeable.

Product lifetime
The product´s expected lifetime is seven (7) years, if the product is used as intended and maintained according to the manufacturer´s instructions, depending on the intensity of use and maximum load applied during use. If the product label is no longer legible, the product should be discarded.HUMAN-
CARE-89009-Rollator-Fellow-Classic-FIG-1 HUMAN-CARE-89009-Rollator-Fellow-Classic-FIG-2

Additional Warnings

  • Ensure that all bolts are securely faste-ned before using the rollator!
  • DO NOT adjust brake tension until whe-els lose molding sheen!
  • Brakes must be in the parked/locked position before sitting on the rollator!
  • DO NOT hang anything on backstrap or it may break!

Safety
In the instruction manual, three ways of drawing special attention are used. These ways are highligh-ted in the following manner.

  • Warning!
    Risk of personal injury or mechanical fault.

  • Important!
    Risk of mechanical damage or fault.

  • Note!
    Important information to improve handling.

Recycling of products
When recycling, the product’s chassis is separated from other parts. At separation, the parts can be sorted according to material after unscrewing and dimantling rivets and other connections. The diffe-rent parts should be separated into metal, plastic or combined materials. The products consist mainly of steel pipe and other metal components. Examples of parts witch consist of combined materials, are the front fork including bearings wheel with bearing.

Note!
Different authorities/recycling companies handle recycled materials in different ways. It is thus fitting when in any doubt over the best way to proceed when recycling, to contact the relevant governing body.

Environmentally friendly
Human Care HC AB aids are manufactured to have as little effect on the environment as possible during their lifetime. This allows for the used product to be dismantled and for its parts to be recycled. Products with lengthy lifecycles safeguard our sensitive environment and are thus more environmentally friendly. Human Care HC AB is a part of REPA. REPA – A countrywide system for recycling of packaging.

Intended use.

Fellow Classic is an easily used walking aid which is suitable for use both in- and outdoors. Unfolding and folding are achieved with simply used handles. This safety walker is available in five varieties with differing heights and widths. See below.

Technical data

HUMAN-CARE-89009-Rollator-Fellow-Classic-FIG-4

Rollator

**Article no.***

| ****

Min.

| ****

Max.

| Seat height| ****

Width

| Seat width| ****

Length

| ****

Wheel size

| Weight (kg)| ****

LxBxH (Min.)

| Standard (kg)
---|---|---|---|---|---|---|---|---|---|---
Fellow Classic
89009 Standard| 770| 950| 590| 630| 440| 700| 200×40| 8,0| 860x630x290| 150
89109 Low| 680| 805| 505| 620| 440| 610| 200×40| 7,7| 760x620x290| 140
89309 Wide| 770| 950| 600| 690| 500| 700| 200×40| 8,7| 850x690x290| 150
89509 Narrow| 770| 950| 600| 595| 440| 700| 200×40| 8,1| 850x595x290| 130
89609 High| 820| 1000| 640| 625| 440| 700| 200×40| 8,1| 910x625x290| 130

(All measurements in mm)

  • When ordering, make an addition after the part number for the package size, QX, where Q is for qua-lity and X for the size of the package. Please see www.humancaregroup.com for more information.

Accessories

Accessories| Model| Article no.|
---|---|---|---
Basket with

handles

| Standard| 08805| Max load 10 kg
Low| 88051
Wide, Narrow, High| 88052
Tray| | 08806| Max load 2 kg
Bag| Standard, Narrow, Wide| 08808| Max load 2 kg
Low| 88081
Cane holder| | 10603|
Back support| | 10668|
Oxygen holder| | 08811| Max load 5 kg
Slow down break| | 10625|
IV stand| Standard| 08814| Max load 3 kg
One-hand break| Right| 10677|
Left| 10678|
Cerb climber| | 08813|

See respective assembly instruction.

Table 1. Possible accessory combinations

HUMAN-CARE-89009-Rollator-Fellow-Classic-FIG-6

User guide

  • Read all warnings and instructions carefully before using the rollator.
  • Ensure that the rollator is properly unfolded before use.
  • The rollator may only be used as a support for walking or sitting.
  • Never stand on the rollator.
  • Do not use the product on stairs or escalators.
  • Be extra careful when using the rollator on slopes or uneven surfaces.
  • Never sit on the rollator and roll yourself forward with your feet.
  • Distribute weight evenly to prevent the rollator from tipping when you sit on it.
  • lways set the parking brake before using the rollator for support while sitting down or getting up.
  • Do not place anything on a folded up rollator when it is in storage or being transported as this may cause damage to it.
  • Do not store the rollator close to a heat source as this could cause damage to some details.
  • Be careful when you handle the rollator if it has been exposed to abnormally high or low temperatures to avoid injuries.
  • Do not store the rollator outdoors.
  • Save the user instructions for future use.

Unfolding
Pull the locking frame under the seat until the rollator automatically unfolds and locks.

Important! Check that the red catch falls of its own weight.

Folding

  1. Lift red catch.
  2. Pull locking frame up. The rollator folds automatically.
  3.  Fold stand together until the rollator locks folded.

Adjustment of handles
Loosen wing nuts and adjust the handles to wrist height. Tighten the wing nuts. Sideways angle of the handles : 3° inwards.

Parking brake
Push brake lever down to brake when stationary.

Important!
Engage parking brake before sitting.

Brake
Pull brake lever up to brake whilst travelling.

Important!
handles must not be heightened above the”MAX” mark on the sides of the handle pipes. The handles must be pointing straight forward. The handle pipe numbers must be aligned with the slit at the side of the pipes to avoid unstableness and dangerous situations.

Warning! The handles must not be pointing outwards because of increased tip risk.

  • On assembly of the wingnut component, it is im-portant that the base of the screw head engages fully the groove in the recess.

Note!
The brakes consists of one brake handle for each wheel, where the right brake handle affects the right wheel, and the left brake handle affects the left wheel. The brake handle pulls a wire that runs in a wire housing. The wire pulls a brake gear that affects the wheel. When a single hand brake is used, one brake handle affects both wheels.

Brake adjustment
Loosen locking nut; adjust brake by loosening/tightening the adjustment casing. After adjust-ment tighten locking nut.

Note! Continuous braking leads to excessive wear of wheels and brakes.

Cleaning and service

Important!
When changing parts of the rollator, use only Human Care parts to ensure continued CE vali-dation.

Important!
Do not alter the rollator yourself.

Important!
Check the rollator regularly to ensure its continued safety to the user.

Regular checks should be carried out as recommended by the instructions detailed in 99210. For more information on servicing, reconditioning , spare parts and accessories, see Human Care’s website: www.humancaregroup.com or contact us at the address, phonenumber or e-mail address according to back page.

Warranty

Human Care HC AB has high demands on our product quality and our warranty cover material and manufacturing faults of our products. The warranty is not covering wear and tear on wheel, brakes, handles grips and surface damages arisen after delivery. The warranty is valid if the product is used in the intended way and the maintenance instructions have been followed. The product identity needs to be readable. The product shall not have been modified or changed in any way after the delivery from Human Care. The warranty time is 1 year if noting else has been stated in contract. In case of product complaint please contact us for further instructions. The following information is needed to create a product complaint: Id number of the product, date for when the last maintenance were performed, customer contact person and failure description..

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals