DC-DC CHARGER AP20DC
USER MANUAL
V3.1
AP20DC DC-DC Charger
ABOUT US
ATEM POWER, born in June 2017, as a synonym for exciting outdoor experience,
is an Australian company with dedication and passion for the R&D of high
quality products in the field of renewable energy products, batteries and
related accessories.
Since the company was founded, we have committed to innovation that aims to
make your life infinitely more convenient. And the belief in our conviction
for quality and commitment allows us to innovate in developing products that
are optimally tailored to the needs of our amazing customers.
We engineer and supply solar products for homes, 4x4s, recreational vehicles
and virtually any application you can think of. And we also develop reliable,
high performing deep-cycled batteries and lithium batteries for standby or
daily power needs. Accessories include battery chargers and inverters that are
ideal for RV’s, commercial vehicles, boats, yachts and many more applications!
At ATEM POWER, we stay true to our DNA by prioritizing technological
innovation designed to improve our products and striving to provide excellent
customer care. Because we are motivated to explore the limits of solar power!
IMPORTANT SAFETY INSTRUCTIONS !
- Children or adults under the influence of alcohol or drug, or those who lack of experience or professional knowledge are not allowed to use this unit.
- The user must read and understand all of the warning and safety messages supplied with your product prior to installation or use.
- Do not use or store this charger near heat sources such as fire or heaters or expose it to flammable chemicals, vapors or corrosive gases.
- Please only use this product as intended.
- Do not strike, throw the charger.
- Do not mount the product in places where there is a risk of gas explosion.
- Inadequate ventilation may lead to overheat and inefficient charging.
- Please do not expose the charger to moisture or harsh environments.
- This product should be firmly fastened to prevent fall down or tip over.
- Please do not disassemble this charger as such action will not only cause potential damage to you and your unit, but also void the warranty.
- Please note that this DC-DC charger is not waterproof.
- Please disconnect the charger before maintenance or cleaning.
- This DC-DC charger can only be repaired by professional personnel.
- Before charging, please wear proper eye protections.
- Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention.
- Do not smoke or have an open spark or fire near this unit.
- Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit which goes through the battery or another electrical tool that may create an explosion.
- Examine the battery charger regularly for damage. If the battery charger is damaged, it must not be used until it has been repaired.
KEY FEATURES
This DC-DC charger by ATEM POWER, which is ideal for 4WDs, caravans, RVs, trucks, campers, trailers, campervans, commercial vehicles and boats, offers an effective way to charge your auxiliary batteries from the alternator or solar panel (up to 20A) to charge LiFePO4 and lead acid: AGM,Gel & calcium batteries. It also has a built-in MPPT regulator to maximize energy absorption, thus reducing the load on your engine. And over-charge, short circuit, over-temperature, solar input overload, input/output reverse polarity protection have been integrated to offer an extra layer of protection. Furthermore, the charger allows you to re-select the battery during charging by long pressing “POWER”, and LED indicator showing stage of charging. And memory function is integrated to make charging more convenient.
STAGE OF CHARGING
(1) Qualification | (2) Recondition |
---|---|
(3) Bulk | (4) Absorption |
(5) Full and Analysis | (6) Recharge |
PACKING LIST
IDENTIFICATION OF PARTS
INSTALLATION INSTRUCTIONS
- Please check whether the specification of your cable is compatible with this DC-DC charger.
- This charger can be installed both horizontally and vertically.
- Please make sure that the charger is installed as close as possible to the battery you are going to charge, and you also need to make sure that the areas is not susceptible to moisture, water, dust or high temperatures.
- Please ensure that there is no heat source or flammable gas around the unit.
- Anderson plug is recommended when this charger is installed on a caravan or a campers (see picture below).
- Twin core cable will be used between the start battery and the charger, and you need to connect the common negative and common positive wires from the starter battery to the input of the DC-DC in the appropriate positive and negative terminals.
- It is highly recommended to install a 40 Amp circuit breaker (not included in this package) that should be installed near the starter battery.
- Check whether all connections are clean and tight.
- You can connect the optional ACC line to the ignition of your vehicle, then turn your key to the ACC position when engine starts, which will be detected by the DC-DC charger. And the main battery will start charging your auxiliary battery.
Note: the charger may discharge your main battery if the ACC line is connected but you key is not turned to the START position.
HOW TO USE
1. DC Battery
-
Start your vehicle and let it idle.
-
And the charger will recognize that there is a charge being applied to the main starting battery.
-
The charger will charge the auxiliary battery when the main starting battery has reached 13V (ACC line not connected). The main battery will start charging the auxiliary battery when its voltage is or above 11.5V (ACC line connected).
-
Press “POWER” to re-select batteries (The default setting is for lead acid battery, and your setting will be saved once selection is made).
-
The charger will continue to operate even after the vehicle has been switched off, however when the main starting battery falls below 12.5V the charger will automatically shut off (ACC line not connected). When the main starting battery falls below 10.8V, the charger will automatically shut off (ACC line connected).
2. Solar Input -
The charger will shift to solar charge mode when the input terminal is connected to the solar panel.
-
Press “POWER” to select the corresponding battery type, and batteries can be re-selected during charging by long pressing the button.
-
Charging begins when the output of solar panel reach 16V~25V, and the panel will stop to charge when its output is below 10V.
Note: This charger is not designed to charge your auxiliary battery with
DC inputs and solar concurrently, DC enjoys input priority over solar. When
the voltage drops to 13.2V for LiFePO4 battery/12.3V for AGM, Gel & Calcium
after a full charge, a recharge will begin.
Wake-up of Lithium-Ion Batteries in Sleep Mode: this DC-DC charger cannot
charge a lithium-ion battery in sleep mode. To charge the lithium-ion battery,
first make sure the DC-DC charger is correctly connected to the battery. Then
select the “LiFePo4” mode, and long press “POWER” for 5s. The “charging” (red)
indicator will flash for 10s. If the battery is successfully waken up, the
“charging” (red) indicator will be constantly on and the DC-DC charger begins
to charge the battery. Otherwise, the DC-DC charger will enter the standby
state and the “Power On” indicator will be on.
DEEP CYCLE BATTERY MAINTENANCE
- This DC-DC charger by ATEM POWER will be used to charge your auxiliary battery, for example, deep cycle batteries that are designed to provide power for your fridges and light in caravan or camper.
- Your fridge might use appropriately 24AH per day. In this light, if your 100AH battery is only used to power your fridge while receiving no charge, and it would require charging after 48 hours.
- To replenish the capacity of the battery (100AH capacity, 50AH discharged), you may need to use a 40amp DC-DC charger that would further require at least 1.25 hours of driving/solar charging. A 30 amp unit will require at least 1.67 hours of driving/solar charging to fully recharge the battery. A 20 amp unit will require at least 2.5 hours of driving/solar charging to fully recharge the battery.
BATTERY WIRING
This diagram is for a reference only. Local rules and regulations should be followed when installing this unit. NOTE: First connect the ACC line to the ignition of your vehicle. Then turn your key to the ACC position when engine starts, which will be detected by the DC-DC charger. And your auxiliary battery will be charged via the main battery.
TROUBLESHOOTING
- Display shows that the charger is not charging: check where the battery is connected; check the terminals; check whether the battery is 12V.
- Battery is not charging: check whether all connections are connected correctly; check the status of the battery; check the status of your vehicle or solar panel.
- Battery cannot be fully charged or power cannot be maintained: please check whether your battery has been used for over 3 years; overheat; low in electrolyte; over- charging or battery vulcanized; You need to consult your battery manufacturer to check its condition or make a replacement.
TECHNICAL SPECIFICATIONS
Model: | AP20DC |
---|---|
Type | Multi Stage |
Input | DC Battery:13.0 -16.0 Volts Solar Input:16.0 – 25.0 Volts |
Output / Charging Voltage | 14.4 – 15.4 Volts ( Stops charging when vehicle |
battery below 12.5V without ACC line connected/below 10.8V with ACC line
connected )
Output Current| DC Output:20A Solar Output:20A
Minimum Start Voltage| 2.5 Volts – For battery being charged
Charge Control
Soft Start| YES
Soft Charge Current| 20A
Bulk Charge Voltage| 14.7V (AGM/Gel)14.4(Lead Acid)15.4(Calcium)14.4V(LiFePO4)
Absorption| Constant voltage with automatic amperage control
Equalisation| Automatic
Float Charge Voltage| 13.5 (AGM/Gel)13.5V(Lead Acid)13.5V(Calcium)
Float Charge Current| 0-20A
Battery Range| 60 to 600Ah
Cable Length / Twin C
0 – 1 Meters| 10AWG
1 – 5 Meters| 8 AWG
5 Meters +| 6 AWG
CHARGING VOLTAGE
| AGM/GEL| LEAD ACID| CALCIUM| LiFePO4
---|---|---|---|---
BOOST| 14.3 V| 14.0 V| 15.0 V| 14.0 V
CHARGING| 14.7V| 14.4 V| 15.4 V| 14.4 V
MAINTENANCE| 13.5 V| 13.5 V| 13.5 V|
CHARGING ALGORITHM
NOTE: Charging voltage is specified by your battery manufacturer. Non observance of instructions will void the warranty of your battery.
WARRANTY
WARRANTY PERIOD:
Full 12 months warranty from date of purchase against all manufacturing
defects.
This DC-DC charger by ATEM POWER comes with guarantees that cannot be excluded
under the Australian Consumer Law.
WHAT DOES THE WARRANTY COVER?
Under normal usage conditions, this warranty covers:
- Any defect in design or manufacture which results in its failure to perform correctly as described.
- We will either repair or replace the product at our discretion provide that the fault is found to have been caused by a design or manufacturing defect and not misuse or tampering.
- The limited warranty is the only one that applies to this unit, and it sets forth all the responsibilities of ATEM POWER.
THE WARRANTY DOES NOT COVER:
- Cost of removing and reinstalling the product.
- Travel and /or other expenses due to customer’s location
- Transport charges and damage in transit. It is your responsibility to deliver and pick up your product, including any costs associated with the postage of repairing or replacing your product. If you want to send the product back we recommend that you insure against loss or damage.
- Any loss directly or indirectly associated with the product that fails to operate.
- Damage caused by mould, misuse, incorrect operation, adverse weather, accidents and daily wear and tear.
- The warranty does not extend to subsequent purchasers or users other than OEM applications.
- This unit is not intended for commercial use. This warranty does not apply to damage to units from misuse or incorrect installation/connection. Misuse includes wiring or connecting to improper polarity power sources.
Read User Manual Online (PDF format)