CELESTRON 81057 NexYZ DX 3-Achsen Smartphone Adapter Kit Instruction Manual
- June 9, 2024
- Celestron
Table of Contents
CELESTRON 81057 NexYZ DX 3-Achsen Smartphone Adapter Kit
USING YOUR SMARTPHONE ADAPTER
- CONNECT THE ADAPTER
- FOR TELESCOPES, BINOCULARS, AND SPOTTING SCOPES
- Squeeze the lever to open the clamp. Position the clamp around the eyepiece and release. Tighten the safety lock.
- FOR MICROSCOPES
- Choose one of the two provided adapter rings that best fits your microscope’s eyepiece and secure it in place. (You may need to remove the eyepiece from the microscope to install the ring.) Then, follow the instructions above.
- ATTACH YOUR PHONE
- NexYZ works with regular phone cases, but you will need to remove “folio-style” cases. Extend the slider. Place your phone on the platform, making sure the bottom is touching the rubber base. Release the slider. Your phone is now secure and ready for imaging.
- ALIGN AND SHOOT
- Open your camera app. Position your phone over the eyepiece using the X and Y axis knobs. Then, use the Z axis knob to move closer or further away from the eyepiece until you have achieved your desired framing. Finally, adjust the focus using the focuser on your optics and snap the image.
For more tips and tricks, visit: celestron.com/NexYZ- tips
NEXYZ TENSION ADJUSTMENT GUIDE
The tension of each axis can be easily adjusted using a small Phillips screwdriver. Use the images above to locate the adjusting screws. For each axis, only make small adjustments to the set screws. Tightening them too much can make it difficult to use the motion knobs.
X-Axis
Adjust the Z axis until the phone platform is as far away from the adapter as possible. Look down onto the NexYZ in between the platform and adapter, there will be two set screws for tension adjustment in the X axis.
Y-Axis
On the platform there is a handle to pull the slider to install your phone. Underneath the handle will be two set screws for tension adjustment in the Y axis.
Z-Axis
Directly on the opposite side of the Z axis motion knob are the set screws for tension adjustment in the Z-Axis. This adjustment is very useful for heavy smartphones.
USING THE BLUETOOTH REMOTE
- To insert or replace the battery, place your thumb in the center of the back cover, pressing inward and sliding downward remove the battery door. The CR2032 battery should be inserted with the positive (+) side facing upward. Replace the cover.
- Press and hold the button on the remote for 5 seconds. A blue light will turn on and, after a few seconds, start to blink. The remote is now in pairing mode.
- Using the Bluetooth settings on your phone, pair the device called “GBshutter”.
- Open your camera app. Press the button on the remote to trigger the shutter on your phone.
- If your camera is in video mode, you can press the button once to start recording and again to stop the recording.
BATTERY WARNING: KEEP OUT OF REACH OF CHILDREN
Swallowing can lead to chemical burns, perforation of soft tissue, and death. Severe burns can occur within 2 hours of ingestion. Seek medical attention immediately.
SAFETY INSTRUCTIONS
- Risk of explosion if battery is replaced by an incorrect type.
- The included battery is not rechargeable.
- Please use the battery in its original purpose to avoid causing the battery to short circuit. When the conductive material is connected directly to the battery positive and negative will cause a short circuit.
- Do not use a damaged battery.
- Keeping the battery in an extremely cold or very hot location can result in shortened battery life.
- When replacing the battery, please refer to the instruction manual and pay attention to the positive and negative direction of battery.
- Do not put the battery in the fire. Dispose of the battery according to local regulations.
FCC STATEMENT
FCC IDENTIFIER: 2A2FG-93974
_ NOTE: _FCC certification is for the Bluetooth Remote Control included with this product.
Model # 93974
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on acircuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Tel: 08145/80890
service@celestron-deutschland.de
©2022 Celestron. Celestron and Symbol are trademarks of Celestron, LLC.
All rights reserved.
Celestron.com
(Products or instructions may change without notice or obligation.) Designed and intended for those 14 years of age and older.
References
- Celestron - Telescopes, Telescope Accessories, Outdoor and Scientific Products
- Celestron - Telescopes, Telescope Accessories, Outdoor and Scientific Products
- Smartphone Adapter Imaging Tips and Tricks | Celestron
- Technical Support | Celestron
- Warranty | Celestron
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>