falmec FPVUX36W6SSR 36 Inch Stainless Steel Convertible Chimney Style Wall Mount Hood Instruction Manual
- June 9, 2024
- falmec
Table of Contents
Design
Vulcano XL wall
FPVUL24W3SS / FPVUL30W3SS / FPVUL36W3SS
FPVUX30W6SS-R / FPVUX36W6SS-R
INSTRUCTIONS BOOKLET
VULCANO 24″ FPVUL24W3SS
VULCANO 30″ FPVUL30W3SS
VULCANO 36″ FPVUL36W3SS
VULCANO XL 30″ FPVUX30W6SS-R
VULCANO XL 36″ FPVUX36W6SS-R
Installation measurements
Recommended mounting height from cooking surface to hood bottom is indicated by “A” in the drawing below. It is recommended to install the hood in this range to optimize performance. It is recommended to not exceed 35” (890mm) for dimension “A” as hoods mounted above this may be difficult to reach for average height users and performance and efficiency will degrade. Hoods mounted below the lower measurement in the “A” recommendation could result in damage due to heat and present a fire hazard and would avoid any warranty claims attributable to the lower mounting position. If available, also refer to the cooking appliance manufacturer’s height clearance recommendations and adhere to national and local building and fire codes which supersede any recommendations stipulated herein.
A = 24″ – 35″ 610 mm – 890 mm (RECOMMENDED FOR OPTIMAL PERFORMANCE)
Tool required
Hood fastening (1), check valve installation and suction pipe assembly (3).
Flue assembly.
Optional filter assembly
SAFETY INSTRUCTIONS AND WARNINGS
READ AND SAVE THESE INSTRUCTIONS
Installation operations are to be carried out by skilled and qualified
installers in accordance with the instructions in this booklet and in
compliance with the regulations in force.
DO NOT use the hood if the power supply cable or other components are damaged:
disconnect the hood from the electrical power supply and contact the Dealer or
an authorised Servicing Dealer for repairs.
Do not modify the electrical, mechanical or functional structure of the
equipment.
Do not personally try to carry out repairs or replacements. Interventions
carried out by incompetent and unauthorised persons can cause serious damage
to the unit or physical and personal harm, not covered by the Manufacturer’s
warranty.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or
Explosive Materials And Vapors.
WARNINGS FOR THE INSTALLER
TECHNICAL SAFETY
Before installing the hood, check the integrity and function of each part.
Should anomalies be noted, do not proceed with installation and contact the
Dealer.
Do NOT install the hood if an aesthetic (or cosmetic) defect has been
detected. Put it back into its original package and contact the dealer. No
claim can be made for aesthetic (or cosmetic) defects once it has been
installed.
During installation, always use personal protective equipment (e.g.: Safety
shoes) and adopt prudent and proper conduct.
The installation kit (screws and plugs) supplied with the hood is only to be
used on masonry walls: in case of installation on walls of a different
material, assess other installation options keeping in mind the type of wall
surface and the weight of the hood (indicated on page 2).
Keep in mind that installations with different types of fastening systems from
those supplied, or which are not compliant, can cause electrical and
mechanical seal danger.
Do not install the hood outdoors and do not expose it to atmospheric elements
(rain, wind, etc.).
All set screws must be checked, and retightened where necessary, before
installation.
CAUTION: To Reduce The Risk Of Fire And Electric Shock, Install This Rangehood Only With Remote Blower Or Integral Blowers Manufactured by FALMEC S.p.A. Models “Remote in-roof Blower”.
ELECTRICAL SAFETY
The installation has to be in accordance with the National Electrical Code,
ANSI/NFPA 70 and local codes. Making sure the power is off before attempting
installation.
The electrical system to which the hood is to be connected must be in
accordance with local standards and supplied with earthed connection in
compliance with safety regulations in the country of use. It must also comply
with European standards regarding radio antistatic properties.
WARNING: GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire for
the electric current. This appliance is equipped with a cord having a
grounding wire with a grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of electric shock. Consult a
qualified electrician if the grounding instructions are not completely
understood, or if doubt exists as to whether the appliance is properly
grounded. Do not use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the appliance.
Before installing the hood, check that the electrical mains power supply
corresponds with what is reported on the identification plate located inside
the hood.
The socket used to connect the installed equipment to the electrical power
supply must be within reach: otherwise, install a mains switch to disconnect
the hood when required.
Any changes to the electrical system must be carried out by a qualified
electrician.
The maximum length of the flue fastening screws (supplied by the manufacturer)
must be 1/2″ (13 mm). Use of non-compliant screws with these instructions can
lead to danger of an electrical nature.
Do not try to solve the problem yourself in the event of equipment
malfunction, but contact the Dealer or an authorised Servicing Department for
repairs.
When installing the hood, disconnect the equipment by removing the plug or
switching off the main switch.
WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan
With Any Solid-State Speed Control Device
WARNING: NOT SUITABLE FOR USE WITH SOLID-STATE SPEED CONTROLS
FUMES DISCHARGE SAFETY
Do no connect the equipment to discharge pipes of fumes produced from
combustion (for example boilers, fireplaces, etc.).
Before installing the hood, ensure that all standards in force regarding
discharge of air out of the room have been complied with.
To reduce risk of fire and to properly exhaust air, be sure to duct air
outside – Do not vent exhaust air into spaces within walls or ceilings or into
attics, crawl spaces, or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
USER WARNINGS
These warnings have been drawn up for your personal safety and those of
others. You are therefore kindly asked to read the booklet carefully in its
entirety before using the or cleaning the equipment. The Manufacturer declines
all responsibility for any damage caused directly, or indirectly, to persons,
things and pets as a consequence of failing to comply with the safety warnings
indicated in this booklet. It is imperative that this instructions booklet is
kept together with the equipment for any future consultation.
If the equipment is sold or transferred to another person, make sure that the
booklet is also supplied so that the new user can be made aware of the hood’s
operation and relative warnings.
After the stainless steel hood has been installed, it will need to be cleaned
to remove any residues remaining from the protection adhesive as well as any
grease and oil stains which, if not removed, can cause irreversible damage to
the hood surface. To properly clean the unit, the manufacturer recommends
using the supplied moist wipes, which are also available sold separately.
Insist on original spare parts.
State of California Proposition 65 Warning (US only)
WARNING
This product contains chemicals known to the State of California to cause
cancer and birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
INTENDED USE
The equipment is solely intended to be used to extract fumes generated from
cooking food in non-professional domestic kitchens: any other use is improper.
Improper use can cause damage to persons, things, pets and exempts the
Manufacturer from any liability.
The equipment can be used by children over the age of 8 and by persons with
reduced physical, sensory and mental abilities, or with no experience or
knowledge, as long as they do so under supervision or after
having received relative instructions regarding safe use of the equipment and
understanding of the dangers connected to it.
Children are not to play with the equipment. Cleaning and maintenance by the
user must not be carried outby children without supervision.
USE AND CLEANING WARNINGS
WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low or
medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the
surface element.
WARNING:TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING a :
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then
turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a violent steam
explosion will result.
d) Use an extinguisher ONLY if:
- You know you have a Class ABC extinguisher, and you already know how to operate it.
- The fire is small and contained in the area where it started.
- The fire department is being called.
- You can fight the fire with your back to an exit. a Based on “Kitchen Firesafety Tips” published by NFPA.
Before cleaning or carrying out maintenance operations, disconnect the equipment by removing the plug or switching off the main switch.
Do not use the hood with wet hands or bare feet. Always check that all
electrical parts (lights, extractor fan) are off when the equipment is not
being used. The maximum overall weight of any objects placed or hung (if
applicable) on the hood must not exceed 3lb 5oz. (1.5 Kg).
Always supervise the cooking process during the use of deep-fryers: Overheated
oil can catch fire.
Do not leave open, unattended flames under the hood.
Do not prepare food over an open flame under the hood.
Never use the hood without the metal anti-grease filters: in this case, grease
and dirt will deposit in the equipment and compromise its operation.
Accessible parts of the hood can be hot when used at the same time as the
cooking appliances.
Do not carry out any cleaning operations when parts of the hood are still hot.
There can be a risk of fire if cleaning is not carried out according to the
instructions and products indicated in this booklet.
Disconnect the main switch when the equipment is not used for long periods of
time.
If other appliances that use gas or other fuels are being used at the same time (boiler, stove, fireplaces, etc.), make sure the room where the fumes are discharged is well-ventilated, in compliance with the local regulations.
INSTALLATION
Intended only for qualified personnel
Before installing the hood, carefully read the chapter ‘SAFETY INSTRUCTIONS AND WARNINGS’.
TECHNICAL FEATURES
The technical specifications are exhibited on the labels located inside the
hood.
POSITIONING
The minimum distance between the highest part of the cooking equipment and the
lowest part of the hood is indicated in the installation instructions.
Should the instructions for the gas cooker specify a greater distance, this
must be taken into consideration.
Do not install the hood outdoors and do not expose it to outdoor environment
(rain, wind, etc.).
ELECTRICAL CONNECTION
(Intended only for qualified personnel)
Disconnect the equipment from electrical mains power supply before carrying
out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut: in the
event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in
force.
Before connecting the hood to the electrical mains power supply, check that:
- voltage supply corresponds with what is reported on the data plate located inside the hood;
- the electrical system is compliant and can withstand the load (see the technical specifications located inside the hood);
- the power supply plug and cable do not come into contact with temperatures exceeding 158°F (70 °C);
- the power supply system is effectively and properly connected to earth in compliance with regulations in force;
- the socket used to connect the hood is within reach. In case of:
- devices fitted with cables without a plug: the type of plug to use is a ”standardised” one. The wires must be connected as follows: yellow-green for grounding, blue for neutral and brown for the live. The plug must be connected to an adequate safety socket.
- fixed equipment not provided with a power supply cable and plug, or any other device that ensures disconnection from the electrical mains, with an opening gap of the contacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance with installation regulations.
The cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the
safety regulations.
FUMES DISCHARGE
EXTERNAL EXHAUST HOOD (SUCTION)
In this version the fumes and vapours are discharged outside through the
exhaust pipe.
To this end, the hood outlet fitting must be connected via a pipe, to an
external output.
The outlet pipe must have:
- a diameter not less than that of the hood fitting.
- a slight slope downwards (drop) in the horizontal sections to prevent condensation from flowing back into the motor.
- the minimum required number of bends.
- the minimum required length to avoid vibrations and reduce the suction performance of the hood.
You are required to insulate the pipes if it passes through cold environments. In the presence of motors with 500 CFM or higher, a check valve is present to prevent external air flowing back.
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, the air passes through the charcoal filters to be purified and
recycled in the environment.
Ensure that the active carbon filters are assembled into the hood, if not,
install them as indicated in the assembly instructions.
In this version the check valve must not be assembled: remove it if it is on
the air outlet fitting of the motor.
ASSEMBLY INSTRUCTIONS
Intended only for qualified personnel
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for each case, follow
the specific steps provided for the required installation.
SRS SYSTEM SETTING
The SRS system reduces the maximum air flow rate that can be set in the hood.
This makes the hood compliant with local building regulations.
MAX SPEED LEVEL 3
Apply the label
Fig. 1: Set maximum speed 3:
Press keys for 5 seconds
All keys flash.
Within 5 seconds, press and hold the key for 5 seconds If all the keys light
up and are steady, the setting procedure has been successful.
MAX SPEED LEVEL 2
Apply the label
Fig. 2: Set maximum speed 2:
Press keys for 5 seconds. All keys flash.
Within 5 seconds, press and hold the key for 5 seconds If all the keys light
up and are steady, the setting procedure has been successful.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes
and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all
vapours and odours. By means of the Timer function, it is possible to set auto
switch-off function which will allow the hood to turn off automatically after
15 minutes of operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity
consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation. The active
carbon filters must be replaced every 3-4 months, depending on the use of the
hood. For further details refer to the “MAINTENANCE” section.
USE OF MECHANICAL PUSH BUTTON CONTROL PANEL (VULCANO 24″ – FPVUL24W3SS)
| Light on/off
---|---
OFF| OFF button
Press this button to switch the motor off
1| Button 1: Press this button (button in) to start or set the motor at
minimum speed
2| Button 2: Press this button (button in) to start or set the motor at medium
speed
3| Button 3: Press this button (button in) to start or set the motor at
maximum speed
ELECTRONIC PUSHBUTTON PANEL
| Motor ON/OFF
---|---
| Increase speed from 1 to MAX
Maximum speed with SRS disabled: Speed 4 is only active for a few minutes,
then it goes back to speed 3.
Maximum speed with SRS enabled: Speed 3 or speed 2.| The speeds are indicated
by the LEDs on the keys:
| Reduce speed from 4 to 1
| Light on/off
Short impulse: turn light on and off
| TIMER (red LED flashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if: – The TIMER key ( ) is pressed
again. – The ON/OFF key ( ) is pressed.
If the pushbutton panel is completely inactive, before contacting the
Technical assistance service, disconnect power temporarily to the appliance
(about 5“), possibly by acting on the main switch, to restore normal
operation.
If this measure has no effect, contact the Technical assistance service.
MAINTENANCE
Before cleaning or carrying out maintenance operations, disconnect the
equipment by removing the plug or switching off the main switch.
Do not use detergents containing abrasive, acidic or corrosive substances or
abrasive cloths.
Regular maintenance guarantees proper operation and performance over time.
Special attention is to be paid to the metal anti-grease filters : frequent
cleaning of the filters and their supports ensures that no flammable grease is
accumulated.
CLEANING OF EXTERNAL SURFACES
You are advised to clean the external surfaces of the hood at least once every
15 days to prevent oily substances and grease from sticking to them. To clean
the brushed stainless steel hood, the Manufacturer recommends using “Magic
Steel” wipes.
Alternatively and for all the other types of surfaces, it can be cleaned using
a damp cloth, slightly moistened with mild, liquid detergent or denatured
alcohol. Complete cleaning by rinsing well and drying with soft cloths.
Do not use too much moisture or water around the push button control panel and
lighting devices in order to prevent humidity from reaching electronic parts.
The glass panels can only be cleaned with specific, non-corrosive or non-
abrasive detergents using a soft cloth.
The Manufacturer declines all responsibility for failure to comply with these
instructions.
CLEANING OF INTERNAL SURFACES
Do not clean electrical parts, or parts related to the motor inside the hood,
with liquids or solvents.
For the internal metal parts, see the previous paragraph.
METAL ANTI-GREASE FILTERS
It is advised to frequently wash the metal filters (at least once a month)
leaving them to soak in boiling water and cleaning solution for 1 hour, taking
care not to bend them.
Do not use corrosive, acid or alkaline detergents.
Rinse them well and wait for them to be completely dry before reassembling
them.
Washing in a dishwasher is permitted, however, it may cause the filter
material to darken: to reduce the possibility of this problem from happening,
use low-temperature washes (131°F / 55°C max.).
To extract and insert the metal anti-grease filters see the assembly
instructions.
ACTIVE CARBON FILTERS
These filters retain the odours in the air that passes through them. The
purified air is recirculated into the environment.
The active carbon filters must be replaced on average every 3-4 months under
normal conditions of use.
See assembly instructions to replace the active carbon filters.
LIGHTING
The range hood is equipped with high efficiency, low consumption LED
spotlights with an extremely long life-span under normal use conditions.
Should the LED spotlight need to be replaced, proceed as shown in the figure.
DISPOSAL AFTER END OF USEFUL LIFE
The crossed-out trash or refuse bin symbol on the appliance means that the
product is WEEE, i.e. “Waste electrical and electronic equipment”, accordingly
it must not be disposed of with regular unsort- ed waste (i.e. with ”mixed
household waste”), but it must be disposed of separately so that it can
undergo specific processing for its re-use, or a specific treatment, to remove
and safely dispose of any substances that may be harmful to the environment
and remove the raw materials that can be recycled. Proper disposal of these
products contributes to saving valuable resources and avoid potential negative
effects on personal health and the environment, which may be caused by
inappropriate disposal of waste. You are kindly asked to contact your local
authorities for further information regarding the designated waste collection
points nearest to you.
Penalties for improper disposal of such waste can be applied in compliance
with national regulations.
INFORMATION ON DISPOSAL IN NON-EUROPEAN UNION COUNTRIES
The crossed-out trash or refuse bin symbol is only valid in the European
Union: if you wish to dispose of this appliance in other countries, we suggest
contacting your local authorities or dealer to find out what the correct
method of disposal is.
WARNING!
The Manufacturer reserves the right to make changes to the equipment at any
time and without prior notice. Printing, translation and reproduction, even
partial, of this manual are bound by the Manufacturer’s authorisation.
Technical information, graphic representations and specifications in this
manual are for information purposes and cannot be divulged.
This manual is written in Italian. The Manufacturer is not responsible for any
transcription or translation errors.
Falmec S.p.A
via dell’Artigianato, 42 z.i. 31029 Vittorio Veneto Treviso — Italy
info@falmec.com
falmec.com
Code
Serial Number
Code 110033046 Ed. 01/2022
References
- www.ca.gov | California State Portal
- Cappe da Cucina Aspiranti e Filtranti - Made in Italy | Falmec.com
- Mack Energy Corporation - Commited to Our Community and Your Tommorow
- P65Warnings.ca.gov
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>