PRODUCT

Important safety instructions

READ CAREFULLY AND STORE FOR FUTURE USE.

  • This vacuum cleaner may be used by children 8 years of age and older and by persons with physical, sensory, or mental impairments or by inexperienced persons, if they are properly supervised or have been informed about how to use this vacuum cleaner in a safe manner and understand the potential dangers.
  • Children must not play with the vacuum cleaner. Cleaning and maintenance performed by the user must not be performed by unsupervised children.

WARNING: This appliance contains a UV-C light. Do not look into the light of the UV-C lamp and do not point the UV-C lamp at eyes.

  • If the power adapter is damaged, it must be replaced with an original type. For a replacement power adapter, please contact an authorised service centre. It is forbidden to use the appliance if it has a damaged power adapter.

WARNING: Avoid coming into contact with the rotating parts of the vacuum cleaner‘s hand accessories. There is a risk of getting caught on these parts and possible injury.
Only use the vacuum cleaner with the original power adapter, charging base and accessories that were supplied with it.

  • This vacuum cleaner is designed for use in households, offices and similar types of areas. Do not use in industrial surroundings.
  • Do not expose the vacuum cleaner to direct sunlight and do not place it near an open fire or appliances that are a source of heat.
  • Before connecting the adapter to a power socket, check that the technical details on its rating label match the electrical voltage in the power socket.
  • Make sure the adapter power cord is not touching a hot surface or sharp objects. Position the adapter power cord so that it will not be tripped over.
  • Never submerge the vacuum cleaner, the charging base and the power adapter in water or any other liquid and do not wash under running water.
  • Before turning on the vacuum cleaner, make sure that all the inflow and outflow filters are installed in their place.
  • When the vacuum cleaner is running, ensure that the air outlets and the suction hole are not blocked.
  • Do not use the vacuum cleaner to vacuum the following items:
    • smouldering cigarettes, burning items, matches or embers;
    • water and other liquids;
    • flammable or volatile materials;
    • items, e.g. broken glass, needles, pins, etc.;
    • flour, wall plaster, cement and other building materials;
    • larger pieces of paper or plastic bags, which can easily block the suction hole.
  • Vacuuming of some types of floors or floor surfaces can create an electrostatic discharge, which presents no danger to the user.
  • Always turn off the vacuum cleaner when leaving it without supervision, after finishing using it and before cleaning it.
  • Disconnect the power adapter from the power socket before cleaning it and after it has finished charging.
  • Disconnect the power adapter from the power socket by pulling on the plug, never pull on the power cord. Otherwise, this could damage the power adapter or the socket.
  • If the power adapter is damaged, it must be replaced with an original type. For a replacement power adapter, please contact an authorised service centre.
  • Do not use the vacuum cleaner if it is not working correctly if it has been damaged or has been submerged in water.
  • Do not repair the vacuum cleaner yourself or make any adjustments to it. Have all repairs performed at an authorised service centre. By tampering with the appliance, you risk voiding your legal rights arising from unsatisfactory performance or quality warranty.

DESCRIPTION OF THE VACUUM CLEANER

DESCRIPTION OF THE MOTOR UNIT

SENCOR-SVC-0725BK-4-In-1-Versatile-Cordless-Vacuum-Cleaner-
FIG-1

  • A1 Output hole of the motor unit
  • A2 Dust container release button
  • A3 Inflow filter cover
  • A4 Inflow filter
  • A5 Speed button
  • A6 On / Off button
  • A7 Handle
  • A8 Charging battery light
  • A9 Power adapter socket
  • A10 Rechargeable battery
  • A11 Outer filter
  • A12 Tube filter
  • A13 Transparent dust container
  • A1 4 Release button of the dust container bottom for quick removal of dirt
  • A15 Battery release button
  • A16 Lock to release the motor unit
  • A17 Metal tube
  • A18 Floor nozzle
  • A19 Lock to release the floor nozzle
  • A20 Protective cover
  • A21 Electric rotary brush
  • A22 Castors
  • A23 Lock
  • A24 Side cover to remove the rotary brush

DESCRIPTION OF THE ACCESSORIES

SENCOR-SVC-0725BK-4-In-1-Versatile-Cordless-Vacuum-Cleaner-
FIG-2

  • B1 Cat&Dog motorised mini brush
  • B2 Lock to release the mini brush
  • B3 Protective cover
  • B4 Rotary brush lock
  • B5 UV-C light
  • B6 Castors
  • B7 Rotary brush
  • B8 Combined crevice nozzle
  • B9 Crevice nozzle brush
  • B10 Button to slide out / back the brush
  • B11 Combined attachment for upholstery and furniture
  • B12 Attachment brush
  • B13 Button to slide out / back the brush
  • B14 Soft brush
  • B15 Articulated connector
  • B16 Flexible hose
  • B17 Holder
  • B18 Power adapter
  • B19 Wiping attachment
  • B20 Water tank
  • B21 Tank lid
  • B22 Water control button

Not shown: Wall plug Screws

ASSEMBLY AND DISASSAMBLY OF THE VACUUM CLEANER
  1. ASSEMBLY AND DISASSAMBLY OF THE STICK VACUUM CLEANER
    Place the floor nozzle A18 on a flat, dry and stable surface. Attach the tube A17 to the floor nozzle so that the connectors at the back of the floor nozzle A18 are aligned with the holes inside the tube A17 – see picture C1. Push the tube A17 until it clicks. Insert the output hole A1 of the motor unit into the tube A17 so that the connectors at the back of the tube A17 are aligned with the holes inside the outlet hole A1 – see picture C2. When you need to disassemble the stick vacuum cleaner, press the lock A16 to release the motor unit. Then press the lock A19 to release the floor nozzle A18.

  2. ASSEMBLY AND DISASSEMBLY THE WIPING ATTACHMENT
    Assemble the stick vacuum cleaner – see the previous part of the manual. Attach the sleeve to the bottom surface of the attachment B19 and put the attachment on the floor. Place the vacuum cleaner above the wiping attachment B19 so that the protrusion on the attachment B19 is aligned with the hole on the bottom surface of the floor nozzle A18. Gently push the vacuum cleaner until it clicks. That signalizes the correct connection of the attachment B19 to the floor nozzle A18. When you need to remove the attachment B19 from the vacuum cleaner, carefully hold the attachment B19 by one hand and pull thevacuum cleaner upwards until the floor nozzle A18 is released from the attachment B19.

ASSEMBLY AND DISASSEMBLY OF THE VACUUM CLEANER WITH ACCESSORIES
To ensure perfect cleaning of your home, you can attach any of the supplied accessories to the output hole A1 of the motor unit. Simply remove the accessory by pulling it out of the output hole A1 of the motor unit. Press the lock B2 first to remove the mini brush B1.

  1. Cat&Dog motorized mini brush Cat&Dog motorized mini brush is the ideal helper for removing animal fur, hair, etc., while at the same time being suitable for vacuuming hard-to-reach places. Its use is not limited to the home and can be used for vacuuming the car. It quickly and effectively removes hair, animal fur and other materials from car seats, upholstery, pillows, and other textile surfaces.
  2. Combined crevice nozzle It is suitable for vacuuming hard-to-reach places (e.g., window frames, corners, libraries, spaces between mattresses, upholstery, etc.). Press and hold the B10 button and move forward to slide the brush out. Press the B10 button and move backward to slide the brush back.
  3. Combined attachment for upholstery and furniture The attachment is suitable for vacuuming surfaces, such as furniture or upholstery. Press and hold the B13 button and move forward to slide the brush out. Thanks to the soft bristles, the attachment is ideal for removing dirt from fine surfaces, such as net curtains, curtains, etc. Press B13 button and move backward to slide the brush back.
  4. Soft brush It is ideal for vacuuming dirt and dust from fragile objects, libraries, walls, blinds, etc.
  5. Articulated connector and flexible hose Attach the articulated connector B15 or flexible hose B16 to the output hole A1 when you need to extend the reach of the used accessory, e.g., you need to vacuum dust on the wardrobe.

Note: Picture D shows the possibilities how to combine the accessories.

ASSEMBLY AND DISASSEMBLY OF THE VACUUM CLEANER
  1. ASSEMBLY AND DISASSEMBLY OF THE STICK VACUUM CLEANER
    Place the floor nozzle A18 on a flat, dry and stable surface. Attach the tube A17 to the floor nozzle so that the connectors at the back of the floor nozzle A18 are aligned with the holes inside the tube A17 – see picture C1. Push the tube A17 until it clicks. Insert the output hole A1 of the motor unit into the tube A17 so that the connectors at the back of the tube A17 are aligned with the holes inside the outlet hole A1 – see picture C2. When you need to disassemble the stick vacuum cleaner, press the lock A16 to release the motor unit. Then press the lock A19 torelease the floor nozzle A18.

  2. ASSEMBLY AND DISASSEMBLY THE WIPING ATTACHMENT
    Assemble the stick vacuum cleaner – see the previous part of the manual. Attach the sleeve to the bottom surface of the attachment B19 and put the attachment on the floor. Place the vacuum cleaner above the wiping attachment B19 so that the protrusion on the attachment B19 is aligned with the hole on the bottom surface of the floor nozzle A18. Gently push the vacuum

CHARGING THE BATTERY
The battery A10 can be charged either installed in the motor unit orremoved. Insert the connector of the power adapter B18 into the socket A9 and insert the adapter plug into the power socket. The light A8 turns red. The charging time usually takes 4 – 5 hours. The battery A10 is charged once the light A8 turns green. Then disconnect the connector of the power adapter A18 from the socket A9 and remove the plug from the power socket.

Note:
Once the battery A10 is almost discharged, the operation of the vacuum cleaner will automatically stop to prevent the battery A10 from being completely discharged.In order to ensure the long life of the battery A10, it is advised to fully charge the battery A10 before the first use and to discharge before the second charging (operation of the vacuum cleaner will automatically stop).

Tip:
This vacuum cleaner contains a built-in Li-ion battery. To ensure the longest possible lifetime of the battery, we recommend:

  • do not unnecessarily leave the battery fully charged or completely flat for too long,
  • do not keep the battery permanently fully charged. Its lifetime will be extended by keeping it at approximately half charge.
  • do not fully discharge the battery.

INSERTING AND REMOVING THE BATTERY

  1. Inserting the battery: Carefully turn the motor unit upside down and insert the fully charged battery A10 so that the battery A10fits into the connective grooves – see picture E. Push the battery A10 until it clicks. The battery A10 can only be inserted with one side.
    Warning: Never insert the battery A10 in the opposite way or with great force. There is a risk of damage.

  2. Removing the battery: When you need to remove the battery A10, press the A15 button to release the battery A10. Carefully remove it from the motor unit.
    Warning: If you do not use the vacuum cleaner for a long time, remove the battery A18 from it and store it in a cold and dry place. Charge the battery regularly. Keep it away from the reach of metal objects to prevent excessive discharge.

Note: Regularly check the water/solution level in the water tank B20 and fill it up as necessary.

When no longer using the wiping attachment B19, turn off the vacuum cleaner and press button B22 and it will click down. This will prevent air from entering the water tank and the water will stop flowing out. Pull the vacuum cleaner out in the upward direction

Tip: We recommend that you wet the wiping sleeve before attaching it to the attachment. This will speed up the wetting process and wiping will be more effective from the very beginning.

Storage under normal use
The vacuum cleaner SVC 0725BK is supplied with a holder B17 which can be fixed on the wall. Choose the place where the holder B17 will be easily accessible and there will be free space around it.Mounting the holder on the wall

  1. Put the holder B17 on the wall and using a pencil, mark the points where it is necessary to drill the holes.
  2. Drill two holes which you insert the wall plugs into.
  3. Place the holder B17 to the wall and insert the screws into the holes in the holder. Use a screwdriver to fix them. Make sure the holder B17 does not move and the screws are properly tightened.
    Warning: Never install the holder B17 in environments with high huminidity or dustiness.

Storage of the motor unit and accessories

The holder B17 is designed to store the motor unit and accessories in it. Insert the motor unit into the holder B17 and you can attach the selected accessories you use the most often to two pins – see the picture F.

USING THE STICK VACUUM CLEANER

  1. Assemble the vacuum cleaner according to the instructions in the section “ASSEMBLY AND DISASSAMBLY OF THE STICK VACUUM CLEANER”.
  2. Insert the fully charged A10 into the motor unit.
  3. Press the On / Off button A6 and the vacuum cleaner turns on.
  4. You can adjust the speed using the A5 button. Press the A5 button repeatedly to switch the speed as following:
  5. (low speed – ensures longer vacuuming time)
  6. (high speed – vacuuming at high power)
  7. (turbo speed – vacuuming at maximum power)
  8. When vacuuming is completed, press the On / Off button A6 and the vacuum cleaner turns off.
    Note: Electric rotary brush A21 will automatically stop once it is blocked by, e.g., a foreign object or large amount of hair or animal hair. It is a safety feature that prevent the brush from damage. In such case, turn the vacuum cleaner off by pressing the On / Off button A6 and remove the blocked object or hair from the brush A21.

Using the vacuum cleaner with wiping attachment
Place the wiping attachment B19 with the attached sleeve on the floor. Remove the lid B21 and pour water or cleaning solution into the water tank B20. Put the lid B21 back.

Note: Always use a neutral cleaning agent with low foaming effect.

Attach the vacuum cleaner to the attachment B19. In order to vacuum and wipe the floor simultaneously, press button B22 and it will click up. This will result in water slowly flowing into the sleeve. Turn the vacuum cleaner on, and while vacuuming you will also wipe the floor.

Note: Regularly check the water/solution level in the water tank B20 and fill it up as necessary.

When no longer using the wiping attachment B19, turn off the vacuum cleaner and press button B22 and it will click down. This will prevent air from entering the water tank and the water will stop flowing out. Pull the vacuum cleaner out in the upward direction.

Tip: We recommend that you wet the wiping sleeve before attaching it to the attachment. This will speed up the wetting process and wiping will be more effective from the very beginning.

Storage under normal use
The vacuum cleaner SVC 0725BK is supplied with a holder B17 which can be fixed on the wall. Choose the place where the holder B17 will be easily accessible and there will be free space around it.

Mounting the holder on the wall

  1. Put the holder B17 on the wall and using a pencil, mark the points where it is necessary to drill the holes.
  2. Drill two holes which you insert the wall plugs into.
  3. Place the holder B17 to the wall and insert the screws into the holes in the holder. Use a screwdriver to fix them. Make sure the holder B17 does not move and the screws are properly tightened.

Warning: Never install the holder B17 in environments with high huminidity or dustiness.

Storage of the motor unit and accessories
The holder B17 is designed to store the motor unit and accessories in it. Insert the motor unit into the holder B17 and you can attach the selected accessories you use the most often to two pins – see the picture F.

CLEANING AND MAINTENANCE

Before cleaning, always make sure the vacuum cleaner is switched off. Remove the battery A10 from the motor unit.
Cleaning the motor unit and accessories
Use a soft cloth, lightly dampened in a lukewarm water, to clean the outer parts of the vacuum cleaner. Do not use abrasive cleaning agents, solvents, or dissolving agents, otherwise the unit surface may be damaged.

Cleaning the stick vacuum cleaner

Empty the dust container
It is advised to empty the dust container A13 after each use. However, if the dirt level reaches the MAX mark, it is necessary to empty the dust container A13 immediately.

SENCOR-SVC-0725BK-4-In-1-Versatile-Cordless-Vacuum-Cleaner-
FIG-5

  1. Remove the accessory from the motor unit.
  2. Place the motor unit above the waste bin with the dust container bottom facing down.
  3. Press the A14 button and the dust container bottom is released and opens – see picture G1.
  4. This will empty the container content directly into the waste bin.
  5. Use your hand to close the container bottom. It clicks once correctly fitted.

Cleaning the dust container
Clean the dust container A13 regularly to prevent unpleasant odours.

  1. Remove the accessory from the motor unit and empty the dust container A13 according to the instructions above.

  2. Press the A2 button to release the dust container and at the same time, turn the container A13 until the arrow on the motor unit points at the symbol. Carefully remove it from the motor unit – see picture G2.

  3. Wipe the inner walls of the dust container A13 using a light dampened soft sponge. Dry with a clean cloth.

  4. Turn the outer filter A11 until the arrow on the filter A11 points at the symbol to release the outer filter A11. Carefully remove it from the motor unit downwards – see picture G3. Remove the tube filter A12 from the motor unit downwards – see picture G4.

  5. Remove the dirt from both filters. If necessary, you can wash them under the running clean water. And then dry them with clean cloth.
    Warning: Never insert wet or damp filters A22 and A12 into the motor unit! Always wait until it is completely dry.

  6. Attach the tube filter A12 to the motor unit.

  7. Attach the outer filter A11 to the motor unit so that the arrow on the filter A11 is aligned with the symbol. Then turn the filter A11 until the arrow on the filter A11 points at the symbol and it clicks.

  8. Attach the container A13 to the motor unit so that the arrow on the motor unit is aligned with the symbol. Turn until the arrow on the motor unit points at the symbol. Correct securing of the container A13 is signalised by a click.

Cleaning and change of the inflow filter
It is advised to clean inflow filter A4 regularly to ensure proper vacuum cleaner operation. Depending on how often you use the vacuum cleaner, change the inflow filter A4 once every 3 or 6 months.

SENCOR-SVC-0725BK-4-In-1-Versatile-Cordless-Vacuum-Cleaner-
FIG-6

  1. Take the cover A3 and pull it upwards.
  2. Turn the filter A4 clockwise to release it – see picture G5.
  3. Remove the dirt from the filter A4 over the waste bin. If the filter A4 is heavily soiled, rinse it under running clean water – see picture G6. Leave it to dry.
  4. Insert the filter A4 to the bottom of the cover A3 by aligning the protrusions on the filter A4 with the grooves inside the cover A3. Turn the filter A4 counter clockwise until you feel resistance.
  5. 5. Insert the cover A3 with installed filter A4 into the motor unit.

Cleaning the floor nozzle
It is necessary to clean the floor nozzle A18 regularly to ensure the desired and stable suction power.

  1. Remove the floor nozzle A18 from the vacuum cleaner and turn it upside down.
  2. Move the lock A23 up to remove the side cover A24 – see picture G7. Remove it.
  3. Carefully remove the rotary brush A21 – see picture G8.
  4. Remove tangled hair, animal hair and other dirt from the rotary brush A21. You can use scissors to remove tangled hair or animal hair quicker.
  5. Clean the inner part of the floor nozzle A18 by a dry cloth.
  6. Insert the clean rotary brush A21 into the floor nozzle A18.
  7. Finally, attach the side cover A24.

Cleaning the wiping attachment
Always empty out the tank B20 after every use of the attachment B19. Wipe the attachment B19 with a soft sponge lightly dampened in warm water. Wipe dry using a clean wiping cloth.
Remove the sleeve and wash it by hand in cold water. Allow it to dry naturally.
Warning: Under no circumstances submerge or wash the attachment B19 in water or any other liquid.

  1. Remove the rotary brush B1 from the vacuum cleaner and turn it upside down.
  2. Turn the lock B4 to release the brush and take it out.
  3. Remove tangled hair, animal hair and other dirt from the brush. You can use scissors to remove tangled hair or animal hair quicker.
  4. Clean the inner part of the rotary brush B1 by a dry cloth.
  5. Place the brush back and turn the lock B4 until it clicks.

Storage

  • If you do not use the vacuum cleaner, clean it according to the instructions above and remove the battery A10 from the motor unit.
  • Before storing, make sure the vacuum cleaner and all accessories are clean and dry.
  • Store the appliance on a dry, clean and well-ventilated place where it will not be exposed to extreme temperature and out of reach of children or animals.
  • It is advised to regularly charge the battery A10 every 6 months.

TROUBLESHOOTING

Before you decide to contact an authorised service centre, please read through the following table:

Problem Possible cause Solution
Vacuum cleaner does not work. Battery A10 is discharged. Charge the

battery A10 before using the vacuum cleaner.
Suction hole is blocked.| Remove the dirt from the suction hole.
Vacuum cleaner is not correctly assembled.| Make sure all the parts are correctly assembled.
Suction power is low.| Dust container A13 is full, or the filters A11 and A12 are soiled.| Empty the dust container A13 and clean the filters A11 and A12.
A large amount of hair or animal hair is wound on the rotary brush A21.| Clean the rotary brush

A21.

Short operation time of battery A10 after charging.| Battery A10 is not fully charged.| Fully charge the battery A10.
| Battery A10 is at the end of its life.| Buy a new battery A10.
The wiping attachment B19 does not wipe immediately when the vacuum cleaner is turned on.| The wetting of the sleeve may take several seconds.| We recommend that you wet the wiping sleeve before attaching it to the attachment.

Cautions: If you cannot find your problem in the table above, or the problem persists, stop using the vacuum cleaner, turn it off and contact the authorised service centre.

TECHNICAL SPECIFICATIONS

Adapter

  • Input……………………………………………………………..100 – 240 V~, 50/60 Hz, 0.8 A
  • Output………………………………………………………………………………..30 V , 0.6 A
  • Electric shock protection class ………………………………………………………………………. II

Vacuum cleaner

  • Power input……………………………………………………………………………………………..400 W
  • Electric rotary brush………………………………………………………………………………….30 W
  • Cat&Dog electric rotary brush……………………………………………………………………5 W
  • Battery…………………………………………………….Li-Ion / 25.2 V / 2,500 mAh
  • Time required for charging to full capacity………………………approx.4 – 5 hours
  • Operating time when fully charged…………………………………………….up to 50 min
  • Noise level…………………………………………………………………………………………≤ 83 dB(A)
  • Dust container capacity………………………………………………………………………….. 0.58 l
  • Water tank capacity………………………………………………………………………………… 0,25 l

The declared noise emission level of vacuum cleaner is ≤ 83 dB(A), which represents level A of acoustic power with respect to a reference acoustic power of 1 pW. We reserve the right to change text and technical specifications.

  • Electric shock protection class
  • Class II – Electrical shock protection is provided by double or heavy-duty insulation.
  • The product is intended for household use only. The product is not intended for outdoor use.
  • Thoroughly read the all the instructions before using the product.

DISPOSAL

DISPOSAL OF BATTERIES

Prior to disposing of the product or handing it over at a specialised collection facility, it is necessary to ensure that the battery is removed. Before removing the battery, it is necessary to start the vacuum cleaner and wait until it is completely flat. The battery contains environmentally damaging substances and therefore does not belong in standard household waste. Their correct disposal will be performed by the respective collection facility.

INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING MATERIALS
Dispose of used packaging material at a site designated for waste in your municipality.

DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT

This symbol on products or original documents means that used electric or electronic products must not be added to ordinary municipal waste. For proper disposal, renewal and recycling, hand over these appliances to determined collection points. Alternatively, in some European Union states or other European countries you may return your appliances to the local retailer when buying an equivalent new appliance. Correct disposal of this product helps save valuable natural resources and prevents potential negative effects on the environment and human health, which could result from improper waste disposal. Ask your local authorities or collection facility for more details. In accordance with national regulations penalties may be imposed for the incorrect disposal of this type of waste.

  • For business entities in European Union states
  • If you want to dispose of electric or electronic equipment, ask your retailer or supplier for the necessary information.
  • Disposal in other countries outside the European Union.
  • This symbol is valid in the European Union. If you wish to dispose of this product, request the necessary information about the correct disposal method from the local council or from your retailer.

This product meets all the basic requirements of EU directives related to it.

FAST ČR, a.s. U Sanitasu 1621 CZ-251 01 Říčany www.sencor.eu