testo 810 2 Channel Infrared Thermometer Instruction Manual

June 9, 2024
testo

testo 810 2 Channel Infrared Thermometer

OVERVIEW

  1. Protection cap: Park position
  2. Infrared sensor
  3. Air/temperature sensor
  4. Display
  5. Control keys
  6. Battery compartment (on rear)

Basic settings

Instrument off >press and hold 2s > select with ,
confirm with :
Unit of temperature: °C, °F > Differential temperature Dt: OFF, ON > > Auto off-Funktion: OFF, ON

Switching the instrument on Press
Switching the display light on (for 10s) Instrument on > press .
IR measurements
Press and hold .
Select display mode

Instrument on > select with :
Hold: Readings are held > Max: Maximum values > Min: Minimum values Switching the instrument off:
Instrument on >press and hold 2s.

Safety and the environment

About this document

Please read this documentation through carefully and familiarise yourself with the product before putting it to use. Keep this document to hand so that you can refer to it when necessary. Hand this documentation on to any subsequent users of the product.
Pay particular attention to information emphasised by the following symbols:
Important.

**Avoid personal injury/damage to equipment

**

Only operate the measuring instrument properly, for its intended purpose and within the parameters specified in the technical data. Do not use force.
Never store the product together with solvents, acids or other aggressive substances.
Only carry out the maintenance and repair work that is described in the documentation. Follow the prescribed steps when doing so. Use only OEM spare parts from Testo.

Protecting the environment

Take faulty rechargeable batteries as well as spent batteries to the collection points provided for them.
Send the product back to Testo at the end of its useful life. We will ensure that it is disposed of in an environmentally friendly manner.

Specifications

Functions and use

The testo 810 is an infrared measuring instrument. It is normally used to measure surface temperature, e.g. on heaters and radiators, and to measure the ambient temperature at the same time.

Technical data

Measurement data

  • Sensors: Infrared sensor, NTC temperature sensor

  • Parameters: °C, °F

  • Measuring ranges: IR: -30…300 °C, -20…575 °F, Air probe: -10…50 °C, 14…122 °F

  • Resolutions: 0.1 °C, 0.1 °F,

  • Accuracies (Nenntemperatur 22 °C, ±1 Digit): Infrared: ±2 °C (-30…+100 °C), ±3.6 °F (-22…212 °F), ±2 % of reading (rest of range) Air probe: ±0.5 °C, ±0.9 °F

  • Measuring rate: 0.5 s

  • Optics: 6 : 1

  • Emissivity: adjustable from 0.2 to 0.99

  • Laser

  • Class 2

  • Power: <1 mW

  • Wavelength: 645 to 660 nm

  • Standard: DIN EN 60825-1:2001-11 Further instrument data

  • Protection class : IP40

  • Ambient conditions: -10…50 °C, 14…122 °F

  • Storage/transport conditions: -40…70 °C, -40…158 °F

  • Voltage supply: 2x 1.5 V type AAA

  • Battery life : 50 h (without display light)

  • Dimensions: 119x46x25mm / 4.7×1.8×1.0 in (inc. protection cap)

  • Weight: 90 g / 3.2 oz (inc. batteries and protection cap)
    Directives, standards and tests

  • EC Directive: 2014/30/EU
    Warranty

  • Duration: 2 years, warranty conditions: see www.testo.com/warranty

Product description

At a glance

Product description

  1. Protection cap: Park position
  2. Infrared sensor
  3. Air/temperature sensor
  4. Display
  5. Control keys
  6. Battery compartment (on rear)

First steps

▷Inserting batteries:

  1. To open the battery compartment, push the battery cover down.
  2. Insert batteries (2x 1.5 V type AAA). Observe the polarity!
  3. To close the battery compartment, push the battery cover back on.

▷ Basic settings (configuration mode): Adjustable functions

  • Unit of temperature: °C, °F
  • Differential temperature Dt: OFF, ON
  • Emission factor: e · Auto off function: OFF, ON (instrument switches off automatically if no key is pressed for 10 minutes)
    The emission factor has a default setting of 0.95. This is ideal for the measurement of non-metals (paper, ceramic, gypsum, wood, paints and varnishes), plastics and foodstuffs.

Because of their low or non-uniform emission factor, bright metals and metal oxides are of only limited use for infrared measurement. Coatings that increase the emission factor, e.g. paint or emission adhesive (0554 0051) must be applied to the object being measured.
Emission factors of various materials (typical values):

Material (temperature) e Aluminium, bright rolled (170 °C) 0.04
Cotton (20 °C) 0.77
Concrete (25 °C) 0.93
Ice, smooth (0 °C) 0.97
Iron, emery ground (20 °C) 0.24
Iron with casting skin (100 °C) 0.80
Iron with rolling skin (20 °C) 0.77
Gypsum (20 °C) 0.90
Glass (90 °C) 0.94
Rubber, hard (23 °C) 0.94
Rubber, soft grey (23 °C) 0.89
Wood (70 °C) 0.94
Cork (20 °C) 0.70
Radiator, black anodised (50 °C) 0.98
Copper, slightly tarnished (20 °C ) 0.04
Copper, oxidised (130 °C) 0.76
Plastics: PE, PP, PVC (20 °C) 0.94
Brass, oxidised (200 °C) 0.61
Paper (20 °C) 0.97
Porcelain (20 °C) 0.92
Black paint, matt (80 °C) 0.97
Steel, heat-treated surface (200 °C) 0.52
Steel, oxidised (200 °C) 0.79
Clay, burnt (70 °C) 0.91
Transformer paint (70 °C) 0.94
Brick, mortar, plaster (20 °C) 0.93

  1. When switching the instrument on, press and hold until  and  appear on the display (configuration mode).
    ● The adjustable function is displayed. The current setting flashes.

  2. Press several times until the desired setting flashes.

  3. Press to confirm the input.

  4. Repeat steps 2 and 3 for all functions.
    ● The instrument changes to measuring mode.

Using the product

▷ Switching the instrument on:

Press .
– Measuring mode is opened.
▷ Switching the display light on:
****The instrument is switched on.
Press .
– The display light goes out automatically if no key is pressed for 10 seconds.
▷ IR measurements:

Laser radiation! Do not look into the laser beam. Laser class 2.

To ensure correct readings:

  • Keep temperature and humidity sources which may falsify the measurement (e.g. hands) away from the sensor.
  • Keep the lens clean and do not measure with foggy lenses.
  • Keep the measuring range (the range between the instrument and the object being measured) and the surface of the object free of obstacles. There must be no particles of dust or dirt, no humidity (rain, steam) and no gases.
  • If the ambient temperature changes (change of location, e.g. measurement indoors/outdoors), the instrument must be allowed to equalise for aprox. 15 minutes.
  • The instrument has a lens (90 % value) of 6:1 (distance : measuring surface) + Opening diameter of the sensor (10mm / 0.39 in):

Distance Diameter of meas. surface| Distance Diameter of meas. surface
---|---
10cm| 3cm| 4 in| 1.06 in
60cm| 11cm| 25 in| 4.56 in
100cm| 18cm| 40 in| 7.06 in
200cm| 35cm| 80 in|

Press and hold .
– flashes in the display. The laser dot marks the centre of the measuring surface.
– When IR measurement has been completed (release  ), the instrument changes to the Hold display view and the eadings are held.
▷ Changing the display view: Adjustable views

  • Hold: Readings are held.
  • Max: Maximum values since the instrument was last switched on or last reset.
  • Min: Minimum values since the instrument was last switched on or last reset.

    Press several times until the desired view appears.

▷Resetting Max/Min values:

  1. Press several times until the desired view appears.
  2. Press and hold until – – – – appears.
  3. Repeat steps 1 and 2 for all values that are to be reset.

▷Switching the instrument off:

Press and hold until the display goes out.

Maintaining the product

▷Changing batteries:

  1. To open the battery compartment, push the battery cover down.
  2. Remove used batteries and insert new batteries (2x 1.5 V type AAA). Observe the polarity!
  3. To close the battery compartment, push the battery cover back on.

▷ Cleaning the housing:

Clean the housing with a moist cloth (soap suds) if it is dirty. Do not use aggressive cleaning agents or solvents!

Tips and assistance

Questions and answers

Question Possible causes/solutions
Hi or Lo · Readings outside the measuring range (too high, too low): Keep to

the permitted measuring range.
| Residual capacity

If we could not answer your question, please contact your dealer or Testo Customer Service. For contact details, please visit www.testo.com/service- contact

Testo SE & Co. KGaA
Celsiusstraße 2
79822 Titisee-Neustadt
Germany
Telefon: +49 7653 681-0
E-Mail: info@testo.de
Internet: www.testo.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals