DIMENSIONS

 | ****


Description

|

External

| Internal| ****

Guard weight

---|---|---|---|---


Height

| ****

Width

| ****

Depth

| ****

Height

| ****

Width

| ****

Depth

677048

|

CCG3002/CUBO –

CUBO2Smart LT cage

| ****

1150mm

| ****

2000mm

| ****

1150mm

| ****

1120mm

| ****

1970mm

| ****

1120mm

| ****

80kg

677049

|

CCG3001/CUBO –

CUBO2Smart HT cage

| ****

1150mm

| ****

1650mm

| ****

1150mm

| ****

1120mm

| ****

1620mm

| ****

1120mm

| ****

60kg

COMPONENTS

  • A : Mounting Frame x 1 Nos
    COMPONENTS

  • B : Aluminium Arm x 4 Nos
    COMPONENTS

  • C : End Panel x 2 Nos

  • D : Top Panel x 1 Nos
    COMPONENTS

  • E : Front/Rear or Side Panel (depending on installation method) x 1 Nos
    COMPONENTS

  • F : Floor Mounting Feet x 4 Nos

NB The required components are dependent on the installation method; not all components are required for all methods

FIXINGS

  • F : M8 x 20mm Hexagonal Headed Bolt x 8

  • G : Spring Washer x 4

  • H : Wall Anchor Bolt x 4

  • I : Hexagonal Key x 1
    FIXINGS
    FIXINGS

FLOOR STANDING UNIT INSTALLATION INSTRUCTIONS – OPTION 1

  1. Using 4 x hexagonal headed bolts and 4 x spring washers, bolt the arms to the wall mount / floor mount frame.
  2. Using the fixings provided, secure the floor mounted fixing feet to the frame.
  3. Using the anchor bolts provided, if suitable, secure the frame and feet assembly to the floor surface.
  4. Carefully slide the end panels within the arms into position on  the frame assembly.
  5. Carefully slide the side panels within the arms into position on the frame assembly.
  6. Using 4 x hexagonal headed bolts provided, secure the top panel to the guard assembly.
    FIXINGS

FLOOR STANDING UNIT INSTALLATION INSTRUCTIONS – OPTION 2

  1. Using 4 x hexagonal headed bolts and 4 x spring washers, bolt the arms to the rear panel.
  2. Using the fixings provided, secure the floor mounted fixing feet to the underside of the arms closest to the floor.
  3. Using the anchor bolts provided, if suitable, secure the rear panel, arm and feet of the guard assembly to the floor surface.
  4. Carefully slide the end panels within the arms into position on the guard assembly.
  5. Carefully slide the top panel within the arms into position on the guard assembly.
  6. Using 4 x hexagonal headed bolts provided, secure the front panel to the guard assembly.
    FIXINGS

WALL MOUNTED UNIT INSTALLATION INSTRUCTIONS

  1. Using 4 x hexagonal headed bolts and 4 x spring washers, bolt the arms to the wall frame.
  2. Using the wall fixings bolts if suitable, secure the wall frame to the wall.
  3. Carefully slide the side panels within the arms into position on the frame assembly.
  4. Carefully slide the top panel within the arms into position on the frame assembly.
  5. Using 4 x hexagonal headed bolts provided, secure the front panel to the guard assembly

NB The extra panel and floor mounted fixing feet provided will not be needed for this type of installation.

HIGH WALL MOUNTED UNITS

For high wall mounted unit installations slide the extra panel into position at the bottom of the cage assembly prior to fitting the front panel as detailed within instruction 5 above.

NB The floor mounted fixing feet provided will not be needed for this type of installation.