OVERVIEW

makita-DHR400ZKU-Cordless-Rotary-Hammer-fig-1

SPECIFICATIONS

  • Due to our continuing program of research and development, the specifications herein are subject to change without notice.
  • Specifications and battery cartridge may differ from country to country.
  • The weight may differ depending on the attachment(s), including the battery cartridge. The lightest and heaviest combination, according to EPTA-Procedure 01/2014, are shown in the table.

Applicable battery cartridge
BL1815N / BL1820 / BL1820B / BL1830 / BL1830B / BL1840 / BL1840B / BL1850 / BL1850B / BL1860B

  • Some of the battery cartridges listed above may not be available depending on your region of residence.

WARNING: Only use the battery cartridges listed above. Use of any other battery cartridges may cause injury and/or fire.

Intended use

The typical A-weighted noise level determined accord- ing to EN60745:

  • Sound pressure level (LpA) : 91 dB(A)
  • Sound power level (LWA) : 102 dB (A)
  • Uncertainty (K) : 3 dB(A)

WARNING: Wear ear protection.

Vibration

  • The vibration total value (tri-axial vector sum) deter- mined according to EN60745:
  • Work mode: hammer drilling into concrete Vibration emission (ah, HD): 5.0 m/s2
  • Uncertainty (K) : 1.5 m/s2
  • Work mode: chiselling function with side grip Vibration emission (ah, Cheq): 4.5 m/s2
  • Uncertainty (K) : 1.5 m/s2
  • Work mode: chiselling function with side handle Vibration emission (ah, Cheq): 4.5 m/s2
  • Uncertainty (K) : 1.5 m/s2

NOTE: The declared vibration emission value has been measured in accordance with the standard test method and may be used for comparing one tool with another.
NOTE: The declared vibration emission value may also be used in a preliminary assessment of exposure.

WARNING: The vibration emission during actual use of the power tool can differ from the declared emission value depending on the ways in which the tool is used.

WARNING: Be sure to identify safety measures to protect the operator that are based on an estimation of exposure in the actual conditions of use (taking account of all parts of the operating cycle such as the times when the tool is switched off and when it is running idle in addition to the trigger time).

EC Declaration of Conformity

For European countries only
The EC declaration of conformity is included as Annex A to this instruction manual.

SAFETY WARNINGS

General power tool safety warnings

WARNING: Read all safety warnings, instruc-tions, illustrations and specifications provided with this power tool. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future reference.
The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.

CORDLESS ROTARY HAMMER SAFETY WARNINGS

  1. Wear ear protectors. Exposure to noise can cause hearing loss.
  2. Use auxiliary handle(s), if supplied with the tool. Loss of control can cause personal injury.
  3. Hold power tool by insulated gripping sur-faces, when performing an operation where the cutting accessory may contact hidden wiring. Cutting accessory contacting a “live” wire may make exposed metal parts of the power tool “live” and could give the operator an electric shock.
  4. Wear a hard hat (safety helmet), safety glasses and/or face shield. Ordinary eye or sun glasses are NOT safety glasses. It is also highly recom-mended that you wear a dust mask and thickly padded gloves.
  5. Be sure the bit is secured in place before operation.
  6. Under normal operation, the tool is designed to produce vibration. The screws can come loose easily, causing a breakdown or accident. Check tightness of screws carefully before operation.
  7. In cold weather or when the tool has not been used for a long time, let the tool warm up for a while by operating it under no load. This will loosen up the lubrication. Without proper warm-up, hammering operation is difficult.
  8. lways be sure you have a firm footing. Be sure no one is below when using the tool in high locations.
  9. Hold the tool firmly with both hands.
  10. Keep hands away from moving parts.
  11. Do not leave the tool running. Operate the tool only when hand-held.
  12. Do not point the tool at any one in the area when operating. The bit could fly out and injure someone seriously.
  13. Do not touch the bit, parts close to the bit, or workpiece immediately after operation; they may be extremely hot and could burn your skin.
  14. Some material contains chemicals which may be toxic. Take caution to prevent dust inhala-tion and skin contact. Follow material supplier safety data.
  15. Always be sure that the tool is switched off and the battery cartridge and the bit are removed before handing the tool to other person.

SAVE THESE INSTRUCTIONS.

WARNING: DO NOT let comfort or familiarity with product (gained from repeated use) replace strict adherence to safety rules for the subject product. MISUSE or failure to follow the safety rules stated in this instruction manual may cause serious personal injury.

Important safety instructions for battery cartridge

  1. Before using battery cartridge, read all instruc-tions and cautionary markings on (1) battery charger, (2) battery, and (3) product using battery.
  2. Do not disassemble battery cartridge.
  3. If operating time has become excessively shorter, stop operating immediately. It may result in a risk of overheating, possible burns and even an explosion.
  4. If electrolyte gets into your eyes, rinse them out with clear water and seek medical atten-tion right away. It may result in loss of your eyesight.
  5. Do not short the battery cartridge:
  6. Do not touch the terminals with any con-ductive material.
  7. Avoid storing battery cartridge in a con-tainer with other metal objects such as nails, coins, etc.
  8. Do not expose battery cartridge to water or rain. A battery short can cause a large current flow, overheating, possible burns and even a breakdown.
  9. Do not store the tool and battery cartridge in locations where the temperature may reach or exceed 50 °C (122 °F).
  10. Do not incinerate the battery cartridge even if it is severely damaged or is completely worn out. The battery cartridge can explode in a fire.
  11. Be careful not to drop or strike battery.
  12. Do not use a damaged battery.
  13. The contained lithium-ion batteries are subject to the Dangerous Goods Legislation require-ments. For commercial transports e.g. by third parties, forwarding agents, special requirement on pack-aging and labeling must be observed. For preparation of the item being shipped, consult-ing an expert for hazardous material is required. Please also observe possibly more detailed national regulations. Tape or mask off open contacts and pack up the battery in such a manner that it cannot move around in the packaging.
  14. Follow your local regulations relating to dis-posal of battery.
  15. Use the batteries only with the products specified by Makita. Installing the batteries to non-compliant products may result in a fire, exces-sive heat, explosion, or leak of electrolyte.

SAVE THESE INSTRUCTIONS.

CAUTION: Only use genuine Makita batteries. Use of non-genuine Makita batteries, or batteries that have been altered, may result in the battery bursting causing fires, personal injury and damage. It will also void the Makita warranty for the Makita tool and charger.

Tips for maintaining maximum battery life

  1. Charge the battery cartridge before completely discharged. Always stop tool operation and charge the battery cartridge when you notice less tool power.
  2. Never recharge a fully charged battery cartridge. Overcharging shortens the battery service life.
  3. Charge the battery cartridge with room tempera-ture at 10 °C – 40 °C (50 °F – 104 °F). Let a hot battery cartridge cool down before charging it.
  4. Charge the battery cartridge if you do not use it for a long period (more than six months).

Important safety instructions for wireless unit

  1. Do not disassemble or tamper with the wire-less unit.
  2. Keep the wireless unit away from young chil-dren. If accidentally swallowed, seek medical attention immediately.
  3. Use the wireless unit only with Makita tools.
  4. Do not expose the wireless unit to rain or wet conditions.
  5. Do not use the wireless unit in places where the temperature exceeds 50°C (122°F).
  6. Do not operate the wireless unit in places where medical instruments, such as heart pacemakers are nearby.
  7. Do not operate the wireless unit in places where automated devices are near by. If operated, automated devices may develop malfunction or error.
  8. The wireless unit can produce electromagnetic fields (EMF) but they are not harmful to the user.
  9. The wireless unit is an accurate instrument. Be careful not to drop or strike the wireless unit.
  10. Avoid touching the terminal of the wireless unit with bare hands or metallic materials.
  11. Always remove the battery on the tool when installing the wireless unit.
  12. When opening the lid of the slot, avoid the place where dust and water may come into the slot. Always keep the inlet of the slot clean.
  13. Always insert the wireless unit in the correct direction.
  14. Do not press the wireless activation button on the wireless unit too hard and/or press the button with an object with a sharp edge.
  15. Always close the lid of the slot when operating.
  16. Do not remove the wireless unit from the slot while the power is being supplied to the tool. Doing so may cause a malfunction of the wireless unit.
  17. Do not remove the sticker on the wireless unit.
  18. Do not put any sticker on the wireless unit.
  19. Do not leave the wireless unit in a place where static electricity or electrical noise could be generated.
  20. Do not leave the wireless unit in a place subject to high heat, such as a car sitting in the sun.
  21. Do not leave the wireless unit in a dusty or powdery place or in a place corrosive gas could be generated.
  22. Sudden change of the temperature may bedew the wireless unit. Do not use the wireless unit until the dew is completely dried.
  23. When cleaning the wireless unit, gently wipe with a dry soft cloth. Do not use benzine, thin-ner, conductive grease or the like.
  24. When storing the wireless unit, keep it in the supplied case or a static-free container.
  25. Do not insert any devices other than Makita wireless unit into the slot on the tool.
  26. Do not use the tool with the lid of the slot dam-aged. Water, dust, and dirt come into the slot may cause malfunction.
  27. Do not pull and/or twist the lid of the slot more than necessary. Restore the lid if it comes off from the tool.
  28. Replace the lid of the slot if it is lost or damaged.

FUNCTIONAL DESCRIPTION

CAUTION: Always be sure that the tool is switched off and the battery cartridge is removed before adjusting or checking function on the tool.

Installing or removing battery cartridge

  • CAUTION: Always switch off the tool before installing or removing of the battery cartridge.
  • CAUTION: Hold the tool and the battery car-tridge firmly when installing or removing battery cartridge. Failure to hold the tool and the battery cartridge firmly may cause them to slip off your hands and result in damage to the tool and battery cartridge and a personal injury.

Fig.1: 1. Red indicator 2. Button 3. Battery cartridge To remove the battery cartridge, slide it from the tool while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the battery cartridge with the groove in the housing and slip it into place. Insert it all the way until it locks in place with a little click. If you can see the red indicator on the upper side of the button, it is not locked completely.

  • CAUTION: Always install the battery cartridge fully until the red indicator cannot be seen. If not, it may accidentally fall out of the tool, causing injury to you or someone around you.
  • CAUTION: Do not install the battery cartridge forcibly. If the cartridge does not slide in easily, it is not being inserted correctly.

Indicating the remaining battery capacity

Only for battery cartridges with the indicator

Fig.2: 1. Indicator lamps 2. Check button Press the check button on the battery cartridge to indicate the remaining battery capacity. The indicator lamps light up for a few seconds.makita-DHR400ZKU-Cordless-Rotary-Hammer-
fig-31

NOTE: Depending on the conditions of use and the ambient temperature, the indication may differ slightly from the actual capacity.

Tool / battery protection system

The tool is equipped with a tool/battery protection sys-tem. This system automatically cuts off power to the motor to extend tool and battery life. The tool will auto-matically stop during operation if the tool or battery is placed under one of the following conditions:

Overload protection
When the battery is operated in a manner that causes it to draw an abnormally high current, the tool automat-ically stops without any indication. In this situation, turn the tool off and stop the application that caused the tool to become overloaded. Then turn the tool on to restart.

Overheat protection
When the tool or battery is overheated, the tool stops automatically and the lamp blinks. In this case, let the tool and battery cool before turning the tool on again.

Overdischarge protection
When the battery capacity is not enough, the tool stops automatically. In this case, remove the battery from the tool and charge the battery.

Switch action

WARNING: Before installing the battery car-tridge into the tool, always check to see that the switch trigger actuates properly and returns to the “OFF” position when released.

CAUTION: When not operating the tool, depress the trigger-lock button lock from side to lock the switch trigger in the OFF position.
► Fig.3: 1. Switch trigger 2. Trigger-lock buttonmakita-DHR400ZKU-Cordless-
Rotary-Hammer-fig-4

To prevent the switch trigger from accidentally pulled, the trigger-lock button is provided. To start the tool, depress the trigger-lock button from A side and pull the switch trigger. Release the switch trigger to stop. After use, press in the trigger-lock button from B side.

Speed change

The revolutions and blows per minute can be adjusted by turning the adjusting dial. The dial is marked 1 (lowest speed) to 5 (full speed). ► Fig.4: 1. Adjusting dial Refer to the table below for the relationship between the number on the adjusting dial and the revolutions and blows per minute.

Number| Revolutions per minute| Blows per minute
---|---|---
5| 500| 2,900
4| 470| 2,700
3| 380| 2,150
2| 290| 1,650
1| 250| 1,450

  • CAUTION: Do not turn the adjusting dial when the tool is running. Failure to do so may result in the loss of control of the tool and cause an injury.
  • NOTICE: If the tool is operated continuously at low speed for a long time, the motor will get over-loaded, resulting in tool malfunction.
  • NOTICE: The speed adjusting dial can be turned only as far as 5 and back to 1. Do not force it past 5 or 1, or the speed adjusting function may no longer work.
  • NOTE: When the speed adjusting dial is set to “3” or higher, the tool automatically reduces the speed at
    no-load to reduce the vibration under no-load. Once operation starts with a bit against concrete, blows per minute increase and reach the numbers as shown in the table. When temperature is low and there is less fluidity in grease, the tool may not have this function even with the motor rotating.

Lighting up the front lamp

Fig.5: 1. Lamp

  • CAUTION: Do not look in the light or see the source of light directly. Pull the switch trigger to light up the lamp. The lamp keeps on lighting while the switch trigger is being pulled. The lamp goes out approximately 10 seconds after releasing the switch trigger.
  • NOTE: Use a dry cloth to wipe the dirt off the lens of the lamp. Be careful not to scratch the lens of lamp, or it may lower the illumination.

Selecting the action mode

  • NOTICE: Do not rotate the action mode chang-ing knob when the tool is running. The tool will be damaged.
  • NOTICE: To avoid rapid wear on the mode change mechanism, be sure that the action mode changing knob is always positively located in one of the three action mode positions.

Rotation with hammering
For drilling in concrete, masonry, etc., rotate the action  mode changing knob to the symbol. Use a carbide- tipped drill bit. ► Fig.6: 1. Action mode changing knob 2. Pointer

Hammering only
For chipping, scaling or demolition operations, rotate the action mode changing knob to the symbol. Use a bull point, cold chisel, scaling chisel, etc. ► Fig.7: 1. Pointer 2. Action mode changing knob

Torque limiter

NOTICE: As soon as the torque limiter actuates, switch off the tool immediately. This will help prevent premature wear of the tool.
NOTICE: Drill bits such as hole saw, which tend to pinch or catch easily in the hole, are not appropriate for this tool. This is because they will cause the torque limiter to actuate too frequently.

The torque limiter will actuate when a certain torque level is reached. The motor will disengage from the output shaft. When this happens, the drill bit will stop turning.

Constant speed control

Electronic speed control for obtaining constant speed. Possible to get fine finish, because the rotating speed is kept constant even under load condition.

ASSEMBLY

CAUTION: Always be sure that the tool is switched off and the battery cartridge is removed before carrying out any work on the tool.

Side handle

Fig.8

CAUTION: Use the side handle only when chipping, scaling or demolishing. Do not use it when drilling in concrete, masonry, etc. The tool cannot be held properly with this side handle when
drilling.

Fig.9: 1. Side handle 2. Clamp nut The side handle can be swung 360° on vertically and secured at any desired position. It also secures at eight different positions back and forth on the horizontal. Loosen the clamp nut to swing the side handle to a desired position, and then tighten the clamp nut securely.

Side grip (auxiliary handle)

  • CAUTION: Always use the side grip to ensure safe operation.
  • CAUTION: After installing or adjusting the side grip, make sure that the side grip is firmly secured.

The side grip swings around to either side, allowing easy handling of the tool in any position. Loosen the side grip by turning it counterclockwise, swing it to the desired position and then tighten it by turning clockwise.

Fig.10: 1. Side grip

Grease
Coat the shank end of the drill bit beforehand with a small amount of grease (about 0.5 – 1 g). This chuck lubrication assures smooth action and lon-ger service life.

Installing or removing drill bit

Clean the shank end of the drill bit and apply grease before installing the drill bit.

Fig.11: 1. Shank end 2. Grease Insert the drill bit into the tool. Turn the drill bit and push it in until it engages. After installing the drill bit, always make sure that the drill bit is securely held in place by trying to pull it out.

Fig.12: 1. Drill bit To remove the drill bit, pull the chuck cover down all the way and pull the drill bit out.

Fig.13: 1. Drill bit 2. Chuck covermakita-DHR400ZKU-Cordless-Rotary-Hammer-
fig-11

Chisel angle (when chipping, scaling or demolishing)

The chisel can be secured at the desired angle. To change the chisel angle, rotate the action mode changing the knob to the O symbol. Turn the chisel to the desired angle.

► Fig.14: 1. Action mode changing knob 2. Pointer Rotate the action mode changing knob to the symbol. Then make sure that the chisel is securely held in place by turning it slightly.makita-DHR400ZKU-Cordless-Rotary-Hammer-
fig-13

Depth gauge
The depth gauge is convenient for drilling holes of uniform depth. Press and hold the lock button, and then insert the depth gauge into the hex hole.
► Fig.15: 1. Depth gauge 2. Lock button Make sure that the toothed side of the depth gauge faces the marking.
► Fig.16: 1. Marking 2. Toothed side Adjust the depth gauge by moving it back and forth while pressing the lock button. After the adjustment, release the lock button to lock the depth gauge.makita-DHR400ZKU-Cordless-Rotary-Hammer-
fig-15

NOTE: Make sure that the depth gauge does not touch the main body of the tool when attaching it.

Dust extractor attachment

Optional accessory

Installing the dust extractor attachment

  1. Loosen the side grip on the tool.

  2. Install the dust cover so that the claws of the dust cover fit in the grooves between the tool and the side grip.
    ► Fig.17: 1. Dust cover 2. Claw 3. Groove

  3. Tighten the side grip securely.

  4. Set the suitable bellows or dust cover extension for your work. When you use bellows, attach the joint to its top. When you stack two bellows, connect them with the joint.
    ► Fig.18: 1. Dust cover extension 2. Dust cover 3. Joint 4. Bellows

Connecting the tool to the vacuum cleaner

  1. Attach the holder joint to the tool, and then attach the hose holder to the holder’s joint. ► Fig.19: 1. Holder joint 2. Hose holder
  2. Fix the hose to the hose holder. ► Fig.20: 1. Hose holdermakita-DHR400ZKU-Cordless-Rotary-Hammer-fig-18

NOTE: Use joint 25 to connect the hose and the dust cover if necessary.

Using depth gauge for drilling operation
When you stack two bellows, attach the depth gauge extension to the depth gauge. ► Fig.21: 1. Depth gauge extension

Dust extractor attachment (for hammering only)

Optional accessorymakita-DHR400ZKU-Cordless-Rotary-Hammer-
fig-19 makita-DHR400ZKU-Cordless-Rotary-Hammer-
fig-21

  1. Install the hose holder.
    When the side handle is installed to tool, loosen the clamp nut, and then remove the hex bolt. Install the hose holder with the hex bolt and the clamp nut by tightening the clamp nut firmly.
    ► Fig.22: 1. Bolt 2. Hose holder 3. Clamp nut When the side grip is installed to the tool, loosen the side grip, mount the hose holder to the shaft, and then tighten the side grip firmly.
    ► Fig.23: 1. Hose holder 2. Shaft 3. Side grip

  2. Attach the holder joint to the tool, and then attach the hose holder to the holder joint.
    ► Fig.24: 1. Holder joint 2. Hose holder

  3. Attach the dust cover and the hose to the tool, and then fix the hose to the hose holders.
    ► Fig.25: 1. Dust cover 2. Hose 3. Hose holder

  4. Connect the hose to the hose of the vacuum cleaner with the hose joint.
    NOTE: If the hose is not included, attach the dust cover to the cleaner’s joint or attach it to Makita’s hose ø28.

  5. Adjust the distance between the dust cover and the tip of the chisel or bull point. The recommended distance is 30 mm to 100 mm.
    ► Fig.26: (1) 30 mm to 100 mm

OPERATION

  • CAUTION: Always use the side grip (auxiliary handle) and firmly hold the tool by both side grip and switch handle during operations.
  • CAUTION: Always make sure that the workpiece is secured before operation.
  • CAUTION: Do not pull the tool out forcibly even the bit gets stuck. Loss of control may cause injury.
  • NOTE: If the battery cartridge is in low temperature, the tool’s capability may not be fully obtained. In this case, warm up the battery cartridge by using the tool with no load for a while to fully obtain the tool’s capability. ► Fig.27makita-DHR400ZKU-Cordless-Rotary-Hammer-fig-22

Hammer drilling operation

CAUTION: There is tremendous and sudden twisting force exerted on the tool/drill bit at the time of hole break-through, when the hole becomes cloggedwith chips and particles, or when striking reinforcing rods embedded in the concrete. Always use the side grip (auxiliary handle) and firmly hold the tool by both side grip and switch handle during opera- tions. Failure to do so may result in the loss of control of the tool and potentially severe injury. Set the action mode changing knob to the symbol. Position the drill bit at the desired location for the hole, then pull the switch trigger. Do not force the tool. Light pressure gives best results. Keep the tool in position and prevent it from slipping away from the hole. Do not apply more pressure when the hole becomes clogged with chips or particles. Instead, run the tool at an idle, then remove the drill bit partially from the hole. By repeating this several times, the hole will be cleaned out and normal drilling may be resumed.

NOTE: Eccentricity in the drill bit rotation may occur while operating the tool with no load. The tool auto-matically centers itself during operation. This does not affect the drilling precision.

Chipping/Scaling/Demolition

Set the action mode changing knob to the symbol. Hold the tool firmly with both hands. Turn the tool on and apply slight pressure on the tool so that the tool will not bounce around, uncontrolled. Pressing very hard on the tool will not increase the efficiency. Fig.28

Blow-out bulb

makita-DHR400ZKU-Cordless-Rotary-Hammer-fig-23

Optional accessory
After drilling the hole, use the blow-out bulb to clean the dust out of the hole. Fig.29

WIRELESS ACTIVATION FUNCTION

Optional accessory

What you can do with the wireless activation function

The wireless activation function enables clean and com-fortable operation. By connecting a supported vacuum cleaner to the tool, you can run the vacuum cleaner automatically along with the switch operation of the tool. Fig.30

To use the wireless activation function, prepare following

items:

  • A wireless unit (optional accessory)
  • A vacuum cleaner which supports the wireless activation function

The overview of the wireless activation function setting is as follows. Refer to each section for detail procedures.

  1. Installing the wireless unit
  2. Tool registration for the vacuum cleaner
  3. Starting the wireless activation function

Installing the wireless unit

Optional accessory
  • CAUTION: Place the tool on a flat and stable surface when installing the wireless unit.
  • NOTICE: Clean the dust and dirt on the tool before installing the wireless unit. Dust or dirt may cause malfunction if it comes into the slot of the wireless unit.
  • NOTICE: To prevent the malfunction caused by static, touch a static discharging material, such as a metal part of the tool, before picking up the wireless unit.
  • NOTICE: When installing the wireless unit,  always be sure that the wireless unit is inserted in the correct direction and the lid is completely closed.makita-DHR400ZKU-Cordless-Rotary-Hammer-fig-24
  1. Open the lid on the tool as shown in the figure. ► Fig.31: 1. Lid
  2. Insert the wireless unit to the slot and then close the lid. When inserting the wireless unit, align the projections with the recessed portions on the slot. ► Fig.32: 1. Wireless unit 2. Projection 3. Lid
  3. Recessed portion When removing the wireless unit, open the lid slowly. The hooks on the back of the lid will lift the wireless unit as you pull up the lid. ► Fig.33: 1. Wireless unit 2. Hook 3. Lid After removing the wireless unit, keep it in the supplied case or a static-free container.makita-DHR400ZKU-Cordless-Rotary-Hammer-fig-25
    NOTICE: Always use the hooks on the back of the lid when removing the wireless unit. If the hooks do not catch the wireless unit, close the lid completely and open it slowly again.

Starting the wireless activation function

  • NOTE: Finish the tool registration for the vacuum cleaner prior to the wireless activation.
  • NOTE: Refer to the instruction manual of the vacuum cleaner, too. After registering a tool to the vacuum cleaner, the vacuum cleaner will automatically runs along with the switch operation of the tool.
  1. Install the wireless unit to the tool.

  2. Connect the hose of the vacuum cleaner with the tool.
    ► Fig.36

  3. Set the stand-by switch on the vacuum cleaner to “AUTO”.
    ► Fig.37: 1. Stand-by switch

  4. Push the wireless activation button on the tool briefly. The wireless activation lamp will blink in blue.
    ► Fig.38: 1. Wireless activation button 2. Wireless activation lamp

  5. Pull the switch trigger of the tool. Check if the vacuum cleaner runs while the switch trigger is being pulled. To stop the wireless activation of the vacuum cleaner, push the wireless activation button on the tool.makita-DHR400ZKU-Cordless-Rotary-Hammer-fig-27 makita-DHR400ZKU-Cordless-Rotary-Hammer-fig-28

  • NOTE: The wireless activation lamp on the tool will stop blinking in blue when there is no operation for 2 hours. In this case, set the stand-by switch on the vacuum cleaner to “AUTO” and push the wireless activation button on the tool again.
  • NOTE: The vacuum cleaner starts/stops with a delay. There is a time lag when the vacuum cleaner detects a switch operation of the tool.
  • NOTE: The transmission distance of the wireless unit may vary depending on the location and surrounding circumstances.
  • NOTE: When two or more tools are registered to one vacuum cleaner, the vacuum cleaner may start running even if you don’t pull the switch trigger because an other user is using the wireless activation function.

Description of the wireless activation lamp status

makita-DHR400ZKU-Cordless-Rotary-Hammer-fig-32
► Fig.39: 1. Wireless activation lamp The wireless activation lamp shows the status of the wireless activation function. Refer to the table below for the meaning of the lamp status.

Cancelling tool registration for the vacuum cleaner
Perform the following procedure when cancelling the tool registration for the vacuum cleaner.

  1. Install the batteries to the vacuum cleaner and the tool.
  2. Set the stand-by switch on the vacuum cleaner to “AUTO”. ► Fig.40: 1. Stand-by switch
  3. Press the wireless activation button on the vacuum cleaner for 6 seconds. The wireless activation lamp blinks in green and then become red. After that, press the wireless activation button on thetool in the same way. ► Fig.41: 1. Wireless activation button 2. Wireless activation lamp If the cancellation is performed successfully, the wireless activation lamps will light up in red for 2 seconds and start blinking in blue.

NOTE: The wireless activation lamps finish blinking in red after 20 seconds elapsed. Press the wireless activation button on the tool while the wireless activation lamp on the cleaner is blinking. If the wireless activation lamp does not blink in red, push the wireless activation button briefly and hold it down again.

Troubleshooting for wireless activation function

Before asking for repairs, conduct your own inspection first. If you find a problem that is not explained in the manual, do not attempt to dismantle the tool. Instead, ask Makita Authorized Service Centers, always using Makita replacement parts for repairs.

State of abnormality| Probable cause (malfunction)| Remedy
---|---|---
The wireless activation lamp does not light/blink.| The wireless unit is not installed into

the tool.

The wireless unit is improperly installed

into the tool.

| Install the wireless unit correctly.
The terminal of the wireless unit and/or the slot is dirty.| Gently wipe off dust and dirt on the terminal of the

wireless unit and clean the slot.

The wireless activation button on the

tool has not been pushed.

| Push the wireless activation button on the tool

briefly.

The stand-by switch on the vacuum cleaner is not set to “AUTO”.| Set the stand-by switch on the vacuum cleaner to “AUTO”.
No power supply| Supply the power to the tool and the vacuum

cleaner.

Cannot finish tool registration / can- celling tool registration successfully.| The wireless unit is not installed into

the tool.

The wireless unit is improperly installed

into the tool.

| Install the wireless unit correctly.
The terminal of the wireless unit and/or the slot is dirty.| Gently wipe off dust and dirt on the terminal of the

wireless unit and clean the slot.

The stand-by switch on the vacuum cleaner is not set to “AUTO”.| Set the stand-by switch on the vacuum cleaner to “AUTO”.
No power supply| Supply the power to the tool and the vacuum

cleaner.

Incorrect operation| Push the wireless activation button briefly and perform the tool registration/cancellation procedures again.
The tool and vacuum cleaner is away from each other (out of the transmission range).| Get the tool and vacuum cleaner closer to each other. The maximum transmission distance is approximately 10 m however it may vary according to the circumstances.
Before finishing the tool registration/

cancellation;

– the switch trigger on the tool is pulled or;

– the power button on the vacuum cleaner is turned on.

| Push the wireless activation button briefly and perform the tool registration/cancellation procedures again.
The tool registration procedures for the tool or vacuum cleaner has not finished.| Perform the tool registration procedures for both the

tool and the vacuum cleaner at the same timing.

Radio disturbance by other appliances which generate high-intensity radio waves.| Keep the tool and vacuum cleaner away from the appliances such as Wi- Fi devices and microwave ovens.
State of abnormality| Probable cause (malfunction)| Remedy
---|---|---
The vacuum cleaner does not run along with the switch operation of the tool.| The wireless unit is not installed into

the tool.

The wireless unit is improperly installed

into the tool.

| Install the wireless unit correctly.
The terminal of the wireless unit and/or the slot is dirty.| Gently wipe off dust and dirt on the terminal of the

wireless unit and clean the slot.

The wireless activation button on the

tool has not been pushed.

| Push the wireless activation button briefly and make

sure that the wireless activation lamp is blinking in blue.

The stand-by switch on the vacuum cleaner is not set to “AUTO”.| Set the stand-by switch on the vacuum cleaner to “AUTO”.
More than 10 tools are registered to the vacuum cleaner.| Perform the tool registration again.

If more than 10 tools are registered to the vacuum cleaner, the tool registered earliest will be cancelled automatically.

The vacuum cleaner erased all tool

registrations.

| Perform the tool registration again.
No power supply| Supply the power to the tool and the vacuum

cleaner.

The tool and vacuum cleaner is away from each other (out of the transmission range).| Get the tool and vacuum cleaner closer each other. The maximum transmission distance is approxi- mately 10 m however it may vary according to the circumstances.
Radio disturbance by other appliances which generate high-intensity radio waves.| Keep the tool and vacuum cleaner away from the appliances such as Wi- Fi devices and microwave ovens.
The vacuum cleaner runs while the

tool’s switch trigger is not pulled.

| Other users are using the wireless activation of the vacuum cleaner with their tools.| Turn off the wireless activation button of the other tools or cancel the tool registration of the other tools.

MAINTENANCE

CAUTION: Always be sure that the tool is switched off and the battery cartridge is removed before attempting to perform inspection or maintenance.
NOTICE: Never use gasoline, benzine, thinner, alcohol or the like. Discoloration, deformation or cracks may result.

To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or adjustment should be performed by Makita Authorized or Factory Service Centers, always using Makita replacement parts.

OPTIONAL ACCESSORIES

CAUTION: These accessories or attachments are recommended for use with your Makita toolspecified in this manual. The use of any other accessories or attachments might present a risk of injury to persons. Only use accessory or attachment for its stated purpose. If you need any assistance for more details regarding these accessories, ask your local Makita Service Center.

  • SDS-MAX Carbide-tipped drill bits
  • SDS-MAX bull point
  • SDS-MAX cold chisel
  • SDS-MAX scaling chisel
  • SDS-MAX clay spade
  • Hammer grease
  • Bit grease
  • Side handle
  • Side grip
  • Depth gauge
  • Blow-out bulb
  • Dust extractor attachment
  • Safety goggles
  • Wireless unit
  • Makita genuine battery and charger
  • Plastic carrying case

NOTE: Some items in the list may be included in the tool package as standard accessories. They may differ from country to country.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals