WISUALARM M1 CO2 Air Quality Monitor User Manual

June 9, 2024
WISUALARM

WISUALARM M1 CO2 Air Quality Monitor

WISUALARM-M1-CO2-Air-Quality-Monitor-PRODUCT

Please read this manual carefully before using the product and keep it properly.

What is carbon dioxide (CO,)

Carbon dioxide (CO) is a colorless, odorless gas that is produced by metabolic processes, combustion processes, and motor cars operating in garages. People and other animals exhale carbon dioxide when they breathe. Although carbon dioxide alone is not dangerous, the quantity found inside is utilized as a gauge for human comfort. The majority of the time, CO2 poses a health risk when its concentration is high enough to displace oxygen and cause suffocating in small spaces.

What are the effect of exposure under high-level carbon dioxide?

In buildings with increased CO OCcupants may have health problems. The carbon dioxide itself can produce headaches, lightheadedness, nausea, and other symptoms at high concentrations. This could happen after many hours of exposure to levels higher than 5,000 ppm. Exposure to CO, concentrations about 40,000 ppm is instantly hazardous to life and health since it can asphyxiate at much greater levels by replacing oxygen in the blood.

WISUALARM-M1-CO2-Air-Quality-Monitor-FIG-4 WISUALARM-M1-CO2-Air-Quality-Monitor-FIG-5

What should I do if the Air Quality Monitor goes off?

When the carbon dioxide concentration reaches a high level, the product will emit an audible signal and red LED goes on. For your safety, please ventilate your rooms:

  • Open doors and windows
  • Turn on mechanical ventilation system such as HVAC system

Product Introduction

WISUALARM-M1-CO2-Air-Quality-Monitor-FIG-1

  1. The product can monitor indoor temperature, humidity, and CO, concentration to easily master indoor air quality.
  2. The 4.2-inch extra-large E-ink screen is used as the display screen, which can provide a paper-like display texture and a clear multi-view angle.

Attention: Please avoid blocking the vent hole when using the monitor.

Accessories

WISUALARM-M1-CO2-Air-Quality-Monitor-FIG-2

Note: The illustrations of products, accessories, user interface, etc. in the manual are schematic diagrams for reference only. Due to product updates and upgrades, the actual products may be slightly different from the schematic diagrams. Please refer to the actual products.

Screen Display

WISUALARM-M1-CO2-Air-Quality-Monitor-FIG-3

How to use

Before use

Please charge the monitor before the first use. At the same time, turn on the monitor and vetilate for more than 24 hours. There is no need to operate the monitor during ventilation. Remove the pollutants (if any) on the sensor from the package or the interfering gases. Meanwhile, the product will be self- calibrated to ensure the accuracy of subsequent measurements. When testing, please place the product upright on the object platform where testing is performed, such as the desk or workbench. Please avoid holding the tester or blocking the vent hole.

Daily monitoring

  1. Turn on the monitor
    • Press the power button for 3 seconds to turn on the monitor.
  2. Start monitoring
    • After warming up for 5 minutes, the monitor enters the monitoring mode, and the screen displays the CO; value detected in real time. At this time, user could take the monitor on the place to be monitored for about 5 minutes, then read the current value through the screen.
  3. Turn off the monitor
    • In the monitoring mode, press the power button for 3 seconds to turn off the monitor.
  4. Charging
    • This product uses a lithium battery for power supply. When the low battery symbol °is displayed on the screen, it indicates that the monitor has low power and needs to be charged. Please insert the charging cable’s USB Type-C connector into the charging port on the back of the monitor and USB Type-A connector into the power adapter for charging. The product can be fully charged about 6 hours after being connected to the power supply.
    • Note: Please use a 5V USB power supply for charging and ensure that the output current is greater than 1A. If the monitor is not used for a long time, please charge it regularly. It is recommended to charge it at least every 3 months.
  5. Restore default settings
    • Long press the power button (hold for at least 16 seconds) until the monitor refresh screen, then restart the monitor to restore the default settings.

Power Button Function & Indication Light Status Introduction

be fully charged about 6 hours after being connected to the power supply.
Note: Please use a 5V USB power supply for charging and ensure that the output
current is greater than 1A. If the monitor is not used for a long time, please
charge it regularly. It is recommended to charge it at least every 3 months.
5. Restore default settings Long press the power button \(hold for at least 16
seconds\) until the monitor refresh the screen, then restart the monitor to
restore the default settings. Power Button Function & Indication Light Status
Introduction

_ Note: _When the buzzer alarm occurs, you can click the button to turn off the buzzer.

Emoji Introduction

WISUALARM-M1-CO2-Air-Quality-Monitor-FIG-7

Technical Parameters

  • Product Model: DH-HY-M1
  • Power Input: DC 5V 1A
  • Battery Model: 2500mAh rechargeable lithium battery
  • Product Material: PC/ABS
  • Net Weight: 148g
  • Product Size: 108 91×43.7mm
  • CO Measurement Range: 400-5000 ppm
  • Temperature Measurement Range: 0’C- 60’C
  • Humidity Measurement Range: 0% – 99%RH
  • Temperature Units: “C/F
  • Operating Temperature and Humidity Range: 0’C- 50 C, 10%- 90%RH
  • Operating Atmospheric Pressure Range: 70kPa-106kPa
  • Transportation and Storage Requirements of Temperature and Humidity: -20 C- 60 C, 10% – 95%RH
  • Transportation and Storage Requirements of Atmospheric Pressure: 50kPa-106kPa

Attention

  • Do not block the vent hole.
  • Try to avoid long-term use of the monitor at high temperatures and humidity environment.
  • Do not face the monitor directly to the household ventilation appliance, or it will cause measurement deviation.
  • If the charging cable is damaged, it shall be replaced with a special cable or a special component purchased from its manufacturer or maintenance department
  • Lithium battery is dangerous. User shall not attempt to remove the battery. Forcibly removing or replacing the battery may cause an explosion.
  • The battery may also cause explosion if it is thrown into the fire.
  • Keep the battery and monitor dry, and away from water or other liquids to avoid short circuits.
  • Do not use the battery if it is damaged, deformed, discolored, Overheated or smells unpleasant.
  • Dispose of the wasted battery according to the manufacturer’s instructions.

Trouble Shooting

Unable to turn on the monitor on the first use. Please charge the monitor for a couple of minutes then turn on it. Please use an adapter with a voltage of 5V and an output current of more than 1A for charging.

All products bearing this symbol are waste electrical and electronic equipment (WEEE as in directive 2012/19/EU) which should not be mixed with unsorted household waste. Instead, you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment, appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. Please contact the installer or local authorities for more information about the location as well as terms and conditions of such collection points.

WISUALARM TECHNOLOGY

For more information, please visit www.wisualarm.com/en

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>