Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
FLEX VANE IMPELLER PUMP
CAUTION DO NOT pump flammable liquids. Do not pump in flammable or explosive environments.
Mounting
The pump can be positioned up to 7.5 feet (2.3 meters)
above the tank liquid level. Consider a location that allows easy access if
maintenance is required. The pump should not be located in an area less than
one cubic foot unless adequate ventilation is provided.
CAUTION Excessive heat may trigger the integral thermal breaker and
interrupt operation. When the motor temperature drops, the thermal breaker may
restart the pump without warning.
CAUTION To prevent electrical shock, protect pump from rain or washdown.
Flex vane pumps are not waterproof.
The pump may be mounted in any position. If mounting the pump vertically, the
pump head should be in the down position so that in the unlikely event of a
leak, water will
not enter the motor.
Use# 8 hardware to fasten the pump. The mounting feet are intended to isolate
the pump from the mounting surface; overtightening will reduce the ability to
isolate vibration and noise.
Electrical
The pump should be on a dedicated circuit. Use correct fuse and wire size as
specified in the following table.
Increase wire size to 12 AWG on 3000-050 if wire length exceeds 20 feet.
VOLTAGE STOCK# FUSE WIRE LEADS WIRE SIZE
12VDC| 3000-050| 15Amp| Red (+ pos)| 14 AWG
12VDC| 3000-350| n/a| Black (- neg)| 1.6 mm Dia.
115VAC| 3000-100| n/a| 3 prong plug with ground|
For 3000-050, an “on/off” switch rated at or above 15amps is recommended. The
switch must interrupt current flow on the (+ red) positive lead. Marine
applicationsshould use U/L approved marine duty (ignition protected)switches
and wiring standards.
On 12 VDC models 3000-050 and -350, the black (-) negative lead should be the
same gauge as the red (+) positivelead, and be connected to a known ground.
3000-100must be connected to a properly grounded three-prong115 VAC
receptacle.
Plumbing
SHURflo recommends 1/2” (13mm) I.D. flexible high pressure tubing to both
ports. Pump ports should not be connected to rigid pipe. Rigid pipe may crack
ports or transmit excessive noise.
Make sure washer in inlet fitting is clean and in good condition. Vacuum leaks
on the inlet side will cause a “no prime” condition.
Installation of 2522-3300 50 mesh in-line strainer on the inlet side is
recommended to prevent foreign debris from entering the pump. Failure due to
debris is not covered under the SHURflo limited warranty.
Operation
NOTE DO NOT run pump dry. Pump requires liquid for lubrication. If pump
does not prime within 20 seconds, recheck installation and plumbing. Failure
due to dry running is not covered under the SHURflo limited warranty. To help
priming, pour one ounce (30 ml) of liquid in inlet port.
Pump should prime within 20 seconds. If not, turn off the pump and do the
following:
Disconnect inlet hose at pump.
Pour one ounce (30 ml) of liquid into inlet port.
Check washers in inlet hose and make sure inlet is airtight.
Make sure inlet and discharge lines are free of kinks and restrictions.
Make sure pump is less than 7.5 ft (2.3 m) above the liquid source.
On older pumps that do not prime, replace the impeller with SHURflo P/N
94-120-00 impeller/seal kit.
Pump will deliver approximately 3.8 gallons (14 liters) per minute when
discharge is not restricted. As discharge is restricted, pressure increases,
and flow decreases. To prevent motor over heating, do not operate pump at a
discharge pressure of more than 12 psi (.8 bar) or discharge lift of more than
28 feet (8.5 meters). Motor is rated for intermittent duty only.
Winterizing
If water is allowed to freeze in the system, serious damage to the plumbing
and the pump may occur. The best guarantee against damage is to drain the
water system.
Failures of this type will void the warranty.
INDUSTRIAL PRODUCT LIMITED WARRANTY
SHURflo Industrial series pumps and products are warranted to be free of
defects in material and workmanship under normal use, for a period of one (1)
year from the date of manufacture, or one (1) year of use, with proof of
purchase. This limited warranty will not exceed two (2) years, in any event.
The limited warranty will not apply to pumps/products that were improperly
installed, misapplied, damaged, altered, incompatible with fluids or
components not manufactured by SHURflo.
All Industrial pumps/products must be flushed of any chemicals before
shipping. All warranty considerations are governed by SHURflo’s written Return
Policy.
Returns are to be shipped postage prepaid to either service center; SHURflo
Cypress, CA or Elkhart, IN. SHURflo shall not be liable for freight damage
incurred during shipping. Package returns carefully.
SHURflo’s obligation under this warranty policy is limited to the repair or
replacement of the pump/ product. All returns will be tested per SHURflo
factory criteria. Products found not defective (under the terms of this
limited warranty) are subject to charges paid by the returnee for the testing
and packaging of “tested good” non- warranty returns.
No credit or labor allowances will be given for pumps or products returned as
defective. Warranty replacements will be shipped on a freight allowed basis.
SHURflo reserves the right to choose the method of transportation.
This limited warranty is in lieu of all other warranties, expressed or
implied, and no other person is authorized to give any other warranty or
assume obligation or liability on SHURflo’s behalf. SHURflo shall not be
liable for any labor, damage or other expense, nor shall SHURflo be liable for
any indirect, incidental or consequential damages of any kind incurred by the
reason of the use or sale of any defective product or part. This limited
warranty covers industrial products distributed within the United States of
America. Other world market areas should consult with the actual distributor
for any deviation from this document.
RETURN POLICY
All Industrial pumps/products must be flushed of any chemical (ref. OSHA
Section 1910.1200 (d)(e)(f)(g)(h)) and hazardous chemicals must be labeled /
tagged before being shipped to SHURflo for service or warranty consideration.
SHURflo reserves the right to request a Material Safety Data Sheet from the
returnee for any pump/product it deems necessary. SHURflo reserves the right
to “disposition as scrap” pumps/products returned which contain unknown
fluids. SHURflo reserves the right to charge the returnee for any and all
costs incurred for chemical testing, and proper disposal of components
containing unknown fluids. SHURflo request this in order to protect the
environment and personnel from the hazards of handling unknown fluids.
Carriers, including the U.S.P.O., airlines, UPS, ground freight, etc., require
specific identification of any hazardous materials to be shipped.
Failure to do so may result in a substantial fine and/or prison term. Check
with your shipping company for specific instructions.
Visit our Web Site at http://www.shurflo.com
Shurflo reserves the right to update specifications, change prices, or make
substitutions without notice.
SHURflo
5900 Katella Avenue
Cypress,CA 90630
Phone 562-795-5200
Toll Free 800-854-3218
Fax562-795-7554| East
52748 Park Six Court
Elkhart, IN 46514-5427
Phone 562-795-5200
Toll Free 800-854-3218
Fax574-264-2169| SHURflo
Europe, Middle East, Africa
Pentair Water Belguim bvba
Industriepark Wolfstee, Toekomstlann 30
B-2200 Herentals, Belguim
Phone +32-14-283500
Fax + 32-14-283505
---|---|---
FLOW TECHNOLOGIES GROUP
5900 Katella Ave. • Cypress, CA 90630
Phone:800-854-3218 •
562-795-5200 • Fax:
562-795-7554
www.shurflo.com
911-551 Rev. B 10/09 ECO 16599
© SHURflo 1999-2009 All Rights Reserved