Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

FLEX VANE IMPELLER PUMP

CAUTION DO NOT pump flammable liquids. Do not pump in flammable or explosive environments.

Mounting
The pump can be positioned up to 7.5 feet (2.3 meters)
above the tank liquid level. Consider a location that allows easy access if maintenance is required. The pump should not be located in an area less than one cubic foot unless adequate ventilation is provided.
CAUTION   Excessive heat may trigger the integral thermal breaker and interrupt operation. When the motor temperature drops, the thermal breaker may restart the pump without warning.

CAUTION To prevent electrical shock, protect pump from rain or washdown. Flex vane pumps are not waterproof.
The pump may be mounted in any position. If mounting the pump vertically, the pump head should be in the down position so that in the unlikely event of a leak, water will
not enter the motor.
Use# 8 hardware to fasten the pump. The mounting feet are intended to isolate the pump from the mounting surface; overtightening will reduce the ability to isolate  vibration and noise.

Electrical
The pump should be on a dedicated circuit. Use correct fuse and wire size as specified in the following table.
Increase wire size to 12 AWG on 3000-050 if wire length exceeds 20 feet.

VOLTAGE STOCK# FUSE WIRE LEADS WIRE SIZE

12VDC| 3000-050| 15Amp| Red (+ pos)| 14 AWG
12VDC| 3000-350| n/a| Black (- neg)| 1.6 mm Dia.
115VAC| 3000-100| n/a| 3 prong plug with ground|

For 3000-050, an “on/off” switch rated at or above 15amps is recommended. The switch must interrupt current flow on the (+ red) positive lead. Marine applicationsshould use U/L approved marine duty (ignition protected)switches and wiring standards.
On 12 VDC models 3000-050 and -350, the black (-) negative lead should be the same gauge as the red (+) positivelead, and be connected to a known ground. 3000-100must be connected to a properly grounded three-prong115 VAC receptacle.

Plumbing
SHURflo recommends 1/2” (13mm) I.D. flexible high pressure tubing to both ports. Pump ports should not be connected to rigid pipe. Rigid pipe may crack ports or transmit excessive noise.
Make sure washer in inlet fitting is clean and in good condition. Vacuum leaks on the inlet side will cause a “no prime” condition.
Installation of 2522-3300 50 mesh in-line strainer on the inlet side is recommended to prevent foreign debris from entering the pump. Failure due to debris is not covered under the SHURflo limited warranty.

Operation

NOTE DO NOT run pump dry. Pump requires liquid for lubrication. If pump does not prime within 20 seconds, recheck installation and plumbing. Failure due to dry  running is not covered under the SHURflo limited warranty. To help priming, pour one ounce (30 ml) of liquid in inlet port.
Pump should prime within 20 seconds. If not, turn off the pump and do the following:
Disconnect inlet hose at pump.
Pour one ounce (30 ml) of liquid into inlet port.
Check washers in inlet hose and make sure inlet is airtight.
Make sure inlet and discharge lines are free of kinks and restrictions.
Make sure pump is less than 7.5 ft (2.3 m) above the liquid source.
On older pumps that do not prime, replace the impeller with SHURflo P/N 94-120-00 impeller/seal kit.
Pump will deliver approximately 3.8 gallons (14 liters) per minute when discharge is not restricted. As discharge is restricted, pressure increases, and flow decreases. To prevent motor over heating, do not operate pump at a discharge pressure of more than 12 psi (.8 bar) or discharge lift of more than 28 feet (8.5 meters). Motor is rated for intermittent duty only.

Winterizing
If water is allowed to freeze in the system, serious damage to the plumbing and the pump may occur. The best guarantee against damage is to drain the water system.
Failures of this type will void the warranty.

INDUSTRIAL PRODUCT LIMITED WARRANTY
SHURflo Industrial series pumps and products are warranted to be free of defects in material and workmanship under normal use, for a period of one (1) year from the date  of manufacture, or one (1) year of use, with proof of purchase. This limited warranty will not exceed two (2) years, in any event.
The limited warranty will not apply to pumps/products that were improperly installed, misapplied, damaged, altered, incompatible with fluids or components not manufactured by SHURflo.
All Industrial pumps/products must be flushed of any chemicals before shipping. All warranty considerations are governed by SHURflo’s written Return Policy.
Returns are to be shipped postage prepaid to either service center; SHURflo Cypress, CA or Elkhart, IN. SHURflo shall not be liable for freight damage incurred during  shipping. Package returns carefully.
SHURflo’s obligation under this warranty policy is limited to the repair or replacement of the pump/ product. All returns will be tested per SHURflo factory criteria.  Products found not defective (under the terms of this limited warranty) are subject to charges paid by the returnee for the testing and packaging of “tested good” non- warranty returns.
No credit or labor allowances will be given for pumps or products returned as defective. Warranty replacements will be shipped on a freight allowed basis. SHURflo reserves  the right to choose the method of transportation.
This limited warranty is in lieu of all other warranties, expressed or implied, and no other person is authorized to give any other warranty or assume obligation or liability on  SHURflo’s behalf. SHURflo shall not be liable for any labor, damage or other expense, nor shall SHURflo be liable for any indirect, incidental or consequential damages of  any kind incurred by the reason of the use or sale of any defective product or part. This limited warranty covers industrial products distributed within the United States of America. Other world market areas should consult with the actual distributor for any deviation from this document.

RETURN POLICY
All Industrial pumps/products must be flushed of any chemical (ref. OSHA Section 1910.1200 (d)(e)(f)(g)(h)) and hazardous chemicals must be labeled / tagged before being shipped to SHURflo for service or warranty consideration. SHURflo reserves the right to request a Material Safety Data Sheet from the returnee for any pump/product it  deems necessary. SHURflo reserves the right to “disposition as scrap” pumps/products returned which contain unknown fluids. SHURflo reserves the right to charge the  returnee for any and all costs incurred for chemical testing, and proper disposal of components containing unknown fluids. SHURflo request this in order to protect the environment and personnel from the hazards of handling unknown fluids.
Carriers, including the U.S.P.O., airlines, UPS, ground freight, etc., require specific identification of any hazardous materials to be shipped.
Failure to do so may result in a substantial fine and/or prison term. Check with your shipping company for specific instructions.

Visit our Web Site at http://www.shurflo.com
Shurflo reserves the right to update specifications, change prices, or make substitutions without notice.

SHURflo
5900 Katella Avenue
Cypress,CA 90630
Phone 562-795-5200
Toll Free 800-854-3218
Fax562-795-7554| East
52748 Park Six Court
Elkhart, IN 46514-5427
Phone 562-795-5200
Toll Free 800-854-3218
Fax574-264-2169| SHURflo Europe, Middle East, Africa
Pentair Water Belguim bvba
Industriepark Wolfstee, Toekomstlann 30
B-2200 Herentals, Belguim
Phone +32-14-283500
Fax + 32-14-283505
---|---|---

FLOW TECHNOLOGIES GROUP
5900 Katella Ave. • Cypress, CA 90630
Phone:800-854-3218562-795-5200 • Fax: 562-795-7554
www.shurflo.com
911-551 Rev. B 10/09 ECO 16599
© SHURflo 1999-2009 All Rights Reserved

Documents / Resources

| PENTAIR 3000 Flex Vane Impeller Pump [pdf] Instruction Manual
3000 Flex Vane Impeller Pump, 3000, Flex Vane Impeller Pump, Vane Impeller Pump, Impeller Pump, Pump
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Pentair User Manuals

Related Manuals