dol SENSORS DOL 104 Humidity Sensor User Guide

June 9, 2024
dol SENSORS

dol SENSORS DOL 104 Humidity Sensor

PRODUCT DESCRIPTION

DOL 104 is a high-precision sensor for measuring relative humidity. It is intended for application in livestock houses but is also well suited for a number of industrial applications

MAINTENANCE

IMPORTANT
Clean DOL 104 using water and a brush. Do not use:

  • High-pressure cleaner
  • Highly compressed air
  • Solvents
  • Corrosive/caustic agents
  • Alcohol-based disinfectants
  • During cleaning and disinfection, the sensor must be protected using a protection cap and be placed in vertical position.
  • After the sensor has been exposed to water and condensation, the sensor requires time during which the relative humidity is less than 80% in order to measure correctly.
  • Do not bend the sensor as this would inflict permanent damage on the electronics of the sensor. dol-sensors reserve the right to change this document and the product herein described without further notice.

LED

Green

|

Red

| LED/LIGHT PROTOCOL

Status

---|---|---
ON| | Operation OK
Flash| | Outside normal range

(below 10% RH or exceeding 95% RH)

| ON| Connection error Load error, Fig 4.
| Flash| Sensor defect Over/under voltage alarm Overload

INSTALLATION

For optimum mounting of the sensor, use mounting clips or mount it free- hanging in the cable. The sensor element requires free air passage.
See Figure 1. Mount the sensor so it is not exposed to direct sunlight, as this would affect the measurement.
REMEMBER TO PUT ON A PROTECTION CAP BEFORE MOUNTING THE CABLE.dol-
SENSORS-DOL-104-Humidity-Sensor-FIG-3

Table 1: Signals and wire colors in other products. L USER

DOL 14 DOL 14 HQ DOL 114 DOL 104
Black = +13-24V DC White = +13-28V DC
Brown = +11-30V DC Brown = +11-30V DC
Brown = 0…10V / %RH Green = 0…10V / %RH **White
=0…10V / %RH** White =0…10V / %RH
No temperature output No temperature output Black =0…10V / °C

No temperature output
Blue = GND (0V)| | Brown = GND (0V)| | Blue = GND (0V)| **| Blue = GND (0V)**

TECHNICAL DATA

Measuring range 0 – 100 % RH
Accuracy ± 2% RH (40–85 %) ± 3% RH (10-95 %) at 0-40 °C *
Output signal 0.16 mA / % RH
Time constant T 63 20 s at 0.5 m/s air velocity
Supply voltage 11 – 30 V DC
Supply current max. 35 mA
Load See Figure 4.
Recommended load 500 kΩ at 24 V DC supply voltage
Output current 20 mA (current limited)
Temperature, operation and storage – 40 °C – 60 °C
IP classification IP 67
Cable 2 m. 3 x 22 AWG / 0.34 mm2
Shipment weight ex. connector 150 g
Measure, shipment 275 × 200 × 20 mm
  • After direct water exposure and condensation a period with less than 80%RH is needed for correct measurement.

dol-SENSORS-DOL-104-Humidity-Sensor-FIG-4

  • 2016.06.17
  • 604240
  • 16.08
  • EN
  • Made in Denmark
  • dol-sensors a/s Hedelund 4, Glyngøre 7870 Roslev Denmark Tlf. +45 72 17 58 88 Fax +45 72 17 59 59www.dol-sensors.com