Components
- Float Switch
- Handle
- Motor
- 1-1/2 in. (38.1mm) Discharge
- Base
- Check Valve
Included with CMXWUSD62313 or sold separately under part no. CMXWUSDCV69502
Safety Guidelines
Carefully read, understand and follow all safety instructions in this manual.
Retain this manual for future reference
This is the safety alert symbol. When you see this symbol, look for one of the
following signal words.
Important
Read these warnings carefully. Know the application and limitations of this
pump. Failure to follow these warnings could result in serious bodily injury
and/or property damage.
DANGER: Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE: Indicates to address practices not related to personal injury.
WARNING RISK OF ELECTRICAL SHOCK: Disconnect and lockout power supply
before removing existing pump or installing or servicing this pump.
WARNING RISK OF ELECTRICAL SHOCK: This pump is supplied with a grounding
conductor and grounding type attachment plug. To reduce the risk of electric
shock, connect only to a properly grounded GFCI receptacle.
WARNING RISK OF ELECTRICAL SHOCK: Connect only to a receptacle that is
adequately rated for the voltage and amperage of this pump.
WARNING: The installation of this pump must be in accordance with the
National Electric Code (NEC), Uniform Plumbing Code (UPC), International
Plumbing Code (IPC) as well as all applicable local codes and ordinances.
WARNING: Do not install this pump in any location classified as hazardous
by the National Electrical Code, ANSI/ NFPA70.
DANGER: Do not use this pump to pump corrosive, flammable or explosive
fluids such as gasoline, kerosene, etc. Do not use this pump in flammable or
explosive environments. Use only with liquids compatible with pump component
materials.
WARNING RISK OF ELECTRICAL SHOCK: This pump has not been investigated for
use in swimming pool or marine areas.
WARNING RISK OF ELECTRICAL SHOCK: Do not use the power cord to remove or
lower the pump into the basin. The cord may pull apart exposing bare wires
which could cause a fire or electrical shock. Use the handle supplied with the
pump for installing and removing the pump from the basin.
WARNING: Don’t expose the pump to freezing temperatures. Discharge lines
exposed to freezing temperatures should be positioned with a downward slope to
prevent freezing.
WARNING: All wiring and electrical connections must be performed by a
qualified electrician.
WARNING: Make certain that the electrical outlet is within the reach of
the power supply cord. DO NOT USE AN EXTENSION CORD.
WARNING: Do not run the pump dry. This pump relies on water for
lubrication and cooling. Running the pump dry can cause the pump to overheat
and risks the possibility of burns to anyone that handles the pump. Running
the pump dry will void the warranty.
WARNING: Do not use this pump for potable/drinking water. Use only in
applications for which the pump is designed.
WARNING: According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause cancer and birth
defects or other reproductive harm.
WARNING: DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN. The
3-prong plug must be inserted into a mating 3-prong grounded receptacle. If
the installation does not have such a receptacle, it must be changed to the
proper type, wired and grounded in accordance with the National Electrical
Code and all applicable local codes and ordinances.
WARNING: This pump is not intended to pump water softener discharge
(brine) or condensate high efficiency appliances. These liquids are corrosive
and could cause damage to the pump and will void the warranty.
WARNING: Keep hands clear of suction and discharge openings. To prevent
injury, never insert fingers into pump while it is plugged in.
WARNING: Do not handle this pump with wet hands or while standing on wet
or damp surfaces or in water.
CAUTION: If a flexible discharge hose is used, make sure the pump is
secured in the basin to prevent movement.
Failure to secure the pump could result in flooding from switch malfunction.
CAUTION: This pump motor is equipped with an automatic resetting thermal
protector and may restart unexpectedly.
NOTICE: This pump is not designed as a waterfall, pond or fountain pump.
Use of this pump for waterfalls, ponds or fountains will void the warranty.
Description
This sump pump is designed to remove ground water from residential sump pits. The motor is oil cooled and hermetically sealed. A float switch is provided for automatic operation and is equipped with a 10 ft., 3-prong grounding type power cord.
Specifications
| CMXWUSD62348
CMXWU5D62346| CMXWUSD62313| CMXWUSD62558
CMXWU5D62556
---|---|---|---
Check Valve| Sold Separately| Included| Sold Separately
HP| 1/3| 1/3| 1/2
Volts| 120 Volt AC| 120 Volt AC| 120 Volt AC
Amps| 6.| 6.| 6.
Hz| 60| 60| 60
Phase| 1| 1| 1
Discharge Size| 1-1/2 in. (38.1mm) FNPT| 1-1/2 in. (38.1mm) FNPT| 1-1/2 in.
(38.1mm) FNPT
Max. Solids Handling| 3/8 in. (9.5mm)| 3/8 in. (9.5mm)| 3/8 in. (9.5mm)
Liquid Temp. Range| 35°F – 120°F (1.67°C – 48.9°C)| 35°F – 120°F (1.67°C –
48.9°C)| 35°F – 120°F (1.67°C – 48.9°C)
Cord Length| 10 ft. (3.05m)| 10 ft. (3.05m)| 10 ft. (3.05m)
Pump Construction| Thermoplastic| Thermoplastic| Thermoplastic
Impeller| Thermoplastic| Thermoplastic| Thermoplastic
Motor Shaft| Stainless Steel| Stainless Steel| Stainless Steel
Shaft Seal| Carbon/Ceramic/
Stainless Steel| Carbon/Ceramic/
Stainless Steel| Carbon/Ceramic/
Stainless Steel
Fasteners| Stainless Steel| Stainless Steel| Stainless Steel
Max Vertical Lift| 24 ft. (7.3m)| 24 ft. (7.3m)| 26 ft. (7.9m)
Max. PSI| 10.| 10.| 113
| CMXWUSD62348| CMXWUSD62313| CMXWUSD62558
---|---|---|---
Switch Type| Vertical| Vertical| Vertical
Switch On Level
(Factory Set)| 8.5 in. (215.9mm)| 8.5 in. (215.9mm)| 8.5 in. (215.9mm)
Swicth Off Level
(Factory Set)| 3 in. (76.2mm)| 3 in. (76.2mm)| 3 in. (76.2mm)
| CMXWUSD62346| CMXWUSD62556
---|---|---
Switch Type| Tethered| Tethered
Switch On Level
(Factory Set)| 8.5 in. (215.9mm)| 8.5 in. (215.9mm)
Switch Off Level
(Factory Set)| 3 in. (76.2mm)| 3 in. (76.2mm)
Installation
WARNING: Always disconnect the power source before attempting to install,
service or perform maintenance on the pump. Failure to do so may result in
fatal electrical shock.
NOTICE: Your pump is designed and built to give you reliable performance
and long life. It will pump water automatically for years when properly
installed in the right environment.
NOTICE: A qualified electrician must perform all wiring.
Remove old pump (if necessary):
- Make sure power supply is disconnected.
- After power is off, remove the old pump. When you are installing a new pump, this is a good time to inspect and replace any damaged piping. Be sure to clean all debris
and dirt out of the sump basin before installing your new pump.
CAUTION: Before installing a new pump, be certain a grounded 120V AC
outlet is installed within 6 ft. (1.83m) of your sump basin.
Install new pump:
-
Set your new pump in the bottom of the sump basin.
The pump should be placed on a solid foundation. Do not place the pump directly on the ground or on sandy or rocky surfaces. Sand/silt and small stones may clog or
cause damage to your pump. -
Make sure the float switch operates freely from the bottom to top without coming in contact with the side of the sump basin. Contact with the side of the sump
basin may cause the float to malfunction and the pump will not operate as intended. -
It is highly recommended to install a full flow, swing-type check valve (Included only on model CMXWUSD62313) in the discharge line. For ease of future removal or
maintenance it is recommended to install the check valve above the cover of the sump basin. A new check valve will greatly increase the life of your pump. The check valve should be the same size as the pump discharge. -
Connect the pump and check valve together using PVC or ABS pipe and fittings. Corrugated drain hose is intended for temporary use and should not be used in a
permanent installation. Although there are many types of pipe that work adequately for this installation, PVC or ABS is recommended.
Figure 1:
- Full-flow swing type check valve*
- GFCI outlet
- Discharge Pipe
- Sump Basin
- Position pump so the float switch operates freely without touching the sides of the basin.
- (1) Included with CMXWUSD62313 only. (2,3,4) not included with all pumps or sold separately under part no. CMXWUSDCV69502
Install new pump – Cont
5. Test your installation after you have completed setting up the pump.
Insert switch’s piggy-back plug into outlet. Then, plug the pump into the
piggy-back plug as show in Figure 2. The pump should not run at this point. If
the pump runs, the switch is stuck in the upright position or the pump is
plugged directly into the outlet and not
through the piggyback switch plug. Fill the sump basin with water using
buckets or a hose. When the switch floats to the upright position, the pump
will turn on. The switch will turn off the pump when it reaches the down
position. Remember the switch must move freely without touching the sides of
the sump basin.
Operation
WARNING: The pump motor is thermally protected. It is not recommended for
pumping liquids over 120° F (48.9°C). The thermal overload protector will
automatically shut down the pump in an overheat situation. The pump will reset
itself once the pump cools down. This overload is designed as a safety device
and it will fail after repeated use. Normal operation is for fluids between
35° F – 120° F (1.7°C – 48.9°C).
WARNING: Do not let the pump run dry. This pump relies on water for
lubrication and cooling. Operating the pump without water may cause the motor
to overheat or cause damage to internal parts. It may also shorten the life of
your pump.
Automatic Operation:
- Connect the piggy-back plug of the float switch into a 120 volt grounded GFCI receptacle. See Figure 2.
- Connect the pump plug into the back of the piggy-back float switch plug. See Figure 2.
- Test your installation by filling the basin with water. Observe the float switch through at least one complete cycle to ensure it operates freely and does not contact the sides of the basin. If necessary, adjust the float switch or reposition the pump to ensure proper operation.
- This pump is equipped with an (A) anti-airlock hole. A stream of water will emit from this hole when the pump is operating. This is a normal feature of this pump. The anti-airlock hole should be cleaned periodically to prevent the pump from becoming air locked. See Figure 3.
Manual Operation:
- For manual operation or float switch failure, the pump power cord can be disconnected from the piggyback float switch plug and connected directly to the receptacle. This will bypass the float switch and the pump will run continuously. During manual operation the pump should be monitored at all times to ensure the pump does not run dry. When pumping is complete disconnect from receptacle.
Components
- Float Switch Plug
- Pump Plug
Maintenance
WARNING: Risk of electric shock. Always disconnect the power supply
before attempting to install, service or perform maintenance on the pump.
WARNING: All repairs must be made by a qualified technician.
CAUTION: This submersible pump contains oil which may become pressurized
and hot under normal operating conditions – allow the pump to cool for 2-3
hours before servicing.
- The pump motor is hermetically sealed in the housing and does not require any service. Disassembly of the motor housing or modification of the power cord voids the warranty.
- Periodically check the sump basin for accumulation of mud, silt, sand and foreign objects. Clean the basin as needed to prevent damage or clogging of the pump.
- Periodically check the intake for obstructions. Clean if necessary.
- Periodically inspect and clean the anti-airlock hole.
- Inspect the float switch for any accumulated sediment or debris that may inhibit it from operating properly. Clean if necessary.
- Inspect the power cord for signs of damage or wear. Do not operate the pump if the cord is damaged or worn.
- In applications where the pump may not activate for extended periods of time, it is recommended to cycle the pump at least once per month to ensure the pumping
system is working properly when needed.
Troubleshooting
Problem | Possible Causes | How To Ceffect |
---|---|---|
If the pump does not start or run | Pump is not plugged in; switch or breaker | |
is turned off | Plug pump in or turn on switch/breaker |
Check for blown fuses or tripped circuit breakers or t
tripped GFCI outlets| Replace fuse, reset circuit breaker, reset GFCI outlet
Float switch is defective| Check and replace if necessary
Motor thermal protector tripped| Allow pump to cool. Pump will reset
automatically.
Float switch is stuck or obstructed| Remove obstruction or position pump so
the float switch will operate freely.
The pump starts and stops too often| Back-flow of water from discharge
hose/pipe| Install or replace check valve. If check valve is installed, check
for broken or leaking valve and replace if necessary.
Float switch is defective| Replace float switch
If the pump runs, but moves little or no water| Clogged discharge hose/pipe|
Remove clog
Frozen discharge hose/pipe| Allow hose/pipe to thaw
Pump is air locked| Check airlock hole for clogs and clean if necessary
Low line voltage| Check wire size and increase if necessary
Check valve is stuck in the closed position| Inspect, repair or replace if
necessary
Check valve is installed backwards| Make sure check valve is installed in the
correct direction of flow
Clogged intake screen| Clean or replace screen
Worn, damaged or clogged pump parts| Inspect for wear, damage or clog and
clean or replace part if necessary
Discharge height exceeds pump capacity| See performance chart for pump
limitations
Pump does not shut off| Float switch is obstructed or stuck| Remove
obstruction
Defective float switch| Replace float switch
Performance
Height and/or piping restriction will reduce the pump output performance. It is recommended to use the same size or larger pipe as the pump discharge for optimum performance.
Gallons Per Hour At Discharge Height
Model| 0 ft.| 5 ft.| 10 ft.| 15 ft.| 20 ft.|
25 ft.| Max
Lift
---|---|---|---|---|---|---|---
CMXWUSD62348
CMXWUSD62313
CMXWUSD62346| 3500| 3200| 2600| 1950| 900| –| 24 ft.
CMXWUSD62558
CMXWUSD62556| 4100| 3700| 3200| 2500| 1500| 100| 26 ft.
Liters Per Hour At Discharge Height
Model| 0 m| 1.52 m| 3.05 m| 4.6 m| 6.1 m|
7.62 m| Max Lift
---|---|---|---|---|---|---|---
CMXWUSD62348
CMXWUSD62313
CMXWUSD62346| 13249| 12113| 9842| 7382| 3407| –| 7.32 m
CMXWUSD62558
CMXWUSD62556| 15520| 14006| 12113| 9464| 5678| 379| 7.92 m
Replacement Parts
For parts, contact customer support at
888-331-4569.
Reference| Description| CMXWUSD62348
CMXWUSD62313|
CMXWUSD62346
| CMXWUSD62558
CMIONUSD62556
---|---|---|---|---
1| Power Cord| 98101040| 98101040| 98101040
2| Shaft Seal| T00900035/36| T00900035/36| T00900035/36
3| Impeller| 98112002| 98112002| 681200124
4| Base| ACM200000| ACM200000| ACM200000
5| Intake Screen| ACM200002| ACM200002| ACM200002
6| Check Valve| Not Included| CMXWUSDCV69502| Not Included
*If motor fails, replace entire pump.
7| Vertical Float Switch Bracket| C30010179| C30010179| C30010179
8| Vertical Float Switch| 98103002| 98103002| 98103002
9| Tethered Float Switch| O10100001| O10100001|
- Part not available for replacement
Notes:………………
Limited Warranty:
Manufacturer warrants the products specified in this warranty to be free from
defects in material or workmanship for three (3) years from date of purchase.
During the
time period and subject to the terms and conditions, manufacturer will repair
or replace to the original user or consumer any portion of this product which
proves to be
defective due to materials or workmanship. At all times, manufacturer shall
have and possess the sole right and option to determine whether to repair or
replace defective
equipment, parts or components. Manufacturer has the option to inspect any
product returned under warranty to confirm that the warranty applies before
repair or
replacement under warranty is approved. This warranty sets forth
manufacturer’s sole obligation and purchaser’s exclusive remedy for defective
product. For warranty
consideration, call 888-331-4569.
Warranty Period:
If, within the duration of product use by the original user, this product
proves to be defective due to materials or workmanship, the product shall be
repaired or replaced at the manufacturer’s option, subject to the terms and
conditions set forth in this warranty statement. Proof of purchase is required
for warranty consideration. In the absence of suitable proof of the purchase
date, the effective period of this warranty is 12 months from the product’s
date of manufacture. If a warranty replacement pump is provided
to the customer, the warranty of the replacement pump will be subject to the
original purchase date of the original pump.
Labor, ETC, Costs: The manufacturer shall IN NO EVENT be responsible or
liable for the cost of field labor or other charges incurred by any customer
in removing and/or affixing any product, part, or component thereof.
Product Improvements: The manufacturer reserves the right to change or
improve its products or any portions thereof without being obligated to
provide such a change or improvement for units sold and/or shipped prior to
such change or improvement.
General Terms and Conditions: This warranty shall not apply to damage due
to acts of God, normal wear and tear, normal maintenance services and the
parts used in connection with such service, lightning or conditions beyond the
control of the manufacturer, nor shall it apply to products which, in the sole
judgment of the manufacturer, have been subject to negligence, abuse,
accident, misapplication, tampering, alteration; nor due to improper
installation, operation, maintenance or storage; nor to excess of recommended
maximums as set forth in the instructions.
General Terms and Conditions – Cont:
Warranty will be VOID if any of the following conditions are found:
- Product is used for purposes other than those for which it was designed and manufactured. Pump has been used for pumping liquids above 120°F (48.9°C).
- Product is not installed in accordance with applicable codes, ordinances, and good trade practices.
- Product is connected to voltage other than indicated on nameplate or labels.
- Pump has been exposed to but not limited to the following: sand, gravel, cement, grease, plaster, mud, tar, oil, gasoline, solvents or other abrasive or corrosive substances.
- Pump has been allowed to operate dry (liquid supply cut off ).
Disclaimer:
Any oral statements about the product made by the seller, the manufacturer,
the representatives, or any other parties do not constitute warranties, shall
not be relied upon by the user, and are not part of the contract for sale.
Seller’s and the manufacturer’s only obligation, and buyer’s only remedy,
shall be the replacement and/or repair by the manufacturer of the product as
described above. NEITHER SELLER NOR THE MANUFACTURER SHALL BE LIABLE FOR ANY
INJURY, LOSS OR DAMAGE, DIRECT, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT
NOT LIMITED TO, INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS, LOST
SALES, INJURY TO PERSON OR PROPERTY, OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL
LOSS), ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT, AND THE
USER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT. Before using, the
user shall determine the suitability of the product for their intended use,
and user assumes all risk and liability whatsoever in connection therewith.
THE WARRANTY AND REMEDY DESCRIBED IN THIS LIMITED WARRANTY IS AN EXCLUSIVE
WARRANTY AND REMEDY AND IS IN LIEU OF ANY OTHER WARRANTY OR REMEDY, EXPRESSED
OR IMPLIED, WHICH OTHER WARRANTIES AND REMEDIES ARE HEREBY EXPRESSLY EXCLUDED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, TO THE EXTENT EITHER APPLIES TO A PRODUCT
SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESSED WARRANTIES GIVEN
ABOVE.
Some states and countries do not allow the exclusion or limitations on how
long an implied warranty lasts or the exclusion or limitation of incidental or
consequential
damages, so the above exclusion or limitations may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights
which vary from state
to state.
Manufactured under license by:
Pedrollo Group Inc.
45 Maryland Ave East St. Paul, Minnesota 55117 © 2022 CRAFTSMAN.
CRAFTSMAN® is a registered trademark of Stanley Black & Decker, Inc., and are
used under license.
Product may differ from that pictured. Does not affect function.
Form #: 601102
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>