ZZIPP GROUP ZZFM3000 Stage Smoke Machine User Manual

June 4, 2024
ZZIPP GROUP

ZZIPP GROUP ZZFM3000 Stage Smoke Machine

Thanks for purchasing this ZZIPP product, please read this instruction carefully to understand how to operate the product correctly. Please store this instruction in a safe place after reading as a reference in the future.

SAFETY INSTRUCTIONS

To reduce the risk of electric shock, do not remove the cover or the side. Always contact qualified personnel for repairs.

To reduce the risk of fire and electric shock, do not expose the appliance to moisture and direct contact with liquids.

Transport the product only using the handles. Don’t shake it. To avoid the risk of fire or shock do not expose the product to rain or direct and excessive humidity. If the environment is much colder than the temperature of this product, wait for it to adjust to room temperature before turning it on. Do not use the product for permanent installations. Only connect the product to circuits grounded and protected. Always disconnect it from the power supply before cleaning it or replacing the fuse. Replace the fuse with another of the same type and the same rated voltage. Do not clean the product with solvents or aggressive detergents. Use a soft, clean cloth. Before connecting the product to a power supply, make sure the cable is not damaged. Make sure that the voltageof the electrical outlet is within the range indicated on the product (on the housing or on a sticker). Never disconnect the product from the socket by pulling the cord. Always make sure that the product is used in a location with adequate ventilation with at least 50 cm of space from adjacent surfaces. Make sure that none of the ventilation openings are obstructed. Do not use the product at temperatures above 104 ° F / 40 ° C. Keep flammable materials away from the product during use. Do not touch the product when it is switched on or immediately after switching off. The product and its housing can reach high temperatures. If you experience serious problems while using the product, stop using it immediately. Do not open the product housing. Contains parts that cannot be repaired by the user and such opening would void the warranty.

CHECK THE CONTENTS

  • ZZFM3000
  • Operating instructions
  • Power cable
  • Wireless remote controller

FEATURES

As one of the most professional fog machines, ZZFM3000 is a massive fog generator and delivers a powerful fog to create the best atmospheric effect. It equips with “microprocessor, electronic temperature control system, high precision temperature control PCB and brand new professional heating elements. Built-in LCD control panel enable timer function with adjustable fog output. Fill up a venue within very short time. Smooth and stable smoke even at 1% output.

  • Available for timing, output 1-100% precisely adjustable;
  • One heater with two output nozzles, two pumps system;
  • Enormous output, fill a venue within seconds. 100% output 30 seconds continuous work;
  • Super stable and durable;
  • No fluid protection;
  • Strong anti-interference ability;
  • Anti-loose powercon;
  • Built-in LCD control, wireless control and DMX control. Equipped with 3-pin and 5- pin DMX sockets.

INSTALLATION

  1. After ensuring all the accessories are intact, position the machine on a flat surface, and open the cover of the road case in front.
  2. Press the fluid tank’s quick connector by thumb and forefinger, and take it out quickly to disconnect the tube and the fluid tank. Take out the tank and uncover the cap. Pour the high quality fluid into the tank carefully, then tighten the cap. Put the tank into the machine and push the connector lightly to connect the tube and fluid tank. The machine which is broken because of using poor quality fluid will not have guarantee.
  3. Connect the power cord to the machine. Please make sure of the required electricity voltage and that electricity outlet is grounded.
  4. There is ON/OFF power switch for this unit, When turn ON, the LCD panel will display “WARMING UP” .
  5. It requires about 7 minutes for heating up. When the process of heating up finishes, the LCD display will show “READY TO FOG”

OPERATION

Connect the product to the power supply and then turn it on. Wait until the heating element has reached the operating temperature. 5. It requires about 7 minutes for heating up. When the process of heating up finishes, the LCD display will show “READY TO FOG”. The control is now carried out either by DMX, remote control or by operation on the device itself

DISPLAY AND MENU’ BUTTONS

The device has 4 operating keys and an LCD display on which all settings can be addressed and read.

BUTTON FUNCTION EXPLANATION

MENU’

| Interval set (5-200sec)|

TIMER MODE SETTING

Duration set (5-200sec)
Timer out (1-100%)
Volume out (1-100%)|
Wireless ON/OFF
DMX Add (001-512)
Fluid sensor ON/OFF
[TIMER] [UP]| Up/Activate Timer function
[VOLUME] [DOWN]| Down/Activate Volume function
[STOP]| Stop / Exit

  • At any setting pages, press STOP to exit or return to the page one.
  • When the unit is working, press STOP to stop running and return to the page one.
  • After entering into different setting pages, press UP and DOWN to change the value.
  • When it is in page one, press TIMER button to enter into timer mode,
  • The detail will be as below:
  • “Interval xxx s”: interval time setting
  • “Duration xxx s”: duration time setting
  • When in TIMER mode, the fog output will be depended on Timer Out.
  • When press button VOLUME, the timer mode is invalid, and the fog output will be based on the setting of Volume out.

Set interval
To set the interval, press “Menu” until “Interval set” appears on the display. Then use the Up/Down buttons to set the fog pause from 5 to 200 seconds. This setting is required if you want to use the timer mode.

Setting the fog duration
To set the duration, press “Menu” until the display shows “Duration set”. Use the Up/Down buttons to set the fog duration from 1 to 200 seconds. This setting is required if you want to use the timer mode.

Setting the Fog Level for Timer Mode
To set the fog quantity for the timer mode, press “Menu” until the display shows “Timer out”. Use the Up/Down buttons to set the fog quantity from 1 to 100%. This setting is required if you want to use the timer mode.

Setting the Fog Level for Volume Mode
To adjust the fog quantity, press “Menu” until the display shows “Volume out”. Use the Up/Down buttons to adjust the fog volume from 1 to 100%. This setting is required if you want to use the option Volume (Continuous Mode).

Setting the DMX address
To set the DMX address, press “Menu” until the display shows “DMX ADD xxx”. Then use the Up/Down buttons to set the value from 001 to 512.

Activating/deactivating the liquid sensor
Press “Menu” until “Fluid sensor” appears in the display. Use the Up/Down buttons to activate or deactivate the fluid sensor (On/off). When the Fluid sensor is activated, the display shows “Ready to Fazer S”. If the Fluid sensor is deactivated, the display shows “Ready to Faze”.

Timer Mode
In the timer mode, the fog machine will automatically emit fog. The time intervals, duration and fog volume depend on the corresponding menu settings. Press the TIMER button, to activate the timer mode. The display indicates the set time interval: Interval xxx s The unit counts down to 0 seconds and emits fog. To deactivate the timer mode, press the Stop button.

Volume (Continuous Mode)
Press the VOLUME button, to activate continuous fog output. The display indicates Volume followed by the value that was set in menu item “Volume Out”: Duration xxx s To stop the fog output, press the Stop button.+

REMOTE CONTROL MODE

The device can be managed remotely using the remote control included. To do this, plug the wireless receiver into the connection on the rear of the unit. Please note that the device cannot be controlled by remote control if it is connected to DMX. The remote control has 2 or 4 buttons: Press and hold one of the buttons to trigger a permanent fog emission. To stop the fog output, release the button.

The remote control has 2 or 4 buttons: Press and hold one of the buttons to trigger a permanent fog emission. To stop the fog output, release the button

DMX MODE

Resistance 120 ohm // ¼ w between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. Connect the DMX input of your device to the DMX output of your DMX controller, your DMX software or the DMX output of a device already in your DMX chain. Always use a DMX cable with impedence 110 Ohm for this connection. Address the device according to your DMX configuration. The following table shows the respective DMX modes of the individual devices with the corresponding values and functions:

DMX CHANNEL DMX SCALE FUNCTION
CH1 000-005 OFF
006-255 1-100% FOG OUTPUT

SERVICE AND MAINTENANCE

  1. Please use high quality fluid. It will prolong the lifetime of machines. To avoid danger. The machine should be serviced by professional.
  2. Excessive dust, fluid residue and dirt will degrade performance and cause overheating. Remove dust from air vents with air compressor, vacuum or a soft brush. The casing can be cleaned by the damp cloth.
  3. Before storing, run distilled water through the heating system to help avoid blocking the electric heating element.
  4. t is recommended to run the machine on a monthly basis in order to achieve best performance and output condition.
  5. All smoke machines will be blocked because of the inferior liquid or frequent use. Periodic maintenance is necessary for long term use. After 40 hours continuous working, please spray 10-15 times with a detergent composed of 35% vinegar and 65% distilled water.
  6. Please properly operate the machine comply with user manual.

SPECIFICATIONS

  • Power supply AC220-240V, 50HZ
  • Power consumption 3000 Watt
  • Power connections PowerCon compatible
  • Fuse 250V/15A
  • Heating time 5 minutes
  • Fluid consumption 300ml/min
  • Tank capacity 6 Liters
  • Output range 10m
  • DMX-Connector DMX-In/Out (3pol)
  • DMX-channels 1 channel-mode
  • Dimensions (with bracket) L x W x H 510 x 331 x 335 mm
  • Weight 15,4 Kg

CLEANING

The heating element should be cleaned regularly (every 30 operating hours) to avoid deposits. In addition, regular cleaning of lines and nozzles is strongly recommended. Please use only high quality cleaning fluids!

  • Empty the fog machine and pour the cleaner into the tank as delivered.
  • Operate the fog function of the machine a few times in a well ventilated place.
  • Adapt the number of required repetitions to the degree of soiling.
  • Remove the cleaner completely and rinse the tank properly with distilled water.
No. DESIGNATION No. DESIGNATION
1 Fluid Tank 8 On/Off-Switch
2 Tank cap 9 Fuse
3 Mounting bracket 10 Power cord (PowerCon compatible)
4 Locking screw 11 Menu buttons
5 Carrying handle 12 Display
6 Tank indicator 13 DMX-In/Out (3-pol)
7 Nozzle for fog output 14 Receiver remote control
DESIGNATION No. DESIGNATION
--- --- --- ---
1 Fluid Tank 8 On/Off-Switch
2 Tank cap 9 Fuse
3 Mounting bracket 10 Power cord (PowerCon compatible)
4 Locking screw 11 Menu buttons
5 Carrying handle 12 Display
6 Tank indicator 13 DMX-In/Out (3-pol)
7 Nozzle for fog output 14 Receiver remote control

TROUBLESHOOTING

The following overview serves as an aid for quick troubleshooting. If you are unsure, contact the manufacturer, the dealer or the corresponding specialist personnel. Never open the device on your own!

No function
Check the mains connection and the fuse

No fog output
Check the fill level of the fluid container

No reaction in DMX mode
Check the cable connections – Check your DMX address setting – If available, try an alternative DMX controller

No reaction in remote mode
Change the battery in your remote control – Ensure that the transmitter and receiver are at close and clear distances from each other. imported and distributed by:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>