Zipato PIR Sensor ne-nas-pd01zt.eu Manual PIR Sensor

October 28, 2023
Zipato

Zipato

PIR Sensor

SKU: ne-nas-pd01zt.eu

Quickstart

This is a ****

Alarm Sensor
for
CEPT (Europe)
.

Please make sure the internal battery is fully charged.

To add this device to your network execute the following action:
1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Presence detector and illuminance meter in one device. Zipato PIR motion sensor offers elaborate security and ambient sensing options.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

Reset procedure will delete all information on the ZWave network and ZWave controller or ZWave Gateway, and restore the sensor to factory default settings.1.Remove the device cover. 2.Make sure the sensor is powered. 3.Press and hold the button for 10 seconds, Led will blink once. 4.Release the button. Note: to use the reset procedure only when the primary controller is missing or inoperable.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.

Exclusion

1.Remove the device cover. 2.Make sure the sensor is powered. 3.Set ZWave controller or ZWave gateway into exclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter exclusion mode.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time
to save battery life time. Communication with the device is limited. In order to
communicate with the device, a static controller C is needed in the network.
This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller,
communication may become impossible and/or the battery life time is significantly
decreased.

This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the desired
wakeup interval and the node ID of the controller. If the device was included by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please perform
the following action:

You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 4 Z-Wave Plus Lifeline
2 4 GROUP 2 allows for sending control commands to associated devices such

as relay module, lighting, etc. This association group is configured through the advanced parameters no. 2, 3, 5 and 8. This Group Support: BASIC_SET
3| 4| GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORT_V4
4| 4| GROUP 4 allows for Send Sensor Binary Report to associated devices in this group. This Group Support: SENSOR_BINARY_REPORT_V2

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Sensitivity Level Setting

This parameter defines the sensitivity of PIR sensor. Its recommended to test thesensor with movements from the farthest end of the coverage area at the first timeof use. If movements cannot be detected sensitively, simply adjust the sensitivitylevel with this parameter. This parameter can be configured with the value of 8through 255, where 8 means high sensitivity and 255 means low sensitivity.
Size: 1 Byte, Default Value: 12

SettingDescription

8 – 255 PIR sensitivity

Parameter 2: ON/OFF Duration

_This parameter determines how long the associated devices should have ON status.For instance, if this parameter is set to 30 (sec), the PIR sensor will send aBASIC_SET command to associated device with value BASICSET level if PIR sensoris triggered and associated device will be turned on 30 seconds begore its turnedoff. This parameter value must be large as Parameter #. If user sets this parameterto default by Configure CC, the parameter # will be set to default value.
Size: 2 Byte, Default Value: 30

SettingDescription

5 – 600 Seconds

Parameter 3: BASIC SET LEVEL

_BASIC_SET command will be sent when PIR sensor is triggered. The receiver willtake it into consideration; for instance, if a lamp module is receiving the BASICSETcommand of which value is decisive as to how bright of dim level of lamp moduleshall be.
Size: 1 Byte, Default Value: 255

SettingDescription

0 – 99 Dim level
255 Previous non zero dim level

Parameter 4: PIR DETECTION FUNCTION ENABLED / DISABLED

This parameter can enable or disable the PIR sensor detecting function.Function: Enabled / Disabled PIR function
Size: 1 Byte, Default Value: 255

SettingDescription

0 DISABLE
255 ENABLE

Parameter 5: AMBIENT ILLUMINATION LUX LEVEL

_This parameter can set Lux value which determines when the light sensor isactivated. If the ambient illumination level falls bellow this value and a person movesacross or within the detection area, PIR sensor will send Z-Wave ON command (i.e.BASICset (value = parameter 3) to an associated device and activate it.
Size: 2 Byte, Default Value: 100

SettingDescription

0 – 1000 Lux

Parameter 6: RE-TRIGGER INTERVAL SETTING

This parameter can be used to adjust the interval of being re-triggered after the PIRsensor has been triggered. This parameter value must be less than Paramater #2.If user sets this parameter to default by Configure CC, the parameter #2 will be setto default value.
Size: 1 Byte, Default Value: 8

SettingDescription

1 – 8 Retrigger interval in seconds

Parameter 7: LIGHT SENSOR POLLING INTERVAL

This parameter can set the light sensor to measure ambient illumination levelinterval time. NOTE: This value must be less than Wakeup Interval Time!
Size: 2 Byte, Default Value: 180

SettingDescription

60 – 3600 Seconds

Parameter 8: 8

_If this parameter is set to 1 and when Lux level is less than the value defined byparameter #5, PIR sensor will send a BASIC_SET command frame (i.e. BASIC_SET(value = parameter 3) to an associated device and activate it. If Lux level is greater than thevalue defined by parameter #5, PIR sensor will not send BASICSET command frame.
Size: 1 Byte, Default Value: 0

SettingDescription

0 DISABLE
1 ENABLE

Parameter 9: AMBIENT ILLUMINATION LUX LEVEL REPORT

This parameter defines by how much Lux level must change in Lux to be reported tothe main controller.
Size: 2 Byte, Default Value: 1

SettingDescription

0 – 1000 lux

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 66 FW: 3.80
Z-Wave Version 6.51.06
Certification ID ZC10-18015916
Z-Wave Product Id 0x0131.0x0003.0x1089
Sensors Luminance
Supported Notification Types Home Security
Color White
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Manufacturer Specific V2
  • Notification V4
  • Powerlevel
  • Sensor Binary V2
  • Sensor Multilevel V7
  • Version V2
  • Wake Up V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Zipato User Manuals

Related Manuals