Zipato Smart energy plug-in switch ph-pan16.eu Manual

June 8, 2024
Zipato

Zipato

Smart energy plug-in switch

SKU: ph-pan16.eu

Quickstart

This is a
secure
On/Off Power Switch
for
CEPT (Europe)
.

To run this device please connect it to your mains power supply.

To add this device to your network execute the following action:
Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.Pressing On/Off button three times within 2 seconds will enter inclusion mode.

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

TheproductdocumentationstatesaSecurityEnabledZ-Wave Controllermustbeusedinordertofullyutilizetheproduct. SmartEnergyPlugInSwitchisasecurityenabledwireless switch, based on Z-Wave Plus technology.Z-Wave Plus enabled devicesdisplayingtheZ- WavePluslogocanalsobeusedwith it regardless of the manufacturer, and can also be used in other manufacturers Z-Wave enabled networks. Remote On/Off control oftheconnectedloadispossiblewithothermanufacturers wireless Controller. Each switch is designed to act as a repeater.Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstaclesandradiodeadspots.BecausetheSwitchsupports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. This Smart Energy Plug In Switch is able to detect instance wattage (3000W/230Vac) (13Ampere)andoverloadcurrent(14.5Awithresistiveload)of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and reconnect the switch will reset its overload condition to normal status.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.Pressing On/Off button three times within 2 seconds will enter inclusion mode.Within 1 second, press On/Off button again for 5 seconds.IDs are excluded.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.Pressing On/Off button three times within 2 seconds will enter inclusion mode.

Exclusion

Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.Pressing On/Off button three times within 2 seconds will enter exclusion mode.Node ID has been excluded.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 1| LifelineThe Switch can be set to send reports to associated Z-Wave devices. It supports one association group with one node support for Grouping

  1. For group 1, the Switch will report its latest status to Z-Wave Controller.Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.
    ---|---|---

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Watt Meter Report Period

Ifthesettingisconfiguredfor1hour(setvalue=720),the Switch will report its instant power consumption every 1 hour toGroup1node.Themaximumintervaltoreportitsinstant powerconsumptionis45hours(5s*32767/3600=45hr).When the setting is set at 0, the Switch will disable Watt auto report function. The default value is 720.
Size: 2 Byte, Default Value: 720

SettingDescription

0 0: Disable Watt Report
1 – 32767 1~32767:5s~45h

Parameter 11: Manual Switch Report Mode

_The default setting is Enable the function. Whenever the Switch ismanuallyswitchedonoroff,itwillsendBINARY_SWITCHREPORT to the node of group1.
Size: 1 Byte, Default Value: 1

SettingDescription

0 0 : Disable
1 1 : Enable

Parameter 12: Auto Report after Reset

_Whenever the Switch is repowered, it will check this parameter for if sending aBINARYSWITCH REPORT to the node of group1 or not. The default setting is Disable the function._
Size: 1 Byte, Default Value: 1

SettingDescription

0 0 : Enable
1 1 : Disable

Parameter 13: Adjustable overload

The overload current can be adjustable from 4.5A to 14.5A. The default value is 1450 for 14.5A. (1450 * 0.01A = 14.5A).
Size: 2 Byte, Default Value: 1450

SettingDescription

450 – 1450 1450*0.01A = 14.5A

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =6), the Switch willreportitsAccumulatedPowerConsumption(KW/h) every 1 hour to Group1 node. The maximum interval to report itsAccumulatedPowerConsumption(KW/h)is227.55days (10min*32767/1440=227.55 days). When the setting is set at 0, theSwitchwilldisableKWHautoreportfunction.Thedefault value is 6.
Size: 2 Byte, Default Value: 6

SettingDescription

0 0: Disable KWh Report
1 – 32767 1~32767:10min~227 days

Parameter 3: Threshold of current for Load caution

Thisisawarningwhenthecurrentofloadoverthepreset thresholdvalue,ifthesettingvalueis1300,whentheload current of Relay1 over this value, Swtich will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300.
Size: 2 Byte, Default Value: 1300

SettingDescription

10 – 1300 1300*0.01A = 13A

Parameter 4: Threshold of KWh for Load caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, the Switch will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

SettingDescription

1 – 10000 10000*1KWh = 1000 KWh

Parameter 5: Restore switch state mode

Whenever the AC power return from lost, the Switch will restore theswitchstatewhichcouldbeSWITCHOFF,LASTSWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

SettingDescription

0 0 : Switch off
1 1 : Last switch state
2 2 : Switch on

Parameter 6: Mode of Switch Off function

When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the On/Off function of include button will be disabled. The default setting is enable mode. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state.
Size: 1 Byte, Default Value: 1

SettingDescription

0 0: Disable
1 1: Enable

Parameter 7: LED indication mode

1.SHOW SWITCH STATE:When the Switch is on, LED is on. When the Switch is off, LED is off. The default setting is Show Switch State.2.SHOW NIGHT MODE:When the Switch is on, LED is off. When the Switch is off, LED is on.3.ONE FLASH MODE:WhenthestateoftheSwitchchanges,LEDwillturnonfor1 second.
Size: 1 Byte, Default Value: 1

SettingDescription

1 1 : Show switch state
2 2 : Show night mode
3 3: One flash mode

Parameter 8: Auto off timer

Whenever the Switch switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled.
Size: 2 Byte, Default Value: 0

SettingDescription

0 0 : Disable auto off function
1 – 32767 1-0x7FFF : 1s ~ 32767s

Parameter 9: RF off command mode

_Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALLOFF, is received, it could be interpreted as 4 variety of commands. The default setting is Switch Off.1.SWITCH OFF:It switches to OFF state. The default setting is Switch Off.2.IGNORE:The switch off command will be ignored.3.SWITCH TOGGLE:It switches to the inverse of current state.4.SWITCH ON:It switches to ON state.
Size: 1 Byte, Default Value: 0

SettingDescription

0 0 : Switch off
1 1 : Ignore
2 2 : Switch toggle
3 3 : Switch on

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.03
Z-Wave Version 6.51.09
Certification ID ZC10-17055605
Z-Wave Product Id 0x0131.0x0001.0x0029
Firmware Updatable Updatable by Consumer by RF
Electric Load Type Incandescent
Color White
Supported Meter Type Electric Energy
Switch Type Push Button
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Alarm
  • Association Grp Info
  • Association V2
  • Basic
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V2
  • Manufacturer Specific
  • Meter V3
  • Powerlevel
  • Protection V2
  • Security
  • Switch All
  • Switch Binary
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Zipato User Manuals

Related Manuals