KOMFORTHAUS Spirit Z-Wave Plus 4250848804063 Manual
- June 8, 2024
- KOMFORTHAUS
Table of Contents
- KOMFORTHAUS
- KOMFORTHAUS Spirit Z-Wave Plus
- SKU: 4250848804063
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KOMFORTHAUS
KOMFORTHAUS Spirit Z-Wave Plus
SKU: 4250848804063
Quickstart
This is a
secure
HVAC-Thermostat
for
UAE.
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Start Inclusion mode of your primary Z-Wave Controller.Press the Boost-Button.
Please refer to the
Manufacturers
Manual for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Easy control for water radiators from any Z-Wave ControllerFits most European water radiators (wide range of additional adaptors for different manufacturers available)FLiRS for quick response time LED Backlit LCDMetal nut for reliable connection to the radiator2 buttons for easy temperature regulationBattery level indicatorChild LockOver the Air updateUK-Mode for upside down installationOpen Window detectionAutomatic frost protection
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.Remove batteries.Press and hold boost button.While still holding boost button insert batteries.The LCD shows RES. Release boost button.To perform the factory reset press boost button.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Start Inclusion mode of your primary Z-Wave Controller.Press the Boost-Button.
Exclusion
Start Exclusion mode of your primary Z-Wave Controller.Now press and hold the boost button of the Spirit Z-Wave Plus for at least 5 seconds.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | Z-Wave Plus Lifeline |
---|
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: LCD invert
Inverts the LCD orientation
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Normal orientation |
---|---|
1 | LCD content inverted |
Parameter 2: LCD Timeout
Configures the timeout of the LCD.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | LCD always on |
---|---|
5 – 30 | LCD timeout in seconds |
Parameter 3: Backlight
Enables or disables the LCD-Backlight.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Backlight disabled |
---|---|
1 | Backlight enabled |
Parameter 4: Battery report
Enables or disables unsolicited battery reporting once a day.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Battery reporting disabled |
---|---|
1 | Battery reporting enabled |
Parameter 5: Measured temperature report
Reports the measured roomtemperature on change.
Size: 1 Byte, Default Value: 5
SettingDescription
0 | Reporting disabled |
---|---|
1 – 50 | Reporting Delta in 1/10 Celcius |
Parameter 6: Valve percentage report
Reports the valve percentage on change.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Reporting disabled |
---|---|
1 – 100 | Reporting Delta in percent |
Parameter 7: Window open detection
Configures the sensitivity of the window open detection.Sensitivity level: 1
low2 medium3 high
Size: 1 Byte, Default Value: 2
SettingDescription
0 | Detection disabled |
---|---|
1 – 3 | Sensitivity level |
Parameter 8: Measured temperature offset
Configures an offset for the measured temperature. Set the offset to -128
(0x80) if measured temperature is provided externally.
Size: 1 Byte, Default Value: 0
SettingDescription
-128 | Temperature is supplied externaly |
---|---|
-50 – 50 | Offset in 1/10 Celcius |
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Thermostat – HVAC |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 49 FW: 0.16:00.10 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-17115875 |
Z-Wave Product Id | 0x0148.0x0003.0x0003 |
Supported Notification Types | Power ManagementSystem |
Sensors | Air Temperature |
Thermostat HVAC Systems Supported | Heat Only |
Firmware Updatable | Updatable by Consumer by RF |
Thermostat Modes | Energy Save HeatHeat |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Basic
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md V3
- Manufacturer Specific
- Notification V8
- Powerlevel
- Protection
- Security
- Security 2
- Sensor Multilevel V5
- Supervision
- Switch Multilevel
- Thermostat Mode V3
- Thermostat Setpoint V3
- Transport Service V2
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.