HUMAN CARE Carl-Oskar Trolley Walker User Manual
- June 8, 2024
- HUMAN CARE
Table of Contents
HUMAN CARE Carl-Oskar Trolley Walker User Manual
Important!
You must read the user manual for your device prior to usage. Keep this
booklet and information handy for future use.
Symbols
WARNING symbol indicates a potentially hazardous situation which, if not avoided, could result in serious injury to the user or damage to property and/or the device itself.
INFORMATION symbol indicates recommendations and information for proper, trouble-free usage.
WEIGHT CAPACITY symbol indicates maximum user weight for the product. Do not exceed this weight in any circumstance.
CE MARKING symbol indicates product meets requirements of EU Directive 93/42/EEC (MDD) and/or EU Regulation 2017/745 (MDR).
RECYCLE according to local regulations.
MEDICAL DEVICE symbol indicates that the product is a medical device according to the definition of medical device in EU Directive 93/42/ EEC (MDD) and/or EU Regulation 2017/745 (MDR).
READ INSTRUCTIONS and ensure you fully understand them before using this product.
Product modification is not permitted. Before use, always check that the sling is not damaged or worn
Human Care’s products are continuously being developed and updated to provide our customers with the highest quality. We reserve the right to make design changes without prior notice. Always make sure that you have the most recent version of the manual which is available for downloading from our website at www.humancaregroup.com.
Contact your local distributor if you have any questions about the product and its use.
Notice to user/patient in case of serious incident
Any serious incident that has occurred in relation to the product, should be
reported to the local contact, who reports to the manufacturer, and the
competent authority of the country in which the user/patient is established.
Compliances and Standards
Human Care is an ISO 13485:2016 certified
Swedish medical device company. The Quality
Management System is in compliance with US 21 CFR part 820. The product is CE
marked in accordance with EU
Directive 93/42/EEC (MDD) and/or EU Regulation 2017/745 (MDR), as class I
medical device.
The CE mark is on the product.
This product has been tested in accordance with ISO 11199-2:2005.
About our products
On delivery
Check the following before using your new product:
- Check that no damage has occurred during transport (if this is the case, please immediately inform the delivery agent).
- Check that the number and type (s) of products detailed on the delivery certificate agree with the goods delivered.
- Check that the delivery is of the desired model and type of product.
Please contact us immediately in case of any delivery problem.
Return or refund
If any product has to be returned for any reason, please contact us to obtain
a claim number and advice on how to proceed. The goods should be returned in
complete and undamaged condition in their original packaging.
The following information should accompany any product on its return. The product’s identification number, delivery date, the date the user took possession of the aid, the date of the product’s last service, the person whom we should contact about the fault, whether it be the user or another, and the nature of the fault. Human Care HC AB reserves the right to inspect the returned product. If no fault can be found,the item will be returned to the user. Transport costs may then be chargeable
Product lifetime
The product´s expected lifetime is seven (7) years, if the product is used as
intended and maintained according to the manufacturer´s instructions,
depending on the intensity of use and maximum load applied during use. If the
product label is no longer legible, the product should be discarded
| Article number
---|---
| Maximum user weight
| Date of manufacture
| Address of manufacture
EAN| UPC code
| CODE 39 barcode, Serial number
| Read the manual
---|---
| Product width
| Indoor / outdoor use
| CE marking
MD| MD marking
Additional Warnings
Ensure that all bolts are securely fastened before using the rollator!
Brakes must be in the parked/locked position before sitting on the rollator!
DO NOT adjust brake tension until wheels lose molding sheen!
DO NOT hang anything on backstrap or it may break!
Safety
In the instruction manual, three ways of drawing special attention are used. These ways are highlighted in the following manner.
Warning!
Risk of personal injury or mechanical fault.
Important!
Risk of mechanical damage or fault.
Note!
Important information to improve handling.
Recycling of products
When recycling, the product’s chassis is separated from other parts. At
separation, the parts can be sorted according to material after unscrewing and
dimantling rivets and other connections. The different parts should be
separated into metal, plastic or combined materials. The products consist
mainly of steel pipe and other metal components. Examples of parts witch
consist of combined materials, are the front fork including bearings wheel
with bearing.
Note!
Different authorities/recycling companies handle recycled materials in
different ways. It is thus fitting when in any doubt over the best way to
proceed when recycling, to contact the relevant governing body.
Environmentally friendly
Human Care HC AB aids are manufactured to have as little effect on the
environment as possible during their lifetime. This allows for the used
product to be dismantled and for its parts to be recycled. Products with
lengthy lifecycles safeguard our sensitive environment and are thus more
environmentally friendly
Human Care HC AB is a part of REPA. REPA – A countrywide system for recycling of packaging.
Areas of use
Carl-Oskar and Rebel are available as trolley walker and RA-rollator. Carl- Oskar and Rebel are stable trolley walker and RA-rollators, which are suitable both for use in-and outdoors. With their flexible chassis, they function well even if ground surfaces are uneven. The tolley walker and RA-rollator have a unique way of folding which allows them to be stored upright whilst folded. They can be folded and unfolded with simply used handles. The trolley walker and RA-rollators are available in two different widths and in two different heights.
Technical Data
**Rollator Art no.*| Min.| Max.| Seat height| Width|
Length| Wheel size| Weight (kg)| L x B x H (Min.)|
Standard (kg)**
---|---|---|---|---|---|---|---|---|---
Carl-Oskar RA-rollator
12315 Low 67 cm| 950| 1130| (640)| 670| 820| 300×45| 13,0| 820x260x950| 125
12325 Nor. 67 cm| 1070| 1260| (640)| 670| 820| 300×45| 13,2| 820x260x1070| 125
12415 Low 72 cm| 950| 1130| (640)| 720| 820| 300×45| 13,1| 820x260x950| 125
12425 Nor. 72 cm| 1070| 1260| (640)| 720| 820| 300×45| 13,3| 820x260x1070| 125
Carl-Oskar Trolley walker
13315 Low 67 cm| 950| 1130| –| 670| 820| 300×45| 14,5| 820x260x960| 125
13325 Nor. 67 cm| 1070| 1260| –| 670| 820| 300×45| 14,7| 820x260x1070| 125
13415 Low 72 cm| 950| 1130| –| 720| 820| 300×45| 14,6| 820x260x950| 125
13425 Nor. 72 cm| 1070| 1260| –| 720| 820| 300×45| 14,8| 820x260x1070| 125
Rebel RA-rollator
22311 Low 67 cm| 860| 1040| (550)| 670| 750| 200×40| 11,3| 750x250x860| 125
22321 Nor. 67 cm| 1040| 1220| (620)| 670| 750| 200×40| 11,5| 750x250x1000| 125
22411 Low 72 cm| 860| 1040| (550)| 720| 750| 200×40| 11,4| 750x250x860| 125
22421 Nor. 72 cm| 1040| 1220| (620)| 720| 750| 200×40| 11,6| 750x250x1000| 125
Rebel Trolley walker
23311 Low 67 cm| 860| 1040| –| 670| 750| 200×40| 12,8| 750x250x860| 125
23321 Nor. 67 cm| 1040| 1220| –| 670| 750| 200×40| 13,0| 750x250x1000| 125
23411 Low 72 cm| 860| 1040| –| 720| 750| 200×40| 12,9| 750x250x860| 125
23421 Nor. 72 cm| 1040| 1220| –| 720| 750| 200×40| 13,1| 750x250x1000| 125
(All measurements in mm)
Mesurements in paranthesis are not standard. RA-rollator Carl-Oskar and Rebel
are delivered as standard without seat.
Accessories
Accessories | Art. nr. | Info |
---|---|---|
Basket with handles | 10601 | Important! Max load 10 kg |
Tray (Only RA-rollator seat cushion) | 10602 | Max load 2kg |
Cane holder | 10603 | |
Oxygen tank holder 1,5 l (Not Rebel low) | 10615 | Max load 5 kg |
Slow down brake | 10620 | |
One-hand brake | 10653 | |
Splash guard (Carl-Oskar) | 10608 | |
Curb climber | 10612 |
See respective assemble instruction.
Table 1. Possible accessory combinations
| Basket| Tray| Cane holder| Oxygen holder| Slow
down brake| One-hand brake| Splash guard| Curb
climber
---|---|---|---|---|---|---|---|---
Basket| | ×| ×| ×| ×| ×| ×| ×
Tray| ×| | ×| ×| ×| ×| ×| ×
Cane holder| ×| ×| | ×| ×| ×| ×| ×
Oxygen holder| ×| ×| ×| | ×| ×| ×| ×
Slow down brake| ×| ×| ×| ×| | ×| | ×
One-hand brake| ×| ×| ×| ×| ×| | ×| ×
Splash guard| ×| ×| ×| ×| | ×| |
Curb climber| ×| ×| ×| ×| ×| ×| |
X = Not applicable.
User guide, Trolley walker
Assembly of cushion
Attach the brackets to the cushion with the belonging screws.
Unfolding
-
Move sidebars outwards.
-
Push gate forward.
-
Lock gate by lowering catch.
-
Position table and tighten wingnut to fasten.
Important!
When tightening wingnut ensure the screw’s thread engages properly in recess.
Folding
To fold the walking table, reverse the unfolding procedure.
Height adjustment
Adjust table to correct height. Loosen wingnut and adjust table to correct
height. Lock wingnut.
Important! The pipes should not be raised above the 0 mark.
Adjust distance to handles
The inner pipe should not be inside the outer pipe.
User guide, RA-rollator
-
Move handles outwards.
-
Push seat forwards.
-
Important! Check that the lock engages the gate.
-
Important! The vertical chromed handle tubes must be mounted in the span between straight back and 45 degrees inwards. They must not be mounted outside this span.
Folding, RA-rollator with seat
-
Pull red loop to free gate
-
Pull seat backwards and move handles inwards.
Unfolding, RA-rollator without seat
Fold catch downwards.
Folding, RA-rollator without seat
Fold catch upwards, pull gate backwards and push handles inwards.
Height adjustment
Loosen wingnut and adjust handgrip to wrist height. Lock wingnut.
Important!
When tightening wingnut ensure the screw’s thread engages properly in recess.
User guide, Trolley walker
- Read all warnings and instructions carefully before using the RA-rollator/TW.
- Ensure that the RA-rollator/TW is properly unfolded before use.
- The RA-rollator/TW may only be used as a support for walking or sitting.
- Never stand on the RA-rollator/TW.
- Do not use the product on stairs or escalators.
- Be extra careful when using the RA-rollator/TW on slopes or uneven surfaces.
- Never sit on the RA-rollator/TW and roll yourself forward with your feet.
- Distribute weight evenly to prevent the RA-rollator/TW from tipping when you sit on it.
- Always set the parking brake before using the RA rollator/TW for support while sitting down or getting up.
- Do not place anything on a folded up RA-rollator/TW when it is in storage or being transported as this may cause damage to it.
- Do not store the RA-rollator/TW close to a heat source as this could cause damage to some details.
- Be careful when you handle the RA-rollator/TW if it has been exposed to abnormally high or low temperatures to avoid injuries.
- Do not store the RA-rollator/TW outdoors.
- Save the user instructions for future use.
Parking brake
Push brake handle downwards to park.
Warning!
Engage parking brake before sitting., only for models with seat.
Brake
Pull brake-handle inwards to brake.
NOTE!
Constant breaking leads to excessive wearing of wheels and brakes.
Brake adjustment
If the brakes are not working properly, adjust the brake cable by screwing
outwards
Cleaning and service
Important!
When changing parts of the rollator, use only Human Care parts to ensure
continued CE validation.
Important!
Do not alter the rollator yourself.
IMPORTANT
Check the rollator regularly to ensure its continued safety to the user.
Regular checks should be carried out as recommended by the instructions
detailed in: Carl-Oskar RA & TW, art. no: 99213 Rebel RA & TW, art. no:
99214 For more information on servicing, reconditioning , spare parts and
accessories, see Human Care’s
website: www.humancaregroup.com or
contact us at the address, phonenumber or e-mail address according to back
page.
Warranty
Human Care HC AB has high demands on our product quality and our warranty
cover material and manufacturing faults of our products. The warranty is not
covering wear and tear on wheel, brakes, handles grips and surface damages
arisen after delivery. The warranty is valid if the product is used in the
intended way and the maintenance instructions have been followed. The product
identity needs to be readable. The product shall not have been modified or
changed in any way after the delivery from Human Care. The warranty time is 1
year if noting else has been stated in contract.
In case of product complaint please contact us for further instructions. The
following information is needed to create a product complaint:
Id number of the product, date for when the last maintenance were performed,
customer contact person and failure description.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>