Schneider Electric HMIDT35X EXtreme Touchscreen User Manual
- June 9, 2024
- Schneider Electric
Table of Contents
- INTRODUCTION
- DANGER
- CAUTION
- Package Contents
- Part Numbers
- Parts Identification
- General Specifications
- Panel Cut Dimensions
- Installation
- Installing to the Panel
- Removing from the Panel
- Wiring
- Precautions
- Replacing the Installation Gasket
- Regular Cleaning
- UKCA, EAC, Chinese RoHS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Schneider Electric HMIDT35X EXtreme Touchscreen ****
INTRODUCTION
This product is an operator terminal used for machines or system automation.
For product usage, you must have detailed information from the Harmony GTUX
User Manual. You can see the manual by scanning the QR code attached to the
product, or from our support site (see below).
|
NOTE:
Electrical equipment should be installed, operated, serviced, and maintained
only by qualified personnel. No responsibility is assumed by Schneider
Electric nor any of its affiliates or subsidiaries (hereinafter, referred to
as Schneider Electric) for any consequences arising out of the use of this
material. If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be impaired
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Remove all power from the device before removing any covers or elements of the system, and prior to installing or removing any accessories, hardware, or cables.
- Unplug the power cable from both this product and the power supply prior to installing or removing the product.
- Always use a properly rated voltage sensing device to confirm power is off where and when indicated.
- Replace and secure all covers or elements of the system before applying power to this product.
- Use only the specified voltage when operating this product.
- Since this product is not equipped with a power switch, be sure to connect a power switch to the power supply.
- Be sure to ground this product’s FG terminal.
Failure to follow these instructions will result in death or serious injury.
POTENTIAL FOR EXPLOSION
- Do not use this product in hazardous environments or locations other than Class I, Division 2, Groups A, B, C, and D.
- Substitution of any component may impair suitability for Class I, Division 2.
- Do not connect or disconnect this product unless power has been switched off or the area is known to be non-hazardous.
- Do not attempt to install, operate, modify, maintain, service, or otherwise alter this product except as permitted in this manual. Unpermitted actions may impair the suitability of this product for Class I, Division 2 operation.
Failure to follow these instructions will result in death or serious injury.
CAUTION
RISK OF BURNING INJURY
- Do not touch the bezel or rear chassis during operation.
- Wear appropriate gloves when operating in ambient temperatures less than 0 °C (32 °F) or greater than 60 °C (140 °F).
Failure to follow these instructions can result in injury or equipment damage.
Package Contents
Please confirm that the following items listed are present. If you find anything damaged or missing, please contact your local distriburor.
-
Harmony GTUX eXtreme Display (HMIDT●5X) x 1
-
Installation gasket (attached to this product) x 1
-
DC power supply connector (right-angle type*1) x 1
-
Quick reference guide (this guide) x 1
*1 Straight type for HMIDT35X
Part Numbers
Harmony GTUX | eXtreme Display | HMIDT35X*1 |
---|
HMIDT65X1
HMIDT75X1
*1 Includes models with additional alphanumeric characters at the end of
the part number
NOTE: These models can be connected to only Harmony
GTUX eXtreme Box (HMIG3X).
Parts Identification
A: Bezel
B: Power plug connector
General Specifications
Rated input voltage | 12…24 Vdc |
---|---|
Input voltage limits | 10.8. 28.8 Vdc |
Power consumption (max including Box Module) | HMIDT35X: 29W |
HMIDT65X: 37W
HMIDT75X: 48W
Ambient air temperature| HMIDT35X: -30…65 °C (-22…149 °F)1 (T4)
HMIDT65X : -30…70 °C (-22…158 °F)1 (T4) HMIDT75X: -20…60 °C (-4…140
°F)*1 (T4)
Ambient air and storage humidity (non condensing, wet bulb temperature 39 °C
[102.2 °F] or less)| 10%…90% RH
Pollution degree| 3 for front face,
2 for other sides
Atmospheric pressure (operating altitude)| 800…1,114 hPa (2,000 m [6,561 ft]
or lower
When installing and wiring
HMIDT35X: -5…65 °C (23…149 °F)
HMIDT65X: -5…70 °C (23…158 °F)
HMIDT75X: -5…60 °C (23…140 °F)
Panel Cut Dimensions
| A| B| C
---|---|---|---
HMIDT35X| 190 mm (+1/-0 mm) (7.48 in [+0.04/-0 in])| 135 mm (+1/-0 mm) (5.31
in [+0.04/-0 in])| 1.6… 5 mm
(0.06…. 0.2 in)
HMIDT65X| 295 mm (+1/-0 mm) (11.61 in [+0.04/-0 in])| 217 mm (+1/-0 mm) (8.54
in [+0.04/-0 in])
HMIDT75X| 394 mm (+1/-0 mm) (15.51 in [+0.04/-0 in])| 250 mm (+1/-0 mm) (9.84
in [+0.04/-0 in])
Installation
Installation Requirement:
This product is designed for use on flat surfaces of IP66F, IP67F, Type 4X
(indoor and outdoor use), Type 12 and Type 13 enclosure. Be aware of the
following when building this product into an end-use product:
- The rear face of this product is not approved as an enclosure. When building this product into an end-use product, be sure to use an enclosure that satisfies standards as the end-use product’s overall enclosure.
- Install this product in an enclosure with mechanical rigidity.
- The front face of this product is designed for indoor and outdoor use, and for use in a wet location. UL certification obtained is for indoor and outdoor use for the front side, and indoor use only for other sides.
- Install and operate this product with its front panel facing outward.
NOTE: IP66F and IP67F are not part of the UL certification.
- Internal temperature
- External temperature
- Power connector
NOTE:
- Metal reinforcing strips may be attached to the inside of the wall, near the panel-cut, to increase its rigidity.
- Even if the installation wall thickness is within the specified range, depending on wall’s material, size, and installation location of this product and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.
- Check that the ambient air temperature and the ambient humidity are within their specified ranges. When installing this product in a cabinet or enclosure, the ambientair temperature is the cabinet’s or enclosure’s internal and external temperature.
- Be sure that heat from surrounding equipment does not cause this product to exceed its standard operating temperature.
- When mounting this product vertically, ensure that the right side of this product faces up. In other words, the DC power connector should be at the top.
- For vertical mounting, make sure your screen editing software supports vertical installation.
- When installing this product in a slanted position, the product face should not incline more than 30°.
- Ensure you have enough space to insert and remove the storage card.
Installing to the Panel
- Anti-drop lock
- Panel
- Installation fastener
- L-shaped part of the Installation fastener
Number of Installation Fasteners
15-inch model: Top – 2, Bottom – 2, Right – 2, Left – 2
12-inch model or smaller: Top – 2, Bottom – 2, Right/Left0
NOTE:
- The necessary torque for installation fasteners is 0.7 N•m (6.2 lb-in).
- If the panel is thick (approximately 5 mm [0.2 in]), you may have trouble straightening the L-shaped part of the installation fastener. If this happens, push the display module from the front as you tighten the screws.
Removing from the Panel
- Rear side
- Panel
- Front side
NOTE: If the panel is thick (approximately 5 mm [0.2 in]), you may have trouble straightening the L-shaped part of the installation fastener. If this happens, push the display module from the front as you loosen the screws.
Wiring
- Make sure the ground wire is either the same or heavier gauge than the power wires.
- Do not use aluminum wires in the power supply power cord.
- To prevent the possibility of a terminal short, use a pin terminal that has an insulating sleeve.
- If the ends of the individual wires are not twisted correctly, the wires may create a short circuit.
- The conductor type is solid or stranded wire.
- Use copper wire rated for 75 °C (167 °F) or higher.
- Use the SELV (Safety Extra-Low Voltage) circuit and LIM (Limited Energy) circuit for DC input.
Power cord diameter | 0.75…2.5 mm2 (18…13 AWG)*1 |
---|---|
Conductor type | Solid or stranded wire |
Conductor length | ![](https://manuals.plus/wp- |
content/uploads/2023/01/Screenshot_2-162.png)
*1 For UL compatibility, use AWG 14 or AWG 13
+ | 12…24 Vdc |
---|---|
– | 0 Vdc |
FG | Grounded terminal connected to the panel chassis. |
-
HMIZGPWS (Straight type for
HMIDT35X) -
HMIZXPWS (Right-angle type
for HMIDT65X/75X) -
DC power cord
-
Opening button
NOTE: Do not solder the wire directly to the power crimp pin.
Precautions
After checking the wiring route carefully, use this product with FG connected
to ground.
Grounding
Functional grounding: Grounding resistance of 100 Ω or less and a wire of 2
mm2 (AWG 14) or thicker, or your country’s applicable standard.
Replacing the Installation Gasket
| Installation gasket
---|---
HMIDT35X| HMIZD53W
HMIDT65X| HMIZD56W
HMIDT75X| HMIZX57W
- Installation gasket
- Protruding point
Regular Cleaning
When this product gets dirty, soak a soft cloth in water with a neutral detergent, wring the cloth tightly and wipe this product.
UKCA, EAC, Chinese RoHS
This information is essential for China RoHS.
Part Name
| Hazardous Substances
---|---
(Pb)| (Hg)| (Cd)| (Cr (VI))| (PBB)| (PBDE)
Metal parts| ○| ○| ○| ○| ○| ○
Plastic parts| ○| ○| ○| ○| ○| ○
Electronic| ×| ○| ○| ○| ○| ○
Contacts| ○| ○| ○| ○| ○| ○
Cables & cabling accessories| ○| ○| ○| ○| ○| ○
This table is made according to SJ/T 11364.
○ : Indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572.
×: Indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572.
UK Representative:
Schneider Electric Limited Stafford Park 5, Telford, TF3 3BL, United Kingdom
Manufacturer:
Schneider Electric Industries SAS 35 rue Joseph Monier, Rueil Malmaison 92500,
France
www.se.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>