SONBUS SM5388V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated Sensor User Guide

June 5, 2024
SONBUS

SONBUS SM5388V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated Sensor

SM5388V using the standard DC0 ~ 5V voltage output signal,easy access to PLCDCS and other instruments or systems for monitoring wind speed,conductivity state quantities.The internal use of high-precision sensing core and related devices to ensure high reliability and excellent long-term stability,can be customized RS232, RS485, CAN, 4-20mA, DC0~5V10V, ZIGBEE, Lora, WIFI, GPRS and other output methods.

Technical Parameters

Technical parameter Parameter value
Brand SONBEST
Wind speed range 0~30m/s
Start wind 0.2m/s
Wind speed accuracy ±3%
Shell material aluminum
Wind direction range 0~360°
Wind direction resolution 22.5°
Output Interface DC0~5V
Power DC12~24V 1A
Running temperature -40~80°C

Product Size

How to wiring?

Application solution

16 – DIMENSIONAL MAP OF WIND DIRECTION

How to use?

  1. wind speed and DC0-5Vvoltage computing relationship
    For example, the range is 0~30m/s, the analog output is 0~5V DC0 -5Vvoltage signal, wind speed and DC0-5Vvoltage The calculation relationship is as shown in the formula: C = (A2 -A1) (X-B1) / (B2-B1) + A1, where A2 is wind speed range upper limit, A1 is the lower limit of the range, B2 is DC0-5Vvoltage output range upper limit, B1 is the lower limit, X is the currently read wind speed value, and C is the calculated DC0-5Vvoltage value. The list of commonly used values is as follows:DC0-5Vvoltage(V)| wind speedValue (m/s)| Calculation Process
    ---|---|---
    0| 0.0| (30-0)
    (0-0)÷(5-0)+0
    1| 6.0| (30-0)(1-0)÷(5-0)+0
    2| 12.0| (30-0)
    (2-0)÷(5-0)+0
    3| 18.0| (30-0)(3-0)÷(5-0)+0
    4| 24.0| (30-0)
    (4-0)÷(5-0)+0
    5| 30.0| (30-0)*(5-0)÷(5-0)+0

As shown in the above formula, when measuring 2.5V, cur rent DC0-5Vvoltage is 15m/s

  1. conductivity and DC0-5Vvoltage computing relationship
    For example, the range is 0~360°, the analog output is 0~5V DC0 -5Vvoltage signal, conductivity and DC0-5Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) (X-B1) / (B2-B1) + A1, where A2 is conductivity range upper limit, A1 is the lower limit of the range, B2 is DC0 -5Vvoltage output range upper limit, B1 is the lower limit, X is the currently read conductivity value, and C is the cal culated DC0-5Vvoltage value. The list of commonly used values is as follows:DC0-5Vvoltage(V)| conductivityValue (°)| Calculation Process
    ---|---|---
    0| 0.0| (360-0)
    (0-0)÷(5-0)+0
    1| 72.0| (360-0)(1-0)÷(5-0)+0
    2| 144.0| (360-0)
    (2-0)÷(5-0)+0
    3| 216.0| (360-0)(3-0)÷(5-0)+0
    4| 288.0| (360-0)
    (4-0)÷(5-0)+0
    5| 360.0| (360-0)*(5-0)÷(5-0)+0

As shown in the above formula, when measuring 2.5V, current DC0 -5Vvoltage is 180°

Disclaimer

This document provides all information about the product, does not grant any license to intell ectual property, does not express or imply, and prohibits any other means of granting any intellectual property rights, such as the statement of sales terms and conditions of this product, other issues. No liability is assumed. Furthermore, our company makes no warranties, express or implied, regarding the sale and use of this product, including the suitability for the specific use of the product, the marketability or the infringement liability for any patent, copyright or other intellectual property rights , etc. Product specifications and product descriptions may be modified at any time without notice.

Contact Us

Company: Shanghai Sonbest Industrial Co., Ltd
Address: Building 8,No.215 North east road,Baoshan District,Shanghai,China
Web: http://www.sonbest.com
Web: http://www.sonbus.com
SKYPE: soobuu
Email: sale@sonbest.com
Tel: 86-021-51083595 / 66862055 / 66862075 / 66861077

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SONBUS User Manuals

Related Manuals