HILTI HIT-HY 200-A V3 Injectable Adhesive Anchors Instruction Manual

June 4, 2024
HILTI

HILTI logo

HIT-HY 200-A V3 Injectable Adhesive Anchors
Instruction Manual

HILTI HIT HY 200 A V3 Injectable Adhesive Anchors

qr.hilti.com/manual/?id=2334935

HIT-HY 200-A V3 Injectable Adhesive Anchors

Hilti HIT-HY 200-A V3
Hilti HIT-HY 200-R V3

|
---|---

WarningHILTI HIT HY 200 A V3 Injectable Adhesive Anchors - icon
2 Contains: hydroxypropyl methacrylate (A) 2,2‘-(m-tolylimino)diethanol (A) 1,4-Butanediol-methacrylate (A) dibenzoyl peroxide (B) May cause an allergic skin reaction. (A, B)  causes serious eye irritation. (B) Very toxic to aquatic life with long-lasting effects. (B)

Hilti HIT-HY 200-A/R V3

The latest version is available online, use the QR code on the front page HILTI HIT HY 200 A V3 Injectable Adhesive Anchors - fig
10

1  Uncracked concrete;
2  Cracked concrete;
3  Grout-filled CMU;
4  Dry base material;
5  Water saturated base material;
6  Waterfilled borehole in concrete;
7 Threaded rod, Threaded sleeve;| 8 Rebar;
9 HIT-Z, HIT-Z-R;
10 Hammer drilling;
11 Hollow drill bit;
12 Diamond coring;
13 Roughening tool;
14 Temperature of base material;| 15 cartridge temperature;
16 Working time;
17 Curing time;
18 Roughening time;
19 Blowing time;
20 ECO mode;
21 Automatic filter cleaning
---|---|---

Hilti HIT-HY 200-A/R V3HILTI HIT HY 200 A V3 Injectable Adhesive
Anchors - fig 9HILTI HIT HY 200 A V3
Injectable Adhesive Anchors - fig 8HILTI HIT HY 200 A V3 Injectable Adhesive Anchors - fig
7HILTI HIT HY 200 A V3 Injectable
Adhesive Anchors - fig 6HILTI HIT HY
200 A V3 Injectable Adhesive Anchors - fig 5HILTI HIT HY 200 A V3 Injectable Adhesive Anchors - fig
4HILTI HIT HY 200 A V3 Injectable
Adhesive Anchors - fig 3HILTI HIT HY
200 A V3 Injectable Adhesive Anchors - fig 2HILTI HIT HY 200 A V3 Injectable Adhesive Anchors - fig
1HILTI HIT HY 200 A V3 Injectable
Adhesive Anchors - fig

Adhesive anchoring system for rebar and anchor fastenings in concrete.

Hilti HIT-HY 200-A/-R V3
Contains: hydroxypropyl methacrylate (A) 2,2‘-(m-tolylimino) diethanol (A) 1,4-Butandioldimethacrylat (A) dibenzoyl peroxide (B)HILTI HIT HY 200 A V3
Injectable Adhesive Anchors - icon 1

  • Warning May cause an allergic skin reaction. (A, B)

  • Causes serious eye irritation. (B)

  • Very toxic to aquatic life with long-lasting effects. (B)

  • Do not get in eyes, on skin or on clothing.

  • Wear eye protection, protective clothing, and protective gloves.

  • IF ON SKIN: Wash with plenty of water.

  • IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

  • If skin irritation or rash occurs: Get medical advice/attention.

  • If eye irritation persists: Get medical advice/attention.

Disposal considerations: Empty packs: Leave the mixer attached and dispose of via the local Green Dot recovery system or EAK waste material code: 150102 plastic packaging Full or partially emptied packs: Must be disposed of as special waste in accordance with official regulations. UK waste material code: 08 04 09 waste adhesives and sealants containing organic solvents or other dangerous substances. or EAK waste material code: 20 01 27 paint, inks, adhesives, and resins containing dangerous substances.
Product Information: Always keep these instructions together with the product even when given to other persons. Material Safety Data Sheet: Review the MSDS before use. Check expiration date: See imprint on foil pack manifold (month/year). Do not use expired products. Foil pack temperature during usage: 0 °C to 40 °C / 32 °F to 104 °F. The base material temperature at the time of installation: HAS-U, HIT-V, HIS, Rebar: between -10 °C and 40 °C / 14 °F and 104 °F.; HIT-Z: between +5°C and 40°C / 41°F and 104°F. Conditions for transport and storage: Keep in a cool, dry, and dark place between 5 °C and 25 °C / 41 °F and 77 °F.
For any application not covered by this document / beyond the values specified, please contact Hilti. Partly used foil packs must remain in the cassette and has to be used within 4 weeks. Leave the mixer attached to the foil pack manifold and store it within the cassette under the recommended storage conditions. If reused, attach a new mixer and discard the initial quantity of anchor adhesive.
Failure to observe these installation instructions, use of non-Hilti anchors, poor or questionable concrete conditions, or unique applications may affect the reliability or performance of the fastenings.
NOTICE
The surface of the HIT-Z anchor rod must not be altered in any way.
The thread of HIT-Z must stay free from dirt and dust during the installation procedure and its cones must be fully embedded into mortar (especially at minimum embedment). Torque moment must always be applied on HIT-Z nut and washer installed above a solid baseplate laying on concrete.
Improper handling may cause mortar splashes.
Always wear safety glasses, gloves, and protective clothes during installation. | Never start dispensing without a mixer properly screwed on. | Attach a new mixer prior to dispensing a new foil pack (ensure a snug fit). | Use only the type of mixer (HIT-RE-M) supplied with the adhesive. Do not modify the mixer in any way. | Never use damaged foil packs and/or damaged or unclean foil pack holders (cassettes).
**Poor load values / potential failure of fastening points due to inadequate borehole cleaning.
Hilti hollow drill bits TE-CD, and TE-YD must be used in conjunction with a properly maintained Hilti vacuum cleaner with model and suction capacity (volumetric flow rate) as specified in the accessory table. | The boreholes must be free of debris, dust, water, ice, oil, grease and other contaminants prior to adhesive injection. | For blowing out the borehole – blow out with oil-free air until the return air stream is free of noticeable dust. | For flushing the borehole – flush with water line pressure until water runs clear. | For
brushing the borehole – only use a specified wire brush. The brush must resist insertion into the borehole – if not the brush is too small and must be replaced. | Important! Remove all water from the borehole and blow out with oil-free compressed air until the borehole is completely dried before mortar injection. | Do not exceed the roughening time when roughening the drilled hole!
Ensure that boreholes are filled from the back of the borehole without forming air voids.
If necessary use the accessories/extensions to reach the back of the borehole. | For overhead applications use the overhead accessories HIT-SZ and take special care when inserting the fastening element. The excess adhesive may be forced out of the borehole. Make sure that no mortar drips onto the installer. | In water-saturated concrete, it is required to set the anchor immediately after cleaning the borehole.
Not adhering to these setting instructions can result in failure of fastening points!**HILTI HIT HY 200 A V3 Injectable Adhesive Anchors -
icon

Made in Germany
Hilti = registered trademark of
Hilti Corporation, Schaan, Liechtenstein
www.hilti.group
© 2022 Right of technical changes reserved S.E. & O