premom EBT-380 Smart Basal Thermometer User Manual
- June 3, 2024
- premom
Table of Contents
- premom EBT-380 Smart Basal Thermometer
- TECHNICAL SPECIFICATIONS
- INTENDED USE
- CONTENTS
- WARNINGS
- PREMIUM APP SYMBOLS
- WARRANTY
- DISCLAIMER
- SETUP AND USE
- HOW DO YOU SWITCH BETWEEN CELSIUS AND FAHRENHEIT?
- DATA STORAGE AND UPLOAD
- CHOOsING MEASUREMENT UNIT ON THE APP
- REMINDER NOTIFICATION SETTINGS
- CHANGING THE BATTERY
- MAINTENANCE & CLEANING
- TROUBLESHOOTING
- EMC/FcC INFORMATION
- COMPLIED STANDARD
- ENVIRONMENTAL CONDITION FOR NORMAL WORKING, TRANSPORT, AND STORAGE
- EXPLANATION OF SYMBOLS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
premom EBT-380 Smart Basal Thermometer
TECHNICAL SPECIFICATIONS
- Product name Smart Basal Thermometer
- Model EBT-380
- Size 2.86 in x 2.24 in x 0.99 in
- Transmission distance. ..30 feet
- Measurement.. 89.60°F-109.38°Furacy… t0.18°F/ 0.10°C (from 95.0°F to 102.2°F/35°C-39°C) #0.36°F/ 0.20°C (from 89.6°F to 95.0°F/ 32°C-35°C, and from 100.40 °F to 109.38° F/ 39°C-42.9°C) .t0.09°F/ #0.05°C (from 95.00°F
- Laboratory accuracy to 102.20°FI 35.00°C-39.00°c) #0.18″F/ +0.10°C (the resting temperature)
- Battery. … CR2032
- Receiver Apple Phone: iPhone 5S+, iOS 11.0+ Android Phone: Android 5.0+
- Operating conditions … . temperature: 41°F to 104°F
- Weight .. Estimated 38g
- Battery Service Life ……. Greater than 400 measurements
- Product Service Life … 5 Years
(Please refer to the box for the production date and batch information)
INTENDED USE
The Smart Basal Thermometer with Blue Tooth function, Model No. EBT-380 is intended for the measurement and monitoring of women’s body temperature at home through Bluetooth (( BLE ) function transfers to the smartphone using the Premium App for the purpose of confirming ovulation.
WHY EBT-380?
- Upon setting up, your data can auto-sync to the free app Premium.
- With your BBT data, Premium does auto-charting for you.
- Premium analyzes your BBT with your other fertility information.
- Premium’s all-in-one platform predicts your best conception chance,
- A large backlit LCD display helps you read results easily.
- The innovative flexible sensor tip makes the BBT measurement process easy.
- Accuracy of 0.09°F for temperature readings.
CONTENTS
- 1 Thermometer
- 1 Manual
- Protective Case
WARNINGS
- Not for use in an OXYGEN RICH ENVIRONMENT.
- Before every use, check the device. Do not use it if it is damaged in any way. The continuous use of a damaged unit may cause injury, improper results, or seriOus danger.
- If you have any problems with this device, such as setting up, maintaining or using, please contact with Premom Customer service.
- Never attempt to open or repair the thermometer.
- The main material of the shell is ABS. Be careful to the potential allergic reactions to these materials.
- Protection against electric shock: Internally powered ME equipment.
- Protection against harmful ingress of water or particulate matter: IP22.
PREMIUM APP SYMBOLS
- Paired with a thermometer and trying to connect now
- Paired with a thermometer and successfully connected
- User Profile/ Slide Menu
- Log BT Temperature Log
WARRANTY
This product is warranted from manufacturing defects for one year from the date of retail purchase. It does not cover damages or wears resulting from an accident, misuse, abuse, commercial use, or theft or an unauthorized adjustment or repair of the product.
DISCLAIMER
This thermometer is not a medical device and is only used for fertility tracking.
SETUP AND USE
Download the app
Simply search “Premium” in the Apple App Store or the Google Play Store to
download and install the app.
Create an account
Open the Premium app and create your account by clicking “Sign up” and
following the instructions on the signup pages.
Note: Completing as much of the information on the Signup Pages will help the app to track your fertility most accurately. These values are important so Premom app can use them to predict your ovulation.
- Date of Your Last Period
- Your Average Period Length
- Your Average Cycle Length
- Your Age
Pairing the thermometer
Keep the thermometer close to your smartphone while the connection is being
established.
- Step 1: Tap on the bottom of the app homepage and choose “Pair”.
- Step 2: Select “Pair immediately” to start the pairing.
- Step 3: Pairing is complete and ready to use.
Taking your temperature
- Step 1: Keep the smart thermometer near your bed. Make sure to take your basal body temperature each morning at the same time for the best results.
- NOTE: Take your measurement upon awakening and before any activities. Any activities will most likely increase your temperature and cause an inaccurate measurement.
- We recommend that you use the BBT lying on your side rather than face up and flat for accuracy.
- Step 2: Upon waking, turn on the smart thermometer. Put the sensor tip in mouth under the tongue and close the lips until you hear 2 short beeps, which indicates the completion of the BBT measurement. usually takes 90 to 120 seconds to complete the measurement.
- Step 3: Your measurement will automatically sync to your smartphone if it is nearby, Bluetooth is enabled, and the app is running in the background. Otherwise, the reading will remain on the queue until next time the thermometer connects to the app.
Note: f the measured temperature is too low (below 89.6°F), no data will be displayed, stored, or uploaded to the app.
HOW DO YOU SWITCH BETWEEN CELSIUS AND FAHRENHEIT?
When the thermometer is off, press and hold the power button for about 7 seconds until you see the switched temperature unit. Release the button for confirmation.
DATA STORAGE AND UPLOAD
Memory stores up to 60 measurements on the device. While the thermometer is off, press down the On / Off button for 3 seconds to review the stored data. You can exit the memory display mode by holding down the On/Off button for3 seconds or it will shut off automatically after 10 seconds. To sync the temperature data to your account, enable Bluetooth on your phone, open the Premium app, and turn on the thermometer. Once the thermometer is connected with the app, all the stored data will automatically sync to the app. A note for IOS users: if the Premium app is running in the background and the Bluetooth is activated, the data will be automatically synced once the device is turned on nearby (normally within 10 feet).
Note: If the temperature data fails to sync to the app, please check the connection status by pressing “Device” under “Settings”. If the status is “not connected,” double check the device is on and Bluetooth is enabled on your phone.
CHOOsING MEASUREMENT UNIT ON THE APP
F is the default unit. You may skip this setting if °F is the right unit for you.
- Step 1: Tapo the top left of the homepage of the Premium app and select “Settings”.
- Step 2: Find the temperature units on the settings list, switch the temperature unit between °C and °F, then turn on the thermometer.
REMINDER NOTIFICATION SETTINGS
Tap on the top left of the homepage,and select “Reminders” in the app. Here you can set reminder notifications for BBT PDG or LH Testing. The Premium app will send you reminders for you to take BBT, PDG, or LH testing.
CHANGING THE BATTERY
Please replace the battery when the low-battery symbol appears on the right of the LCD display. Remove the battery cover and replace it with a battery of the same battery type CR2032. Make sure the “+” sign faces up. Then replace the battery cover. Always dispose of used batteries according to local laws and regulations.
NOTE: To avoid power loss during transportation, the thermometer comes to you with an insulation film between the battery and the metal contact in the battery compartment. Please remove the insulation film for initial use and make sure the battery is in the right place (facing up).
MAINTENANCE & CLEANING
- Clean the flexible sensor tip of the thermometer with a dry doth dampened slightly with 75% rubbing alcohol and 25% water before and after every use.
- Do not use cleaning agents other than alcohol or water to clean the thermometer as it may damage or decrease the lifetime of the product and / or present safety risks.
- Always place the tip of the thermometer back in the plastic cover when not in use.
TROUBLESHOOTING
- Problem: App unable to connect with the device
- Possible Solutions:
- Make sure Bluetooth is enabled on your smart device.
- Replace the battery of the device.
- Log out of the app. Make sure the app is not running in the background and log back in.
- Restart the smartphone if necessary.
- Problem: Unstable body temperature readings
- Possible Solutions: Ensure the thermometer probe is placed firmly underneath your tongue, close your lips, breathe normally and do not speak, eat, drink, or move while testing.
- Problem: Abnormally high BBT
- Possible Solutions: Take measurements immediately after waking up, limit physical activities before and during measurement. Note: If the problem persists, please contact the customer support or consult your doctor if concerned. 9 Please direct all returns to the place of the original receipt, and you may be asked to provide proof of purchase. To get support from our customer service, please contact support at@premom.com
EMC/FcC INFORMATION
- This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment.
- Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
- Caution: This unit has been thoroughly tested and inspected to assure proper performance and operation!
- Caution: this device should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, this device should be observed to verify
normal operation in the configuration in which it will be used.
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures, objects
and people.
- Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and IV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the EBT-380 is used exceeds the applicable RF compliance level above, the EBT-380 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the EBT-380.
- Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distances between portable and mobile RF communications equipment and the EBT-380.
The EBT-380 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. Ihe customer or the user of the EBT-380 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the EBT-380 as recommended below, according to the maximum output power of the communications equipment.
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (w) according to the transmitter manufacturer
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
FCC ID: 2ADNQBTA41CNBT
This device complies with Part 15 of the FCC Rules. Operation is Subject to the following two conditions:
- This device may not cause harmful interference,
- This device must accept any interference received, including interference that may cause undesired operation.
COMPLIED STANDARD
- ISO 10993-5
- ISO10993-10
ENVIRONMENTAL CONDITION FOR NORMAL WORKING, TRANSPORT, AND STORAGE
Working environment:
- Temperature: 41°F-104°F(5°C-40°C)
- Humidity: 15% to 85%RH
- Atmospheric pressure: 86Kpa to 106 Kpa
Transport & storage environment:
- Temperature: -4°F-122° F(-20°C-55° C)
- Humidity: s85%RH
- Atmospheric pressure: 86Kpa to 106 Kpa
EXPLANATION OF SYMBOLS
Get pregnant fast and naturally
NOTE: As we are constantly improving and updating the Premom app to offer the best user experience for our customers, the interface may be different from the illustrations included and all features mentioned should be still available and similar.
Questions or comments?
- Please call toll-free: 1-855-822-6999 M-F 9 a.m.-5 p.m. CST
- E-mail: support@premom.com
- Manufactured for: Easy Healthcare Corporation 360 Shore Dr. Unit B, Burr Ridge, IL 60527 Made in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>