HILTI HIT-HY 270 Adhesive Anchor Instruction Manual

June 3, 2024
HILTI

HILTI-HIT-HY-270-Adhesive-Anchor-logo

HILTI HIT-HY 270 Adhesive Anchor

HILTI-HIT-HY-270-Adhesive-Anchor-product-image

Instruction for use

HILTI-HIT-HY-270-Adhesive-Anchor-28

HILTI-HIT-HY-270-Adhesive-Anchor-29

Warning
Contains:
Methacrylate’s (A), Boric Aside (A), dibenzoyl peroxide (B)
May cause an allergic skin reaction. (A,B) Causes serious eye irritation (A) Harmful to aquatic life with long lasting effects. (A)
Very toxic to aquatic life with long lasting effects. (B)”

Adhesive anchoring system for anchor fastenings in hollow and solid masonry.
Read the safety precautions, safety data sheet, and the product information before use. Read the safety precautions and the product information of the accessories before use.

Hilti HIT-HY 270

HILTI-HIT-HY-270-Adhesive-Anchor-02

HILTI-HIT-HY-270-Adhesive-Anchor-03

HILTI-HIT-HY-270-Adhesive-Anchor-04

HILTI-HIT-HY-270-Adhesive-Anchor-05

  • Paraphing crux

| V [ml]| HILTI-HIT-HY-270-Adhesive-Anchor-07| HILTI-HIT-
HY-270-Adhesive-Anchor-08
---|---|---|---
HILTI-HIT-HY-270-Adhesive-Anchor-06HIT-SC| | HDM| HDE 500
12 x 85| 24| 5| 4
16 x 50| 18| 4| 3
16 x 85| 30| 6| 5
18 x 50| 24| 5| 4
18 x 85| 36| 8| 6
22 x 50| 30| 6| 5
22 x 85| 48| 10| 8

HILTI-HIT-HY-270-Adhesive-Anchor-31

| V [ml]| HILTI-HIT-HY-270-Adhesive-Anchor-07| HILTI-HIT-
HY-270-Adhesive-Anchor-08
---|---|---|---
HILTI-HIT-HY-270-Adhesive-Anchor-06HIT-SC| | HDM| HDE 500
16 x 50 + 16 x 85| 18 + 30| 4 + 6| 3 + 5
16 x 85 + 16 x 85| 30 + 30| 6 + 6| 5 + 5
18 x 50 + 18 x 85| 24 + 36| 5 + 8| 4 + 6
18 x 85 + 18 x 85| 36 + 36| 8 + 8| 6 + 6
22 x 50 + 22 x 85| 30 + 48| 6 + 10| 5 + 8
22 x 85 + 22x 85| 48 + 48| 10 + 10| 8 + 8

HILTI-HIT-HY-270-Adhesive-Anchor-09

| V [ml]| HILTI-HIT-HY-270-Adhesive-Anchor-07| HILTI-HIT-
HY-270-Adhesive-Anchor-08
---|---|---|---
HILTI-HIT-HY-270-Adhesive-Anchor-06HIT-SC| | HDM| HDE 500
16 x 85| 30| 6| 5
18 x 85| 36| 8| 6
22 x 85| 48| 10| 8

HILTI-HIT-HY-270-Adhesive-Anchor-10

HILTI-HIT-HY-270-Adhesive-Anchor-32

HILTI-HIT-HY-270-Adhesive-Anchor-13

HILTI-HIT-HY-270-Adhesive-Anchor-15

HILTI-HIT-HY-270-Adhesive-Anchor-16

HILTI-HIT-HY-270-Adhesive-Anchor-17

HILTI-HIT-HY-270-Adhesive-Anchor-18

HILTI-HIT-HY-270-Adhesive-Anchor-19

HILTI-HIT-HY-270-Adhesive-Anchor-20

HILTI-HIT-HY-270-Adhesive-Anchor-22

HILTI-HIT-HY-270-Adhesive-Anchor-23

HILTI-HIT-HY-270-Adhesive-Anchor-24

HILTI-HIT-HY-270-Adhesive-Anchor-25

HILTI-HIT-HY-270-Adhesive-Anchor-26

Adhesive anchoring system for anchor fastenings

Adhesive anchoring system for anchor fastenings in hollow and solid clay brick, sand-lime block, concrete, concrete block, aerated concrete and natural stone.

Hilti HIT-HY 270
Contains: methacrylate’s (A), boric acid (A), dibenzoyl peroxide (B )HILTI-HIT-HY-270-Adhesive-Anchor-27

Warning

  • H317 May cause an allergic skin reaction. (A,B)

  • H319 Causes serious eye irritation. (A)

  • H410 Very toxic to aquatic life with long lasting effects. (B)

  • H412 Harmful to aquatic life with long lasting effects. (A)

  • P262 Do not get in eyes, on skin, or on clothing.

  • P280 Wear protective gloves/protective clothing/eye protection/face protection.

  • P302+P352 IF ON SKIN: Wash with plenty of soap and water.

  • P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes.
    Remove contact lenses, if present and easy to do. Continue rinsing.

  • P333+P313 If skin irritation or rash occurs: Get medical advice/attention.

  • P337+P313 If eye irritation persists: Get medical advice/attention.

Disposal considerations

Empty packs
  • Leave the mixer attached and dispose of via the local Green Dot recovery system or EAK waste material code: 150102 plastic packaging

Full or partially emptied packs:

  • Must be disposed of as special waste in accordance with official regulations.
    EAK waste material code: 08 04 09 waste adhesives and sealants containing organic solvents or other dangerous substances. or EAK waste material code: 20 01 27 paint, inks, adhesives and resins containing  dangerous substances.
    Content: 330 ml / 11.1 fl.oz. 500 ml / 16.9 fl. oz
    Weight: 540 g/19.0 oz 820 g/28.9 oz

Hilti accepts no liability for damage or failure caused by:

  • Storage and transport not in accordance with the specified conditions.
  • Failure to observe the instructions for use and setting data, incorrect use
  • Inadequate design of the anchor points, inadequate load bearing capacity of the base material
  • Other influences of which Hilti is not aware or on which Hilti has no influence, e. g. use with products from a third party.

Product Information

  • Always keep these instructions together with the product even when given to other persons.

  • Check expiration date: See imprint on foil pack manifold (month/year). Do not use expired product.

  • Foil pack temperature during usage: between +5 °C and 40 °C / 41 °F and 104 °F.

  • Base material temperature at time of installation: between –5 °C and 40 °C / 23 °F and 104 °F.
    Exception in solid clay brick: between +5 °C and 40 °C / 41 °F and 104 °F.

  • Conditions for transport and storage: Keep in a cool, dry and dark place between 5 °C and 25 °C / 41 °F and 77 °F.

  • For any application not covered by this document / beyond values specified, please contact Hilti.

  • Partly used foil packs must remain in the cassette and has to be used within 4 weeks. Leave the mixer attached on the foil pack manifold and store within the cassette under the recommended storage conditions. If reused, attach a new mixer and discard the initial quantity of anchor adhesive.

NOTICE
Improper handling may cause mortar splashes.

  • Always wear safety glasses, gloves and protective clothes during installation.
  • Never start dispensing without a mixer properly screwed on.
  • Attach a new mixer prior to dispensing a new foil pack (ensure snug fit).
  • Use only the type of mixer (HIT-RE-M) supplied with the adhesive. Do not modify the mixer in any way.
  • Never use damaged foil packs and/or damaged or unclean foil pack holders (cassettes).

Poor load values / potential failure of fastening points due to inadequate borehole cleaning and setting.

  • The boreholes must be free of debris, dust, water, ice, oil, grease and other contaminants prior to adhesive injection.
  • For blowing out the borehole – blow out with oil free air until return air stream is free of noticeable dust.
  • For brushing the borehole – only use specified steel wire brush. The brush must resist insertion into the borehole – if not the brush is too small and must be replaced.
  • If no significant resistance is felt over the entire depth of the hole when drilling (e.g. in unfilled butt joints), the anchor should not be set at this position

Borehole filling in solid masonry and concrete:
Ensure that boreholes are filled from the back of the borehole without forming air voids. If necessary use the accessories / extensions to reach the back of the borehole. HIT-SC is used in the event of drilling into a cavity

For overhead applications use the overhead accessories HIT-SZ and take special care when inserting the fastening element. Excess adhesive may be forced out of the borehole. Make sure that no mortar drips onto the installer.

Borehole filling in hollow masonry:
Use HIT-SC mesh sleeve. Fill the mesh sleeve with mortar from the centering cap until mortar escapes at the centering cap (filling control).

Note: Hilti HIT-HY 270 is not tested for use with climbing anchors.
Applications of this kind are carried out at the user’s own risk.

Not adhering to these setting instructions can result in failure of fastening points!

GB Hilti (Gt. Britain) Ltd.

  • 1 Trafford Wharf Road
  • Trafford Park
  • GB-M17 1BY Manchester
  • Tel +44 161 886 1000

21 Hilti AG
FL-9494 Schaan

Hilti Werke
2873-CPR-201-7

ETA-13/1036
Notified body 2873

ETAG 029
www.hilti.group

www.hilti.group Made in Germany
Hilti = registered trademark of Hilti Corporation, Schaan, Liechtenstein © 2021