AQUALUNG AL50 Underwater Pressure Gauge User Guide
- June 3, 2024
- AQUALUNG
Table of Contents
AQUALUNG AL50 Underwater Pressure Gauge User Guide
CERTIFICATION
Manufacturer: Aqualung La spirotechnique,
1 ere Avenue 14eme Rue, BP148,
06513 Carros Cedex, France
The manufacturer of this underwater pressure gauge is Aqua Lung, 1ere Avenue,
14erne Rue, Bp148, 06513 Carros CEDEX, France. The UK importer is Aqualung UK
Distribution, Neptune Way, Blackburn, Lancashire, England. BB1 2BT.
This underwater pressure gauge has been awarded an examination certificate
from the following notified and approved bodies:
INPP, Port de la Pointe Rouge Entrée n°3, BP157 Marseille CEDEX 08. Notified
body 0078 and SGS UK Ltd, Inward Way, Rossmore Business Park, Ellesmere Port,
Cheshire. CH65 3EN. Approved Body 0120
This product is compliant with European standard & Designated standard
EN250:2014 (NS152111 / N5152112), EN13949:2003 (NS152113 / NS152114), with
European Regulation (EU) 2016/425 and Regulation 2016/425 Personal Protective
Equipment as brought into UK law and amended.
This underwater pressure gauge is a sub-assembly of a self-contained
underwater breathing apparatus and is a category III Personal Protective
Equipment that protects EU and UK declarations of conformity can be consulted
on the website: www.aqualung.com
The EU declarations of conformity can be consulted at www.aqualung.com.
This pressure gauge is a pressure indicator that is a sub-assembly of a self- contained underwater breathing apparatus and is classified as category Ill personal protection equipment. In accordance with Appendix I of EU Regulation 2016/425, this equipment is designed to protect against the risk of “substances and mixtures that constitute a health hazard”.
Models:
Reference| Description| Hose length| Conformity with
standard| Use
---|---|---|---|---
N5152111| AL50 Air underwater pressure gauge| 80 cm| EN250:2014| Air only
N5152112| Pack of 6 AL50 Air underwater pressure gauges| 80 cm| EN250:2014|
Air only
NS152113| AL50 Nitrox 02 underwater pressure gauge Long hose| 80 cm|
EN13949:2003| Nitrox/02 only
NS152114| ALSO Nitrox 02 underwater pressure gauge Short hose| 18 cm|
EN13949:2003| Nitrox/02 only
USE
This underwater pressure gauge is a safety device which shows the residual pressure of the cylinder during a dive. It is a component of open-circuit scuba unit that connects directly to the pressure reducer (first stage of a regulator). It consists of a nickel-plated brass casing, a luminescent photo dial with a reserve indicator, a polycarbonate anti-glare observation port, an elastomer dial protector, a thermoplastic high-pressure hose with a standard connection at a pitch of 7/16 UNF in accordance with ISO 263 to connect it to the pressure reducer. It also includes an overpressure capsule in the event of breakage of the inner Bourdon tube. This pressure relief capsule is a black pad located at the back of the pressure gauge.
Operating temperature
- Operating range: -20°C to 50°C in air
This pressure gauge may be immersed in water at less than 10°C.
Supply pressure
Maximum operating pressure: 300 bar In accordance with EN250, the dial has a measurement range of 0 to 360 bar, i.e. 20% above the maximum operating pressure.
Oxygen compatibility
Models N5152113 and N5152114 are oxygen compatible. They must be connected to
a Ni-trox or oxygen regulator in accordance with EN 13949 2003. These gauges
are identifiable by a green dial protector.
N5152111 or N5152112 models are for use with air only. These gauges are
identifiable by a black dial protector.
USING THE AL 50 UNDERWATER PRESSURE GAUGE
Connecting to the regulator
Aqualung recommends that the pressure gauge should be fitted on your regulator by your Aqualung consultant. If this is not possible, proceed as follows:
- Locate the high pressure outlet of your regulator (see the user manual of the regulator). This is generally identified by the letters HR
- Unscrew the outlet cap of the regulator.
- Remove the cap from the HP hose thread.
- Screw the hose fully into the high pressure outlet of the regulator. Then tighten the hose moderately (tightening torque 5 to 10 N.m).
- Slowly pressurise the regulator to the maximum operating pressure and check that no leaks appear at the connection between the hose and the regulator.
- Remove the window protection film to make it easier to read
Operation with an air regulator
The NS152111 or NS152112 models are special pressure gauges for use in air and
are identifiable by a black pressure gauge protector. The air quality you must
use to pressurise your cylinder must at least comply with EN 12021 2014.
These models are CE certified for use at a maximum depth of 50 metres. For
this purpose and in accordance with EN250, they have been designed and tested
to withstand an ambient pressure equivalent to a depth of 100 metres.
Use with a Nitrox or oxygen regulator
The N5152114 (522010) and NS152113 (522015) models are special pressure gauges for use with Nitrox or oxygen. They are identifiable by a green gauge protector. The maximum operating depth and the maximum exposure time depend on the oxygen content of the mixture;
WARNING: the use of nitrox or oxygen equipment requires some precautions. In particular, you should:
- Obtain Nitrox diver training from a recognised body before using this equipment.
- Use your equipment only with Nitrox and oxygen in accordance with EN12021:2014. Air can contaminate your equipment even if it complies with EN12021.
- Always clean your equipment after use. If your equipment is contaminated, it may self-ignite in the presence of a high percentage of oxygen.
- If your pressure gauge has been in contact with oil, such as compressor oil, you can no longer use this equipment. The design of this HP hose with its flow restrictor makes it impossible to decontaminate it, regardless of the cleaning method used.
- Always pressurise your regulator gradually, slowly opening the storage valve. This is to avoid the risk of ignition due to the presence of oxygen.
Checks before diving
You must always check that your equipment is working properly. Pressurise the regulator by slowly opening the cylinder storage valve to prevent a “pres-sure surge”effect if the HP hose is pressurised too quickly. Check that the pressure shown corresponds to the assumed pressure in the cylinder and that it is compatible with your planned dive profile. Close the valve retention and bleed the regulator. Make sure that the pressure gauge needle returns to zero.
During diving
Regularly check the pressure shown on your pressure gauge. The hose is long enough for you to secure the dial of the pressure gauge in front of you so that you can check the pressure more easily. The pressure gauge dial has a red reserve area between 0 and 50 bar. When the needle reaches this area, it is imperative to return to the surface in accordance with the selected decompression procedure. Like any measuring instrument a pressure gauge is a fragile instrument, so do not remove the elastomer cover that surrounds the dial and protects it from impacts.
Limitations for use
The pressure gauge must not be used under conditions which hinder its use,
e.g. low or non-existent visibility that makes it impossible to read the dial.
You must end your dive if you cannot read the dial due to lack of visibility.
Do not use this pressure gauge if you can see through the dial that water or
humidity has entered it. Do not use this pressure gauge if the needle is not
at zero when it is not pressurised. Do not use this pressure gauge if the HP
hose shows signs of wear, leaks or if the outer sheath is damaged.
STORAGE
- After use, rinse the pressure gauge with clean water.
- Never clean the pressure gauge with a detergent that may damage the screen window.
- Leave the pressure gauge to dry in the open air. Store the pressure gauge with the regulator in a dry place away from heat and sunlight. Storage temperature: -30°C min to +70°C max.
- Avoid disassembling the pressure gauge of the regulator.
- After each dive, if applicable, remember to replace the protective caps on the threads of the hose and the regulator to avoid any risk of contamination.
REGULAR MAINTENANCE
After each dive, rinse this pressure gauge with fresh water only. Do not use
chemicals that could damage the window or the hose to clean this pressure
gauge.
Ensure that your pressure gauge is serviced at least once a year by your
Aqualung consulting specialist to replace the 0-rings on the rotating axis of
the connection between the hose and the pressure gauge capsule and to check
the accuracy of the pressure gauge. Spare parts must be replaced with original
Aqualung parts. Also ensure that this pressure gauge is serviced if it has
been exposed to an abnormal mechanical impact.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>