VAISALA viewLinc Continuous Monitoring System Instructions

September 15, 2024
VAISALA

VAISALA viewLinc Continuous Monitoring System

Specifications

  • Product Name: VaiNet Long-range Wireless Monitoring System
  • Components: RFL100 Data loggers, AP10 Access Point PoE / DC
  • Power, Temperature probe (1 or 2 channels), Chamber, viewLinc SERVER SOFTWARE
  • Features: Power over Ethernet, Multi-port Ethernet, Transmitters, Modbus TCP & RTU support, Standard Wi-Fi Adaptor
  • Wireless Connectivity: IEEE 802.11a/b/g/n

Product Usage Instructions

Setting up the VaiNet Long-range Wireless Monitoring System:

Follow these steps to set up the monitoring system

  1. Place the AP10 Access Point in a central location for optimal wireless coverage.
  2. Connect the RFL100 Data loggers to the Temperature probe and place them in the desired monitoring locations within the Chamber.
  3. Install the viewLinc SERVER SOFTWARE on your designated computer.

Power over Ethernet (PoE) Configuration
To configure Power over Ethernet settings

  1. Connect the VDL200 PoE data logger to the Chamber for power and data transmission.
  2. Use the vNet (Ethernet interface) with DL data logger for Temperature readings.

Multi-port Ethernet Setup:
For setting up Multi-port Ethernet:

  1. Connect the PoE Ethernet Converter to the Switch or Router.
  2. Integrate the VDL200 PoE data logger with the Chamber for monitoring.

Transmitters Integration
To connect Transmitters
Use a Vaisala Indigo host device to connect various probes for measuring CO, Vaporized H2O, humidity, and temperature.

Modbus TCP & RTU Configuration:
To configure Modbus TCP & RTU:

  1. Integrate third-party Modbus TCP devices with the viewLinc SERVER SOFTWARE.
  2. Utilize the Indigo500 Host Device for Modbus RTU connections via Serial Server or Ethernet Interface.

Standard Wi-Fi Adaptor Usage
To use the Standard Wi-Fi Adaptor

  1. Connect Temperature Data loggers and probes to the Chamber with Wireless Ethernet Interface IEEE 802.11a/b/g/n support.

Frequently Asked Questions (FAQ):
Q: Can I connect multiple Temperature probes to a single Data  logger?
A: Yes, some models support multiple channels for connecting more than one Temperature probe to a single Data logger.

VaiNet Long-range Wireless Monitoring

VaiNet Features

  • Vaisala’s proprietary wireless solution based on LoRa® long range radio frequency technology

  • Local Display and Alarming
    Replaceable smart probes for simple install and calibration

  • Battery powered (standard AA alkaline or lithium)

  • Parameters: Temperature only (up to 2 channels), temperature and relative humidity, carbon dioxide %, or one channel for each , T, RH)

  • IP54 enclosure

  • Typical indoor range 100 m (328 ft.)

Power over Ethernet

Device options

  • Other parameters, e.g., Differential Pressure
  • Particle Monitoring, etc. to DL4000

Universal Input Data Logger

  • 4-20mA, 0-5V, 0-10V
  • Alarm contacts via DL1400

Multi-port Ethernet

Transmitters

Connect a variety of probes to viewLinc through a Vaisala Indigo host device to measure CO˜, Vaporized H˜O˜, humidity, temperature, and more.

Modbus TCP & RTU

Standard Wi-Fi Adaptor

Ref. B211150EN-J ©Vaisala 2024

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals