Hisky Scs DKU8X8V2 Dynamic Terminal KU 8X8 V2 Installation Guide
- June 4, 2024
- Hisky Scs
Table of Contents
Hisky Scs DKU8X8V2 Dynamic Terminal KU 8X8 V2
- Document P/N: QSIG0003
- Document Version: V.3
- Creation Data: February 2022
- Last update: April 1st, 2022
Proprietary Notice This document is the proprietary property of hiSky Ltd.
Copying or otherwise distributing the information contained herein is a breach
of confidentiality agreement and subject to legal action.
Introduction
The Quick Start Guide provides basic information for installation,
identification of connectors and visual indicators, as well as regulatory
information for the hiSky IoT Dynamic Ku V2 Terminal.
Product Description
The IoT Dynamic Ku 8X8 V2 Terminal is a compact form-factor device that
enables on-the-move satellite connectivity to sensors/smartphones / IoT
gateways. The terminal includes an innovative modem and phased array antennas
with WI-FI / Bluetooth and Ethernet for user device interfaces. The terminal
supports IoT data transmission such as fleet management data, environment
conditions, alarm events, sensors loggers, operations, and much more, as well
as command and control of sensors and remote systems.
Related Documents
For information about related documents please navigate to
https://www.hiskysat.com. hiSky strives to produce documentation that is
technically accurate and easy to use. hiSky welcomes feedback. Send comments
to support@hiskysat.com.
Getting Help
For answers to questions or for more information, contact hiSky support at
support@hiskysat.com.
Terminal Overview
WARNING: Do not open the terminal or make any changes to the terminal
construction. An opening may expose personnel to dangerous voltages or other
hazards. There are no user-serviceable parts inside. Avoid placing the
Terminal near open flames or any high heat.
Part | Description |
---|---|
Status LED | Off: Powered off |
Slow Flashing green: Searching for satellite (terminal initialization or
tracking lost ).
Fast Flashing green: registration process
Solid Green: Service available (terminal locked/track and registered).
Flashing Blue (every burst): Terminal transmit (toggle every half- second for
250 mil).
Flashing red: No service due to registration problem
Red: Power up / Failure
Solid Blue: Recovery Mode
Connector| Circular connector 19 pin:
DC, Ethernet, Serial – 232/485, Wake up I/O
The terminal kit contains the following items: IoT Dynamic Ku 8X8 V2 Terminal, and this Quick Start Guide. The kit does not include a bracket, screws, cables, or any other mechanical parts for the installation.
Power Supply
Obtain the power cable from your supplier. Refer to the information in the
“Power and Data
Cable” section of this document for information about the power and data cable
pinouts.
Only power up the system with one of the following options:
- AC to DC power supply – 12-24V, 48W DC jack 2.5X5.5MM.
- DC to AC inverter connected from the vehicle to AC to DC power supply.
- DC cable connected from a vehicle directly to the system 12V DC jack 2.5X5.5MM
WARNING: Both the power supply and the inverter must be certified for
safety, electromagnetic compatibility, and all the regulations in the region
where the terminal will operate.
Follow all safety instructions according to the manufacturer of the power
supply and inverter.
A qualified technician should examine the risk of electrical shock and energy
hazard of power supply and inverter failures according to manufacturer
instructions.
Overview of First Run Operation with the hiSky 360 App
-
Initial Login:
- Confirm Internet connectivity to your smartphone for the initial Login and software download steps.
- Download the hiSky App from iPhone App Store or Android Google Play Store.
- Click on the hiSky360 App icon.
- Click LOGIN on the main screen.
- Add the account credentials (username and password) related to your hiSky360 account.
- Choose the NMS connection and tap LOGIN.
-
Software Update:
-
On the main hiSky360 App screen, click on Software Update.
-
Click Ok to continue with the software update process.
-
Click on MANAGE UPDATES.
-
Click on CHECK FOR UPDATES FROM NMS.
-
Select the latest Ku software version for your terminal.
-
Download the software files to your mobile app.
-
Ensure the terminal’s mounting side is facing down and connect the terminal to a power source.
-
Connect your smartphone to the terminal WI-FI access point. The default SSID is the terminal serial number + the characters WF (for example 2970000000001WF). The default password is admin123.
-
Wait for the application to attach to the terminal software. The status will initially show “Attempting”. Wait until it shows “Connected” before proceeding with the upgrade.
-
On the main hiSky App screen, click on SOFTWARE UPDATE.
-
Click on INSTALL UPDATE.
-
At the end of the update, the terminal will reboot.
-
-
Choose Satellite Parameters
- Connect your smartphone to the terminal WI-FI access point.
- Click on the GPS CONFIG on the hiSky main screen.
- Click on REFRESH and SAVE the location parameters.
- Return to the main screen and click on TERMINAL CONFIG.
- In the Satellite Parameters section, ensure that the correct beam number is being used. If not, select the relevant beam number.
- Click SAVE.
- Restart the terminal by pushing the power button. Ensure that the terminal’s mounting side is up before restarting the terminal.
- Use the TERMINAL CONFIG button to integrate between the terminal and the User Device.
-
Active the service plan
- Connect your smartphone to the terminal’s WI-FI access point.
- Login to the hiSky App via a terminal connection.
- On the main hiSky 360 App screen, click on Plan Details.
- Click the ACTIVE PLAN button and wait for confirmation.
-
Connect the Satellite and the Terminal
To establish connectivity between the satellite and the terminal, do the following:- Place the terminal on level ground or tripod mount.
- Place the terminal in a clear line of sight between the terminal and the satellite. Any buildings, trees, people, or other objects in the path may interfere with connectivity.
- Wait for the status LED to turn solid green.
-
Install the Terminal:
WARNING: Improper installation can lead to the device falling causing serious personal injury or damage to equipment. The selected mounting solution must meet the local standard requirements.
The installer is responsible to make sure the installation will meet usage guidelines.
WARNING: Radio frequency hazard – keep a distance of at least 25 cm during terminal operation.
Mobile/On the move Installation:
Terminal installation on a vehicle uses custom-made magnets or other mounting solutions, depending on the vehicle. For the most suitable solution, please contact your provider.
WARNING: The metal surface must be clean and straight, and all magnets should be firmly attached to the metal before driving. Before a drive, secure the power cable. Avoid driving fast on bumpy roads and in dangerous curves.
Fixed or Tripod Installation
Use the mounting interfaces described below, using at least the six M6 VESA 100X100 screws.- ¼ Thread – Standard Tripod Mount.
- 100*100 VESA mount M6 Threads.
Troubleshooting
Issue | Workaround |
---|
WI-FI connection cannot be established between the smartphone and the
terminal.| Make sure a WI-FI connection is available on the smartphone. Check
for relevant integration instructions
Terminal cannot establish satellite connectivity (Slow Flashing Green).| Check
the service plan status in the hiSky mobile app.
Unsuccessful registration to hiSky mobile app.| Internet connection is
required for the initial Login.
LED is Flashing red| No service due to registration problem- Ensure initial
registration to hiSky network and plan activation.
IoT Dynamic Ku 8X8 V2 Terminal Specifications
Parameter | Value |
---|---|
Antenna Gain Rx & Tx@90°> | 21dBi |
Antenna Gain Rx & Tx@30°> | 18dBi |
Noise figure | 2.5dB |
Mechanical Dimensions | H / W / D: 291 / 187 / 42 mm |
Weight | 2.3Kg |
Voltage range: | 12-24 VDC |
Sleep power consumption | 10mW |
Idle power consumption | 10W |
Receive only power consumption | 24W |
Max power consumption | 48W |
Operational Temperature | -20°C to 60°C / / -4°F to +131°F |
Dust and water ingress | IP67 |
Interfaces | Circular connector 19 pin |
DC, Ethernet, serial- 233,422, Wake up I/O
Transmit Antenna Frequency Range| 13.75 GHz – 14.50 GHz
Receive Antenna Frequency Range| 10.7 GHz – 12.75 GHz
GPS Frequency Range| 1560MHz – 1610MHz
WLAN 2.4GHz Frequency Range| 2412MHz – 2462MHz
Bluetooth Frequency Range| 2402MHz – 2480MHz
MODEM Data Rate| 6Kbps to 120Mbps
Danger/Warning Symbol
WARNING: This symbol means danger! You are in a situation that could
cause bodily injury. Before you work on any equipment, be aware of the hazards
involved with electrical circuitry and be familiar with standard practices for
preventing accidents.
Lightning Activity Warning
WARNING: Do not work on the system or connect or disconnect cables during
periods of lightning activity.
Operating Temperature and Airflow Warning
WARNING: To prevent the unit from overheating, do not operate it in an
area that exceeds the maximum recommended ambient temperature as defined in
the Mechanical and Environmental Specifications table. To prevent airflow
restrictions, allow approximately 6 inches (15.2 cm), or adequate space, for
clearance around the external heat sink fins.
Installation Warning
WARNING: Read the installation instructions before connecting the system
to the power source.
Power Supply Circuit Warning
WARNING: Care must be given to connecting units to the supply circuit so
that wiring is not overloaded.
Agency Compliance
For detailed information on standards, see https://www.hiskysat.com/Product
Documentation.
FCC Compliance
Part 15 Compliance
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to 47CFR Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. The equipment uses, generates, and radiates
radiofrequency energy. If the equipment is not installed and used by the
instructions, it may cause harmful interference to radio communications. There
is also no guarantee that interference will not occur in a particular
installation. To determine if the equipment is interfering with radio or
television reception, remove or apply power to the equipment and see if the
interference goes away, or returns, when the unit is off or on.
To meet FCC requirements, only peripherals, such as computer input/output
devices, terminals, and printers certified to comply with the Class B limits,
may be attached to this device. Operation with non-certified peripherals is
likely to result in interference to radio and TV reception.
To meet FCC requirements, shielded cables are required to connect the device
to a personal computer, peripheral, or other Class B certified device.
WARNING: Modification of this equipment without written authorization from hiSky may result in this equipment no longer complying with FCC requirements for Class B digital devices. In that event, the rights to use the equipment may be limited by FCC regulations, and the user may be required to correct any interference to radio or television communications at their own expense.
Safety
TUV Rheinland of North America is a Nationally Recognized Testing Laboratory
(NRTL) in the United States and is accredited by the Standards Council of
Canada to test and certify products to Canadian National Standards. The
Dynamic Terminal Ku 8X8 V2 complies with both U.S. and Canadian National
Standards on Safety.
In addition, the Dynamic Terminal Ku 8X8 V2 complies with EU National
Standards on Safety.
Compliance with RoHS Directive
Details can be found on the hiSky Web site located at
https://www.hiskysat.com/Product Documentation.
Compliance with WEEE Directive
When hiSky products have reached the end of their useful life, hiSky
distributors will be responsible for making provisions for the treatment of
such WEEE using authorized approved treatment facilities.
Please contact the distributor directly.
Canadian Labeling Requirements
The Dynamic Terminal Ku 8X8 V2 complies with Class B of Canadian ICES-003
regulations. CAN ICES-3 B/NMB-3B.
Le IoT Dynamic Terminal Ku 8X8 V2 est conforme à la classe B de la
réglementation canadienne ICES-003.CAN ICES-3 B/NMB-3B.
CE Compliance (European Union)
hiSky declares that the radio equipment type Dynamic Terminal Kau 8X8 V2 is in
compliance with Directive 2014/53/ EU. The full text of the EU declaration of
conformity is available at https://www.hiskysat.com/Product Documentation.