1HVAC PHP Series Inverter Heat Pump For Swimming Pools Owner’s Manual
- September 9, 2024
- 1HVAC
Table of Contents
PHP Series Inverter Heat Pump For Swimming Pools
“`html
Specifications:
Model| Voltage| Frequency/Phase| Design Pressure (High)| Design Pressure
(Low)| Refrigerant (R410A) oz| Net Weight Kgs| Water Circulation Flow L/min|
Noise at 10 Feet dB(A)| Waterproof Class
---|---|---|---|---|---|---|---|---|---
PHP-50| 208-230V| 60Hz/1Ph| 609 PSIG| 261 PSIG| 1.6-10.2| 38.8| 52| 83-117|
IPX4
Product Usage Instructions:
I. Application:
-
Efficiently set swimming pool water temperature for comfort and
pleasure. -
Choose the model based on technical parameters provided.
II. Features:
-
Sensitive and accurate temperature control with water
temperature display. -
High-pressure and low-pressure protection.
-
Protection against low or no water flow.
-
Auto stop protection for excessively low temperatures.
-
Compulsory defrosting for temperature control.
-
Utilizes international brand compressor.
-
Equipped with a high-efficiency titanium heat exchanger.
-
Easy installation and operation.
III. Technical Parameter:
IV. Dimension:
V. Installation Instruction:
-
Detailed drawing for water pipes connection (for
reference). -
Electric wiring diagram with grounding instructions.
-
Installation and requirements must be handled by a pool
professional to avoid damage or safety risks.
FAQ:
Q: Can the swimming pool heater be installed by end users?
A: No, the swimming pool heater must be installed by a pool
professional to prevent damage to the heater or safety risks to the
user. Installation guidelines may vary based on regulations and can
include HVAC technicians or electricians.
“` [pdfjs-viewer url=”/m/aa2e625e563f23b3cc41db0b2ee8da38abca252d8ea8d5d4398037ad8657802c_optim.pdf” viewer_width=100% viewer_height=800px fullscreen=true download=true print=true]
PHP-50 / PHP-65 / PHP-90 / PHP-110 / PHP-140 Inverter Heat Pump for Swimming
Pools
Please read the manual in real time
Content
I. Application …………………………………………………………………………………. 3 II.
Features…………………………………………………………………………………….. 3 III. Technical Parameter
………………………………………………………………….. 4 IV. Dimension………………………………………………………………………………….. 5
V. Installation instruction ………………………………………………………………… 6 VI. Operation
instruction………………………………………………………………… 10 VII. Advanced
application……………………………………………………………….. 13 VIII. Timer
……………………………………………………………………………………….. 16 a) Timer on
setting………………………………………………………………………. 17 b) Timer off
setting………………………………………………………………………. 18 IX.
Testing……………………………………………………………………………………… 19 X. Precautions
……………………………………………………………………………… 20 XI.
Maintenance…………………………………………………………………………….. 21 XII. Trouble shooting for common
faults …………………………………………. 22 XIII. Wi-Fi Setting……………………………………………………………………………..
24 XIV. Warranty & After-Service………………………………………………………….. 33
1
Special Attention:
A. This product is only for swimming pool water heating applications and can’t
be used for the heating for any other liquid materials. B. The inlet and
outlet water nozzles can’t bear the weight of external pipes. C. The main
power switch should be out of the reach of children. D. Make sure the power is
switched off before opening the case of the product. This appliance is not
intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
NOTE:
A. The swimming pool heat pump must be installed by a qualified electrician.
These regulations may change depending on the Country, Province or State you
live in. B. To maximize your swimming comfort, set proper heating temperature.
The recommended heating temperature is 85’F. The unit can work above and below
this recommendation up to a specific capacity depending on operating
conditions. Please contact support for more information. C. Don’t put
obstacles near the air inlet and outlet of the heat pump. D. This heat pump
has power-off memory function. E. When the ambient temperature is below 3’C,
make sure to switch off the main power, and drain off the water from heat
exchanger. F. Never place your hand or any other object in the air inlet or
outlet of the heat pump. G. If any abnormal circumstances discovered, ex:
abnormal noise, smells, smokes and leakage of electricity, switch the main
power off immediately and contact your local dealer/installer or supprt
directly. Do not try to repair the heat pump yourself.
2
I. Application
1- Set swimming pool water temp efficiently and economically to provide you
comfort and pleasure.
2- User may choose the model based off technical parameters presented in this
manual. This series of swimming pool heater has been optimized in factory
(refer to technical parameter table).
II. Features 1- Sensitive and accurate temp control and water temp display. 2-
High-pressure and low-pressure protection. 3- Protection in case of too low or
no water flow 4- Exceeding low temp auto stop protection. 5- Temp control
compulsory defrosting. 6- International brand compressor. 7- High efficient
titanium heat exchanger 8- Easy installation and operation.
3
III. Technical Parameter
Model
Voltage
Frequency/phase
Heating current (air80°F,water80°F) A Heating power (air80°F,water80°F) kW
Design pressure (High)
Design pressure (Low)
Refrigerant(R410A) oz Net weight Kgs Water circulation flow L/min Noise at
10Feet dB(A) Waterproof class
PHP-50 PHP-65 PHP-90 PHP-110 PHP-140 208-230V 208-230V 208-230V 208-230V
208-230V 60Hz/1Ph 60Hz/1Ph 60Hz/1Ph 60Hz/1Ph 60Hz/1Ph
1.6-10.2 2.5-13.1 2.9~16.9 2.9~23.7 3.6~31.3
0.3-2.3
609 PSIG 261 PSIG 38.8
52
83~117
50
IPX4
0.56-3.0
609 PSIG 261 PSIG 47.6
63
108~142
50
IPX4
0.6~3.9
609 PSIG 261 PSIG 98.8
85
125~158
50
IPX4
0.6~5.4
609 PSIG 261 PSIG 141.0
125
133~167
50
IPX4
0.8~6.9
609 PSIG 261 PSIG 176.4
143
133~254
50
IPX4
Notice:
1. This product works well under water temp 80oF to104oF, air temp 32oF to
109oF, efficiency will not be guaranteed out of this range. Please take into
consideration that the pool heater performance and parameters are different
under various conditions. Always refer to your pool expert on the correct unit
for the size of your pool and your needs as these will vary depending on
operating conditions. You may also contact support for confirmation. 2.
Related parameters are subject to adjustment periodically for technical
improvement without further notice. For details on your unit please refer to
the nameplate on the product.
4
IV. Dimension
C
E
H GF
A
B
D
Size(inch) Name
A
B
C
D
E
F
G
H
Model
PHP-50
12.4 23.2 12.3 13.4 37.8 13.0 2.9 25.9
PHP-65
15.6 23.2 15.4 16.5 37.8 14.2 2.9 29.8
PHP-90
15.6 28.3 15.4 16.5 43.0 24.4 2.9 37.7
Size(inch) Name
A
B
C
D
E
F
G
H
Model
PHP-110
36.3 17.6 35.6 37.2 27.8 20.9 3.3 38.5
PHP-140
39.8 20.5 32.3 40.8 39.2 20.9 3.3 41.5
Above data is subject to modification without notice.
5
Note:
The picture above is the specification diagram of the pool heater, for
technician’s installation and layout reference only. The product is subject to
adjustment periodically for improvement without further notice.
V. Installation instruction
1. Drawing for water pipes connection.
(Notice: The drawing demonstration and layout of the pipes is only for
reference.)
6
2. Electric Wiring Diagram
Grounding
Grounding
Note: 1) Must be hard wired, no plug allowed. 2) The swimming pool heater must be grounded. 3) WARNING: Before obtaining access to terminals, all supply circuits must be disconnected.
Options for protecting devices and cable specification
MODEL
PHP-50
Rated Current A
20
Breaker
Rated Residual
Action
30
Current mA
Fuse
A
20
PHP-65 30 30 30
PHP-90 30 30 30
PHP-110 40 30 40
PHP-140 50 30 50
Power Cord AWG 2×12
2×10
2×10
2×8
2×8
Signal cable AWG 2×20
2×20
2×20
2×20
2×20
Above data is subject to modification without notice.
Note: The above data is adapted to power cord 393.7in. If power cord is 393.7in, wire diameter must be increased. The signal cable
can be extended to 1968.5in at most.
7
3. Installation and Requirements
The swimming pool heater must be installed by a pool professional. End users
are not qualified to install the heater. Damage may occur to the heater or
threaten the safety of the user. Pool professional guidelines will vary
depending on your country, state or province regulation and can include HVAC
technicians or electricians. Warranty will be voided if done otherwise. Notes:
- The inlet and outlet water unions can’t bear the weight of soft pipes. The
heat
pump must be connected with hard pipes! - In order to guarantee the heating efficiency, the water pipe length should
be 393.7in between the pool and the heat pump.
A. Installation 1) The swimming pool heater should be installed in a location with good ventilation; 2) The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation must be solid and fastened; the bracket must be strong and antirust treated; 3) Don’t stack substances that will block air flow near inlet or outlet area, and no barrier within 20in behind the main heater, or the efficiency of the heater will be reduced or even halted; 4) The heater needs an appended pump (Supplied by the user). The recommended pump specification-flux: refer to Technical Parameter, Max. lift 393.7in; 5) When the heater is running, there will be condensation water discharged from the bottom. Attach the drainage nozzle (accessory for PHP-50-PHP-65-PHP-90 models) into the hole under the unit, then connect the pipe to drain the condensation water out. B. Wiring 1) Connect to appropriate power supply; the voltage should comply with the rated
8
voltage of the products. 2) Heater must be grounded. 3) Wiring must be handled
by a professional technician respecting circuit diagram. 4) 1HVAC units do not
require a GFCI to function. If required by code, please respect following
guidelines.
i. Set GFCI according to the local code for wiring (current leakage 30mA). ii.
Some GFCI breakers may cause nuisance trips with variable speed products.
Consult a certified electrician, your retailer or support to confirm wiring.
Product Warranty does not cover electrical wiring. 5) The layout of power
cable and signal cable should be orderly and not interfere with each other. 6)
The appliance shall be installed in accordance with national wiring
regulations. C. Switch on after finishing all wiring construction and re-
checking. Pay attention to the following points: 1. The heat pump must be
installed OUTSIDE in a well ventilated area to avoid air recirculation, or in
a place with adequate room for both installation and maintenance. Please refer
to the following illustration for side fan models (PHP50/PHP-65/PHP-90). 2.
For top fan models (PHP-110/PHP-140), clearance above the unit should be 39.4”
unobstructed and 20” around.
A minimum of 20″ of clearance from walls, shrubbery, equipment, etc. is
required around the entire pump circumference. This allows for ample air
intake. No less than 39.4″ clearance on the air outlet is required to prevent
recirculation of air. We recommend to not place the unit underneath eaves,
decks, or porches, as this causes recirculation of discharged air, or the
efficiency of the heater will be reduced or even stopped.
The unit shouldn’t be installed in a confined space or an area with poor
ventilation
9
VI. Operation instruction
Picture for keys
SYMBOL
DESIGNATION ON / OFF Mode Speed
FUNCTION 1. Power On / Off 2. Wi-Fi setting Heating 18°C40°C Cooling 12°C30°C
Auto 12°C40°C
Select Smart / Silence mode
Up / Down Adjust set temperature
Timer
Time and timer setting
10
Screen display
Water inlet temperature
Water outlet temperature Smart / Silence mode
Heating Cooling
Auto Heating capacity
percentage Wi-Fi connection
Water inlet Water outlet
Time Timer
11
Routine operation 1. If no operation in 30 seconds, screen will be locked and be dark, press any buttons to make screen on.
2. Power On/off: When the screen is on, press on/off heat pump.
to power
3. Mode Selection: Press
to select mode.
Auto : adjustable temperature range 12~40°C
Heating : adjustable temperature range 18~40°C
Cooling : adjustable temperature range 12~30°C 4. Temperature setting:
When screen is unlocked, short press
or
, the
temperature setting value will be flashing, then short press
or
to add or subtract, long press
or
more than 0.5 seconds will increase or decrease rapidly, short
press
or 5 seconds without operation will automatically
exit the temperature setting state.
5. Smart/Silence mode selection:
Press
to enter Smart mode, and screen shows ,
then press shows . 6. Defrosting
to enter Silence mode, the screen
12
a. Auto Defrosting: When heat pump is defrosting, will
be flashing. After defrosting, will stop flashing. b. Compulsory Defrosting: When heat pump is heating,
press
and
together for 5 seconds to start
compulsory defrosting, and will be flashing. After
defrosting, will stop flashing.
Note: Compulsory defrosting intervals should be more than 30 minutes and the
compressor should run for more than 10 minutes at heating mode. 7. Temperature
display conversion between °C and °F:
Press
and
together for 5 seconds to switch
between °C and °F.
8. Wi-Fi setting
Please kindly check the last page.
VII. Advanced application 1.Parameter Checking
a. Press
and
together for 5 seconds to enter
“Parameter Checking” status, the parameter code
“P0” and the parameter value “0” will display on the
screen, such as “P0 0”, which means water pump
running way is continuous.
b. In “Parameter Checking” status, press
or
13
to check the parameters.
2.Parameter Modification
In “Parameter Checking” status, press
to enter the
“Parameter Modification” mode, press
or
to
change the values, then press
to confirm and quit
“Parameter Modification” mode, press “Parameter Checking” status. 3.Parameter list
to quit
NO .
Content
Adjust range
Step length
0: Continuous
P0
Water Pump Running Way
1: Water temp control 2: Time/water temp
1
control
Time Setting
(Only available when
P1 the water pump
10 ~ 120 min
5 min
running way is set to
“2”)
Compressor
Continuously
P2 Running Time
30 ~ 90 min
1 min
between Defrosting
Mode
14
P3
Defrosting Entry Temp
P4
Maximum Defrosting Running Time
P5 Defrosting Exit Temp
4.Running status checking
-17~0°C / 1~32°F 1 ~ 12 min
8~30°C /46~86°F
1°C /1°F
1 min
1°C /1°F
Press
for 5 seconds, enter into “Running status
checking”, and the screen alternately shows status
point “C0” and its corresponding value. Check all status
points and their corresponding value through
or
, Press mode.
to quit “running status checking”
Running status checking list
Symbol
Content
C0
Inlet water temp.
C1
Outlet water temp.
C2
Ambient temp.
C3
Exhaust temp.
C4
Outer coil pipe temp. (Evaporator)
C5
Gas return temp.
Unit °C / °F °C / °F °C / °F °C / °F °C / °F °C / °F
15
C6
Inner coil pipe temp. (Titanium heat exchanger)
°C / °F
C9
Cooling plate temp.
°C / °F
C10
Electronic expansion valve opening
P
C11
DC fan speed
(r/min)
VIII. Timer
The timer function is a 24-hour system, please calibrate with local time.
a. Real time setting: Press
for 5 seconds to enter real
time setting, short press
or
to adjust the value.
Press and hold
or
for more than 0.5 seconds
to increase or decrease rapidly, press
to confirm,
press
to cancel the setting.
b. Timer setting
Press
for 10 seconds and release to enter the timer
setting, the timer icon will light up.
16
a) Timer on setting
1. Timer on flashing, press day.
to select timer on once / timer on cycle every
2. Press
or
decrease rapidly.
to adjust the timing time, long press will increase or
3. Press
to confirm the operation and enter the timer off setting.
4. Press
to cancel the operation and exit the timer setting.
The icon in the controller indicates as below: Timer on every day
Timer on one time
No symbol
No timer setting
17
b) Timer off setting
1. Timer off flashing, press cycle every day.
to select timer off once / timer off
2. Press
or
to adjust the timing time, long press will
increase or decrease rapidly.
3. Press
to confirm the operation and exit.
4. Press
to cancel the operation and exit the timer setting.
The icon in the controller indicates as below:
Timer off every day
Timer off one time
No symbol
No timer setting
18
After setting, the icon in the lower left corner indicates as below:
No symbol
Timer on every day Timer on every day Timer on every day Timer on one time
Timer on one time Timer on one time
No timer on
Timer off every day
Timer off one time
No timer off Timer off every
day Timer off one time
No timer off Timer off every
day
No timer on Timer off one time
No timer on
No timer off
IX. Testing
1. Inspection before use A. Check installation of the entire heater and pipe
connections
according to the pipe connecting drawing; B. Check the electric wiring
according to the electric wiring diagram;
and grounding connection; C. Make sure that the main heater power switch is
off; D. Check the temperature setting; E. Check the air inlet and outlet.
19
2. Trial A. The user must start the water pump before the heat pump, and turn
off the heat pump before the water pump, or the heat pump could be damaged; B.
The user should start the water pump, and check for any leakage of water.
Power the heat pump on by pressing the ON/OFF button of the heat pump, and set
suitable temperature in the thermostat. C. In order to lower the electrical
surcharge, the heater is equipped with a timer delayed starting function. When
starting the heater; the fan will start 1 minute earlier than the compressor;
D. After the pool heat pump starts up, check for any abnormal noise from the
heater.
X. Precautions
1. Attention A. Set proper temperature in order to get comfortable water
temperature. Avoid overheating. B. Do not stack substances that can block air
flow near inlet or outlet area as the efficiency of the heater will be reduced
or even stopped. C. Do not put hands near the water outlet in the swimming
pool, and don’t remove the screen of the fan at any time; D. If there are
abnormal conditions such as noise, smell, smoke, electrical issues or leakage,
please switch off the machine immediately and contact the local dealer or
Support. Don’t try to repair it yourself; E. Don’t use or stock combustible
gas or liquid such as thinners, paint and fuel to avoid fire; F. In order to
optimize the heating effect, please install heat preservation insulation on
pipes between swimming pool and the heater. During running period of the
swimming pool heater, please use a recommended cover on the swimming pool;
20
G. Connecting pipes of the swimming pool and the heater should be 393.7in, or
the heating effect of the heater cannot be ensured;
2. Safety APlease keep the main power supply switch far away from the
children; BWhen a power stoppage happens during running, and later the power
is restored, the heater will start up automatically. So please switch off the
power supply when there is a power cut, and reset temp when power is restored;
CPlease switch off the main power supply in lightning and storm weather to
prevent from machine damage that caused by lightning; DIf the machine is
stopped for a long time, please cut off the power supply and drain water clear
of the machine by opening the tap of inlet pipe and outlet pipe.
XI. Maintenance
Caution: Danger of electric shock
1. “Cut off” power supply of the heater before cleaning, examination and
repairing 2. Do not touch the electronic components until the LED indication
lights on PCB
is off/ turn off.
A. In winter season or in the off-season
1. Cut off power supply to prevent any heater damage 2. Drain water clear of
the heater. 3. Cover the heater body when not in use.
Important: Unscrew the water nozzle of inlet pipe to let the water flow out.
When the water in machine freezes in winter season, the titanium heat
exchanger may be damaged. This is not covered on warranty.
21
BPlease clean the heater’s coil with household detergents or clean water,
NEVER use gasoline, thinners or any similar fuel. This will ensure a good air
flow.
CCheck bolts, cables and connections regularly.
XII. Trouble shooting for common faults
Failure
Reason
Solution
No power
Wait until the power recovers
Swimming pool heat pump does
not run
Power switch is off Fuse burned
Switch on the power Check to change the fuse
The breaker is off Check to turn on the breaker
Air inlet blocked
Remove the obstacles
Running but not Air outlet blocked Remove the obstacles
heating
3minutes protection Wait patiently
Set temp too low Set proper heating temperature
If the above solution doesn’t work, please contact your dealer or Support
Pool Products. Don’t try to repair the heater yourself.
22
Failure code
NO. Display
Not failure description
1
E3 No water protection
2
E5 Power supply excesses operation range
3
E6
Excessive temp difference between inlet and outlet water(Insufficient water flow protection)
4
Eb Ambient temperature too high or too low protection
5
Ed Anti-freezing reminder
NO. Display
Failure description
1
E1 High pressure protection
2
E2 Low pressure protection
3
E4 Phases lack protection (three phase model only)
4
E7 Water outlet temp too high or too low protection
5
E8 High exhaust temp protection
6
EA Evaporator overheat protection (only at cooling mode)
7
P0 Controller communication failure
8
P1 Water inlet temp sensor failure
9
P2 Water outlet temp sensor failure
10
P3 Gas exhaust temp sensor failure
11
P4 Heating (Evaporator)coil pipe temp sensor
12
P5 Gas return temp sensor failure
13
P6 Cooling (Titanium heat exchanger) coil pipe temp sensor
14
P7 Ambient temp sensor failure
15
P8 Cooling plate sensor failure
16
P9 Current sensor failure
17
PA Restart memory failure
18
F1 Compressor drive module failure
19
F2 PFC module failure
20
F3 Compressor start failure
21
F4 Compressor running failure
22
F5 Inverter board over current protection
23
F6 Inverter board overheat protection
24
F7 Current protection
25
F8 Cooling plate overheat protection
26
F9 Fan motor failure
27
Fb Capacitor no charging protection
28
FA PFC module over current protection
23
XIII. Wi-Fi Setting 1.APP Download
Android Mobile please download from
iPhone please download from
2.Account registration a) Registration by Cell phone number/Email
24
b) Cell phone number registration
3.Create family Please set a name for the family and choose the room of the
device.
25
4.Three methods of device binding Please connect your phone to the Wi-Fi network first.
4.1.Auto Discovery (Bluetooth)
a) Please make sure the Bluetooth function is enabled on your phone.
b) Press
for 3 seconds after the screen unlock,
will be flashing rapidly to enter Wi-Fi binding status. c) Click “Add Device”,
wait for the app to search for the
device and then click “add”, then follow the instructions below to finish the
device binding.
26
Note: (1). It will take some time to scan, please be patient. (2). Only Wi-Fi modules with Bluetooth functions can use this method.
4.2.EZ Mode (Easy-connect) a) Activate the Wi-Fi module
Press
for 3 seconds after the screen unlocks,
will be flashing rapidly to enter Wi-Fi binding status. b) Click “Add device”, and follow the instructions below to
finish binding.
display on the screen once the Wi-
Fi connection success.
27
Note: After allowing the APP to locate, it can read the Wi-Fi name
automatically.
28
4.3.AP Mode Activate Wi-Fi module
a) Press
for 10 seconds after the screen unlock,
will be flashing slowly to enter Wi-Fi binding
status. b) Click “Add device”, and follow the instructions below
to finish binding.
display on the screen once the
Wi-Fi connection success.
Note: If it doesn’t jump automatically, click “Confirm hotspot connection,
next”.
29
4.4.If connect fails, please make sure your network name and password are correct. And your router, mobile phone and device are as close as possible.
4.5.Wi-Fi rebinding (When Wi-Fi password changes or network configuration changes)
Press
for 10 seconds,
will be flashing slowly for 60
seconds. Then
will be off. The original binding will be
removed. Follow steps above for rebinding.
Remarks: Please make sure the router is configured at 2.4 GHz.
30
5.Operation instructions The following instructions are for heat pumps with
heating and cooling functions.
More share device Heating capacity percentage Indicate the working status The
current swimming pool water temp Switching °C/°F Setting temp Temp adjustment
slider Smart/Silence Selection Cloud Timer Heating/Cooling/Auto Selection
ON/OFF
31
6. Share devices with your family members After binding, if your family
members also want to control the device. Please let your family members
register the APP first, and then the administrator can operate as below (The
following pictures are for reference only):
Then your family members will see this heat pump once they log in to the APP.
Notice: (1). The weather forecast is just for reference. (2). APP is subject
to update without notice.
The factory reserves the final interpretation right. And keep the right to
stop or change product specification and design without prior notice at any
time, no need to bear the resulting obligations.
32
XIV. Warranty & After-Service
1HVAC products warranty is managed by Moov Pool Products. Please note 1HVAC
products are not a brand owned by Moov Pool Products. Only 1HVAC products
listed above are managed by Moov Pool Products. Warranty begins at time of
purchase. Warranty is only valid upon first install.
Some claims will not be approved under any circumstances by Moov Pool
Products. Such claims include and are not limited to:
– Heat Exchanger broken due to water left in through unproper winterization.
Appropriate winterization can be found on page 15 of this manual. Any other
winterization default claims will be refused.
– Heat Pump damaged by meteorological events such Hurricanes, Tornados, Hail,
Earthquakes and any other act of god event.
– Units not installed by an appropriate technician. The trade job of these
technicians will vary depending on the region of the install and can include
1HVAC technicians or electricians. Electrical wiring or product manipulations
are included.
– Any unsatisfactory claim. Heat Pumps efficiency will vary depending on
various factors such as outdoor temperature, required temperature, air flow,
sun presence, humidity, pool sizing, heat pump distance from the pool and much
more. Please always refer to your pool expert to select the right unit
tailored to your needs or contact Moov Pool Products for a recommendation.
All warranty claims must be approved by an authorized Moov Pool Products
employee. For more information on warranties or to submit a claim, contact
Moov Pool Products.
Moov Pool Products Inc Head office located in Orlando, Florida, USA
www.moovpool.com / (407)-559-2077
The factory reserves the final interpretation right and keep the right to stop
or change product specification and design without prior notice at any time,
no need to bear the resulting obligations.