1HVAC PHP Series Inverter Heat Pump For Swimming Pools Owner’s Manual

September 9, 2024
1HVAC

PHP Series Inverter Heat Pump For Swimming Pools

“`html

Specifications:

Model| Voltage| Frequency/Phase| Design Pressure (High)| Design Pressure (Low)| Refrigerant (R410A) oz| Net Weight Kgs| Water Circulation Flow L/min| Noise at 10 Feet dB(A)| Waterproof Class
---|---|---|---|---|---|---|---|---|---
PHP-50| 208-230V| 60Hz/1Ph| 609 PSIG| 261 PSIG| 1.6-10.2| 38.8| 52| 83-117| IPX4

Product Usage Instructions:

I. Application:

  1. Efficiently set swimming pool water temperature for comfort and
    pleasure.

  2. Choose the model based on technical parameters provided.

II. Features:

  • Sensitive and accurate temperature control with water
    temperature display.

  • High-pressure and low-pressure protection.

  • Protection against low or no water flow.

  • Auto stop protection for excessively low temperatures.

  • Compulsory defrosting for temperature control.

  • Utilizes international brand compressor.

  • Equipped with a high-efficiency titanium heat exchanger.

  • Easy installation and operation.

III. Technical Parameter:

IV. Dimension:

V. Installation Instruction:

  1. Detailed drawing for water pipes connection (for
    reference).

  2. Electric wiring diagram with grounding instructions.

  3. Installation and requirements must be handled by a pool
    professional to avoid damage or safety risks.

FAQ:

Q: Can the swimming pool heater be installed by end users?

A: No, the swimming pool heater must be installed by a pool
professional to prevent damage to the heater or safety risks to the
user. Installation guidelines may vary based on regulations and can
include HVAC technicians or electricians.

“` [pdfjs-viewer url=”/m/aa2e625e563f23b3cc41db0b2ee8da38abca252d8ea8d5d4398037ad8657802c_optim.pdf” viewer_width=100% viewer_height=800px fullscreen=true download=true print=true]

PHP-50 / PHP-65 / PHP-90 / PHP-110 / PHP-140 Inverter Heat Pump for Swimming Pools
Please read the manual in real time

Content
I. Application …………………………………………………………………………………. 3 II. Features…………………………………………………………………………………….. 3 III. Technical Parameter ………………………………………………………………….. 4 IV. Dimension………………………………………………………………………………….. 5 V. Installation instruction ………………………………………………………………… 6 VI. Operation instruction………………………………………………………………… 10 VII. Advanced application……………………………………………………………….. 13 VIII. Timer ……………………………………………………………………………………….. 16 a) Timer on setting………………………………………………………………………. 17 b) Timer off setting………………………………………………………………………. 18 IX. Testing……………………………………………………………………………………… 19 X. Precautions ……………………………………………………………………………… 20 XI. Maintenance…………………………………………………………………………….. 21 XII. Trouble shooting for common faults …………………………………………. 22 XIII. Wi-Fi Setting…………………………………………………………………………….. 24 XIV. Warranty & After-Service………………………………………………………….. 33
1

Special Attention:
A. This product is only for swimming pool water heating applications and can’t be used for the heating for any other liquid materials. B. The inlet and outlet water nozzles can’t bear the weight of external pipes. C. The main power switch should be out of the reach of children. D. Make sure the power is switched off before opening the case of the product. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
NOTE:
A. The swimming pool heat pump must be installed by a qualified electrician. These regulations may change depending on the Country, Province or State you live in. B. To maximize your swimming comfort, set proper heating temperature. The recommended heating temperature is 85’F. The unit can work above and below this recommendation up to a specific capacity depending on operating conditions. Please contact support for more information. C. Don’t put obstacles near the air inlet and outlet of the heat pump. D. This heat pump has power-off memory function. E. When the ambient temperature is below 3’C, make sure to switch off the main power, and drain off the water from heat exchanger. F. Never place your hand or any other object in the air inlet or outlet of the heat pump. G. If any abnormal circumstances discovered, ex: abnormal noise, smells, smokes and leakage of electricity, switch the main power off immediately and contact your local dealer/installer or supprt directly. Do not try to repair the heat pump yourself.
2

I. Application
1- Set swimming pool water temp efficiently and economically to provide you comfort and pleasure.
2- User may choose the model based off technical parameters presented in this manual. This series of swimming pool heater has been optimized in factory (refer to technical parameter table).
II. Features 1- Sensitive and accurate temp control and water temp display. 2- High-pressure and low-pressure protection. 3- Protection in case of too low or no water flow 4- Exceeding low temp auto stop protection. 5- Temp control compulsory defrosting. 6- International brand compressor. 7- High efficient titanium heat exchanger 8- Easy installation and operation.
3

III. Technical Parameter

Model
Voltage
Frequency/phase
Heating current (air80°F,water80°F) A Heating power (air80°F,water80°F) kW
Design pressure (High)
Design pressure (Low)
Refrigerant(R410A) oz Net weight Kgs Water circulation flow L/min Noise at 10Feet dB(A) Waterproof class

PHP-50 PHP-65 PHP-90 PHP-110 PHP-140 208-230V 208-230V 208-230V 208-230V 208-230V 60Hz/1Ph 60Hz/1Ph 60Hz/1Ph 60Hz/1Ph 60Hz/1Ph
1.6-10.2 2.5-13.1 2.9~16.9 2.9~23.7 3.6~31.3

0.3-2.3
609 PSIG 261 PSIG 38.8
52
83~117
50
IPX4

0.56-3.0
609 PSIG 261 PSIG 47.6
63
108~142
50
IPX4

0.6~3.9
609 PSIG 261 PSIG 98.8
85
125~158
50
IPX4

0.6~5.4
609 PSIG 261 PSIG 141.0
125
133~167
50
IPX4

0.8~6.9
609 PSIG 261 PSIG 176.4
143
133~254
50
IPX4

Notice:
1. This product works well under water temp 80oF to104oF, air temp 32oF to 109oF, efficiency will not be guaranteed out of this range. Please take into consideration that the pool heater performance and parameters are different under various conditions. Always refer to your pool expert on the correct unit for the size of your pool and your needs as these will vary depending on operating conditions. You may also contact support for confirmation. 2. Related parameters are subject to adjustment periodically for technical improvement without further notice. For details on your unit please refer to the nameplate on the product.

4

IV. Dimension

C

E

H GF

A

B

D

Size(inch) Name

A

B

C

D

E

F

G

H

Model

PHP-50

12.4 23.2 12.3 13.4 37.8 13.0 2.9 25.9

PHP-65

15.6 23.2 15.4 16.5 37.8 14.2 2.9 29.8

PHP-90

15.6 28.3 15.4 16.5 43.0 24.4 2.9 37.7

Size(inch) Name

A

B

C

D

E

F

G

H

Model

PHP-110

36.3 17.6 35.6 37.2 27.8 20.9 3.3 38.5

PHP-140

39.8 20.5 32.3 40.8 39.2 20.9 3.3 41.5

Above data is subject to modification without notice.

5

Note:
The picture above is the specification diagram of the pool heater, for technician’s installation and layout reference only. The product is subject to adjustment periodically for improvement without further notice.
V. Installation instruction
1. Drawing for water pipes connection.
(Notice: The drawing demonstration and layout of the pipes is only for reference.)
6

2. Electric Wiring Diagram

Grounding

Grounding

Note: 1) Must be hard wired, no plug allowed. 2) The swimming pool heater must be grounded. 3) WARNING: Before obtaining access to terminals, all supply circuits must be disconnected.

Options for protecting devices and cable specification

MODEL

PHP-50

Rated Current A

20

Breaker

Rated Residual
Action

30

Current mA

Fuse

A

20

PHP-65 30 30 30

PHP-90 30 30 30

PHP-110 40 30 40

PHP-140 50 30 50

Power Cord AWG 2×12

2×10

2×10

2×8

2×8

Signal cable AWG 2×20

2×20

2×20

2×20

2×20

Above data is subject to modification without notice.

Note: The above data is adapted to power cord 393.7in. If power cord is 393.7in, wire diameter must be increased. The signal cable

can be extended to 1968.5in at most.

7

3. Installation and Requirements
The swimming pool heater must be installed by a pool professional. End users are not qualified to install the heater. Damage may occur to the heater or threaten the safety of the user. Pool professional guidelines will vary depending on your country, state or province regulation and can include HVAC technicians or electricians. Warranty will be voided if done otherwise. Notes:

  1. The inlet and outlet water unions can’t bear the weight of soft pipes. The heat
    pump must be connected with hard pipes!
  2. In order to guarantee the heating efficiency, the water pipe length should be 393.7in between the pool and the heat pump.
    A. Installation 1) The swimming pool heater should be installed in a location with good ventilation; 2) The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation must be solid and fastened; the bracket must be strong and antirust treated; 3) Don’t stack substances that will block air flow near inlet or outlet area, and no barrier within 20in behind the main heater, or the efficiency of the heater will be reduced or even halted; 4) The heater needs an appended pump (Supplied by the user). The recommended pump specification-flux: refer to Technical Parameter, Max. lift 393.7in; 5) When the heater is running, there will be condensation water discharged from the bottom. Attach the drainage nozzle (accessory for PHP-50-PHP-65-PHP-90 models) into the hole under the unit, then connect the pipe to drain the condensation water out. B. Wiring 1) Connect to appropriate power supply; the voltage should comply with the rated
    8

voltage of the products. 2) Heater must be grounded. 3) Wiring must be handled by a professional technician respecting circuit diagram. 4) 1HVAC units do not require a GFCI to function. If required by code, please respect following guidelines.
i. Set GFCI according to the local code for wiring (current leakage 30mA). ii. Some GFCI breakers may cause nuisance trips with variable speed products.
Consult a certified electrician, your retailer or support to confirm wiring. Product Warranty does not cover electrical wiring. 5) The layout of power cable and signal cable should be orderly and not interfere with each other. 6) The appliance shall be installed in accordance with national wiring regulations. C. Switch on after finishing all wiring construction and re- checking. Pay attention to the following points: 1. The heat pump must be installed OUTSIDE in a well ventilated area to avoid air recirculation, or in a place with adequate room for both installation and maintenance. Please refer to the following illustration for side fan models (PHP50/PHP-65/PHP-90). 2. For top fan models (PHP-110/PHP-140), clearance above the unit should be 39.4” unobstructed and 20” around.
A minimum of 20″ of clearance from walls, shrubbery, equipment, etc. is required around the entire pump circumference. This allows for ample air intake. No less than 39.4″ clearance on the air outlet is required to prevent recirculation of air. We recommend to not place the unit underneath eaves, decks, or porches, as this causes recirculation of discharged air, or the efficiency of the heater will be reduced or even stopped.
The unit shouldn’t be installed in a confined space or an area with poor ventilation
9

VI. Operation instruction
Picture for keys

SYMBOL

DESIGNATION ON / OFF Mode Speed

FUNCTION 1. Power On / Off 2. Wi-Fi setting Heating 18°C40°C Cooling 12°C30°C Auto 12°C40°C
Select Smart / Silence mode

Up / Down Adjust set temperature

Timer

Time and timer setting

10

Screen display
Water inlet temperature

Water outlet temperature Smart / Silence mode
Heating Cooling
Auto Heating capacity
percentage Wi-Fi connection
Water inlet Water outlet
Time Timer
11

Routine operation 1. If no operation in 30 seconds, screen will be locked and be dark, press any buttons to make screen on.

2. Power On/off: When the screen is on, press on/off heat pump.

to power

3. Mode Selection: Press

to select mode.

Auto : adjustable temperature range 12~40°C

Heating : adjustable temperature range 18~40°C

Cooling : adjustable temperature range 12~30°C 4. Temperature setting:

When screen is unlocked, short press

or

, the

temperature setting value will be flashing, then short press

or

to add or subtract, long press

or

more than 0.5 seconds will increase or decrease rapidly, short

press

or 5 seconds without operation will automatically

exit the temperature setting state.

5. Smart/Silence mode selection:

Press

to enter Smart mode, and screen shows ,

then press shows . 6. Defrosting

to enter Silence mode, the screen

12

a. Auto Defrosting: When heat pump is defrosting, will

be flashing. After defrosting, will stop flashing. b. Compulsory Defrosting: When heat pump is heating,

press

and

together for 5 seconds to start

compulsory defrosting, and will be flashing. After

defrosting, will stop flashing.
Note: Compulsory defrosting intervals should be more than 30 minutes and the compressor should run for more than 10 minutes at heating mode. 7. Temperature display conversion between °C and °F:

Press

and

together for 5 seconds to switch

between °C and °F.

8. Wi-Fi setting

Please kindly check the last page.

VII. Advanced application 1.Parameter Checking

a. Press

and

together for 5 seconds to enter

“Parameter Checking” status, the parameter code

“P0” and the parameter value “0” will display on the

screen, such as “P0 0”, which means water pump

running way is continuous.

b. In “Parameter Checking” status, press

or

13

to check the parameters.

2.Parameter Modification

In “Parameter Checking” status, press

to enter the

“Parameter Modification” mode, press

or

to

change the values, then press

to confirm and quit

“Parameter Modification” mode, press “Parameter Checking” status. 3.Parameter list

to quit

NO .

Content

Adjust range

Step length

0: Continuous

P0

Water Pump Running Way

1: Water temp control 2: Time/water temp

1

control

Time Setting

(Only available when

P1 the water pump

10 ~ 120 min

5 min

running way is set to

“2”)

Compressor

Continuously

P2 Running Time

30 ~ 90 min

1 min

between Defrosting

Mode

14

P3

Defrosting Entry Temp

P4

Maximum Defrosting Running Time

P5 Defrosting Exit Temp

4.Running status checking

-17~0°C / 1~32°F 1 ~ 12 min
8~30°C /46~86°F

1°C /1°F
1 min
1°C /1°F

Press

for 5 seconds, enter into “Running status

checking”, and the screen alternately shows status

point “C0” and its corresponding value. Check all status

points and their corresponding value through

or

, Press mode.

to quit “running status checking”

Running status checking list

Symbol

Content

C0

Inlet water temp.

C1

Outlet water temp.

C2

Ambient temp.

C3

Exhaust temp.

C4

Outer coil pipe temp. (Evaporator)

C5

Gas return temp.

Unit °C / °F °C / °F °C / °F °C / °F °C / °F °C / °F

15

C6

Inner coil pipe temp. (Titanium heat exchanger)

°C / °F

C9

Cooling plate temp.

°C / °F

C10

Electronic expansion valve opening

P

C11

DC fan speed

(r/min)

VIII. Timer
The timer function is a 24-hour system, please calibrate with local time.

a. Real time setting: Press

for 5 seconds to enter real

time setting, short press

or

to adjust the value.

Press and hold

or

for more than 0.5 seconds

to increase or decrease rapidly, press

to confirm,

press

to cancel the setting.

b. Timer setting

Press

for 10 seconds and release to enter the timer

setting, the timer icon will light up.

16

a) Timer on setting

1. Timer on flashing, press day.

to select timer on once / timer on cycle every

2. Press

or

decrease rapidly.

to adjust the timing time, long press will increase or

3. Press

to confirm the operation and enter the timer off setting.

4. Press

to cancel the operation and exit the timer setting.

The icon in the controller indicates as below: Timer on every day

Timer on one time

No symbol

No timer setting

17

b) Timer off setting

1. Timer off flashing, press cycle every day.

to select timer off once / timer off

2. Press

or

to adjust the timing time, long press will

increase or decrease rapidly.

3. Press

to confirm the operation and exit.

4. Press

to cancel the operation and exit the timer setting.

The icon in the controller indicates as below:

Timer off every day

Timer off one time

No symbol

No timer setting

18

After setting, the icon in the lower left corner indicates as below:

No symbol

Timer on every day Timer on every day Timer on every day Timer on one time Timer on one time Timer on one time
No timer on

Timer off every day
Timer off one time
No timer off Timer off every
day Timer off one time
No timer off Timer off every
day

No timer on Timer off one time

No timer on

No timer off

IX. Testing
1. Inspection before use A. Check installation of the entire heater and pipe connections
according to the pipe connecting drawing; B. Check the electric wiring according to the electric wiring diagram;
and grounding connection; C. Make sure that the main heater power switch is off; D. Check the temperature setting; E. Check the air inlet and outlet.
19

2. Trial A. The user must start the water pump before the heat pump, and turn
off the heat pump before the water pump, or the heat pump could be damaged; B. The user should start the water pump, and check for any leakage of water. Power the heat pump on by pressing the ON/OFF button of the heat pump, and set suitable temperature in the thermostat. C. In order to lower the electrical surcharge, the heater is equipped with a timer delayed starting function. When starting the heater; the fan will start 1 minute earlier than the compressor; D. After the pool heat pump starts up, check for any abnormal noise from the heater.
X. Precautions
1. Attention A. Set proper temperature in order to get comfortable water temperature. Avoid overheating. B. Do not stack substances that can block air flow near inlet or outlet area as the efficiency of the heater will be reduced or even stopped. C. Do not put hands near the water outlet in the swimming pool, and don’t remove the screen of the fan at any time; D. If there are abnormal conditions such as noise, smell, smoke, electrical issues or leakage, please switch off the machine immediately and contact the local dealer or Support. Don’t try to repair it yourself; E. Don’t use or stock combustible gas or liquid such as thinners, paint and fuel to avoid fire; F. In order to optimize the heating effect, please install heat preservation insulation on pipes between swimming pool and the heater. During running period of the swimming pool heater, please use a recommended cover on the swimming pool;
20

G. Connecting pipes of the swimming pool and the heater should be 393.7in, or the heating effect of the heater cannot be ensured;
2. Safety APlease keep the main power supply switch far away from the children; BWhen a power stoppage happens during running, and later the power is restored, the heater will start up automatically. So please switch off the power supply when there is a power cut, and reset temp when power is restored; CPlease switch off the main power supply in lightning and storm weather to prevent from machine damage that caused by lightning; DIf the machine is stopped for a long time, please cut off the power supply and drain water clear of the machine by opening the tap of inlet pipe and outlet pipe.
XI. Maintenance
Caution: Danger of electric shock
1. “Cut off” power supply of the heater before cleaning, examination and repairing 2. Do not touch the electronic components until the LED indication lights on PCB
is off/ turn off.
A. In winter season or in the off-season
1. Cut off power supply to prevent any heater damage 2. Drain water clear of the heater. 3. Cover the heater body when not in use.
Important: Unscrew the water nozzle of inlet pipe to let the water flow out.
When the water in machine freezes in winter season, the titanium heat exchanger may be damaged. This is not covered on warranty.
21

BPlease clean the heater’s coil with household detergents or clean water, NEVER use gasoline, thinners or any similar fuel. This will ensure a good air flow.
CCheck bolts, cables and connections regularly.
XII. Trouble shooting for common faults

Failure

Reason

Solution

No power

Wait until the power recovers

Swimming pool heat pump does
not run

Power switch is off Fuse burned

Switch on the power Check to change the fuse

The breaker is off Check to turn on the breaker

Air inlet blocked

Remove the obstacles

Running but not Air outlet blocked Remove the obstacles

heating

3minutes protection Wait patiently

Set temp too low Set proper heating temperature

If the above solution doesn’t work, please contact your dealer or Support

Pool Products. Don’t try to repair the heater yourself.

22

Failure code

NO. Display

Not failure description

1

E3 No water protection

2

E5 Power supply excesses operation range

3

E6

Excessive temp difference between inlet and outlet water(Insufficient water flow protection)

4

Eb Ambient temperature too high or too low protection

5

Ed Anti-freezing reminder

NO. Display

Failure description

1

E1 High pressure protection

2

E2 Low pressure protection

3

E4 Phases lack protection (three phase model only)

4

E7 Water outlet temp too high or too low protection

5

E8 High exhaust temp protection

6

EA Evaporator overheat protection (only at cooling mode)

7

P0 Controller communication failure

8

P1 Water inlet temp sensor failure

9

P2 Water outlet temp sensor failure

10

P3 Gas exhaust temp sensor failure

11

P4 Heating (Evaporator)coil pipe temp sensor

12

P5 Gas return temp sensor failure

13

P6 Cooling (Titanium heat exchanger) coil pipe temp sensor

14

P7 Ambient temp sensor failure

15

P8 Cooling plate sensor failure

16

P9 Current sensor failure

17

PA Restart memory failure

18

F1 Compressor drive module failure

19

F2 PFC module failure

20

F3 Compressor start failure

21

F4 Compressor running failure

22

F5 Inverter board over current protection

23

F6 Inverter board overheat protection

24

F7 Current protection

25

F8 Cooling plate overheat protection

26

F9 Fan motor failure

27

Fb Capacitor no charging protection

28

FA PFC module over current protection

23

XIII. Wi-Fi Setting 1.APP Download

Android Mobile please download from

iPhone please download from

2.Account registration a) Registration by Cell phone number/Email

24

b) Cell phone number registration
3.Create family Please set a name for the family and choose the room of the device.
25

4.Three methods of device binding Please connect your phone to the Wi-Fi network first.

4.1.Auto Discovery (Bluetooth)
a) Please make sure the Bluetooth function is enabled on your phone.

b) Press

for 3 seconds after the screen unlock,

will be flashing rapidly to enter Wi-Fi binding status. c) Click “Add Device”, wait for the app to search for the
device and then click “add”, then follow the instructions below to finish the device binding.

26

Note: (1). It will take some time to scan, please be patient. (2). Only Wi-Fi modules with Bluetooth functions can use this method.

4.2.EZ Mode (Easy-connect) a) Activate the Wi-Fi module

Press

for 3 seconds after the screen unlocks,

will be flashing rapidly to enter Wi-Fi binding status. b) Click “Add device”, and follow the instructions below to

finish binding.

display on the screen once the Wi-

Fi connection success.

27

Note: After allowing the APP to locate, it can read the Wi-Fi name automatically.
28

4.3.AP Mode Activate Wi-Fi module

a) Press

for 10 seconds after the screen unlock,

will be flashing slowly to enter Wi-Fi binding
status. b) Click “Add device”, and follow the instructions below

to finish binding.

display on the screen once the

Wi-Fi connection success.

Note: If it doesn’t jump automatically, click “Confirm hotspot connection, next”.
29

4.4.If connect fails, please make sure your network name and password are correct. And your router, mobile phone and device are as close as possible.

4.5.Wi-Fi rebinding (When Wi-Fi password changes or network configuration changes)

Press

for 10 seconds,

will be flashing slowly for 60

seconds. Then

will be off. The original binding will be

removed. Follow steps above for rebinding.

Remarks: Please make sure the router is configured at 2.4 GHz.

30

5.Operation instructions The following instructions are for heat pumps with heating and cooling functions.
More share device Heating capacity percentage Indicate the working status The current swimming pool water temp Switching °C/°F Setting temp Temp adjustment slider Smart/Silence Selection Cloud Timer Heating/Cooling/Auto Selection ON/OFF
31

6. Share devices with your family members After binding, if your family members also want to control the device. Please let your family members register the APP first, and then the administrator can operate as below (The following pictures are for reference only):
Then your family members will see this heat pump once they log in to the APP. Notice: (1). The weather forecast is just for reference. (2). APP is subject to update without notice.
The factory reserves the final interpretation right. And keep the right to stop or change product specification and design without prior notice at any time, no need to bear the resulting obligations.
32

XIV. Warranty & After-Service
1HVAC products warranty is managed by Moov Pool Products. Please note 1HVAC products are not a brand owned by Moov Pool Products. Only 1HVAC products listed above are managed by Moov Pool Products. Warranty begins at time of purchase. Warranty is only valid upon first install.
Some claims will not be approved under any circumstances by Moov Pool Products. Such claims include and are not limited to:
– Heat Exchanger broken due to water left in through unproper winterization. Appropriate winterization can be found on page 15 of this manual. Any other winterization default claims will be refused.
– Heat Pump damaged by meteorological events such Hurricanes, Tornados, Hail, Earthquakes and any other act of god event.
– Units not installed by an appropriate technician. The trade job of these technicians will vary depending on the region of the install and can include 1HVAC technicians or electricians. Electrical wiring or product manipulations are included.
– Any unsatisfactory claim. Heat Pumps efficiency will vary depending on various factors such as outdoor temperature, required temperature, air flow, sun presence, humidity, pool sizing, heat pump distance from the pool and much more. Please always refer to your pool expert to select the right unit tailored to your needs or contact Moov Pool Products for a recommendation.
All warranty claims must be approved by an authorized Moov Pool Products employee. For more information on warranties or to submit a claim, contact Moov Pool Products.
Moov Pool Products Inc Head office located in Orlando, Florida, USA
www.moovpool.com / (407)-559-2077
The factory reserves the final interpretation right and keep the right to stop or change product specification and design without prior notice at any time, no need to bear the resulting obligations.
33

Version:GFL113I1HVAC

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals