Premier1Supplies SnailStop Electric Fence Owner’s Manual
- August 26, 2024
- Premier1Supplies
Table of Contents
- Premier1Supplies SnailStop Electric Fence Owner’s Manual
- 1. General
- 2. Correct use
- 3. Safety instructions
- 4. Scope of delivery
- 5. Optional accessories / replacement articles
- 6. Setup of the system (functional principle)
- 7. Installation
- 8. Operation
- 9. Operating multiple tences with one power unit
- 10. Cleaning and maintenance
- 11. Maintenance and repair
- 12. Errors and possible solutions
- 13. Technical data
- 14. Disposal
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Premier1Supplies SnailStop Electric Fence Owner’s Manual
1. General
When installed correctly, the electric slug fence forms an insurmountable barrier for all kinds of slugs in the home garden. Due to the low fence voltage of 9 V (block battery), the slugs do not suffer any damage, but merely feel an unpleasant tingling sensation and are immediately induced to turn around. For other animals and also for humans, the effect is not noticeable and completely harmless.
2. Correct use
This product, along with its accessories, are intended solely for scaring off
slugs. It has no other intended use.
Technical modifications to the system or its components are not permitted!
3. Safety instructions
- Check the system on a regular basis for damage. Replace any damaged components if necessary!
- Stow loose cables in order to prevent trips or other injuries!
- Regularly check the battery status and dispose of any leaking or damaged batteries properly without delay!
- The power unit may only be operated with a 9 V battery. Mains operation is not permitted.
4. Scope of delivery
5. Optional accessories / replacement articles
6. Setup of the system (functional principle)
The fence tape has two parallel, electrically conductive contact strips. During operation, one of the contact strips is placed under 9 V voltage for a short period of time (a few milliseconds) at regular intervals (approx. 2 seconds).
The slug’s slimy, wet surface means that it is particularly good at conducting electricity. If the stug makes a connection between the two contact strips when trying to cross the fence tape, a small current flows for a short time. The slug is not harmed by this, but merely finds the flow of electricity unpleasant and changes direction.
For humans and animals, the current and voltage of the battery are too small
to feel.
Operation is completely harmless.
It is possible to supply up to three separate fence sections with just one power unit (see Section 9 Operating multiple fences with one power unit).
7. Installation
7.1. Preparations before installation
Ambient conditions
Where possible, maintain a sufficient distance from the soil in order to avoid
dirtying the fence or prevent plants growing over it. In the case of raised
beds, we recommend installation in the upper third. Always ensure that plants
do not come into contact with the fence tape. This can have a negative
influence on its function.
Surface:
Before installing the fence tape, note the following points in order to ensure
maximum adhesion of the fence tape:
-
The substrate should be as free from dust and dirt as possible: if necessary, dean and allow the substrate to dry well before installation.
-
Substrate free from greases and oils: clean any contamination of the substrate with a grease-dissolving substance.
Metal surfaces particular are often oiled or greased! -
Important: The fence tape’s adhesion may be impaired on timber that has recently been treated with oil. Wait a few weeks until the oil has been largely absorbed before installing the fence tape.
Fence connection:
Before attaching the fence tape, the positions of the retaining plates on the
power unit and any bed connector used must be selected (the retaining plate is
installed at the same time as the fence tape is stuck on).
7.2. Installing the fence tape
Sticking on the fence tape and attaching the retaining plates
Be aware that the fence tape should never be attached to flat, but rather onto
vertical surfaces. Otherwise, the rain water cannot run off and will cause a
short circuit. The self-adhesive fence tape can be easily and permanently
attached to almost all types of surface (wood, metal, plastic, stone,
concrete) and can be shortened if necessary with household scissors.
Extending the fence tape
If necessary, the fence tape can be extended using 10 m fence tape (item
291128) or 20 m fence tape (item 291129) and fence tape connector (item
291127).
These items are not included in the scope of delivery and are available as
accessories.
To do this, proceed as follows:
TIP: If you wish to test whether any point of the fence is working, proceed as
follows: use a metallic object (e.g. nail, screwdriver or similar) to bridge
the two contact strips cn the tape at the point
you wish to check for at least 10 seconds.
At the same time, check the power unit:
a. If the fence status LED starts to flash red after 10 seconds, the fence’s
function at this pcsrt rs CW
b. If there is no indication (or if the fence status LED flashes green when
the test button ts presses, then there is no end-to-end electrical connection
to the fence. Check all of the contact points and carry cut the test again.
The entire fence does not need to form a loop. The open ends do not need to be connected ether, however it does increase the reliability. Excess fence tape can simply be cut off with household scissors.
Practical tip: For this reason, you can also use the electric slug fence to protect lawn edges from slugs without forminn a loon with the fenn
Take care to ensure that the cut enos 00 nol cause a short circuit. This is especially relevant for metallic substrates. To do this, remove a niece of the two conductive aluminium strips from the backinq material at the ends (approx. 2 mm).
7.3. Connecting the power unit
8. Operation
8.1. Switching the power supply on
Inserting the battery causes the device to be automatically activated and
ready for operation.
9. Operating multiple tences with one power unit
If necessary, multiple separate fences can be connected to one bed connector
(item 291126) and therefore operated with a single power unit.
This is useful, for example, if separate, adjacent beds are to be fenced off.
The power unit is connected to one bed. A further bed is connected and
supplied with power using the bed connecto (item 291126).
The bed connector consists of two contact clips linked by a cable and two
retainjng plates. The retaining plates and the contact clips are installed as
described in Section 7.2 and 7.3. please always note the maximum permissible
fence length of 30 m. Beyond this length, the effect of the fence can be
reduced and the battery service life can also be significantly shortened.
10. Cleaning and maintenance
10.1. Removing slug slime
In the event of heavy slug attacks, slime can build up on the fence tape. This
can influence the function of the fence and, at high concentrations, can have
a negative impact on the battery service life. Remove softened slime only in
wet weather with a wet sponge or cloth. Never scratch off dried slime since
this can damage the metal conductor in the fence tape.
10.2. Removing plants
Plant growth (grass, leaves, etc.) can form electrical bridges and have a
negative impact on the fence’s function. Slugs can also use parts of plants as
“ladders” to overcome the fence. You should therefore regularly cut back any
such plant growth
11. Maintenance and repair
11.1. Changing the battery
When the battery level is low, the 9 V block battery must be replaced. When
replacing the battery, ensure that the cover is repositioned and screwed on
correctly in order to ensure the housing’s leak tightness.
12. Errors and possible solutions
12.1. Parts of the fence or the entire fence are overcome by slugs
Check all of the contact pctnts to ensure they are continuous. Carry out the
test described in 7.2 to localise the faulty area
12.2. The LED fence indicator flashes red constantly
There is a short circuit in the fence tape (both contact strips have been
bridged, for example by a metallic foreign body or due to incorrect of the
components). Check the installation to eliminate the short circuit.
13. Technical data
- Operating voltage: 9 V
- Battery service life: approx. 6 months (for a 10 m fence length, without plant growth)
14. Disposal
Electronic scrap
Disposing of this device after its service life is the responsibility of the
operator. Please consult the valid national regulations. The device must not
be disposed of in househo!d waste. In accordance with the stipulations of the
EU Directive on the Disposal of Electrical and Electronic Devices, the device
can be disposed of free of charge at the local waste cr recycling centre.
Alternatively.it can be returned to retailers who offer a collection service.
The proper disposal helps to ensure—environmental orotection and orevents anv
adverse effects on human health and the environment.