NEXCOM nDAS6000 Series Remote Data Acquisition System Owner’s Manual
- August 21, 2024
- NEXCOM
Table of Contents
NEXCOM nDAS6000 Series Remote Data Acquisition System
Product Information
Specifications:
- Product Name: nDAS6000 Series
- Models: nDAS6017(8AI), nDAS6051(16DI), nDAS6050(8DI8DO), nDAS6056(16DO)
- Features: AI, DI, DO functionalities
- Network Interface: RS485, WLAN
- Default IP Address: 192.168.0.1
Product Usage Instructions
Caution:
When connecting jumper wires or installing cards, it is advisable to
disconnect the power source to prevent power surges from damaging sensitive
electronic components.
Application Wiring for nDAS6017(8AI):
- Switch settings: current mode ON, voltage mode OFF
- Wiring connections:
- D+ DI.GND connected to pins 4-21
- RS485+ RS485RS485_GND AI_P0 AI_N0 AI_P1 AI_N1 AI_P2 AI_N2 A_GND AI_P3 AI_N3 AI_P4 AI_N4 AI_P5 AI_N5 A_GND AI_P6 AI_N6 AI_P7 AI_N7
Network Initial Setting:
- DIP 1 ON
- DIP 2 default status is OFF. Switch DIP 2 to ON and repower on nDAS for WLAN to be set to AP mode.
- Default IP address for nDAS AP mode: 192.168.0.1
Access the web UI of nDAS:
- DIP 2 ON
- Use a web browser and enter the IP address (192.168.0.1) of the nDAS.
- Login with username: admin, password: 123456 to configure settings, monitor I/O status, and operate nDAS.
FAQ:
- Q: What should I do if I forget the login password for nDAS?
A: You can perform a password reset by following the instructions in the user manual or contacting customer support for assistance.
Caution
When connecting jumper wires or installing cards, it is advisable to
disconnect the power source to prevent power surges from damaging sensitive
electronic components.
Application Wiring
nDAS6017(8AI)
nDAS6050(8DI8DO)
nDAS6051(16DI)
nDAS6056(16DO)
Network Initial Setting
- nDAS requires 9~30VDC power supply. There are 3 pins for nDAS power.
- nDAS supports HTML5 so that PCs in the same network domain with nDAS can connect to it and operate it through web browser.
- There are 2 DIP switch on nDAS for network initial settings.
- DIP1 is for LAN and DIP2 is for WLAN.
- DIP1 default status is OFF, and IP address setting of the two LAN is DHCP.
- Switch DIP 1 to ON and re power on nDAS, then the two LAN port of nDAS will be set to initial IP.
- LAN1 initial IP is 11.0.0.1, and LAN2 initial IP is 10.0.0.1
- DIP2 default status is OFF, and the mode of WLAN follows system setting.
- Switch DIP 2 to ON and re power on nDAS, then the WLAN will be set to AP mode.
- The default IP address of nDAS AP mode is 192.168.0.1
- Use web browser and enter the IP address of the nDAS, then we can see the web UI of nDAS.
- Click on Login button to config the nDAS settings, monitor I/O status, and operate nDAS further.
- The login username is admin. Its default password is 123456.
Read User Manual Online (PDF format)