AlgoForce E1500 Gold Detector User Guide

August 8, 2024
AlgoForce

AlgoForce E1500 Gold Detector

Specifications

  • Product Name: AlgoForceTM E1500
  • Technology: Ultra-Fine Pulse Induction with VLF Sensitivity and PI Power
  • Origin: Designed & Assembled in Australia by ALGOFORCE PTY LTD

FAQs

  • Q: How do I adjust the audio volume on the AlgoForceTM E1500?
    • A: Press the Vol/Vibration buttons to modify the Audio Volume. Hold the Vol/Vibration buttons to adjust Vibration.
  • Q: Where is the AlgoForceTM E1500 designed and assembled?
    • A: The AlgoForceTM E1500 is designed and assembled in Australia by ALGOFORCE PTY LTD.

Assembly

  1. Plug the USB cable into the control box.
  2. Secure the control box to the shaft using two M5 screws.
  3. Attach the armrest to the sliding rail.
  4. Secure the power bank with the straps.
  5. Connect the USB cable to the power bank.
  6. Set the shaft to the appropriate length and attach the coil.
  7. Plug the coil connector into the control box.
  8. Tie the coil cable and USB cable to the shaft using the cable straps.

Quick Start

Press the Vol/Vibration buttons to modify the Audio Volume. Hold the Vol/Vibration buttons to adjust Vibration. Press the Backlight Adjust button for backlight control. Use the Minus and buttons to modify Sensitivity.

To adjust other settings:

  1. Press Right/Auto GB in the Main Detection UI to access the menu.
  2. Navigate with Left/Pinpoint or Right/Auto GB.
  3. Modify the selected setting with Minus or Plus.
  4. Press Return/Auto FS to go back to the Main Detection UI.

PRODUCT INFORMATION

  1. Power On
    • Connect the power bank to the control box and turn it on. To power the detector, hold the Power On/Off button for 3 seconds, then release it. Repeat to turn it off.
  2. Factory Reset (if necessary)
    • Hold the Minus and buttons for 3 seconds in Miscellaneous.
  3. Calibrate Coil (if installing a new coil)
    • In Coil Selection, select the coil icon to save calibration data. Modify the Coil Size if needed (hold Return/Auto FS to enter edit mode). Raise the coil 1 meter away from metal and soil.
    • If the LCDs “Hold ⊖ + ⊕ to calibrate,” hold the Minus and buttons until calibration starts. Calibration takes 25 seconds. Keep the coil in the air throughout. The LCD shows “Coil Ready” when done.
  4. Perform Auto Frequency Scan (Auto FS) (if necessary select the quietest frequency to eliminate electromagnetic interference)
    • Activate Auto FS by holding the Return/Auto FS button in the Main Detection UI.
    • The Auto FS process takes 50 seconds.
  5. Set Sensitivity, Audio Settings, and Vibration (to preferred levels)
    • Adjust Sensitivity, aligning the Real-time Scrolling Detection Signal peak with the
    • Detection Threshold in the absence of a target.
  6. Perform Auto Ground Balance (Auto GB) (to eliminate ground response)
    • Hold the Right/Auto GB button. Raise and lower the coil until the ground response is minimized or two short beeps are heard, then release the button.
  7. Begin Detecting
    • Keep the coil close to the ground and swing left and right at a pace of about 1 m/s.
  8. Pinpoint detected target (if needed)
    • Enter the Pinpoint UI by pressing the Left/Pinpoint button in the Main Detection UI. Return to the Main Detection UI by pressing the Return/Auto FS button.

PRODUCT FUNCTIONS

  1. Sensitivity
  2. Audio Threshold
  3. Audio Tone
  4. Audio Treble
  5. Soil Type
  6. Detection Mode
  7. Frequency Scan
  8. Coil Selection
  9. Real-time Scrolling Signal
  10. Ground Drift Indicator (G.D.I)
  11. Dual Ground Balance Values
  12. Backlight Level
  13. High Tone Signal Strength
  14. Soil Mineralisation
  15. Low Tone Signal Strength
  16. Vibration Level
  17. Audio Volume Level
  18. Selected Coil Size
  19. Auto GB In Progress Indicator
  20. Detection Threshold

Button Functions

  1. Power On/Off
  2. Backlight Adjust
  3. Minus
  4. Plus
  5. Vol/Vibration ↓
  6. Vol/Vibration ↑
  7. Left/Pinpoint
  8. Return/Auto FS
  9. Right/Auto GB

Scan the QR code for the user manual

Caution: AlgoForce E1500 is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.

Uncover Gold with Ultra-Fine Pulse Induction Technology: VLF Sensitivity, PI Power, Affordable Excellence! Designed & Assembled in Australia by ALGOFORCE PTY LTD.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals