AlgoForce E1500 Gold Dedecter User Guide
- June 16, 2024
- AlgoForce
Table of Contents
AlgoForce E1500 Gold Dedecter
Important Instructions
Uncover Gold with Ultra-Fine Pulse Induction Technology:
VLF Sensitivity, PI Power, Affordable Excellence! Designed & Assembled in
Australia by ALGOFORCE PTY LTD
Assembly
- Attach the USB cable to the control box and secure it to the stem.
- Attach the arm cuff to the sliding rail, secure the power bank with the straps and connect the USB cable.
- Set the rods to the appropriate length and attach the coil.
- Plug the coil connector into the control box.
- Tie the coil cable and USB cable to the stem using the cable straps.
Quick Start
Press Vol/Vibration buttons to modify Audio Volume. Hold Vol/Vibration buttons
to adjust Vibration. Press the Backlight Adjust button for backlight control.
Use the
Minus and Plus buttons to modify Sensitivity. To adjust other settings:
- Press Right/Auto GB in the Main Detection UI to access the menu.
- Navigate with Left/Pinpoint or Right/Auto GB.
- Modify selected setting with Minus or Plus.
- Press Return/Auto FS to go back to the Main Detection UI.
I. Power On
Connect the power bank to the control box and turn it on. To power the
detector, hold the Power On/Off button for 3 seconds, then release. Repeat to
turn it off.
II. Factory Reset (if necessary)
Hold the Minus and Plus buttons for 3 seconds in Miscellaneous.
III. Calibrate Coil (if installing a new coil)
In Coil Selection, select the coil icon to save calibration data. Modify the
Coil Size if needed (hold Return/Auto FS to enter edit mode). Raise the coil 1
meter away from metal and soil. If the LCD displays “Hold ⊖ + ⊕ to calibrate,”
hold the Minus and Plus buttons until calibration starts. Calibration takes 25
seconds. Keep the coil in the air throughout. The LCD shows “Ready to detect”
when done.
IV. Perform Auto Frequency Scan (Auto FS) (if necessary to select the
quietest
frequency to eliminate electromagnetic interference) Activate Auto FS by
holding the Return/Auto FS button in the Main Detection UI. The Auto FS
process takes 50 seconds.
V. Set Sensitivity, Audio Settings, and Vibration (to preferred levels)
Adjust Sensitivity, aligning the Real-time Scrolling Detection Signal peak
with the Detection Threshold in the absence of a target.
VI. Perform Auto Ground Balance (Auto GB) (to eliminate ground response)
Hold the Right/Auto GB button. Raise and lower the coil until the ground
response is minimized or two short beeps are heard, then release the button.
VII. Begin Detecting
Keep the coil close to the ground and swing left and right at a pace of about
1 m/s.
VIII. Pinpoint detected target (if needed)
Enter the Pinpoint UI by pressing the Left/Pinpoint button in the Main Detection UI. Return to the Main Detection UI by pressing the Return/Auto FS button.
Main Detection UI
- Sensitivity
- Audio Threshold
- Audio Tone
- Frequency Scan
- Detection Mode
- Mic Volume
- Coil Selection
- Miscellaneous
- Real-time Scrolling Signal
- Ground Drift Indicator (G.D.I)
- Dual Ground Balance Values
- Backlight Level
- High Tone Signal Strength
- Soil Mineralisation
- Low Tone Signal Strength
- Vibration Level
- Audio Volume Level
- Selected Coil Size
- Auto GB In Progress Indicator
- Detection Threshold
Button Functions
- Power On/Off
- Backlight Adjust
- Minus
- Plus
- Vol/Vibration ↓
- Vol/Vibration ↑
- Left/Pinpoint
- Return/Auto FS
- Right/Auto GB
Scan the QR code for the user manual
Caution: AlgoForce E1500 is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>