LG LW1512ER Air Conditioner Instruction Manual
- July 31, 2024
- LG
Table of Contents
- LW1512ER Air Conditioner
- Product Information
- Specifications:
- Before Operation
- Tools Needed for Installation:
- Location Requirements:
- Window Installation:
- Assemble Curtain/Top Rail:
- Positioning the Air Conditioner:
- Q: Can I use an extension cord with the air conditioner?
- Q: What tools are needed for installation?
LW1512ER Air Conditioner
“`html
Product Information
Specifications:
-
Model: LG LW1812ER
-
Cooling Capacity: 14500-24000 BTU
-
Weight: 100 lbs to 130 lbs (45.4 kg to 59.0 kg)
-
Window Opening Dimensions:
-
14500-18000 BTU: Min A(inch) 28, Max A(inch) 38, Min B(inch)
17 -
24000 BTU: A(inch) and B(inch) dimensions not specified
-
Product Usage Instructions
Before Operation
Make sure all parts are included in the package:
- Top rail
- Foam seal
- Installation brackets (left and right)
- Window lock bracket
- Screws
- Bracket screws
- Locknut
- Left and right side curtains
- Remote control
Tools Needed for Installation:
- Phillips head screwdriver
- Flat-blade screwdriver
- Scissors
- Level
- Tape measure
- Cordless drill and 1/8 bit
- Pencil
- Pliers
- Socket wrench and sockets
- Adjustable wrench
Location Requirements:
Ensure the installation location meets the following
criteria:
-
Grounded electrical outlet within 4 ft of the air conditioner’s
power cord exit point -
Adequate air movement in the room
-
Sufficient space for air conditioner installation
-
Adequate wall support for the air conditioner’s weight
Window Installation:
Detailed steps to install the air conditioner in a window:
- Measure the width of the window opening
- Mark the center line on the inside windowsill
Assemble Curtain/Top Rail:
-
Install top rail with screws
-
Attach curtains to the air conditioner before placing it in the
window -
Fasten curtain retainer strips to the sides of the outer case
with screws
Positioning the Air Conditioner:
Handle the air conditioner gently and ensure proper positioning
without blocking louvers.
Frequently Asked Questions (FAQ):
Q: Can I use an extension cord with the air conditioner?
A: No, a grounded electrical outlet within 4 ft of the power
cord exit is required. Do not use an extension cord.
Q: What tools are needed for installation?
A: Tools required include a Phillips head screwdriver,
flat-blade screwdriver, scissors, level, tape measure, cordless
drill with 1/8 bit, pencil, pliers, socket wrench and sockets, and
an adjustable wrench.
“`
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
LG LW1812ER Owner’s Manual
Shop genuine replacement parts for LG LW1812ER
Find Your LG Air Conditioner Parts – Select From 2328 Models ——– Manual
continues below ——–
LW1512ER,LW1812ER,LW2412ER
0010539272
Before Operation
7
NOTE: Your air conditioner may differ from the one shown. REMOTE CONTROLLER
Parts supplied:
Check that all parts are included in parts package.
A B
C
D
GH
E
F
I
J
A. Top rail B. Foam seal C. Installation brackets (left and right) D. Window
lock bracket
E. 14500-18000 BTU: ” screws (12)
24000 BTU: ” screws (10) F. ” bracket screws (6) G. 14500-18000 BTU: ” screws
(8)
24000 BTU: ” screws (10)
locknut(2)
I. Left and right side curtains
J. Remote control
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed
Phillips head screwdriver Flat-blade screwdriver Scissors Level
Tape measure Cordless drill and 1/8″ bit Pencil Pliers
Socket wrench and sockets Adjustable wrench
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation.
The location should provide:
A
Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner. Installation parts are
supplied for double-hung windows.
Adequate wall support for weight of air conditioner. Air conditioner weighs
100 lbs to 130 lbs (45.4 kg to 59.0 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.
A. Cabinet louvers
Window Installation
Window opening measurements:
MODEL
Dimension
A(inch) Min A(inch) Max B(inch) Min
14500-18000 BTU
28 “(72.1cm) 38″(96.5cm) 17 “(44.1cm)
24000 BTU
31¼”(79.4cm) 40″(101.6cm) 20¼”(51.4cm)
A B
A. Width B. Height
Unpack the Air Conditioner
Remove Packaging Materials
NOTE:The air conditioner must set upright for one hour before operating.
Remove and dispose of/recycle packaging materials. Remove tape and glue
residue from surfaces before turning on the air conditioner. Rub a small
amount of liquid dish soap over the adhesive with your fingers.Wipe with warm
water and dry. Do not use sharp instruments,rubbing alcohol, flammable
fluids,or abrasive cleaners to remove tape or glue.These products can damage
the surface of your air conditioner. Handle the air conditioner gently.
Prepare Air Conditioner for Installation
Unpack unit on the floor next to installation location. 1. Remove two front
attachment screws.Separate the outer case from the front with a putty knife at
the catch points designated by the arrows. 2.14500-18000 BTU:Remove the four
screws on both sides of the outer case. 24000 BTU:Remove the two screws on
both sides of the outer case. 3.Using the basepan handle, slowly and evenly
pull chassis out from outer case. NOTE: Cover putty knife blade with masking
tape to guard against damage of the unit finish. CAUTION:Never expose plastic
front or grille to extreme temperatures.
Assemble Curtain/Top Rail
NOTE:Attach curtains to the air conditioner before placing the air conditioner
in window.
1.Install top rail with four 13/32″ screws. 2.Slide left-hand curtain assembly
into left end of top and bottom rails. Repeat for right-hand curtain assembly.
3.14500-18000 BTU:Fasten curtain retainer strips to the sides of the outer
case with eight 13/32″ screws. 24000 BTU:Fasten curtain retainer strips to the
sides of the outer case with six 13/32″ screws.
AB
C D A. Top channel C. 13/32″ screws B.13/32″ screws D. Side curtains
Prepare the Window for Installation
1. Measure the width of the window opening. 2. Mark the center line on the
inside windowsill.
A. Width of window opening B. Center line
Positioning the Air Conditioner
A B
NOTES: Handle the air conditioner gently. Be sure your air conditioner does
not fall out of the opening during installation or removal. The place where
the power cord exits the air conditioner should be no more than 4 ft (122 cm)
from a grounded outlet.
Do not block the louvers in the front panel.
Do not block the louvers on the outside of the air conditioner.
B
A C
A. Side curtain against window channel B. Window sash behind top channel C.
Bottom channel in behind windowsill NOTE: Your model may differ from the one
shown.
Install Outer Case in Window
1.Place outer case in window. Lower sash until it rests behind front flange of
top rail.Bottom rail must rest behind window sill.
NOTE: To make screws easier to drive, drill a pilot hole into the sash through
clearance hole in curtains. NOTE: Tilt the outer case about 1/2″ down towards
the outside for proper condensate water drainage.
5.Install left&right installation bracket and as shown in fig.Install
bolt(2-1/2″ long flat head bolt and locknut) to the installation bracket and
adjust them to proper length,then use 6(13/32″)screws to fix the bracket on
the case.
2.Expand both curtains to contact the window frame. Install four wood screws
31/32”. Two in each upper right and left of the curtains.
3.24000 BTU: Install three wood screws 31/32″ in the top mounting channel.
3.24000 BTU: Install three wood screws 31/32″ in
the top mounting channel.
6.Use a wood block between the leveling bolts and
4.Use three wood screw 31/32″ to fix the case to windows the wall if the wall is weak or if the weight of the air
sash.
14500-18000 BTU:
conditioner falls between the studs in the wall.
24000 BTU:
Completing the Installation
1.Insert the foam seal behind the top of the lower window sash and against the
glass of the upper window.
A
B
A. Top of lower window sash B. Foam seal
2.Place the window lock bracket as shown. Use a 1/8″ drill bit to drill a starter hole through the hole in Note:For security purposes, reinstall screws the window lock bracket and into the upper window. at cabinet’s sides, removed at the beginning.
3.Attach the window lock bracket to the upper
IMPORTANT:Because the window sash helps
window with one 31/32″ screw to secure the window keep the unit in window, make certain the
in place.
window sash contacts the outer case before
reinstalling the chassis.
Return Chassis to the Outer Case
1.Plug into a grounded 3 prong outlet. 2.Press RESET on the power supply cord. See “Electrical Requirements.”
Find someone to help you replace the chassis in outer case.Replace front panel and grille.
REMOTE CONTROLLER
POWER
Operation starts when this button is pressed and stops when you press the
button again.
FAN SPEED SELECTOR
For increased power while cooling,select a higher fan speed. 3 steps:High Med
Low.
ON/OFF TIMER
a. Press TIMER.Timer OFF indicator light will flash .Display will show
remaining hours before the air conditioner will turn off. b. Press the
TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24
hours. c. After 5 seconds, Timer OFF indicator light will remain on.Display
will show the current room temperature.
OPERATION MODE SELECTOR
a. Press MODE until you see the indicator light glow for the desired setting.
b. Choose Fan, Cool, Energy Saver or Dehum.
Fan–Only the fan runs. Press SPEED to select High, Med or Low fan speed. The
display shows the current room temperature. Cool–Cools the room. Press SPEED
to select High, Med or Low fan speed. Press the TEMP/TIME up or down arrow
button to adjust the temperature. Energy Saver–Fan runs only when cooling is
needed.Press SPEED to select High, Med or Low fan speed.Because the fan does
not circulate the room air continuously, less energy is used, but the room air
is not circulated as often. Dehum–Dries the room. The air conditioner
automatically selects the temperature. Fan runs on Low speed only.
TEMPERATURE CONTROL
Press the TEMP/TIME up arrow button to raise the temperature. Each time you
press or hold the TEMP/TIME uparrow button, the temperature will go up 1ºF
until it reaches 86°F (30°C).
Press the TEMP/TIME down arrow button to lower the temperature. Each time you
press or hold the TEMP/TIME down arrow button, the temperature will go down
1ºF until it reaches 61°F (16°C).
REMOTE CONTROL SENSOR
CAUTION
The Remote Controller will not function properly if strong light strikes the
sensor window of the air conditioner or if there are obstacles between the
Remote Controller and the air conditioner. NOTE: One CR2025 battery (included)
powers the remote control. Replace battery after 6 months of use, or when the
remote control starts to lose power.
Power
Press ON/OFF to turn on the air conditioner.
Mode
Press MODE to choose Fan, Cool,Energy saver or Dehum.
Speed
Press SPEED to choose High, Med or Low.
Temperature
Press the TEMP/TIME up arrow button to raise the temperature. Each time you
press or hold the TEMP/TIME up arrow button, the temperature will go up 1ºF
until it reaches 86°F (30°C). Press the TEMP/TIME down arrow button to lower
the temperature. Each time you press or hold the TEMP/TIME down arrow button,
the temperature will go down 1ºF until it reaches 61°F (16°C).
Timer
To set the Timer for a 1-hour to 24-hour delay before the air conditioner is
turned off (the air conditioner must be On):
1. Press TIMER. TLPHU2))LQGLFDWRUOLJKWRQWKHDLUFRQGLWLRQHUFRQWUROSDQHOZLOOÀDVK
2. Press the TEMP/TIME up or down arrow button to change the delay time from 1
hour
to 24 hours.
3. After 5 seconds, Timer OFF indicator light on the air conditioner control
panel will remain on.
To set Timer to turn on the air conditioner, keeping previous settings:
1. Turn on the air conditioner.
Press TIMER. TLPHU2QLQGLFDWRUOLJKWRQWKHDLUFRQGLWLRQHUFRQWUROSDQHOZLOOÀDVK
Press the TEMP/TIME up or down arrow button to change the delay time from 1
hour to 24 hours.
After 5 seconds, Timer On indicator light on the air conditioner control panel
will remain on.
To set Timer to turn on the air conditioner, changing the previous settings:
1. Turn on the air conditioner. 2. Adjust the mode to Fan or Cool.
3. For Fan, Cool or Energy Saver mode, adjust the fan speed to High, Med or
Low.
4. Adjust the temperature between 61ºF and 86ºF (16ºC and 30ºC). NOTE: In Fan
mode, the temperature cannot be set.
5. Press TIMER. Timer On indicator light on the air conditioner before the
air conditioner will turn on.
6. Press the TEMP/TIME up or down arrow button to change the delay time from
1 hour to 24 hours. 7. Timer On indicator light on the air conditioner control
panel will remain on.
To clear Timer delay program:
NOTE: Air conditioner can be either on or off.
1. Press TIMER once after it has been programmed. Display on the air
conditioner control panel will show remaining time.
2. While the display is showing the remaining time, press TIMER untill Timer
indicator light turns off.
To see or change the remaining time (in hours):
Timer Off : 1. Press TEMP/TIME once after it has been programmed.Display on
the air conditioner control panel
will show remaining time. 2. While the display is showing the remaining time,
press the TEMP/TIME up or down arrow button
to increase or decrease the time. 3. After 5 seconds, the display on the air
conditioner control panel will show the current room
temperature. Timer On : 1. Display on the air conditioner control panel will
show remaining time. 2. While the display is showing the remaining time, press
the TEMP/TIME up or down arrow button to
increase or decrease the time.
4-Way Air Flow:The air directional louvers let you control the direction of
the airflow to the desired direction .The airflow can be directed up-down
,left-right.
Vent:The fresh air vent allows the air conditioner to recirculate inside
air,draw fresh air into the room and exhaust stale air to the outside.
14500-18000 BTU:
24000 BTU:
4-way Air Flow The Fresh air vent
4-way Air Flow The Fresh air vent
Normal Sounds
When your air conditioner is operating normally, you may hear sounds such as:
Droplets of water hitting the condenser, causing a pinging or clicking sound.
The water droplets help cool the condenser. Air movement from the fan. Clicks
from the thermostat cycle. Vibrations or noise due to poor wall or window
construction. A high-pitched hum or pulsating noise caused by the modern
Your new air conditioner is designed to give you many years of dependable
service. This section tells you how to clean and care for your air conditioner
properly.
Cleaning the Air Filter
filter helps remove dust, lint, and other particles from the air and is
important for best cooling and operating efficiency.Check the filter every 2
weeks to see whether it needs cleaning.
Note:Do not operate the air conditioner without the filter in place. 1. Turn
off the air conditioner. 2. Remove the air filter by opening the front panel
and removing the air filter.
filter is very dirty, wash it in warm water with a mild detergent. Do not wash
the air filter in the
B A
B. Front panel
5. Close the front panel. 6. Turn on the air conditioner.
Cleaning the Front Panel
1. Turn off the air conditioner. 2. Clean the front panel with a soft, damp
cloth. 3. Air dry the front panel completely. 4. Turn on the air conditioner.
Annual Maintenance
Your air conditioner needs annual maintenance to help ensure steady, top
performance throughout the year. Call your local authorized dealer to schedule
an annual checkup. The expense of an annual inspection is your responsibility.
/*(/(&7521,&6,1& 6OYDQ$YH(QJOHZRRG&OLIIV1-
/*&XVWRPHU,QIRUPDWLRQ&HQWHU
5HJLVWHURXUSURGXFW2QOLQH ZZZOJDSSOLDQFHVFRP
References
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Lg Air Conditioner Parts - Select From 2329 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>