LG LMU180CE Multi Type Air Conditioner Owner’s Manual
- July 30, 2024
- LG
Table of Contents
This Owner’s Manual is provided and hosted by Appliance Factory
Parts. LG
LMU180CE
Owner’s Manual
Shop genuine replacement parts for LG
LMU180CEFind
Your LG Air Conditioner Parts – Select From 2328
Models
——– Manual continues below ——–
LG
Multi Type Air Conditioner OWNER’S MANUAL
Prior to installation, this air conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3 Norm).
IMPORTANT
- Please read this owner’s manual carefully and thoroughly before installing and operating your room air conditioner.
- Please retain this owner’s manual for future reference after reading it thoroughly.
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer’s Name
Date Purchased
■ Staple your receipt to this page in the event you need it to prove date of
purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air
conditioner properly. Just a little preventive care on your part can save you
a great deal of time and money over the life of your air conditioner.
You’ll find many answers to common problems in the chart of troubleshooting
tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for service at all.
PRECAUTION
- Contact the authorized service technician for repair or maintenance of this unit.
- Contact the installer for installation of this unit.
- The air conditioner is not intended for use by young children or invalids without supervision.
- Young children should be supervised to ensure that they do not play with the air conditioner.
- When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.
- Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.
Safety Precautions
To prevent injury to the user or other people and property damage, the
following instructions must be followed.
■ Incorrect operation due to ignoring instruction will cause harm or damage.
The seriousness is classified by the following indications.
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to properties only.
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
■ Installation
Do not use a defective or underrated circuit breaker. Use this appliance on a
dedicated circuit.
- There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
- Do not disassemble or repair the product. There is risk of fire or electric shock.
Always ground the product.
- There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
- There is risk of fire or electric shock.
Always install a dedicated circuit and breaker.
- Improper wiring or installation may cause fire or electric shock
Use the correctly rated breaker or fuse.
- There is risk of fire or electric shock.
Do not modify or extend the power cable.
- There is risk of fire or electric shock.
Do not install, remove, or re-install the unit by yourself (customer).
- There is risk of fire, electric shock, explosion, or injury.
Be cautious when unpacking and installing the product.
- Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.
For installation, always contact the dealer or an Authorized Service Center.
- There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
- It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
- If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
- Moisture may condense and wet or damage furniture.
Operation
Do not touch(operate) the product with wet hands.
- There is risk of fire or electrical shock.
Do not place a heater or other appliances near the power cable.
- There is risk of fire and electric shock.
Do not let electric parts of the product get wet.
- It may cause There is risk of fire, failure of the product, or electric shock.
Do not store or use flammable gas or combustibles near the product.
- There is risk of fire or failure of product.
If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable.
- There is risk of electric shock or fire.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
- There is risk of fire or electric shock.
Be cautious that water could not enter the product.
- There is risk of fire, electric shock, or product damage.
Turn the main power off when cleaning or maintaining the product.
- There is risk of electric shock.
When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker.
- There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
- This could result in personal injury and product damage.
CAUTION
■ Installation
Always check for gas
(refrigerant) leakage after installation or repair of product.
- Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that water is drained away properly.
- A bad connection may cause water leakage.
Keep level even when installing the product.
- To avoid vibration.
Do not install the product where the noise or hot air from the outdoor unit could be offensive to the neighborhoods or damage property.
- It may cause a problem for your neighbors.
Use two or more people to lift and transport the product.
- Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
- It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
■ Operation
Do not expose the skin directly to cool air for long periods of time. (Don’t
sit in the draft.)
- This could harm to your health.
Do not use the product for special purposes, such as preserving foods, works
of art, etc.
It is a consumer air conditioner, not a precision refrigeration system.
- There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
- It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
- There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very sharp!
- There is risk of personal injury.
Do not step on or put anything on the product. (outdoor units)
- There is risk of personal injury and failure of product.
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
- A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Do not insert hands or other objects through the air inlet or outlet while the product is operated.
- There are sharp and moving parts that could cause personal injury.
Do not drink the water drained from the product.
- It is not sanitary and could cause serious health issues.
Use a firm stool or ladder when cleaning or maintaining the product.
- Be careful and avoid personal injury.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.
- Could adversley effect operation.
Do not recharge or disassemble the batteries.
Do not dispose of batteries in a fire.
- They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
- The chemicals in batteries could cause burns or other health hazards.
If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.
- The chemicals in batteries could cause burns or other health hazards .
Prior to operation
Preparing for operation
- Contact an installation specialist for installation.
- Connect the power cable between indoor unit and outdoor unit properly.
- Use a dedicated circuit.
- If the cord/plug is damaged, replace it with only an authorized replacement part.
Usage
-
Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time. -
Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
- Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
- Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
- When cleaning the unit, first make sure that the power and breaker are turned off. There is a possibility of injury if the unit’s power is accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
Symbols Used in this Manual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the air
conditioner.
NOTICE This symbol indicates special notes.
Operating Instructions
Remote Controller
- Remove the battery cover by pulling it according to the arrow direction.
- Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
- Reattach the cover by sliding it back into position.
NOTICE Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.
Storage and Tips For Using the Remote Controller
- The remote control may be stored mounted on a wall.
- To operate the room air conditioner, aim the remote control at the signal receptor.
- The remote control will operate the air conditioner at a distance of up to 7m(23ft).
Signal Receptor
Receives the signals from the remote controller.(Signal receiving sound: two
short beeps or one long beep.)
Operation Indication Lamps
On/Off : Lights up during the system operation.
Sleep Mode : Lights up during Sleep Mode Auto operation.
Timer : Lights up during Timer operation.
Defrost Mode : Lights up during Defrost Mode or Hot Start operation
(Heat pump model only)
Outdoor unit operation : Lights up during outdoor unit operation.(Cooling
model only)
Desire temperature For cooling dehumidification heating modes it display
Destired temperature indicator
- Cooling : 18°C~30°C(64°F~86°F)
- Dehumidification : 18°C~30°C(64°F~86°F)
- Heating : 16~30°C(60°F~86°F)
- Cooling : 18°C~30°C(64°F~86°F)
- Dehumidification : 18°C~30°C(64°F~86°F)
- Heating : 16~30°C(60°F~86°F)
Plasma : The function illustrates its dynamic mode by using a multiple
lighting system.
Receives the signals from the remote controller.(Signal receiving sound: two
short beeps or one long beep.)
Operation Indication Lamps
On/Off : Lights up during the system operation.
Sleep Mode : Lights up during Sleep Mode Auto operation.
Timer : Lights up during Timer operation.
Defrost Mode: Lights up during Defrost Mode or Hot Start operation.(Heat
pump model only)
Outdoor unit operation : Lights up during outdoor unit operation.(Cooling
model only)
Desire temperature indicator • For cooling dehumidification heating modes
it display Destired temperature
- Cooling : 18°C~30°C(64°F~86°F)
- AI : Auto Operation
- Dehumidification : 18°C~30°C(64°F~86°F)
- Po : Jet Cool
- Heating : 16~30°C(60°F~86°F)
- Lo : Test Mode
PLASMA : Indicate PLASMA purifier operation.
Remote Control Operation
The Remote Controller transmits the signals to the system.
-
START/STOP BUTTON
Operation starts when this button is pressed and stops when the button is pressed again . -
OPERATION MODE SELECTION BUTTON
Used to select the operation mode. -
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature. -
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps low, medium, high and CHAOS. -
JET COOL
Used to start or stop the speed cooling/heating.
(Speed cooling/heating operates super high fan speed. ) -
CHAOS SWING BUTTON
Used to stop or start louver movement and set the desired up/down airflow direction. -
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation. -
TIME SETTING BUTTONS
Used to adjust the time. -
TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time is obtained and to cancel the Timer operation. -
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation. -
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating. -
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature. -
PLASMA(OPTIONAL)
Used to start or stop the plasma-purification function. -
RESET BUTTON
Initialize remote controller. 2nd F Button Used prior to using modes printed in blue at the bottom of buttons. -
AUTO CLEAN
Used to set Auto Clean mode. -
˚C TO ˚F SWITCHING BUTTON
Used to switch temperature reading from Centigrade to Fahrenheit. -
HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (NOT ON ALL MODELS)
Used to set the desired horizontal airflow direction.
Cooling Operation
Natural wind by the CHAOS logic
❏ For more fresh feeling, press the Indoor Fan Speed Selector and set CHAOS
mode. In this mode, the wind blows like natural breeze by automatically
changing fan speed according to the CHAOS logic.
Auto Operation
DURING AUTO OPERATION:
❏ You cannot switch the indoor fan speed. It has already been set by the Fuzzy
rule.
❏ If the system is not operating as desired, manually switch to another mode.
The system will not automatically switch from the cooling mode to the heating
mode, or from heating to cooling, then you must set the mode and the desired
temperature again.
❏ During Auto Operation, pressing the chaos swing button makes the horizontal
louvers swing up and down automatically. If you want to stop auto-swing, press
the chaos swing button again.
Healthy Dehumidification Operation
DURING HEALTHY DEHUMIDIFICATION OPERATION:
❏ If you select the dehumidification mode on the operation selection button,
the A/C starts to run the dehumidification function, automatically setting the
room temp. and air volume to the best condition for dehumidification based on
the sensed room temp.
In this case, the setting temp. is not displayed in the Remote Controller and
you are not able to control the room temp. either.
❏ During the healthy dehumidification function, the air volume is
automatically set according to the algorithm responding to the current room
temp. and makes the room condition healthy and comfortable even in the high
humidity season.
Heating Operation(Heat pump model only)
NATURAL WIND BY THE CHAOS LOGIC
❏ For more fresh feeling than other fan speed, press the Indoor Fan Speed
Selector and set to CHAOS mode. In this mode, the wind blows like natural
breeze by automatically changing fan speed according to the CHAOS logic.
Jet Cool
NOTICE
❏ Jet Cool function in heating mode is available on Artcool type only.
❏ During the JET COOL function at any moment, the A/C starts to blow the
cool/heat air at extremely high speed for 30/60 minutes setting the room temp.
automatically to 18°C/30°C(64°F/86°F). It is especially used to cool/heat the
room temperature in the shortest time.
❏ In order to return to the normal cooling/heating mode from the Jet Cool
mode, you just press either the operation mode selection button, air volume
selection or temp. setting button or the JET COOL button again.
NEO PLASMA Purification Operation(Optional)
PLASMA Air Purifying Operation only
If you press the PLASMA button, NEO PLASMA air purifying operates. Each time
the button ( **) is pressed, the fan speed mode is shifed.
2nd F Operation**
Additional features
Sleep Mode
-
Press the Sleep Mode Auto button to set the time you want the unit to turn off automatically .
-
The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times.
The sleep mode is available for 1 to 7 times.
To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner. -
Make sure the Sleep Mode Auto LED lights up.
To cancel the Sleep Mode, press the sleep Mode Auto button several times until
the star ( **) disappears from the operation display.
The Sleep Mode will be operated at low fan speed (cooling) or medium fan speed
(heat pump only) for quiet sleeping.
NOTICE
IN COOLING MODE: The temperature will automatically rise by 1°C (2°F)
over the next 30 minutes and by 2°C (4°F) in 1 hour for comfortable sleeping.
Setting the Time**
-
Time can be set only when you have pressed the Reset button. If you have just replaced the batteries, the Reset button should be pressed to reset the time.
Press the Start/Stop button . -
Press the Time Setting buttons until the desired time is set.
-
Press the Timer SET button.
NOTICE
Check the indicator for A.M. and P.M. -
Press the selected on/off setting by pressing the Timer SET button while aiming the Remote Controller at the signal receptor.
To cancel the setting the timer.
Press the Timer Cancel button while aiming Remote Controller at the signal
receptor.
(The timer lamp on the air conditioner and the display will go out.) CANCEL
NOTICE
Select one of the following four types of operation.
Vertical Airflow Direction Control
Standard, Artcool Mirror Type
The up/down airflow (Vertical Airflow) can be adjusted by using the remote
control.
Press the Start/Stop button to start the unit.
Open the door on the remote control.
Press Chaos Swing button and the louvers will swing up and down. Press the
Chaos Swing button again to set the vertical louver at the desired airflow
direction.
NOTICE
❏ If you press the CHAOS swing button, the horizontal airflow direction is
changed automatically based on the CHAOS algorithm to distribute the air in
the room evenly and at the same time to make the human body feel most
comfortable, as if enjoying a natural breeze.
❏ Always use the remote control to adjust the up/down airflow direction.
Manually moving the vertical airflow direction louver by hand could damage the
air conditioner.
❏ When the unit is shut off, the up/down airflow direction louver will close
the air outlet vent of the system.
Artcool Type
The up/down and right/left airflow can be adjusted by using the Remote
Controller.
Press the Start/Stop button to start the unit.
Press Chaos Swing button and the louvers will swing.
Press the button again and the louvers will stop. After 30 minutes, the
louvers return to the maximum airflow position automatically.
Horizontal Airflow Direction Control (Optional)
The left/right(Horizontal Airflow) can be adjusted by using the remote
control.
- Press the Start/Stop button to start the unit.
- Open the door on the remote control. Press the Airflow Direction Start/Stop button and the louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direction.
The up/down airflow (Vertical airflow) can be adjusted by using the remote controller.
- Press the START/STOP BUTTON to start the unit.
- Press CHAOS SWING BUTTON.
- The louvers will swing up & down automatically.
- To stop the louver at a desired angle, press again
The left/right(Horizontal airflow) can be adjusted by using the remote control.
- Press the START/STOP BUTTON to start the unit.
- Press the HORIZONTAL AIRFLOW DIRECTION BUTTON.
- The louvers will swing left & right automatically.
- To stop the louvers at a desired angle, press again.
Air Circulation Mode
Circulates the room air without cooling or heating.
- Press the Start/Stop button. the unit will respond with a beep.
- Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again.
NOTICE
❏ CHAOS Air economizes power consumption and prevents overcooling. The fan
speed is automatically changed from high to low or vice versa, depending on
the ambient temperature.
Forced Operation
The operation will be started operation if the power button is pressed without
remote controller.
If you want to stop operation, re-press the button.
| Cooling Model| Heat pump Model
---|---|---
Room Temp. 24°C(76 `f)| 21 t(70T) Room Temp. < 24(76T)| Room Temp. < 21 °C(70
°F)
Operating mode| Cooling| Cooling| Healthy Dehumidification| Heating
Indoor FAN Speed| High| High| High| High
Setting Temperature| 22 °C(72 °F)| 22 °C(72°F)| 23 °C(74°F)| 24 °C(76 T)
Auto restart
In case the power comes on again after a power failure, the unit operates
automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts
about 3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting
mode.
** In case of absence for a long time while power failure, turn off main
power to avoid undersired Auto restart.
NOTICE
** This feature is enabled by factory default setting, but you can disable it
by pressing the ON/OFF button for 6 seconds. The unit will beep twice and the
indicator lamp(2) will blink 4 times.
To enable it, press the button again for 6 seconds. The unit will beep twice
and the indicator lamp(1) will blink 4 times.
Helpful information
Fan speed and cooling capacity.
The cooling/heating capacity indicated in the specification is the value when
the fan speed is set to high, and the capacity will be lower at low or medium
fan speed.
High fan speed is recommended when you wish to cool/heat the room quickly.
Maintenance and Service
CAUTION: Before performing any maintenance, turn off the main power to
the system.
Standard Type Indoor Unit
Grille, Case, and Remote Control
❏ Turn the system off before cleaning.
To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
NOTICE
Supply power must be disconnected before cleaning the indoor unit.
AIR FILTERS
The air filters behind the front grille should be checked and cleaned once
in every 2 weeks or more often if neccessary.
NEO PLASMA FILTER, TRIPLE
DEODORIZING FILTER(OPTIONAL)
The NEO PLASMA filter behind the air filters should be checked and cleaned
once in every 3 months or more often if necessary.
**** Don’t touch this PLASMA Filter within 10 seconds after opening the inlet grille, it may cause an electric shock.
❏ Never use any of the followings:
- Water hotter than 40°C(104°F) Could cause deformation and/or discoloration.
- Volatile substances Could damage the surfaces of the air conditioner.
-
Lift the front access panel and pull the filter tab slightly forward to remove the filter.
-
Clean the filter with a vacuum cleaner or warm, soapy water.
• If dirt is conspicuous, wash with a solution of detergent in lukewarm water.
• If hot water (40°C (104°F)or more) is used, it may be deformed. -
After washing with water, dry well in the shade.
-
Re-install the air filter.
-
After removing the air filters, pull slightly forward to remove the NEO PLASMA filter.
-
Remove dust with vacuum cleaner or air. (You should not try to wash with water).
-
Note the cuts of electric discharge lines.
-
Re-install the NEO PLASMA filter to the original position.
-
After removing the air filters, pull slightly forward to remove the TRIPLE DEODORIZING filter.
-
Dry in the sunlight for two hours.
-
Re-install the TRIPLE DEODORIZING filter to the original position.
Replacement of purifying filter (Optional)
Recommended use period : About 2 years
Open the front panel as shown.
Then pull the filter tab slightly forward to remove the air filter.
After removing the air filter remove the plasma and deodorizer filter by
slightly pulling forward.
Artcool Type Indoor Unit
Grille, Case, and Remote Control
❏ Turn the system off before cleaning. To clean, wipe with a soft, dry cloth.
Do not use bleach or abrasives.
NOTICE
Supply power must be disconnected before cleaning the indoor unit.
AIR FILTER
The air filters behind the front grill should be checked and cleaned once
every 2 weeks or more often if neccessary.
❏ Never use any of the followings:
- Water hotter than 40°C(104°F). Could cause deformation and/or discoloration.
- Volatile substances Could damage the surfaces of the air conditioner.
-
Pull down the grille bottom, After lifting up the filter tab a bit and take the filter out slowly (Notice : Clean the filter after being stopped the product)
-
Clean the filter with a vacuum or warm, soapy water.
• If dirt is conspicuous, wash with a solution of detergent in lukewarm water.
• If hot water (40°C(104°F) or more) is used, it may be deformed. -
After washing with water, dry well in the shade.
-
Re-install the air filter.
Cleaning of Purifying Filter
• Recommended use period : About 3 months
- Lift the front panel, hold it up and pull the Air filter.
- Remove the Plasma Filter.
- Put in Plasma Filters in the neutral detergent for 1~2 hours and then raise them.
- Insert the Plasma Filter after perfectly drying in shade.
Now insert Air Filter and close the Front panel Completely by matching the hook.
When the air conditioner is not going to be used for a long time.
When air conditioner is not going to be used for a long time.
-
Operate the air conditioner on Air circulation mode (Refer to page 21) for 2 to 3 hours.
• This will dry out the internal mechanisms. -
Turn off the circuit breaker, and disconnect the power cable.
CAUTION: Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. -
Remove the batteries from the Remote Controller.
When the air conditioner is to be used again.
- Clean the air filter and install it in the indoor unit. (Refer to page 23~25for cleaning filters.)
- Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Operation Tips
Do not overcool the room.| Keep blinds or curtains closed.| Blockages in the
air filter reduce the airflow and lower cooling and dehumidifying effects.
Clean at least once every two weeks.
---|---|---
This is not good for the health and wastes electricity.| Keep blinds or
curtains closed.| Blockages in the air filter reduce the airflow and lower
cooling and dehumidifying effects.
Clean at least once every two weeks.
This is not good for the health and wastes electricity.| Keep blinds or
curtains closed.| Ventilate the room occasionally.
Avoid opening doors and windows if possible to keep the cool air in the room.|
Blockages in the air filter reduce the airflow and lower cooling and
dehumidifying effects. Clean at least once every two weeks.| Since windows are
kept closed, it is a good idea to open them and ventilate the room now and
then.
Troubleshooting
Check the following points before requesting repairs or service…. If the fault persists, please contact your dealer or service center.
Case | Explanation | See page |
---|---|---|
The air conditioner does not operate. | · Check room temperature setting? |
11-12, 15
· Check if circuit breaker is on?|
The room has a peculiar odor.| · Check that this is not a damp smell exuded
by the walls, carpet, furniture, or cloth items in the room.|
It seems that condensation is leaking from the air conditioner.| · Check the
drain hose is connected tight or if indoor unit is installed even.|
Air conditioner does not operate for about 3 minutes after turning on.| ·
This is the protector of the mechanism.
· Wait about 3 minutes and operation will begin.
· About 3 minutes delay is applied to protect compressor from frequenty
on/off.|
Does not cool or heat effectively.| · Is the air filter dirty? See air filter
cleaning instructions.| 23-25
· Has the temperature been set correctly?| 12, 15
· Are the indoor unit’s air inlet or outlet vents obstructed?|
The air conditioner operation is noisy.| · For a noise that sounds like water
flowing. -This is the sound of refrigerant flowing inside the air conditioner
unit.
· For a noise that sounds like the compressed air releasing into atmosphere.
-This is the sound of the dehumidifying water being processed inside the air conditioning unit.|
Remote Controller display is faint, or no display at all.| · Are the
batteries depleted?
· Are the batteries inserted in the opposite (+) and (-) directions?| 9
Crack sound is heard.| · This sound is generated by the
expansion/constriction of the front panel, etc. due to changes of
temperature.| _
P/No.: 3828A22236A Printed in Korea
After reading this manual, keep it in a place easily accessible to the user
for future reference.
Documents / Resources
| LG
LMU180CE Multi Type Air
Conditioner
[pdf] Owner's Manual
LMU180CE, LMU180CE Multi Type Air Conditioner, Multi Type Air Conditioner, Air
Conditioner, Conditioner
---|---
References
- below.Be
- realtime.at - Domain catched
- Under Construction
- Accueil
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Lg Air Conditioner Parts - Select From 2329 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>