LG LWN2123BHG Room Air Conditioner Instruction Manual

July 29, 2024
LG

LG LWN2123BHG Room Air Conditioner

Product Information

Specifications

  • Model: LG LWM1860BCP
  • Type: Room Air Conditioner
  • Models: LWM1860BCG/BCL/QCG/QCL/QAG/BAG, LWN1860BCG/BCL/QCG/QCL, LWN2260BCG/BCL/QCG/QCL, and more (refer to manual for full list)

Product Usage Instructions

  • Safety Precautions
    Before using the air conditioner, make sure to read and bunderstand all safety precautions mentioned in the manual.

  • Control Locations
    The air conditioner has different control locations based on the model type – Cooling Only Model, Heat Pump Model, and Cooling Only Model with Remote Control and Touch Type. Refer to the manual for specific control locations

Disassembly Instructions

Mechanical Parts

  • Front Grille
  • Cabinet
  • Control Box

Air Handling Parts

  • Cover (At the Top)
  • Blower
  • Fan
  • Shroud

Electrical Parts

  • Motor
  • Compressor
  • Capacitor
  • Power Cord
  • Thermostat
  • Rotary Switch
  • Synchronous Motor

Troubleshooting Guide
If you encounter any issues with the air conditioner, refer to the troubleshooting guide provided in the manual for assistance.

FAQ (Frequently Asked Questions)

  • Q: Where can I find genuine replacement parts for LG LWM1860BCP?
    A: You can shop for genuine replacement parts for LG LWM1860BCP on Appliance Factory Parts.

  • Q: What models are compatible with the LG LWM1860BCP air conditioner?
    A: The LG LWM1860BCP is compatible with models such as LWM1860BCG/BCL/QCG/QCL/QAG/BAG, LWN1860BCG/BCL/QCG/QCL, LWN2260BCG/BCL/QCG/QCL, and more. Refer to the manual for a full list of compatible models.

This Owner’s Manual is provided and hosted by Appliance Factory Parts.
LG LWM1860BCP Owner’s Manual
Shop genuine replacement parts for LG LWM1860BCP
Find Your LG Air Conditioner Parts – Select From 2328 Models

Room Air Conditioner
SERVICE MANUAL
MODELS:

  • LWM1860BCG/BCL/QCG/QCL/QAG/BAG
  • LWN1860BCG/BCL/QCG/QCL
  • LWN2260BCG/BCL/QCG/QCL
  • LWM1820BCG/BCL/QCG/QCL
  • LWM1821BCG/BCL/QCG/QCL
  • LWN2120BCG/BCL/QCG/QCL
  • LWN2123BCG
  • LWM1830BCG/BCL/QCG/QCL
  • LWN2130BCG/BCL/QCG/QCL,BXN LWN2131BAG
  • LWM2130AAG/BAG LWM1860BCP
  • LWN2120BHG/BHP/QHG LWN2123BHG

CAUTION

  • BEFORE SERVICING THE UNIT, READ THE “SAFETY PRECAUTIONS” IN THIS MANUAL.
  •  ONLY FOR AUTHORIZED SERVICE.

 PREFACE

This SERVICE MANUAL provides various service information, including the mechanical and electrical parts etc. This room air conditioner was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

  1. SAFETY PRECAUTIONS

  2.  When servicing the unit, set the ROTARY SWITCH or POWER SWITCH to OFF and unplug the power cord.

  3.  Observe the original lead dress.
    If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.

  4. After servicing the unit, make an insulation resistance test to protect the customer from being exposed to shock hazards.

  5. INSULATION RESISTANCE TEST

  6. Unplug the power cord and connect a jumper between 2 pins (black and white).

  7.  The grounding conductor (green or green & yellow) is to be open.

  8. Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part on the equipment at all the positions (except OFF or O) of the ROTARY SWITCH.

  9. The value should be over 1MΩ.

 SPECIFICATIONS

FOR LWM1860BCG(BCL)/LWN1860BCG(BCL)/LWN2260BCG(BCL)/LWM1820BCG(BCL)LWM1821BCG(BCL) LWN2120BCG(BCL)/LWM1830BCG(BCL)/LWN2130BCG(BCL)/LWN2123BCG/BAG / LWM2130AAG/BAG

MODELS

ITEMS

| LWM1860 BCG(BCL) BAG/BCP| LWN1860 BCG (BCL)| LWN2260 BCG (BCL)| LWN1820/1 BCG (BCL)| LWN2120 BCG (BCL)| LWN2123 BCG| LWM2130 AAG/ BAG| LWN1830 BCG (BCL)| LWN2130 BCG(BCL) LWN2131BAG| ****

REMARK

---|---|---|---|---|---|---|---|---|---|---
POWER SUPPLY| 1Ø, 220-240V, 50Hz| 1Ø, 220V, 60Hz| 1Ø, 208-230V, 60Hz|
COOLING CAPACITY| 17,500/18,000| 21,500/22,000| 18,000| 21,000| 24,000| 22,000| 18,000| 21,000|
INPUT                        (W)| 2,035/2,100| 2,190/2250| 2,810/2,890| 2,090/2,000| 2,440| 2,470| 2,000| 2,470|
RUNNING CURRENT      (A)| 9.3/8.6| 10.6/10.1| 13.5/12.8| 9.8/9.0| 11.5| 10.8| 9.0| 12|
REFRIGERANT (R-22) CHARGE(g)| 690| 610| 600| 630| 700| 710| 740| 1,090|
OPERATING TEMPERATURE| INDOOR (°C)| 27(DB), 19(WB)| 26.55(DB), 19.35(WB)|
OUTDOOR (°C)| 35(DB), 24(WB)| 34.85(DB), 23.75(WB)|
EVAPORATOR| 2 ROW 15 STACKS| 3 ROW 15 STACKS|
CONDENSER| 2 ROW 19 STACKS, L-BENDED TYPE| 2 ROW 16 STACKS L-BENDING TYPE
FAN, INDOOR| BLOWER|
FAN, OUTDOOR| PROPELLER TYPE FAN WITH SLINGER-RING|
FAN SPEEDS, FAN/COOLING| 2/3|
FAN MOTOR| 6 POLES|
OPERATION CONTROL| ROTARY SWITCH|
ROOM TEMP. CONTROL| THERMOSTAT|
AIR DIRECTION CONTROL| VERTICAL LOUVER(RIGHT & LEFT)|
HORIZONTAL LOUVER(UP & DOWN)|
CONSTRUCTION| SLIDE IN-OUT CHASSIS|
PROTECTOR| COMPRESSOR| INTERNAL OVERLOAD PROTECTOR|
FAN MOTOR| INTERNAL THERMAL PROTECTOR|
POWER CORD| 1.6m (3 WIRE WITH GROUNDING)|
CORD-CONNECTED TYPE (ATTACHMENT PLUG: OPTION)|
DRAIN SYSTEM| DRAIN PIPE OR SPLASHED BY FAN SLINGER|
NET WEIGHT          (lbs/kg)| 132/60| 143/65| 148/67| 121/55| 148/67| 121/55| 143/65|
OUTSIDE DIMENSION (W x H x D)| (inch)| 26 x 1627/32 x 269/16| 26 x 1627/32 x 305/16| 26 x 1627/32 x 269/16| 26 x 1627/32 x 305/16| 26 x 1627/32 x 269/16| 26 x 1627/32 x 305/16|
(mm)| 660 x 428 x 675| 660 x 428 x 770| 660 x 428 x 675| 660 x 428 x 770| 660 x 428 x 675| 660 x 428 x 770|

FOR LWM1860QCG(QCL, QAG)/LWN1860QCG(QCL)/LWN2260QCG(QCL)/LWM1820QCG(QCL) LWM1821QCG(QCL)/LWN2120QCG(QCL)/LWM1830QCG(QCL)/LWN2130QCG(QCL)

MODELS ITEMS| LWM1860 QCG (QCL, QAG)| LWN1860 QCG(QCL)| LWN2260 QCG(QCL)| LWM1820/1 QCG(QCL)| LWN2120 QCG(QCL)| LWM1830 QCG(QCL)| LWN2130 QCG(QCL)| REMARK
---|---|---|---|---|---|---|---|---
POWER SUPPLY| | 1Ø, 220-240V, 50Hz| | 1Ø, 220V, 60Hz| |
COOLING CAPACITY| 17,500/18,000| 21,500/22,000| 18,000| 21,000| 18,000| 21,000|
INPUT                              (W)| 2,035/2,100| 2,190/2,250| 2,810/2,890| 2,090/2,000| 2,440| 2,000| 2,470|
RUNNING CURRENT         (A)| 9.3/8.6| 10.6/10.1| 13.5/12.8| 9.8/9.0| 11.5| 9.0| 12|
REFRIGERANT (R-22) CHARGE(g)| 690| 610| 600| 630| 700| 740| 1,090|
OPERATING TEMPERATURE| INDOOR (°C)| 27(DB), 19(WB)| 26.55(DB), 19.35(WB)|
OUTDOOR (°C)| 35(DB), 24(WB)| 34.85(DB), 23.75(WB)|
EVAPORATOR| 2 ROW 15 STACKS| 3 ROW 15 STACKS|
CONDENSER| 2 ROW 19 STACKS, L-BENDED TYPE| 2 ROW 16 STACKS, L-BENDING TYPE
FAN, INDOOR| BLOWER|
FAN, OUTDOOR| PROPELLER TYPE FAN WITH SLINGER-RING|
FAN SPEEDS, FAN/COOLING| 2/2|
FAN MOTOR| 6 POLES|
OPERATION CONTROL| WIRELESS REMOCON|
ROOM TEMP. CONTROL| THERMISTOR|


AIR DIRECTION CONTROL

| VERTICAL LOUVER(RIGHT & LEFT)|
HORIZONTAL LOUVER(UP & DOWN)|
CONSTRUCTION| SLIDE IN-OUT CHASSIS|


PROTECTOR

| COMPRESSOR| INTERNAL OVERLOAD PROTECTOR|
FAN MOTOR| INTERNAL THERMAL PROTECTOR|
POWER CORD| 1.6m (3 WIRE WITH GROUNDING)|
CORD-CONNECTED TYPE (ATTACHMENT PLUG: OPTION)|
DRAIN SYSTEM| DRAIN PIPE OR SPLASHED BY FAN SLINGER|
NET WEIGHT              (lbs/kg)| 132/60| 143/65| 148/67| 121/55| 148/67| 121/55| 143/65|
OUTSIDE DIMENSION

(W x H x D)

| (inch)| 26 x 1627/32 x 269/16| 26 x 1627/32 x 305/16| 26 x 1627/32 x 269/16| 26 x 1627/32 x 305/16| 26 x 1627/32 x 269/16| 26 x 1627/32 x 305/16|
(mm)| 660 x 428 x 675| 660 x 428 x 770| 660 x 428 x 675| 660 x 428 x 770| 660 x 428 x 675| 660 x 428 x 770|

FOR LWN2120BHG/BHP/QHG, LWN2123BHG

MODELS ITEMS| **LWN2120BHG/BHP| ****LWN2120QHG| ****LWN2123BHG**
---|---|---|---
POWER SUPPLY| 1ø, 220V, 60Hz



COOLING

| CAPACITY          (BTU/H)| 24,000
INPUT                       (W)| 2,560
RUNNING CURRENT (A)| 12.3
E.E.R             (BTU/W.h)| –



HEATING

| CAPACITY          (BTU/h)| 24,000
INPUT                       (W)| 2,560
RUNNING CURRENT (A)| 12.3
E.E.R             (BTU/W.h)| 9.4


OPERATING TEMPERA- TURE

| COOLING| INDOOR     (°C)| 27 (DB)* 19 (WB)**
OUTDOOR (°C)| | 35 (DB)| 24 (WB)|
HEATING| INDOOR     (°C)| | 20 (DB)| 15 (WB)|
OUTDOOR (°C)| | 7 (DB)| 6 (WB)|
REFRIGERANT (R-22) CHARGE| 1200g (42.3 Oz)
EVAPORATOR| 3ROW 15STACKS, LOUVERED-FIN TYPE
CONDENSER| 2ROW 16STACKS, LOUVERED-FIN TYPE
FAN, INDOOR| TURBO FAN
FAN, OUTDOOR| PROPELLER TYPE FAN WITH SLINGER-RING
FAN SPEEDS, FAN/COOLING/HEATING| 1/2/2| 2/2/2| 1/2/2
FAN MOTOR| 6 POLES
OPERATION CONTROL| ROTARY SWITCH| WIRELESS REMOCON| ROTARY SWITCH
ROOM TEMP. CONTROL| THERMOSTAT| THERMISTOR| THERMOSTAT
AIR DIRECTION CONTROL| VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
CONSTRUCTION| SLIDE IN-OUT CHASSIS
PROTECTOR| COMPRESSOR| OVERLOAD PROTECTOR
FAN MOTOR| INTERNAL THERMAL PROTECTOR
POWER CORD| 1.8m (7″) (3 WIRE WITH GROUDING)
| ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN SYSTEM| DRAIN PAN OR SPLASHED BY FAN SLINGER
NET WEIGHT                           (lbs/kg)| 147.7(67)
OUTSIDE DIMENSION (W X H X D)| (inch)| 23 x 1627/32 x 305/16
(mm)| 660 x 428 x 770

    • DB : dry bulb
  • ** WB : wet bulb

FEATURES

  • Designed for cooling only.
  • Powerful and quiet cooling.
  • Slide-in and slide-out chassis for the simple installation and service.
  • Reversible inlet grille.

CONTROL LOCATIONS

COOLING ONLY MODEL

  • VENTILATION
    The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When a fresh air is necessary in the room, set the ventilation lever to the OPEN position.
    The damper is opened and room air is exhausted.

  • NOTE: Before using the ventilation feature, make the lever, as shown. First, pull down part a  to horizontal line with part  b.

THERMOSTAT

  • Thermostat will automatically control the temperature of the room. Select the higher number for the lower temperature of the room. The temperature is selected by positioning the knob to the desired position.
  • The 5 or 6 position is a normal setting for average conditions.

OPERATIONLG-LWN2123BHG-Room-Air-Conditioner- \(2\)

AUTO SWING

LG-LWN2123BHG-Room-Air-Conditioner- \(3\)LG-
LWN2123BHG-Room-Air-Conditioner- \(4\) LG-
LWN2123BHG-Room-Air-Conditioner- \(5\)

HEAT PUMP MODEL

  • CAUTION
    When the air conditioner has been performing its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again.LG-LWN2123BHG-Room-Air-Conditioner-
\(6\)

THERMOSTAT

  • Turn the thermostat control to the desired setting. The control position is a normal setting for average conditions. You can change this setting, if necessary, in accordance with your temperature preference.
  • The thermostat automatically controls cooling or heating, but the fan runs continuously whenever the air conditioner is in operation. If the room is too warm, turn the thermostat control clockwise. If the room is too cool, turn the thermostat control counterclockwise.

HEATER LAMP

  • When the unit sets heating operation condition, the green lamp is lighted.
  • When the frost settles on the heat exchanger of the outside, defrosting is made automatically and the green lamp is turned off. The unit may give a hiss and the fan motor stops for 1 to 10 minutes.
  • This should not be regarded as a problem.
  • After defrosting, the heating operation begins again.

OPERATION LG-LWN2123BHG-Room-Air-Conditioner-
\(7\)

AUTO SWING

LG-LWN2123BHG-Room-Air-Conditioner- \(8\)

COOLING ONLY MODEL WITH REMOTE CONTROL AND TOUCH TYPE

LG-LWN2123BHG-Room-Air-Conditioner- \(9\)

Precaution : The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Control unit and the air conditioner.

  1. POWER BUTTON
    Operation starts, when this button is pressed and stops when you press the button again.

  2. OPERATION MODE SELECTION BUTTON
    Select Cooling, or Fan or Dehumid mode with button. (Dehumid mode is not to all models.)

  3. ON/OFF TIMER BUTTON
    Set the time of starting and stopping operation. The timer is set by 1 hour.

  4. FAN SPEED SELECTOR
    Everytime you push this button it is set as follows. [High(F3) → Low(F1) → Med(F2) → High(F3)…].

  5. ROOM TEMPERATURE SETTING BUTTON
    Control the room temperature within a range of 16°C to 30°C.

  6. AUTO RESTART SWITCH (NOT TO ALL MODELS)
    In failure of electric power, if the switch is set to “ON”, the unit runs as previous setting operation when power returns.

  7. AUTO SWING BUTTON
    Control the horizontal air direcion by air swing system.

  8. SIGNAL RECEIVER

LG-LWN2123BHG-Room-Air-Conditioner- \(10\)

Precaution: The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or it there are obstacles between the Remote Control unit and the air conditioner.

  1. POWER BUTTON
    Operation starts, when this button is pressed and stops when you press the button again.

  2. OPERATION MODE SELECTION BUTTON
    Select Cooling, Heating, Fan or Dehumidification(Dry) mode with this button.

  3. ON/OFF TIMER BUTTON
    Set the time of starting and stopping operation.
    The timer is set by 1 hour.

  4. FAN SPEED SELECTOR

    • Select the fan speed
    • Cooling Model: High[F3] ➔ Low[F1] ➔ Med[F2] ➔ High[F3] ….
    • Heating Model: High[F2] ➔ Low[F1] ➔ High[F2] ….
  5. ROOM TEMPERATURE SETTING BUTTON
    Control the room temperature within a range of 16°C to 30°C.
    The unit takes an average of 30 minutes to adjust the room temperature by 1°C (1.8°F).
    Temperature increases only by 2°C and no longer increase thereafter.

  6. AUTO SWING
    The vertical louver swings horizontally by the automatic system and stops when you press the button again.

  7. SIGNAL RECEIVER

DISASSEMBLY INSTRUCTIONS

Before the following disassembly, POWER SWITCH is set to OFF and disconnected the power cord.

MECHANICAL PARTS

FRONT GRILLE

  1. Open the inlet grille upward or downward.
  2. Remove the screw which fastens the front grille.
  3. Pull the front grille from the right side.
  4.  Remove the front grille. (See Fig. 1)
  5.  Re-install the component by referring to the removal procedure.
    NOTE: Mark “Δ “of inlet grille means opening direction.

CABINET

  1. After disassembling the FRONT GRILLE, remove the screws which fasten the cabinet at both sides.
  2. Remove the two screws which fasten the cabinet at back. (See Fig. 2)
  3.  Pull the base pan forward.

CONTROL BOX

  1. Remove the front grille. (Refer to section 2.1.1)
  2. Pull the base pan forward so that you can remove the 2 screws which fasten the cover control at the right side. (See Fig. 3)
  3. Remove the 3 screws which fasten the control box. (See Fig. 3)
  4. Discharge the capacitor by placing a 20,000 ohm resistor across the capacitor terminals.
  5. Disconnect two wire housings in the control box.
  6. Pull the control box forward completely.
  7. Re-install the components by referring to the removal procedure. (See Fig. 3)
    (Refer to the circuit diagram found on page 19 in this manual and on the control box.)

AIR HANDLING PARTS

COVER (AT THE TOP)

  1. Remove the front grille. (Refer to section 2.1.1)
  2. Remove the cabinet. (Refer to section 2.1.2)
  3. Remove 11 screws which fasten the brace and covers.
  4. Remove the covers and the brace. (See Fig. 4)
  5. Re-install the components by referring to the removal procedure, above.

BLOWER

  1. Remove the cover. (Refer to section 2.2.1)
  2. Remove the 3 screws which fasten the evaporator at the left side and the top side.
  3. Move the evaporator sideward carefully.
  4. Remove the orifice from the air guide carefully.
  5. Remove the clamp which secures the blower with plier. (See Fig. 5)
  6. Remove the blower with plier or your hand without touching blades. (See Fig. 6)
  7. Re-install the components by referring to the removal procedure, above.LG-LWN2123BHG-Room-Air-Conditioner- \(15\)

FAN

  1. Remove the cabinet. (Refer to section 2.1.2)
  2. Remove the brace and shroud cover. (Refer to section 2.2.1)
  3. Remove the 5 screws which fasten the condenser.
  4. Move the condenser sideways carefully.
  5. Remove the clamp which secures the fan.
  6. Remove the fan. (See Fig. 7)
  7. Re-install the components by referring to the removal procedure, above.

SHROUD

  1. Remove the fan. (Refer to section 2.2.3)
  2. Remove the 2 screws which fasten the shroud.
  3. Remove the shroud. (See Fig. 8)
  4. Re-install the component by referring to the removal procedure, above.

ELECTRICAL PARTS
MOTOR

  1. Remove the cabinet. (Refer to section 2.1.2)
  2. Remove the cover control and disconnect a wire housing in control box. (Refer to section 2.1.3)
  3. Remove the blower. (Refer to section 2.2.2)
  4. Remove the fan. (Refer to section 2.2.3)
  5. Remove the 4 screws which fasten the motor.(See Fig. 9)
  6. Remove the motor.
  7. Re-install the components by referring to the removal procedure, above.

COMPRESSOR

  1. Remove the cabinet. (Refer to section 2.1.2)

  2. Discharge the refrigerant system using FreonTM Recovery System.
    If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM . Leave the valve in place after servicing the system.

  3. Disconnect the 3 leads from the compressor.

  4. After purging the unit completely, unbrace the suction and discharge tubes at the compressor connections.

  5. Remove the 3 nuts and the 3 washers which fasten the compressor.

  6. Remove the compressor. (See Fig. 10)

  7. Re-instill the components by referring to the removal procedure, above.

CAPACITOR

  1. Remove the control box. (Refer to section 2.1.3)
  2. Remove the screw and knobs which fasten the display panel.
  3. Disconnect the 2 leads from the rocker switch and remove the panel.
  4. Remove a screw and unfold the control box. (See Fig. 11)
  5. Remove the screw and the clamp which fastens the capacitor. (See Fig. 11)
  6. Disconnect all the leads of capacitor terminals.
  7. Re-install the components by referring to the removal procedure, above.

POWER CORD

  1. Remove the control box. (Refer to section 2.1.3)
  2. Unfold the control box. (Refer to section 2.3.3)
  3. Disconnect the grounding screw from the control box.
  4. Disconnect 2 receptacles.
  5. Remove a screw which fastens the clip cord.
  6. Pull the power cord. (See Fig. 12)
  7. Re-install the component by referring to the removal procedure, above.
    (Use only one ground-marked hole   for ground connection.)

THERMOSTAT

  1. Remove the control box. (Refer to section 2.1.3)
  2. Unfold the control box. (Refer to section 2.3.3)
  3. Remove the 2 screws which fasten the thermostat.
  4. Disconnect all the leads of thermostat terminals.
  5. Remove the thermostat. (See Fig. 13)
  6. Re-install the components by referring to the removal procedure, above.

ROTARY SWITCH

  1.  Remove the control box. (Refer to section 2.1.3)
  2. Unfold the control box. (Refer to section 2.3.3)
  3. Remove 2 screws which fasten the rotary switch.
  4. Disconnect all the leads of the rotary switch terminals.
  5. Remove the rotary switch. (See Fig. 14)
  6. Re-install the components by referring to the above removal procedure, above.

SYNCHRONOUS MOTOR

  1. Remove the control box. (Refer to section 2.1.3)
  2. Unfold the control box. (Refer to section 2.3.3)
  3. Remove the crankshaft.
  4. Disconnect all the leads of the synchronous motor.
  5.  Remove the 2 screws which fasten the synchronous motor. (See Fig. 15)
  6. Re-install the components by referring to the removal procedure, above.

REFRIGERATION CYCLE

  1. CAUTION
    Discharge the refrigerant system using FreonTM Recovery System.
    If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

CONDENSER

  1. Remove the cabinet. (Refer to section 2.1.2)
  2. Remove the brace and the shroud cover. (Refer to section 2.2.1)
  3. Remove 6 screws which fasten the condenser.
  4. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.
  5. Remove the condenser.
  6. Re-install the components by referring to notes. (See Fig. 16)

EVAPORATOR

  1. Remove the cabinet. (Refer to section 2.1.2)
  2. Remove the top cover and the brace. (Refer to section 2.2.1)
  3. Discharge the refrigerant completely.
  4. Remove the 3 screws which fasten the evaporator at the left side and the top side.
  5. Move the evaporator sideward carefully and then unbraze the interconnecting tube at the evaporator connectors.
  6. Remove the evaporator.
  7. Re-install the components by referring to notes. (See Fig. 17)

CAPILLARY TUBE

  1. Remove the cabinet. (Refer to section 2.1.2)
  2. Remove the brace. (Refer to section 2.2.1)
  3. After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube.
  4. Remove the capillary tube.
  5. Re-install the components by referring to notes.

Replacement of the refrigeration cycle.

  1. When replacing the refrigeration cycle, be sure to discharge the refrigerant system using a FreonTM recovery System.
    If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

  2. After discharging the unit completely, remove the desired component, and unbrace the pinch-off tubes.

  3. Solder service valves into the pinch-off tube ports, leaving the valves open.

  4. Solder the pinch-off tubes with Service valves.

  5. Evacuate as follows.

  6. Connect the vacuum pump, as illustrated Fig. 18A.

  7. Start the vacuum pump, slowly open manifold valves A and B with two full turns counterclockwise and leave the valves closed. The vacuum pump is now pulling through valves A and B up to valve C by means of the manifold and entire system.
    CAUTION
    If high vacuum equipment is used, just crack valves A and B for a few minutes, then open slowly with the two full turns counterclockwise. This will keep oil from foaming and being drawn into the vacuum pump.

  8. Operate the vacuum pump for 20 to 30 minutes, until 600 microns of vacuum is obtained. Close valves A and B, and observe vacuum gauge for a few minutes. A rise in pressure would indicate a possible leak or moisture remaining in the system. With valves A and B closed, stop the vacuum pump.

  9. Remove the hose from the vacuum pump and place it on the charging cylinder. See Fig. 19B. Open valve C.
    Discharge the line at the manifold connection.

  10. The system is now ready for final charging.

  11. Recharge as follows :

  12. Refrigeration cycle systems are charged from the High-side. If the total charge cannot be put in the High-side, the balance will be put in the suction line through the access valve which you installed as the system was opened.

  13. Connect the charging cylinder as shown in Fig. 18B. With valve C open, discharge the hose at the manifold connection.

  14. Open valve A and allow the proper charge to enter the system. Valve B is still closed.

  15. If more charge is required, the high-side will not take it. Close valve A.

  16. With the unit running, open valve B and add the balance of the charge.
    Do not add the liquid refrigerant to the Low-side.
    Watch the Low-side gauge; allow pressure to rise to 30 lbs.
    Turn off valve B and allow pressure to drop.
    Repeat steps B and C until the balance of the charge is in the system.

  17. When satisfied the unit is operating correctly, use the pinch-off tool with the unit still running and clamp on to the pinch-off tube. Using a tube cutter, cut the pinch-off tube about 2 inches from the pinch-off tool. Use sil-fos solder and solder pinch-off tube closed. Turn off the unit, allow it to set for a while, and then test the leakage of the pinch-off connection.

Equipment needed : Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.LG-
LWN2123BHG-Room-Air-Conditioner- \(29\) LG-
LWN2123BHG-Room-Air-Conditioner- \(30\)

TROUBLESHOOTING GUIDE

OUTSIDE DIMENSIONS

LG-LWN2123BHG-Room-Air-Conditioner- \(31\)

PIPING SYSTEM

LG-LWN2123BHG-Room-Air-Conditioner- \(32\)

Following is a brief description of the important components and their functions in the refrigeration system. Refer to Fig. 19 to follow the refrigeration cycle and the flow of the refrigerant in the cooling cycle. LG-LWN2123BHG-Room-Air-Conditioner- \(33\)

TROUBLESHOOTING GUIDE
In general, possible trouble is classified in two causes.
The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
Unit runs but poor cooling LG-LWN2123BHG-Room-Air-Conditioner-
\(34\) LG-LWN2123BHG-Room-Air-Conditioner-
\(35\) LG-LWN2123BHG-Room-Air-Conditioner-
\(36\) LG-LWN2123BHG-Room-Air-Conditioner-
\(37\) LG-LWN2123BHG-Room-Air-Conditioner-
\(38\)

Possible Trouble 1 The unit does not operate.

LG-LWN2123BHG-Room-Air-Conditioner- \(39\) LG-
LWN2123BHG-Room-Air-Conditioner- \(40\)

Possible Trouble 2 The compressor does not operate.

LG-LWN2123BHG-Room-Air-Conditioner- \(41\)

Possible Trouble 3 The compressor always operate.

LG-LWN2123BHG-Room-Air-Conditioner- \(42\)

Possible Trouble 4 FAN does not operate.

LG-LWN2123BHG-Room-Air-Conditioner- \(43\)

FAN does not operate. Auto Swing does not operate.

LG-LWN2123BHG-Room-Air-Conditioner- \(44\)

Possible Trouble 6 Remote controller does not operate.

LG-LWN2123BHG-Room-Air-Conditioner- \(45\)

Possible Trouble 7 It displays abnormally on display PCB Ass’y.

LG-LWN2123BHG-Room-Air-Conditioner- \(46\)

Possible Trouble 8 The function of Auto Restart does not operate.LG-
LWN2123BHG-Room-Air-Conditioner- \(47\)

COMPLAINT CAUSE REMEDY
Fan motor will not run. No power Check voltage at outlet. Correct if none.
Power supply cord Check voltage to rotary switch. If none, check power supply

cord. Replace cord if circuit is open.
Rotary switch| Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective.
Wire disconnected or connection loose| Connect wire. Refer to wiring diagram for terminal identification. Repair or replace loose terminal.
Capacitor (Discharge capacitor before testing.)|

  • Test capacitor.
  • Replace if not within ±10% of manufacturer’s rating. Replace if shorted, open, or damaged.

Will not rotate|

  • Fan blade hitting shroud or blower wheel hitting scroll. Realign assembly.
  • Units using slinger ring condenser fans must have 1/4 to 5/16 inch clearance to the base. If it is hitting the base, shim up the bottom of the fan motor with mounting screw(s).
  • Check fan motor bearings; if motor shaft will not rotate, replace the motor.

Fan motor runs intermittently| Revolves on overload.|

  • Check voltage. See limits on this page. If not within limits, call an electrician.
  • Test capacitor.
  • Check bearings. Does the fan blade rotate freely? If not, replace fan motor.
  • Pay attention to any change from high speed to low speed. If the speed does not change, replace the motor.

Fan motor noise.| Grommets| Check grommets; if worn or missing, replace them.
Fan| If cracked, out of balance, or partially missing, replace it.
Blower| If cracked, out of balance, or partially missing, replace it.
Loose set screw| Tighten it.
Worn bearings| If knocking sounds continue when running or loose, replace the motor. If the motor hums or noise appears to be internal while running, replace motor.
COMPLAINT| CAUSE| REMEDY
---|---|---
Compressor will not run, but fan motor runs.| Voltage| Check voltage. See the limits on the preceding. page. If not within limits, call an electrician.
Wiring| Check the wire connections, if loose, repair or replace the terminal. If wires are off, refer to wiring diagram for identification, and replace. Check wire locations. If not per wiring diagram, correct.
Rotary| Check for continuity, refer to the wiring diagram for terminal identification. Replace the switch if circuit is open.
Thermostat|

  • Check the position of knob If not at the coldest setting, advance the knob to this setting and restart unit.
  • Check continuity of the thermostat. Replace thermostat if circuit is open.

Capacitor (Discharge capacitor before servicing.)|

  • Check the capacitor.
  • Replace if not within ±10% of manufacturers rating. Replace if shorted, open, or damaged.

Compressor| Check the compressor for open circuit or ground. If open or grounded, replace the compressor.
Overload| Check the compressor overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool it, and retest.)
Compressor cycles on overload.| Voltage| Check the voltage. See the limits on the preceding page. If not within limits, call an electrician.
Overload|

  • Check overload, if externally mounted.
  • Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.)

Fan motor| If not running, determine the cause. Replace if required.
Condenser air flow restriction| Remove the cabinet. inspect the interior surface of the condenser; if restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush. Clean the interior base before reassembling.
Condenser fins (damaged)| If condenser fins are closed over a large area on the coil surface, head pressures will increase, causing the compressor to cycle. Straighten the fins or replace the coil.
COMPLAINT| CAUSE| REMEDY
---|---|---
Compressor cycles on overload.| Capacitor| Test capacitor.
Wiring| Check the terminals. If loose, repair or replace.
Refrigerating system| Check the system for a restriction.
Insufficient cooling or heating| Air filter| If restricted, clean of replace.
Exhaust damper door| Close if open.
Unit undersized| Determine if the unit is properly sized for the area to be cooled.
Excessive noise.| Blower or fan| Check the set screw or clamp. If loose or missing, correct. If the blower or fan is hitting air guide, rearrange the air handling parts.
Copper tubing| Remove the cabinet and carefully rearrange tubing not to contact cabinet, compressor, shroud, and barrier.
Auto air-swing fails.| Rotary switch.| Set the knob to HIGH COOL or LOW COOL while rocker switch is ON.
Wiring| Check terminals. If loose, repair or replace.
Synchronous motor.| Check the synchronous motor for open circuit.

SCHEMATIC DIAGRAM

CIRCUIT DIAGRAM

MODEL : LWN1860BCG(BCL, BCP, BAG)/LWN2260BCG(BCL)/LWM1860BCG(BCL)/LWM1820BCG(BCL)

  • MODEL : LWN2123BCG
  • MODEL : LWN2120BHG/BHP LWN2123BHGLG-LWN2123BHG-Room-Air-Conditioner- \(49\)
  • MODEL : LWM1860QCG(QCL)/LWN1860QCG(QCL)/LWN2260QCG(QCL)/LWM1820QCG(QCL) LWM1821QCG(QCL)/LWN2120QCG(QCL)/LWM1830QCG(QCL)/LWN2130QCG(QCL)
  • MODEL : LWM1860QAG
  • MODEL : LWN2120QHG LG-LWN2123BHG-Room-Air-Conditioner- \(51\)

 ELECTROINC CONTROL DEVICE

  • MODEL: Micom ModelsLG-LWN2123BHG-Room-Air-Conditioner- \(52\) LG-LWN2123BHG-Room-Air-Conditioner- \(53\)

COMPONENTS LOCATION (OF MAIN P.C.B ASM)

  • MODEL: LWM1860QCG/QCL/QAG, LWN1860QCG/QCL, LWN2260QCG/QCL LWM1820QCG/QCL, LWM1821QCG/QCL, LWN2120QCG/QCL LWM1830QCG/QCL, LWN2130QCG/QCLLG-LWN2123BHG-Room-Air-Conditioner- \(54\)
  • MODEL: LWN2120BHG/BHP/QHG, LWN2123BHGLG-LWN2123BHG-Room-Air-Conditioner- \(55\)

COMPONENTS LOCATION (FOR DISPLAY P.C.B ASM)

  • MODEL : LWM1860QCG/QCL/QAG, LWM1860QCG/QCL, LWN2260QCG/QCL LWM1820QCG/QCL, LWM1821QCG/QCL, LWN2120QCG/QCL LWM1830QCG/QCL, LWN2130QCG/QCLLG-LWN2123BHG-Room-Air-Conditioner- \(56\)
  • MODEL: LWN2120BHG/BHP/QHG, LWN2123BHG LG-LWN2123BHG-Room-Air-Conditioner- \(57\)

EXPLODED VIEW

  • COOLING MODELLG-LWN2123BHG-Room-Air-Conditioner- \(58\) LG-LWN2123BHG-Room-Air-Conditioner- \(59\) LG-LWN2123BHG-Room-Air-Conditioner- \(60\)
  • HEATING MODEL LG-LWN2123BHG-Room-Air-Conditioner- \(61\) LG-LWN2123BHG-Room-Air-Conditioner- \(62\) LG-LWN2123BHG-Room-Air-Conditioner- \(63\)

REPLACEMENT PARTS LIST

LOCATION NO .| ****

DESCRIPTION

| PART NO.| ****

REMARK

---|---|---|---
LWN1860 BCG(BCL)| LWM1860 BCG(BCL)| LWM1860 BCP| LWM1830 BCG(BCL)| LWM1860 BAG| LWN2123 BCG
130410| BASE ASSEMBLY, SINGLE| 3041A30001B| 3041A30002F| 3041A30002F| 3041A30002B| 3041A30002F| 3041A30001K| R
130910| CABINET ASSEMBLY| 3061AR6056B| 3091AR6057B| 3091AR6057B| 3091AR6057B| 3091AR6057B| 3091AR6056B| R
135303| GRILLE, INLET| 3530AR1604A(5236AR1329A)| 3530AR1604A(5236AR1329A)| –| 3530AR1604A(5236AR1329A)| 3530AR1604A| 3530AR1604D| R
135312| GRILLE ASSEMBLY, FRONT(SINGLE)| 3531A20005A(3531AR2632D)| 3531A20005A(3531AR2632D)| 3531A20005K| 3531A20005A(3531AR2632D)| 3531A20005L| 3531A20005V| R
135313| GRILLE INLET| –| –| 3531A20005A| –| –| –|
135500| COVER, CONTROL BOX| 3550AR7245A| 3550AR7245A| –| 3550AR7245A| –| –| R
135510| COVER ASSEMBLY, CONTROL| –| –| 3551A30015A| –| –| 3551A30015A| R
137215| PANEL ASSEMBLY, CONTROL| 3721A20002A| 3721A20002A| 3721A20002A| 3721A20002B| 3721A20002A| 3721A20035G| R
146812| MOTOR ASSEMBLY, SYNC| 2H01102A| 2H01102A| 2H01102A| 2H01102A| 2H01102A| 2H01102A| R
147581-1| LOUVER, HORIZONTAL| 4758A7264A(-)| 4758A7264A(-)| 4758A7264A| 4758A7264A(-)| 4758A7264A(-)| 4758AR7264F| R
147581-2| LOUVER, HORIZONTAL| 4758AR7278A(-)| 4758AR7278A(-)| 4758AR7278A| 4758AR7278A(-)| 4758AR7278A(-)| 4758AR7278F| R
147582| LOUVER, VERTICAL| 4758AR6157A| 4758AR6157A| 4758AR6157A| 4758AR6157A| 4758AR6157A| 4758AR6157A| R
148000| BRACE| 4800AR7271A| 4800AR7272A| 4800AR7272A| 4800AR7271A| 4800AR7272A| 4800AR7271A| R
149410| KNOB ASSEMBLY| 4941A30001A (4941A30001B)| –| 4941A30001A| 4941A30001A (4941A30001B)| 4941A30001A| 4941A30001K| R
149980| SHROUD| 4998AR1597A| 4998AR1597A| 4998AR1597A| 4998AR1597A| 4998AR1597A| 4998AR1597A| R
152302| FILTER ASSEMBLY, A/C| 5231AR6159A(5230AR1327A)| 5231AR6159A(5230AR1327A)| 5231AR6159A| 5231AR6159A(5230AR1327A)| 5231AR6159A(5230AR1327A)| 5231AR6159D| R
249950| CONTROL BOX ASSEMBLY, SINGLE| 4995A20005D| 4995A20005V/Y| 4995A20057Q| 4995A20005P| 4995A20057Q| 4995A20088G| R
264110| POWER CORD ASSEMBLY| 3H01307C| 3H03555B| 3H01307D| 2H00677Q| 3H01307D| 3H01307C| R
266002| SWITCH, ROCKER| 2H01316C| 2H01316C| 2H01316C| 2H01316C| 2H01316C| –| R
266003| SWITCH, ROTARY| 2H00598E| 2H00598E| 2H00598E| 2H00598E| 2H00598E| 2H00598E| R
269310| THERMOSTAT ASSEMBLY| 2H01109L| 2H01109M| 2H01109M| 2H01109L| 2H01109M| 2H01109M| R
346811| MOTOR ASSEMBLY, SINGLE| 4681AR6033A| 4681AR6033H| 4681AR6033H| 4681AR6033B| 4681AR6033H| 4681AR6033F| R
349001| DAMPER, VENTILATION| 4900AR7256A| 4900AR7256A| 4900AR7256A| 4900AR7256A| 4900AR7256A| 4900AR7265A| R
349480| ORIFICE| 4948AR7241A| 4948AR7241A| 4948AR7241A| 4948AR7241A| 4948AR7241A| 4948AR7241A| R
349600| MOTOR MOUNT| 4960AR1596A| 4960AR1596A| 4960AR1596A| 4960AR1596A| 4960AR1596A| 4960AR1596A| R
352111| TUBE ASSEMBLY, CONNECTION| 5211AR7059C| 5211AR7059A| 5211AR7059W| 5211AR7059E| 5211AR7059A| 5211AR7059C| R
352113| TUBE ASSEMBLY, DISCHARGE| 5211A30003A| 5211A30066B| 5211A30066B| 5211A30066A| 5211A30066B| 5211A30131A| R
35211A| TUBE ASSEMBLY, SUCTION| 5211A30002A| 5211A30154A| 5211A30154A| 5211A30065A| 5211A30154A| 5211A30130A| R
352390| AIR GUIDE ASSEMBLY| 5239A20001A| 5239A20001A| 5239A20001A| 5239A20001D| 5239A20001A| 5239A20001A| R
354210| EVAPORATOR ASSEMBLY| 5421A20009A| 5421A20009A| 5421A20009A| 5421A20017B| 5421A20009A| 5421A20017A| R
359012| FAN ASSEMBLY, BLOWER| 5834AR1599A| 5834AR1599A| 5834AR1599A| 5834AR1599A| 5834AR1599A| 5834AR1599B| R
550140| ISOLATOR, COMP| –| –| 4022U-L005A| –| 4022U-L005A| 4H01765A| R
552101| TUBE CAPILLARY| 5425AR3147A| 3H03750L| –| 3H03750S| –| 5425AR3147X| R
552102| TUBE, CAPILLARY BEND| –| –| 5211A20020C| –| 5211A20020C| –| R
554031| CONDENSER ASSEMBLY, BENT| 5403A20004B| 5403A20004F| 5403A20004F| 5403A20004F| 5403A20004K| 5403A20004M| R
554160| COMPRESSOR| 5416AR1411D| 5416AR1581C| 5416AR1581C| 5417AR2256E| 5416AR1581C| 1H00404D| R
559010| FAN ASSEMBLY, AXIAL| 5900AR1598A| 5900AR1330A| 5900AR1330A| 5900AR1330A| 5900AR1330A| 5900AR1330A| R
W0CZZ| CAPACITOR| 6120AR2194F| 6120AR2194F| 6120AR2194F| 6120AR2194D| 6120AR2194F| 6120AR2194F| R
W48602| CLAMP SPRING| 3H02932C| 3H02932C| 3H02932C| 3H02932C| 3H02932C| 3H02932C|
W52106-1| TUBE, EVAPORATOR| 5210A30009B| 5210A30009G| 5210A30009G| 5210A30009D| 5210A30009G| 5210A30144A| R
W52106-2| TUBE, EVAPORATOR| 5210A30009A| 5210A30009H| 5210A30009H| 5210A30009C| 5210A30009H| 5210A30144B| R
LOCATION NO .| ****

DESCRIPTION

| PART NO.| ****

REMARK

---|---|---|---
LWN2260 BCG(BCL)| LWM1820/1 BCG(BCL)| LWN2120 BCG(BCL)| LWN2130 BCG(BCL)| LWN2131 BAG
130410| BASE ASSEMBLY, SINGLE| 3041A30002D| 3041A30002B| 3041A30001K| 3041A30001H| 3041A30001H| R
130910| CABINET ASSEMBLY| 3061AR6056B| 3091AR6057B| 3091AR6057B| 3091AR6057B| 3091AR6056B| R
135303| GRILLE, INLET| 3530AR1604A(5236AR1329A)| 3530AR1604A(5236AR1329A)| 3530AR1604A(5236AR1329A)| 3530AR1604A(5236AR1329A)| 3530AR1604A| R
135312| GRILLE ASSEMBLY, FRONT| 3531A20005A(3531AR2632D)| 3531A20005A(3531AR2632D)| 3531A20005A(3531AR2632D)| 3531A20005A(3531AR2632D)| 3531A20005L| R
135500| COVER, CONTROL BOX| 3550AR7245A| 3550AR7245A| 3550AR7245A| 3550AR7245A| 3550AR7245A| R
135510| COVER ASSEMBLY, CONTROL| –| –| –| –| 3551A30015A| R
137215| PANEL ASSEMBLY, CONTROL| 3721A20002A| | 3721A20002E| 3721A20002B| 3721A20002A| R
146812| MOTOR ASSEMBLY, SYNC| 2H01102A| 2H01102A| 2H01102A| 2H01102A| 2H01102A| R
147581-1| LOUVER, HORIZONTAL| 4758A7264A(-)| 4758A7264A(-)| 4758A7264A(-)| 4758A7264A(-)| 4758A7264A(-)| R
147581-2| LOUVER, HORIZONTAL| 4758AR7278A(-)| 4758AR7278A(-)| 4758AR7278A(-)| 4758AR7278A(-)| 4758AR7278A(-)| R
147582| LOUVER, VERTICAL| 4758AR6157A| 4758AR6157A| 4758AR6157A| 4758AR6157A| 4758AR6157A| R
148000| BRACE| 4800AR7271A| 4800AR7272A| | 4800AR7272A| 4800AR7271A| R
149410| KNOB ASSEMBLY| 4941A30001A (4941A30001B)| 4941A30001A (4941A30001B)| 4941A30001A (4941A30001B)| 4941A30001A (4941A30001B)| 4941A30001A| R
149980| SHROUD| 4998AR1597A| 4998AR1597A| 4998AR1597A| 4998AR1597A| 4998AR1597A| R
152302| FILTER ASSEMBLY, A/C| 5231AR6159A(5230AR1327A)| 5231AR6159A(5230AR1327A)| 5231AR6159A(5230AR1327A)| 5231AR6159A(5230AR1327A)| 5231AR6159A| R
249950| CONTROL BOX ASSEMBLY, SINGLE| 4995A20005B/C| 4995A20005G| 4995A20005S| 4995A20005P| 4995A20065J| R
264110| POWER CORD ASSEMBLY| 3H01307C| 3H01307C| 3H01307C| 2H00677Q| 2H00677Q| R
266002| SWITCH, ROCKER| 2H01316C| 2H01316C| 2H01316C| 2H01316C| 2H01316C| R
266003| SWITCH, ROTARY| 2H00598E| 2H00598E| 2H00598E| 2H00598E| 2H00598E| R
269310| THERMOSTAT ASSEMBLY| 2H01109L| 2H01109L| 2H01109M| 2H01109L| 2H01109L| R
346811| MOTOR ASSEMBLY, SINGLE| 4681A20011A| 4681AR6033C| 4681AR6033F| 4681AR6033G| 4681AR6033M| R
349001| DAMPER, VENTILATION| 4900AR7256A| 4900AR7256A| 4900AR7256A| 4900AR7256A| 4900AR7256A| R
349480| ORIFICE| 4948AR7241A| 4948AR7241A| 4948AR7241A| 4948AR7241A| 4948AR7241A| R
349600| MOTOR MOUNT| 4960AR2895A| 4960AR1596A| 4960AR1596A| 4960AR1596A| 4960AR1596A| R
352111| TUBE ASSEMBLY, CONNECTION| 5211AR7059C| 5211AR7059C| 5211AR7059C| 5211AR7059E| 5211AR7059H| R
352113| TUBE ASSEMBLY, DISCHARGE| 5211A30003A| 5211A30066A| 5211A30131A| 5211A30137A| 5211A30293A| R
35211A| TUBE ASSEMBLY, SUCTION| 5211A30064A| 5211A30088B| 5211A30130A| 5211A30136A| 5211A30292A| R
352390| AIR GUIDE ASSEMBLY| 5239A20001A| 5239A20001A| 5239A20001A| 5239A20001A| 5239A20001A| R
354210| EVAPORATOR ASSEMBLY| 5421A20017A| 5421A20017A| 5421A20017A| 5421A20017B| –| R
359012| FAN ASSEMBLY, BLOWER| 5834AR1599A| 5834AR1599A| 5834AR1599A| 5834AR1599A| 5834AR1599A| R
550140| ISOLATOR, COMP| –| –| –| –| –| R
552101| TUBE CAPILLARY| 5424AR3448L| 5425AR3147T| 5425AR3147X| 5424AR3411P| –| R
552102| TUBE, CAPILLARY BEND| –| –| –| –| 5211A30296A| R
554031| CONDENSER ASSEMBLY, BENT| 5403A20004B| 5403A20004F| 5403A20004B| 5403A20013D| 5403A20004T| R
554160| COMPRESSOR| 5416AR1411E| 5417AR2256S| 5416AR1422A| 2H01564J| 5416A20013E| R
559010| FAN ASSEMBLY, AXIAL| 5900AR1598A| 5900AR1330A| 5900AR1330A| 5900AR1508A| 5900AR1330A| R
W0CZZ| CAPACITOR| 6120AR2194L| 6120AR2194P| 6120AR2194F| 6120AR2194D| 6120AR2194K| R
W48602| CLAMP SPRING| 3H02932C| 3H02932C| 3H02932C| 3H02932C| 3H02932C| R
W52106-1| TUBE, EVAPORATOR| 5210A30144B| 5210A30009J| 5210A30144B| 5210A30009D| 5210A30144B| R
W52106-2| TUBE, EVAPORATOR| 5210A30144A| 5210A30009K| 5210A30144A| 5210A30009C| 5210A30144A| R
LOCATION NO .| ****

DESCRIPTION

| PART NO.| ****

REMARK

---|---|---|---
LWN1860 QCG(QCL)| LWN2260 QCG(QCL)| LWM1860 QCG(QCL)| LWM1820/1 QCG(QCL)| LWN2120 QCG(QCL)| LWM1830 QCG(QCL)| LWN2130 QCG(QCL)
135312| FRONT GRILLE ASS’Y| 3531A20005A (3531AR2632D)| R
135313| INLET GRILLE| 3530AR1604A (5236AR1329A)| R
152302| AIR FILTER ASS’Y| 5231AR6159A (5230AR1327A)| R
147581-1| LOUVER HORIZONTAL| 4758AR7264A(-)| R
147581-2| LOUVER HORIZONTAL| 4758AR7278A(-)| R
554160| COMPRESSOR ASS’Y| 5417AR2767F| 5417AR2767G| 5417AR6146E| 5417AR2652B| 2H01277W| 5417AR2652A| 2H02564H| R
130910| CABINET ASS’Y| 3091AR6056B| 3091AR6057B| 3091AR6056B| R
147582| LOUVER VERTICAL| 4758AR6157A| R
349001| DAMPER| 4900AR7265A| R
349600| MOTOR MOUNT| 4960AR1596A| 4960AR2895A| 4960AR4596A| R
346811| MOTOR ASS’Y| 4681AR6033A| 4681A20011A| 4681AR6033H| 4681AR6033C| 4681AR6033F| 4681AR6033B| 4681AR6033G| R
359012| BLOWER| 5834AR1599A| R
352390| AIR GUIDE ASS’Y| 5239A20001A| 5239A20001D| 5239A20001A| R
W48602| CLAMP| 3H02932C| R
349480| ORIFICE| 4948AR7241A| R
354210| EVAPORATOR ASS’Y| 5421A20009A| 5421A20017A| 5421A20009A| 5421A20017A| 5421A20017B| R
149980| SHROUD| 4998AR1597A| R
559011| FAN| 5900AR1598A| 5900AR1330A| 5900AR1508A| 5900AR1330A| R
554031| CONDENSER ASS’Y| 5403A20004B| 5403A20004F| 5403A20004B| 5403A20004F| 5403A20013D| R
148000| BRACE| 4800AR7271A| 4800AR7272A| 4800AR7271A| 4800AR7272A| 4800AR7271A| R
249950| CONTROL BOX ASS’Y| 4995A20045A| 4995A20045B| 4995A20045L| 4995A20045C| R
268712| DISPLAY PWB ASM| 6871A30005A| R
268714| MAIN PWB ASM| 6871A20037H| 6871A20037K| R
W0CZZ| CAPACITOR| 6120AR2194F| 6120AR2194D| 6120AR2194F| 6120AR2194P| 6120AR2194F| 6120AR2194D| R
264110| POWER CORD ASS’Y| 3H01307C| 3H03555B| 3H01307C| 2H00677Q| R
263230| THERMISTOR ASS’Y| 6323AQ2333K| R
237200| CONTROL PANEL| 3720AR6163A| R
238310| ESCUTCHEON| 3841A10002A| 3831A10002B| R
146812| SYNCHRONOUS MOTOR| 2H01102A| R
135500| COVER CONTROL BOX| 3550AR7245A| R
261704| TRANSFORMER ASS’Y| 6171AQ2258F| R
35211A| TUBE SUCTION ASS’Y| 5211A30002A| 5211A30064A| 5211A30154A| 5211A30088B| 521130130A| 5211A30065A| 5211A30136A| R
352113| TUBE DISCHARGE ASS’Y| 5211A30003A| 5211A30066B| 5211A30066A| 5211A30131A| 5211A30066A| 5211A30137A| R
352111| TUBE CONNECTION ASS’Y| 5211AR7059C| 5211AR7059A| 5211AR7059C| 5211AR7059E| R
552101| TUBE CAPILLARY| 5425AR3147A| 5424AR3448L| 3H03750L| 5425AR3147T 5425AR3147X| 3H03750S| 5424AR3411P| R
267110| REMOTE CONTROLLER ASSEMBLY| 6711AR2700B| 6711A20018M

(6711AR2700B)

| 6711A20018M| 6711AR2700L| R
130410| BASE ASSEMBLY, SINGLE| 3041A30001B| 3041A30001D| 3041A30002F| 3041A30002B| 3041A30001K| 3041A30002B| 3041A30001H| R
LOCATION NO.| ****

DESCRIPTION

| PART NO.| ****

REMARK

---|---|---|---
LWM1860QAG| LWM2130AAG| LWM2130BAG
130410| BASE ASSEMBLY, SINGLE| 3041A30002F| 3041A30002B| 3041A30002B| R
130910| CABINET ASSEMBLY, SINGLE| 3091AR6057B| 3091AR6057B| 3091AR6057B| R
135312| GRILLE ASSEMBLY, FRONT(SINGLE)| 3531A20005L| 3531A20005L| 3531A20005L| R
135313| GRILLE, INLET| 3530AR1604A| 3530AR1604A| 3530AR1604A| R
135500| COVER| –| 3550A30048C| 3550A30048C| R
135510| COVER ASSEMBLY, CONTROL(SINGLE)| 3551A30015A| 3551A30015A| 3551A30015A| R
137215| PANEL ASSEMBLY, CONTROL| –| 3721A20035Y| 3721A20002A| R
146812| MOTOR ASSEMBLY, SYNC.| 2H01102A| –| 2H01102A| R
147581-1| LOUVER, HORIZONTAL| 4758AR7264A| 4758AR7264A| 4758AR7264A| R
147581-2| LOUVER, HORIZONTAL| 4758AR7278A| 4758AR7278A| 4758AR7278A| R
147582| LOUVER, VERTICAL| 4758AR6157A| –| 4758AR6157A| R
148000| BRACE| 4800AR7272A| 4800AR7272A| 4800AR7272A| R
149410| KNOB ASSEMBLY| 4940AR7022A| 4941A30001A| 4941A30001A| R
149980| SHROUD| 4998AR1597A| 4998AR1597A| 4998AR1597A| R
152302| FILTER ASSEMBLY, A/C| 5231AR6159A| 5231AR6159A| 5231AR6159A| R
237200| PANEL, CONTROL| 3720AR6163A| –| –| R
238310| ESCUTCHEON| 3831A10002H| –| –| R
249950| CONTROL BOX ASSEMBLY, SINGLE| 4995A20100A| 4995A20088K| 4995A20088M| R
261704| TRANSFORMER, POWER| 6170A20006A| –| –| R
263230| THERMISTOR ASSEMBLY| 6323A20003D| –| –| R
264110| POWER CORD ASSEMBLY| 3H01307C| 2H00677Q| 2H00677Q| R
266002| SWITCH, ROCKER| –| –| 2H01316C| R
266003| SWITCH, ROTARY| –| 2H00598E| 2H00598E| R
267110| REMOTE CONTROLLER ASSEMBLY| 6711A20034N| –| –| R
268712| PWB(PCB) ASSEMBLY, DISPLAY| 6871A20118C| –| –| R
268714| PWB(PCB) ASSEMBLY, MAIN| 6871A10013A| –| –| R
269310| THERMOSTAT ASSEMBLY| –| 2H01109L| 2H01109L| R
346811| MOTOR ASSEMBLY, SINGLE| 4681AR6033H| 4681AR6033U| 4681AR6033U| R
349001| DAMPER, VENTILATION| 4900AR7265A| 4900AR7265A| 4900AR7265A| R
349480| ORIFICE| 4948AR7241A| 4948AR7241A| 4948AR7241A| R
349600| MOUNT, MOTOR| 4960AR1596A| 4960AR1596A| 4960AR1596A| R
352111| TUBE ASSEMBLY, CONNECTOR| 5211AR7059A| 5211AR7059C| 5211AR7059C| R
352113| TUBE ASSEMBLY, DISCHARGE SINGLE| 5211A30066B| 5211A30066L| 5211A30066L| R
W52106-1| TUBE, EVAPORATOR| 5210A30009G| 5210A30144J| 5210A30144J| R
W52106-2| TUBE, EVAPORATOR| 5210A30009H| 5210A30144K| 5210A30144K| R
35211A| TUBE ASSEMBLY, SUCTION SINGLE| 5211A30154A| 5211A30292D| 5211A30292D| R
352390| AIR GUIDE ASSEMBLY| 5239A20001A| 5239A20001C| 5239A20001J| R
354210| EVAPORATOR ASSEMBLY, FIRST| 5421A20009A| 5421A20017G| 5421A20017G| R
359012| FAN ASSEMBLY, BLOWER| 5834AR1599A| 5834AR1599B| 5834AR1599B| R
550140| ISOLATOR, COMP| –| 5040A30017A| 5040A30017A| R
552102| TUBE, CAPILARY BEND| 5211A20020C| 5211A20020T| 5211A20020T| R
554030| CONDENSER ASSEMBLY, FIRST| –| 5403A20004Y| 5403A20004Y| R
554031| CONDENSER ASSEMBLY, BENT| 5403A20004K| –| –| R
554160| COMPRESSOR| 5416AR1581C| 5416A20013E| 5416A20013E| R
559010| FAN ASSEMBLY, AXIAL| 5900AR1330A| 5900AR1330A| 5900AR1330A| R
W0CZZ| CAPACITOR, DRAWING| 6120AR2194F| 6120AR2194K| –| R
W48602| CLAMP, SPRING| 3H02932C| 3H02932C| 3H02932C| R
LOCATION NO.| ****

DESCRIPTION

| PART NO.| ****

REMARK

---|---|---|---
LWN2120BHG| LWN2120BHP| LWN2120QHG| LWN2123BHG
130410| BASE ASSEMBLY,SINGLE| 3041A30001K| 3041A30001K| 3041A30001K| 3041A30001K| R
130910| CABINET ASSEMBLY,SINGLE| 3091AR6056B| 3091AR6056B| 3091AR6056B| 3091AR6056B| R
135312| GRILLE ASSEMBLY,FRONT(SINGLE)| 3531A20005X| 3531A20005U| 3531A20005F| 3531A20005V| R
135313| GRILLE,INLET| 3530AR1604A| 3530A10005B| 3530AR1604A| 3530AR1604D| R
135510| COVER ASSEMBLY,CONTROL(SINGLE)| 3551A30015A| 3551A30015A| 3551A30015A| 3551A30015A| R
137215| PANEL ASSEMBLY,CONTROL| 3721A20002D| 3721A20035H| –| 3721A20035H| R
146812| MOTOR ASSEMBLY,SYNC.| 2H01102A| 2H01102A| 2H01102A| 2H01102A| R
147581-1| LOUVER,HORIZONTAL| 4758AR7264A| 4758AR7264F| 4758AR7264A| 4758AR7264F| R
147581-2| LOUVER,HORIZONTAL| 4758AR7278A| 4758AR7278F| 4758AR7278A| 4758AR7278F| R
147582| LOUVER,VERTICAL| 4758AR6157A| 4758AR6157A| 4758AR6157A| 4758AR6157A| R
148000| BRACE| 4800AR7271A| 4800AR7271A| 4800AR7271A| 4800AR7271A| R
149410| KNOB ASSEMBLY| 4941A30001A| 4941A30001L| –| 4941A30001K| R
149980| SHROUD| 4998AR1597A| 4998AR1597A| 4998AR1597A| 4998AR1597A| R
152302| FILTER ASSY,A/C| 5231AR6159A| 5231AR6159D| 5231AR6159A| 5231AR6159D| R
237200| PANEL,CONTROL| –| –| 3720AR6163A| –| R
238310| ESCUTCHEON| –| –| 3831A20032C| –| R
249950| CONTROL BOX ASSEMBLY,SINGLE| 4995A20032D| 4995A20032R| 4995A20101A| 4995A20032Q| R
261704| TRANSFORMER,POWER| –| –| 6170A20006A| –| R
263230| THERMISTOR ASSEMBLY| 3Q35015N| 3Q35015N| 6323A20003E| 3Q35015N| R
264110| POWER CORD ASSEMBLY| 3H01307C| 3H01307C| 3H01307D| 3H01307C| R
266002| SWITCH,ROCKER| 2H01316C| 2H01316C| –| 2H01316C| R
266003| SWITCH,ROTARY| 2H00598F| 2H00598F| –| 2H00598F| R
267110| REMOTE CONTROLLER ASSEMBLY| –| –| 6711A20018B| –| R
268712| PWB(PCB) ASSEMBLY,DISPLAY| –| –| 6871A20195G| –| R
268714| PWB(PCB) ASSEMBLY,MAIN| –| –| 6871A20188W| –| R
269310| THERMOSTAT ASSEMBLY| 2H01127D| 2H01127D| –| 2H01127D| R
346811| MOTOR ASSEMBLY,SINGLE| 4681AR6033F| 4681AR6033F| 4681AR6033F| 4681AR6033F| R
349001| DAMPER,VENTILATION| 4900AR7265A| 4900AR7265A| 4900AR7265A| 4900AR7265A| R
349480| ORIFICE| 4948AR7241B| 4948AR7241B| 4948AR7241B| 4948AR7241B| R
349600| MOUNT,MOTOR| 4960AR1596A| 4960AR1596A| 4960AR1596A| 4960AR1596A| R
W52106-1| TUBE,EVAPORATOR| 5210A30144E| 5210A30144E| 5210A30144E| 5210A30144E| R
W52106-2| TUBE,EVAPORATOR| 5210A30144F| 5210A30144F| 5210A30144F| 5210A30144F| R
352390| AIR GUIDE ASSEMBLY| 5239A20001B| 5239A20001B| 5239A20001B| 5239A20001B| R
354210| EVAPORATOR ASSEMBLY,FIRST| 5421A20017E| 5421A20017E| 5421A20017E| 5421A20017E| R
359012| FAN ASSEMBLY,BLOWER| 5834AR1599B| 5834AR1599B| 5834AR1599B| 5834AR1599B| R
550140| ISOLATOR,COMP| 4H01765A| 4H01765A| 4H01765A| 4H01765A| R
552101| TUBE,CAPILLARY| 3H03750H| 3H03750H| 3H03750H| 3H03750H| R
554031| CONDENSER ASSEMBLY,BENT| 5403A20013H| 5403A20013H| 5403A20013H| 5403A20013R| R
554160| COMPRESSOR ASSEMBLY| 1H00404D| 1H00404D| 1H00404D| 1H00404D| R
559010| FAN ASSEMBLY,AXIAL| 5900AR1330A| 5900AR1330A| 5900AR1330A| 5900AR1330A| R
W0CZZ| CAPACITOR,DRAWING| 6120AR2194F| 6120AR2194F| 6120AR2194F| 6120AR2194F| R
W48602| CLAMP,SPRING| 3H02932C| 3H02932C| 3H02932C| 3H02932C| R
552116| TUBE ASSY,REVERSING| 5211A30180A| 5211A30180A| 5211A30180A| 5211A30180A| R
552202| VALVE,REVERSING| 3A02027A| 3A02027A| 3A02027A| 3A02027A| R
553000| HEATER,SUMP| 2A00093L| 2A00093L| 2A00093L| 2A00093L| R
561410| COIL ASSEMBLY,REVERSING VALVE| 3A02028Z| 3A02028Z| 3A02028Z| 3A02028Z| R

P/No.: 3828A30001N
October, 2006 Printed in Korea

References