DESCRIPTION

This digital level is a highly versatile leveling tool designed for fast, easy operation

  • Measuring range of digital display: 4×90°
  • Resolution of Digital Display: ±0.01°
  • Precision of Digital Display: ±0.1° at 0° and 90° ±0.2° at other angles
  • Unit of measurement (°degrees / % / mm/m / IN/FT)
  • Backlight
  • Hold function
  • 0°calibration
  • Battery type: 2×1.5V “AAA” batteries
  • Working temperature: 0℃ ~ 40℃
  • Storage temperature: -10℃ ~ 50℃
  • Dimensions: 585832mm
  • Weight: 74g (without battery)

Operation instructions

  1. Battery replacement
    Remove the rear battery cover of the receiver by unscrewing the battery cover retaining screw. The cover will now lift off. Open the battery case. Put two “AAA” batteries and close the case. Your electronic level is now ready to use.

  2. ON/OFF
    Press the ON/OFF button to turn the equipment on. It shows the last mode before shutdown. Hold the ON/OFF button not to put to turn it off. After about 3 minutes not using the equipment, it will switch off automatically.

  3. Turn on the equipment and put it in the level position for measuringNeoteck-NTK033-Digital-Angle-Finder-fig- \(1\)

  4. Unit of measurement selection (°degrees / % / mm/m IN/FT)
    After switching on, the screen always shows the last mode before shutdown. By pressing the MODE button you can change the angles unit display units from degrees (°) to percent (%), to (mm/m) to pitch (in/ft). Pitch readings are in 1/8-inch/fee increments. The icon indicates the current angle’s position, either up or down away from the horizontal or vertical position.

  5. Angle measure
    If the equipment isn’t in level, it will display values on the screen. Press the REF button to set the current angle to zero, enter relative angle measurement mode. The icon will show on the screen. Press the REF button again to cancel the function.

  6. Backlight function
    Press any button, and the backlight of the screen will turn on. The LCD backlight will stay on for approximately 20 seconds with no movement of the level, then it will be turned off automatically.

  7. Hold
    In positions where the display might not be readable, the actual measured value can then be saved by pressing the HOLD button, then a saved measured value is displayed and the icon will show on the screen. By pressing the HOLD button another time, the measuring mode will get reactivated.

  8. Low battery indicator
    Recommend to replace two new “AAA” batteries, when the low Battery indicator “ ” shows on the screen.

User’s calibration

  • Turn off the equipment. Put the equipment on Put the equipment on a flat and smooth solid surface. (see the following figure).
  • In the shutdown status, press and hold the HOLD button first, then press the ON/OFF button, until the LCD display reads “CAL”.
  • Keep the equipment still for a period of time and then press the HOLD button, the display reads “CAL1”.
  • In the same location, rotate the equipment 180° (see the following figure), then press the HOLD button, the display reads “CAL2”. After the “CAL2” disappears, the calibration is completed and then the LCD will show the current angle in high-accuracy-display

NOTE:

  • The calibration must be performed on a flat and smooth surface with a tilt of no more than 5°. If it exceeds 5°, the display reads “Err”, which indicates the user can’t proceed to do the calibration.
  • During calibrating, the level also can not be beveled or moved.
  • After completed calibration, the equipment automatically replaces from original factory data to the consumer’s data, so it must be careful to use this function

Caution Please turn off the item when it is not in use in order to prolong its working life.

Warranty

Thanks for using Neoteck products all neoteck product comes with a warranty of 18 months from the day of purchase, if you need any support, please feel free to contact us.

Contact

Email: neoteckservice@gmail.com

FREQUENTLY ASKED QUESTIONS

What is the price of the Neoteck NTK033 Digital Angle Finder?

The Neoteck NTK033 Digital Angle Finder is priced at $20.59.

What are the dimensions of the Neoteck NTK033 Digital Angle Finder?

The dimensions of the Neoteck NTK033 Digital Angle Finder are 2.28 x 2.28 x 1.26 inches.

How much does the Neoteck NTK033 Digital Angle Finder weigh?

The Neoteck NTK033 Digital Angle Finder weighs 4.23 ounces.

Who is the manufacturer of the Neoteck NTK033 Digital Angle Finder?

The manufacturer of the Neoteck NTK033 Digital Angle Finder is VARUN.

What is the warranty period for the Neoteck NTK033 Digital Angle Finder?

The Neoteck NTK033 Digital Angle Finder comes with an 18-month warranty.

What is the operation mode of the Neoteck NTK033 Digital Angle Finder?

The operation mode of the Neoteck NTK033 Digital Angle Finder is automatic, making it user-friendly and convenient for various applications.

What type of batteries does the Neoteck NTK033 Digital Angle Finder require?

The Neoteck NTK033 Digital Angle Finder requires 2 AAA batteries to operate.

Why isn't my Neoteck NTK033 Digital Angle Finder turning on?

Ensure that the battery is installed correctly and is not depleted. Check for any corrosion on the battery contacts and clean if necessary. Replace the battery if needed.

How do I reset my Neoteck NTK033 Digital Angle Finder if it malfunctions?

To reset the angle finder, remove the battery, wait for 10 seconds, and then reinsert it. This should reset the device and resolve minor issues.

The display on my Neoteck NTK033 Digital Angle Finder is dim or not visible. What should I do?

A dim or invisible display usually indicates low battery power. Replace the battery with a new one to see if this resolves the issue.

How can I clean my Neoteck NTK033 Digital Angle Finder?

Use a soft, dry cloth to clean the exterior of the angle finder. Avoid using water or cleaning agents that could damage the electronic components. Ensure the device is turned off before cleaning.

The buttons on my Neoteck NTK033 Digital Angle Finder are not responding. What can I do?

Ensure that the buttons are not obstructed or stuck. Check if the device needs a reset by removing and reinserting the battery. If the problem continues, the buttons may be faulty and require professional repair.

How do I replace the battery in my Neoteck NTK033 Digital Angle Finder?

Locate the battery compartment on the device. Open the compartment, remove the old battery, and insert a new one, ensuring it is oriented correctly according to the polarity markings.

Why does my Neoteck NTK033 Digital Angle Finder shut off unexpectedly?

Unexpected shutdowns can be due to low battery power or loose battery connections. Ensure the battery is firmly in place and replace it if necessary. If the issue persists, there may be an internal fault that needs professional attention.