Specifications
- Manufacturer: [Manufacturer Name]
- Model: [Model Number]
- Power Supply: Main electrical power adapter model No. ESCM01T8-050
- Connectivity: App-based
- Features: Pairing functionality, LED indicators, measurement transmission
Product Usage Instructions
Ensure the following items are included in the box:
- Main box
- IGS (Intelligent Ground Sensor)
- Power adapter
The product is a Connected Bait System consisting of a main box and IGS units. Follow these steps to set up the product:
- Plug the main box power supply.
- Launch the app and pair it with the main box by scanning the Pairing QR code.
- Distribute the IGS units around the building every 3 meters.
- Dig holes for the IGS units.
- Insert the cartridges in the loop of each IGS unit.
- Pair each IGS unit one after the other by pressing the Pairing button.
- Scan the QR code with the app for each IGS unit.
- Insert the IGS units into the ground.
Maintenance and Cleaning
- Regularly clean the product using a damp cloth. Avoid using harsh chemicals that may damage the components.
FAQ
- How do I reset the product?
- To reset the product, press and hold the Reset button for 8 seconds until the LED indicator flashes green.
- What should I do if the LED indicator shows a specific color?
- If the LED indicator is red, press the button for 2 seconds. If it is blue, press and hold the button for 2 seconds. If it flashes dark blue, wait for normal operation or an update process to complete.
Dear Customer, Thank you for choosing Novaterm® from Groupe Berkem. For safe use, we advise you to read its quick start guide very carefully and follow all instructions. The contents of this quick start guide cannot exhaustively describe all aspects related to the use of the product. It is based on our own experience and remains non-binding. It does not evade compliance with the information indicated in the Safety Data Sheet available on request. The information in this documentation is indicated in the current state of the regulations. Any changes to these regulations will result in an update of this document. If you have any questions, your sales representative is available to answer them and take note of any suggestions you may have.
Manufacturer
- NOVATERM® products are manufactured by GROUPE BERKEM
- Address: 20, rue Jean DUVERT – 33290 BLANQUEFORT – France
- Telephone: +33 5 64 31 06 60
- Web site: https://hygiene.groupeberkem.com and novaterm.com
Please carefully read the manual and the “Safety” chapter before use.
Contents of the box
868 MHz or 921 MHz NOVATERM® IGS | 868 MHz or 921 MHz NOVATERM® BOX |
---|
• One user manual and safety instructions
• 16 NOVATERM® IGS
•16 main units or boxes
•16 loops or cartridge supports
•16 reclosable covers
| • One user manual and safety instructions
• One main electrical power adapter SIMSUKIAN ESCM01T8-050
• One NOVATERM® BOX
Presentation of the product
- The NOVATERM® IGS and NOVATERM® BOX are intended to be used by professionals to deal with subterranean termites.
- The NOVATERM® IGS are installed in the ground approximately 50 cm to 1 meter from the edges of buildings, approximately every 3 meters.
- Two anti-termite bait cartridges can be inserted in a loop in the interior cavity of the NOVATERM® IGS.
- The NOVATERM® IGS features a proprietary 868 MHz or 921 MHz radio telecommunication and measurement system, depending on the country.
- When the system is installed, the NOVATERM® IGS stations are paired with one or more NOVATERM® BOX units. The NOVATERM® BOX has a range of about 50 m, which may be reduced due to obstacles (concrete walls, metal partitions, etc.).
- The measurements are transmitted to the NOVATERM® BOX, which then sends them to a server over an LTEM / NB-IOT-type telecommunication network for analysis.
868 MHz or 921 MHz NOVATERM® IGS
- Pairing and ON button
- Status LED
- Pairing QR code
868 MHz or 921 MHz NOVATERM® BOX
- Pairing button
- Status LED
- Socket for main electrical power adapter model No. ESCM01T8-050
- Pairing QR code
CONNECTED BAIT SYSTEM
- Plug the main box power supply
DISTRIBUTE THE IGS AROUND
- THE BUILDING EVERY 3 METERS
DIG THE HOLES
SETUP IGS
- MISE EN PLACE IGS
FEATURES
868 MHz or 921 MHz NOVATERM® IGS
Step| Required action| LED| Comment
Forced transmission of a measurement| Press the button| | Transmission of a
message if the station is paired, then return to standby mode
Start the pairing process| 2 seconds ≤ press the button ≤ 8 seconds| The LED
flashes red| The telecommunication module is not connected
Reset| Press and hold the button ≥ 8 seconds| The LED is green| Reset with
factory settings
868 MHz or 921 MHz NOVATERM® BOX
Step Required action LED Comment
Forced transmission of a measurement| Press and hold the button (≥ 2 seconds)|
The LED is blue| Goes off after 120 seconds
Start-up| | The LED flashes dark blue| The telecommunication module is not
yet connected
Normal operation| | The LED is green| The telecommunication module is
connected
During an update| | The LED flashes dark blue| Update in progress
After an update| | The LED is white for 1 second, followed
by start-up
| Update complete
Maintenance and Cleaning
868 MHz or 921 MHz NOVATERM® IGS
- Inspect your NOVATERM® IGS at least once a year. Clean the IGS after each inspection.
868 MHz or 921 MHz NOVATERM® BOX
- Clean your NOVATERM® BOX at least once a year. The exterior of the BOX can be cleaned with a cloth to wipe off dust.
- In the event of a failure, contact NOVATERM® customer service. Do not attempt to access the electronic circuit.
- In the event of regular losses of data, position the NOVATERM® BOX in another location or at a different height. Technical characteristics
868 MHz or 921 MHz NOVATERM® IGS
- Supply voltage: 3.0 V
- Consumed current: 50 mA max.
- Power: 150 mW max.
- Battery: Primary, CR2477X (lithium)
- Electric shock protection class: III
- Weight without consumables: 0.5 kg
- Dimensions (l x w x h): 150 x 150 x 250 mm
- Product casing: ABS plastic and polyurethane resin
- Frequency bands:
- 866 MHz (for the 868 MHz version)
- 921 MHz (for the 921 MHz version)
868 MHz or 921 MHz NOVATERM® BOX
- Product power supply: The main electrical power adapter included
- Supply voltage: 5 V.
- Current: 2.5 A max.
- Power: 12.5 W
- Electric shock protection class: III
- Weight: 0.25 kg
- Size / Dimensions (l x w x h): 0.1 x 0.07 x 0.03 m
- Frequency bands:
- 866 MHz (for the 868 MHz version)
- 921 MHz (for the 921 MHz version)
- CAT M1: LTE HD-FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/ B25/B26/B27/B28/B66/B85
- CAT NB2: LTE HD-FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/ B25/B28/B66/B71/B85
- EGPRS: GSM850/EGSM900/DCS1800/PCS1900
Main electrical power adapter included with the NOVATERM® BOX – SIMSUKIAN – SK01T8-0500300Z
- Nominal input voltage: 110-220 VAC
- Minimum and maximum input voltages: 90 – 264 VAC
- Main electrical power frequency range: 47 Hz – 63 Hz
- Output voltage: 5.0 V
- Maximum input current: 0.4 A
- Maximum inrush current: 100 A (typical value with a voltage of 220 VAC)
- Max. output current: 3 A
- Max. power: 15 W
- Electric shock protection class: II
- Input connectors: UL/PSE, CE, SAA, CCC
- Output connector: Plus 5.1 mm x 2.1 mm x 0.5 mm (center positive)
- Length of the output cable: 1.5 m
Operating conditions 868 MHz or 921 MHz NOVATERM® IGS
- Operating temperature -10 °C to +40 °C
- Outdoor equipment = pollution degree 4
- Altitude: < 2,000 m
- Relative humidity < 80 % without condensation.
Operating conditions 868 MHz or 921 MHz NOVATERM® BOX
- Operating temperature -10 °C to +40 °C
- Outdoor equipment = pollution degree 2
- Altitude: < 2,000 m
- Relative humidity < 80 % without condensation.
Certification and regulatory information CE certification
-
Groupe Berkem declares that the NOVATERM® BOX 868 MHz and NOVATERM® IGS 868 MHz type radio electrical equipment comply with the directive 2014/53/EU.
-
These devices meet Standard RoHS 2011/65/EC. These devices do not contain any substances that exceed the maximum concentration values (“MCV”) specified in the EU RoHS directive.
-
Go to the page https://hygiene.groupeberkem.com/en/documents/ to view the Declaration of Conformity.
FCC Statement
Regarding the following equipment:
- NOVATERM® BOX 921 MHz – FCC ID: 2BEZD-NBOXV04
- NOVATERM® IGS 921 MHz – FCC ID: 2BEZD-NIGSV04
GROUPE BERKEM is not responsible for any changes or modifications not
expressly approved by the party responsible for compliance. Such modification
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, according to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
This device must be professionally installed
This equipment complies with FCC’s radiation exposure limits set forth for an uncontrolled environment under the following conditions:
- This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and the user’s/nearby person’s body at all times.
- This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Safety
Definition of symbols
- Risk of danger. Important information. Read the manual
- WEEE logo. This product complies with the marking requirements of the WEEE directive (2002/96/EC). This logo means that you must not dispose of this electrical/electronic product with household waste. Product category: Under the types of equipment in Annex I of the WEEE directive, this is a category 9 product. Do not dispose of this product as unsorted municipal waste.
- FCC logo. Compliant with the applicable limits in part 15 of the FCC rules.
- CE logo. Compliant with the European directives.
Important safety instructions
Please carefully read these safety instructions to use your devices correctly and in complete safety.
- The products in the NOVATERM® range must be handled by professional and qualified operators.
- Only use the products in the NOVATERM® range under the manufacturer’s instructions. In the event of use that does not comply with this manual, the protection provided by the device may be compromised.
- Check the products before installing them. If the product is damaged or shows signs of deterioration, do not use it and contact the after-sales service.
- Do not remove or reuse the battery.
- Never try to repair a damaged device. Contact the after-sales service.
- The NOVATERM® IGS 868 MHz and 921 MHz can be used in humid environments.
- The NOVATERM® BOX 868 MHz and 921 MHz must be stored in a sheltered place, under the operating conditions.
- Never try to connect a damaged device to the main electrical power. Contact the after-sales service.
- Keep the products out of the sight and reach of children and pets.
- Obey local and national safety rules when installing and using the product.
- Always use the main electrical power adapter supplied with the NOVATERM® BOX. If the power cable or the adapter appears to be damaged, do not use the equipment and contact after-sales service. Do not try to repair the product.
- If the main electrical power socket is damaged or does not comply with the local and national safety rules, do not connect the main electrical power adapter.
Precautions for use of the device
The NOVATERM® IGS is compatible with NOVATERM® CARTRIDGES bait
User safety
- Please apply standard hygiene precautions. Avoid any contact with the skin, eyes, and clothing. Do not eat, drink or smoke when working.
- We recommend the use of latex gloves.
Safety of persons
- Always close the NOVATERM® IGS with the NOVATERM® KEY until you hear the cover click into place.
- Always close the NOVATERM® AGS using the cover and the screws with a special head provided.
Storage
- Keep the original recipient hermetically closed and in a dry place, sheltered from light and humidity.
- Keep the product under standard temperature conditions, sheltered from frost. Make sure that the place of storage is sufficiently ventilated.
- Keep well clear of food and drink, including those for animals. Do not store or transport in the vicinity of miscellaneous chemicals or wood treatment products.
- Service = 2 years.
Environment
- Product residue, packaging materials, and any other waste produced by the treatment must be considered as hazardous, under the full responsibility of the owner of the waste, and treated in a specialized facility, by the regulations in force.
- Do not dispose of the biocide in plumbing (sinks, toilets, etc.), gutters or waterways.
- Dispose of any unused product, its packaging, and all other waste in an appropriate collection channel.
After-sales service and warranty
After-sales service
- For all information about NOVATERM products and their conditions of installation and maintenance, please call +33 (0)564 310 660.
CONTACT
- 20, rue Jean Duvert
- 33290 Blanquefort – FRANCE
- groupeberkem@berkem.com
- hygiene.groupeberkem.com
References
- Hygiène & Protection - Groupe Berkem
- novaterm.com
- Hygiène & Protection - Groupe Berkem
- Files - Groupe Berkem
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>