Installation in 3 simple steps
Specifications
Frequency: 433.39 MHz.
Security: 128-bit AES encryption.
Range: up to 50 yards.
Battery life: up to 10 years.
Battery type: 14500 mA battery.
STEP 1:
Coding e-LOOP into e-Trans 50
Coding e-LOOP without magnet
- Power up the e-TRANS-50 and hold the e-Loop within 10cm of the transceiver’s antenna.
- Now press and release the CODE button on the e-Trans 50. The yellow and red LEDs will flash on the e-Loop, and the blue LED on the e-TRANS-50 will flash 3 times. The systems are now paired.
NOTE: For coding e-TRANS-200 LCD transceivers, refer to e-TRANS-200 manual.
Coding e-LOOP without magnet
- Power up the e-TRANS-50, then press and release the CODE button. The blue LED on the e-TRANS-50 will light up.
- Now place the magnet on the CODE recess on the eLoop – the yellow LED will flash 3 times, and the blue LED on the e-Trans 50 will flash 3 times. The systems are now paired and you can remove the magnet.
DISCLAIMER: UNITS WITH THE PRESENCE FEATURE IS NOT TO BE USED AS A SOLE SAFETY DEVICE & SHOULD BE USED IN CONJUNCTION WITH STANDARD GATE SAFETY PRACTICES.
STEP 2:
Fitting e-LOOP
(Refer to diagram below)
- Drill 3.5’’ hole 2.5’’ – 2.7’’ deep. Ensure hole is clean and dry before fitting.
- Measure down before inserting the e-LOOP to ensure it will fit flush with the driveway surface, then pour sikaflex or similar compound into the base of hole.
- Insert the e-LOOP by pushing down until flush with driveway surface.
NOTE: Never fit near high voltage cables, this can affect the e-LOOP’s detection capability.
STEP 3:
Calibrate e-LOOP
- Move any metal objects away from the e-LOOP.
- Place magnet into the SET button recess on the eLOOP until the red LED flashes twice, then remove the magnet.
- The e-LOOP will take about 5 seconds to calibrate and once complete, the red LED will flash 3 times.
The system is now ready.
NOTE: After calibration, you may get an error indication.
ERROR 1: Low radio range – yellow LED flashes 3 times before red LED
flashes 3 times.
ERROR 2: No radio connection – yellow and red LED flashes 3 times before
red LED flashes 3 times.
Uncalibrate e-LOOP
- Place magnet into the SET button recess until red LED flashes 4 times, e-LOOP is now uncalibrated.
Changing mode
You can change the mode by using the e-TRANS-200 LCD transceiver or diagnostic
remote ED00R – refer to manual.
NOTE: This menu cannot be accessed via the e-TRANS-50
Transceiver.
The e-LOOP EL00IG is set to EXIT mode (this can’t be changed).
Parameters that can be altered:
- Activation detection level.
- X, Y, Z axis sensitivity.
Parameters that can be altered on EL00IGRAD:
-
Mode is set to PRESENCE but can be changed to EXIT mode.
NOTE: do not use presence mode as a personal safety device. -
Activation detection level
-
X, Y, Z axis sensitivity
-
Radar read time
-
Release trip point
-
Start lens detection range
-
Measure lens detection range
-
Radar trip sensitivity
-
Radar confirm ON/OFF