AESE EL00IG Wireless Vehicle Detection System Instructions

June 8, 2024
AESE

Wireless Vehicle Detection System
EL00IG and EL00IG-RAD
Installation in 3 simple steps

Specifications

Frequency: 433.39 MHz.
Security: 128-bit AES encryption.
Range: up to 50 yards.
Battery life: up to 10 years.
Battery type: 14500 mA battery.
STEP 1:

Coding e-LOOP into e-Trans 50

Coding e-LOOP without magnet

  1. Power up the e-TRANS-50 and hold the e-Loop within 10cm of the transceiver’s antenna.
  2. Now press and release the CODE button on the e-Trans 50. The yellow and red LEDs will flash on the e-Loop, and the blue LED on the e-TRANS-50 will flash 3 times. The systems are now paired.

NOTE: For coding e-TRANS-200 LCD transceivers, refer to e-TRANS-200 manual.

Coding e-LOOP without magnet

  1. Power up the e-TRANS-50, then press and release the CODE button. The blue LED on the e-TRANS-50 will light up.
  2. Now place the magnet on the CODE recess on the eLoop – the yellow LED will flash 3 times, and the blue LED on the e-Trans 50 will flash 3 times. The systems are now paired and you can remove the magnet.

DISCLAIMER: UNITS WITH THE PRESENCE FEATURE IS NOT TO BE USED AS A SOLE SAFETY DEVICE & SHOULD BE USED IN CONJUNCTION WITH STANDARD GATE SAFETY PRACTICES.

STEP 2:

Fitting e-LOOP

(Refer to diagram below)

  1. Drill 3.5’’ hole 2.5’’ – 2.7’’ deep. Ensure hole is clean and dry before fitting.
  2. Measure down before inserting the e-LOOP to ensure it will fit flush with the driveway surface, then pour sikaflex or similar compound into the base of hole.
  3. Insert the e-LOOP by pushing down until flush with driveway surface.

NOTE: Never fit near high voltage cables, this can affect the e-LOOP’s detection capability.

STEP 3:

Calibrate e-LOOP

  1. Move any metal objects away from the e-LOOP.
  2. Place magnet into the SET button recess on the eLOOP until the red LED flashes twice, then remove the magnet.
  3. The e-LOOP will take about 5 seconds to calibrate and once complete, the red LED will flash 3 times.

The system is now ready.
NOTE:
After calibration, you may get an error indication.
ERROR 1: Low radio range – yellow LED flashes 3 times before red LED flashes 3 times.
ERROR 2: No radio connection – yellow and red LED flashes 3 times before red LED flashes 3 times.

Uncalibrate e-LOOP

  1. Place magnet into the SET button recess until red LED flashes 4 times, e-LOOP is now uncalibrated.

Changing mode
You can change the mode by using the e-TRANS-200 LCD transceiver or diagnostic remote ED00R – refer to manual.
NOTE: This menu cannot be accessed via the e-TRANS-50
Transceiver.
The e-LOOP EL00IG is set to EXIT mode (this can’t be changed).

Parameters that can be altered:

  1. Activation detection level.
  2. X, Y, Z axis sensitivity.

Parameters that can be altered on EL00IGRAD:

  1. Mode is set to PRESENCE but can be changed to EXIT mode.
    NOTE: do not use presence mode as a personal safety device.

  2. Activation detection level

  3. X, Y, Z axis sensitivity

  4. Radar read time

  5. Release trip point

  6. Start lens detection range

  7. Measure lens detection range

  8. Radar trip sensitivity

  9. Radar confirm ON/OFF

E. sales@aesglobalus.com
T: +1 – 321 – 900 – 4599
www.aesglobalus.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals