ADVATEK R4D-S PixLite Receiver User Manual
- June 3, 2024
- ADVATEK
Table of Contents
ADVATEK R4D-S PixLite Receiver
Introduction
This is the user manual for the PixLite R4D-S pixel receiver, hardware version
1.3.
The PixLite R4D-S is designed to receive differential long distance signals of
300m (1000′) or more over a standard network cable from a PixLite T8
transmitter unit, and convert these input signals back into a pixel-ready
signal for output directly to pixels. The PixLite R4D-S features 4 data-only
outputs, each having both a dedicated fuse and ‘fuse good’ LED indicator.
The PixLite R4D- S features a sleek, compact design and 4 holes for ease of wall mounting as well as an optional DIN rail mounting kit. It also features industrial grade protection on all inputs and outputs, making it the ideal option for reliable commercial and industrial applications.
This manual covers physical aspects of the PixLite R4D-S receiver and its
essential setup steps only. Separate user manuals are available for the
transmitter units. Other manuals may be downloaded from here:
www.advateklights.com/downloads
Safety Notes
This LED pixel receiver should be installed by someone with proper technical
knowledge only. Installation of the device and/or replacement of pixel output
fuses should not be attempted without such knowledge.
Specification and certification markings are located on the the device.
Physical Installation
Wall Mount
Assemble the unit onto the wall/ceiling using four screws of a type suitable
for the mounting surface (not supplied). The screws should be a pan head type,
3mm in thread diameter and at least 15mm long, as shown in Figure 1 below.
DIN Rail Mount
The receiver can be mounted to a DIN rail using the optional mounting kit
(part number MNT0101).
- Align the receiver’s mounting holes with the outermost mounting holes on each bracket. Using the four supplied M3, 12mm long screws, assemble the receiver to the mounting brackets, as shown in Figure 2 below.
- Align the lower edge of the bracket with the lower edge of the DIN rail (1), and push the receiver down so it clicks onto the DIN rail (2), as shown in Figure 3 below.
- To remove the receiver from the DIN rail, pull the receiver horizontally, toward its power connector (1) and rotate the receiver up and off the rail (2), as shown in Figure 4 below.
Electrical Connections
Supplying Power
Power is applied to the PixLite R4D-S via the large lever clamp connector. The
levers should be lifted up for wire insertion and then clamped back down,
providing a highly robust and secure connection. Ensure the wire’s insulation
is stripped back 11-12mm, so that the clamp does not rest on the insulation
when closing the connector. Polarity for the connector is clearly marked on
the lid, as shown in Figure 5 below. The type of wire required for supply
connection is 4.0mm2, 10AWG, VW-1.
Output Fuses & Power Injection
Each individual output is protected by a mini blade fuse. The PixLite R4D-S
comes with 7.5A fuses by default. You may use any value of fuse, up to and
including 7.5A, depending on your specific application. Individual outputs
should not exceed 7.5A and the total current should not exceed 30A. If your
application requires more current than this, then you will need to inject
power into the pixels directly.
The number of pixels that can be physically powered through this device may
not be as high as the amount of pixel control data that is being output. There
is no definitive rule as to how many pixels can be powered from the receiver,
as it depends on the type of pixel. You need to consider if your pixel load
will draw more than 7.5A of current and whether there will be too much voltage
drop in the pixel load for it to only be powered from one end. If you need to
“inject power” we recommend bypassing the receiver’s power output pins
entirely.
If a fuse needs replacing, a suitable replacement fuse is of type “F7.5A E
32V”. An additional spare fuse is also provided for quick replacement which
can be accessed by opening the lid, as shown in Figure 6 below.
No on- board power configuration is required. Power to the logic circuitry is automatically regulated from the power input. Simply connect your DC power supply in accordance with specifications listed in Section 7.1 to the power screw terminal, as shown in Figure 5 above.
Data Input
Data is connected via a standard network cable into the RJ45 jack located on
the front panel of the unit, as shown in Figure 7 below.
Receivers are connected to the transmitter via the RJ45 jacks on the rear panel of the PixLite T8. Each jack is labelled with its output number 1-8. These ports are not network ports, and should not be connected to any networking equipment, as shown in Figure 8 below. They are specifically designed to connect a PixLite transmitter with a PixLite receiver. For this reason, the standard network cable you use can be safely used in excess of 300m.
A typical setup is shown in Figure 9 below, which also shows how many pixels can be run off each output.
Connecting Pixel LEDs
The pixel lights are connected directly via the 4 pluggable screw terminal
connectors on the rear of the unit. Each connector is labelled with its output
channel number (1-4) and on the top of the lid the pin-out is clearly marked.
Simply wire your lights into each screw terminal and then plug them into the
mating sockets.
Since the PixLite R4D-S product has data only outputs (no pixel clock lines),
it takes advantage of the transmitter’s Expanded Mode. In expanded mode, the
clock lines are used as data lines instead. This means the receiver
effectively has twice as many pixel outputs than the PixLite R2 (4), but half
as many pixels per output can be run.
The cable length between the output and the first pixel should not exceed 15m.
Operation
Start-up
When power is applied to the receiver, the green power led in the bottom
right-hand corner on the front panel should be illuminated, as shown in Figure
11 below.
Figure 11: Position of the Power LED
If pixels have been correctly connected to the outputs and the data cable is connected to the transmitter and valid data is being sent, you should see the pixels turn on.
Indicator LEDs
Each fuse is paired with a green LED which indicates the condition of the
fuse. If the fuse is good, the LED will be on. If the fuse has been blown or
is not connected, the LED will be off. This feature offers a quick method for
determining the state of each fuse, however in environments where these LEDs
are needed to be turned off, a switch is located underneath the spare fuse
that will turn off this feature. If the switch is pushed to the right, it is
off, and all indicator LEDs and the power LED will always be off. This switch
is shown in Figure 12 below.
Outputs
The number of pixels per output is configured in the transmitter device and
may vary depending on the pixel capacity of the specific device.
The refresh rate of the pixels will depend on the operating frequency of the
specific pixel chip type. Refer to the user manual of the PixLite Transmitter
device for more information about this topic as the Transmitter will be
responsible for the refresh rate of this receiver.
Specifications
Operating Specifications
The table below specifies the recommended operating conditions for a PixLite
R4D-S receiver.
Parameter | Value/Range | Units |
---|---|---|
Input Voltage Range | 5-24 | V DC |
Max Current | 30 | A |
Max Logic Current Consumption @ 5V | 150 | mA |
Ambient Operating Temperature | -20 to +55 | °C |
Maximum Current Per Pixel Output | 7.5 | A |
Mechanical Specifications
The PixLite R4D-S receiver has dimensions as below.
Dimension | Metric | Imperial |
---|---|---|
Length | 95mm | 3.7″ |
Width | 78mm | 3.1″ |
Height | 33mm | 1.3″ |
Weight | 0.2kg | 0.4lbs |
Fault Protection
The PixLite R4D-S features notable protection from potential damage due to
various types of faults. This makes the device extremely robust and reliably
able to withstand installation and operation even in harsh environments.
ESD protection is present on all data input lines and on all pixel output
lines.
The data input port is protected against shorts to external voltages of up to
+/- 24V.
All pixel output lines are protected against direct shorts of up to +/- 24V.
This means that even if your pixels or wiring have a fault that causes a
direct short between the power and data or clock lines on any output, it will
not damage the device.
The PixLite R4D-S itself is protected against damage from reversed polarity
power input. However it does not provide external reverse polarity protection
for any loads that you may have connected to the pixel outputs.
Troubleshooting
No Power LED
Ensure that your power supply is supplying correct voltage. Additionally,
ensure that it can supply enough current to drive the lights that are
connected. You should also try disconnecting all outputs and see if the
receiver then turns on.
No Pixel Control
Check that the correct pixel IC type has been selected on the transmitter unit
in the dropdown box in the Advatek Assistant under the ‘LEDs’ tab. Also check
the physical wiring and pinout of the pixels, as well as the output fuses.
Ensure that the green ‘fuse good’ indicator LEDs under the lid compartment are
all visible (one per output channel). If any are off, replace any blown output
fuses as required.
Other Issues
For the latest more specific troubleshooting information and other help, you
should refer to our online knowledgebase here: www.advateklights.com
/knowledge-base
If you can’t resolve your problem with the help of our knowledgebase, you can
send an e-mail to:
support@advateklights.com and a support
ticket will automatically be created for you, or you can manually open a
support ticket here:
www.advateklights.com/support
Disclaimer
If you require support or warranty, please refer to Section 8.3 for
information on creating a support ticket. You must be issued with a return
authorization by Advatek support staff before returning any product.
The PixLite R4D- S receiver is supplied with a 3 – year limited warranty and a
repair/replacement guarantee. Please see the terms and conditions on our
website for more information.
The PixLite R4D-S has been tested against and independently certified as compliant with the Standards listed in the table below.
Audio/Video and ICTE – Safety Requirements | UL 62368-1 |
---|---|
Radiated Emissions | EN 55032 & FCC |
Part 15
Immunity for ITE
EN 55024
| Electrostatic Discharge| EN 61000-4-2
Radiated Immunity| EN 61000-4-3
Power Frequency Magnetic Field Immunity| EN 61000-4-8
Restriction of Hazardous Substances| RoHS 3
Through testing to the above standards, the PixLite R4D-S has the certifications and marks listed in the table below.
Certification | Relevant Country |
---|---|
ETL Listing | North America and Canada. Equivalent to UL Listing. |
CE | Europe |
FCC | North America |
ICES3 | Canada |
RCM | Australia and New Zealand |
UKCA | United Kingdom |
Warning : Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at their own expense.
This product has been manufactured by:
Advatek Lighting Pty Ltd
16 / 52 Corporate Blvd
Bayswater, 3153
VIC, AUSTRALIA
www.advateklights.com
PixLite R4D-S User Manual V20220627
References
- Professional LED pixel control solutions - Advatek
- Downloadable product resources, software and firmware updates - Advatek
- Articles, inspiration and information for switched-on lighting professionals - Advatek
- Contact Us - Advatek
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>