READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE
ATTENTION INSTALLER:
This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from This product must be installed in compliance with all local, state and federal codes.
AUTOMATIC HUMIDIFIER MODEL 600
WARNING
-
ELECTRICAL SHOCK HAZARD.
Disconnect electrical power to the furnace before starting installation. Failure to do so could result in serious injury from electrical shock. -
SHARP EDGES HAZARD. Sharp edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork.
-
RISK OF SCALDING. Water temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line.
CAUTION
- Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home.
- Do not install humidifier or bypass connection on the furnace jacket.
- Do not install humidifier or bypass connection on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier.
- Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home.
- Do not connect Model 600 transformer to blower motor wiring. Premature component failure may result.
- When installing Humidifier Control on downflow furnace, ensure blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Control.
- Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction.
- Do not install humidifier on systems with greater than 0.4 in. wg pressure differential between supply and return plenums.
SPECIFICATIONS
HUMIDIFIER Width (including Height (including
BYPASS PLENUM 97⁄
WATER ELECTRICAL
24 VAC
WIRING DIAGRAM
(SEE STEP 8 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS)
INSTALLATION OPTIONS
The Model 600 Aprilaire can be installed on either the supply or return plenum of a forced air handling system and is easily reversible for installation with right hand or left hand bypass duct connections. The humidifier dimensions and serviceability must be considered when selecting the best location for the humidifier examples of many types of installations.
READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFOR
1. Remove front cover by pressing center tabs on top and bottom of the cover (1) and base (2). Pull feed tube (3) out of the water distribution tray (4). Tip the Water Panel® Evaporator assembly forward and lift it out of the humidifier. (See Figure 1)
2. The humidifier comes assembled for left side discharge. If converting to
right side discharge, the base can be rotated so round collar is facing to the
right. Swap the location of the hole plug (10) and drain spud (9) if using a
right side discharge. To remove the cap, push and twist from inside the
housing while lifting the cap up slightly on the outside. To remove the drain
spud, twist and push from the outside of the base.
3. Using a level, position this template at least 3 inches above the furnace
housing or cooling coil, if applicable, for clearance of the drain line. Trace
around template edges. Remove the template and accurately cut the plenum
opening 97⁄8” x 12 5⁄8”, being careful to avoid injury from sharp edges.
4. Place the humidifier into the plenum opening, install six sheet metal
mounting screws (not furnished) at the top and sides of the humidifier
interior.
5. Install a 6” collar in a convenient location on the opposite plenum.
Attach a 90° elbow and measure the length of 6” round duct required to make
the connection. The design of the humidifier collar provides a solid
connection with the bypass duct through the use of inside support ribs and
pre-formed holes for sheet metal screws. Slip the duct inside the collar of
the humidifier, up to the support ribs. Using the pre-formed holes at the top
and bottom of the humidifier collar, secure the duct to the humidifier collar
with two sheet metal mounting screws (not furnished). Support bypass ducts
longer than 4 feet to prevent sagging.
6. Reinstall the Water Panel® Evaporator assembly back into the base, with
the bottom of the scale control insert (6) sitting firmly in the inside of the
drain spud (9). Push the feed tube back into the water distribution tray. (See
Figure 2) Put the front cover back on. If the nameplate (11) is upside down,
remove it by gently squeezing the tabs of the nameplate from inside the cover
and pushing out. Rotate the nameplate so it is right side up, and snap back
into place. Turn damper handle (8) to the open position “WINTER” for the
heating season, or closed position
“SUMMER” for the cooling season.
7. Install the Aprilaire Humidifier Control in the return duct using the
installation instructions enclosed
(see Wiring Diagram, opposite side). For detailed installation and wiring
instructions, see “Humidifier Control Safety and Installation Instructions”
included with the humidifier
8. The Automatic Humidifier Control must be powered by a 24 VAC power source
connected to the “R” and “C” terminals on the Control. The 24 VAC humidifier
solenoid valve receives power through the Control. Connect the yellow wires to
the “H” terminals on the Control. Do not connect yellow wires to “ACC” or
“HUM” terminals on furnace or damage to the humidifier could result.
In order for the humidifier to turn on, the furnace blower must be operating
and the control must be calling for humidity. The interface between the Model
600 humidifier and the furnace to detect blower operation can be accomplished
several different ways:
A. If the Control is powered directly from 24 VAC “ACC” or “HUM” terminals on
the furnace, which are activated only during furnace blower operation or a
heat call, then the yellow wires from the humidifier can be connected directly
to the “H” terminals on the Control.
B. If the Control is powered by a transformer connected to 120 VAC “ACC” or
“HUM” terminals on the furnace, which are activated only during furnace blower
operation or a heat call, then the yellow wires from the humidifier can be
connected directly to the “H” terminals on the Control.
C. If the Control is powered from a continuous 24 VAC source, then a Model 50
Current Sensing Relay (not included) must be installed in the humidifier
circuit. (Yellow wires connected to “H” terminals on Control.)
Do not wire transformer into furnace blower circuit. The transformer can be
powered from the 120 VAC line before it enters the furnace.
9. Tap into a water supply line with the saddle valve furnished. See
instructions on saddle valve package. The humidifier will function with cold,
hot, softened or unsoftened water. The use of service hot water (140°F MAX.)
and constant blower operation will provide maximum evaporative capacity. When
installing humidifier on heat pump system, humidifier must be supplied with
service hot water
NOTE: The saddle valve is designed to be fully opened or closed. Do not use it to regulate water flow
10. Connect tubing from the saddle valve to the inlet side of the solenoid
valve using 1⁄4” (not furnished). TO PREVENT LEAKING!
(See Figure 3)
11. Drain spud is designed to accept 1⁄2” I.D. plastic hose (not furnished).
Run drain line from drain spud to floor drain. clamp is used, do not over
tighten, drain spud could crack. drain line has continuous slope. NOTE: Do not
sweat or directly attach metal drain line to fitting. Do not use solvent type
adhesive when connecting plastic drain line, since damage to fitting could
result.
12. Open saddle valve completely and turn on furnace. T humidifier control so
that humidifier will turn on. Allow humidifier to run until water is observed
coming out of the drain line. C humidifier and saddle valve are watertight.
Check operation to make sure that all electrical components function properly
by utilizing humidification system check-out section in the “Humidifier Safety
and Installation Instructions Set humidifier control to recommended level.
NOTE: THE JOB 1. Saddle 2. All plumbing are watertight.
3. Humidifier properly.
4. Bypass proper
PARTS LIST
IMPORTANT! Be sure owner’s manual containing instructions for operation and warranty information is given to owner in order to avoid unnecessary calls. Warranty is void unless humidifier is installed by qualified heating and air conditioning contractor due to possible misapplication of product.