KPERFORMANCE bE O2 Tiny EGT Controller CAN Bus User Manual
- July 6, 2024
- KPERFORMANCE bE
Table of Contents
KPERFORMANCE bE O2 Tiny EGT Controller CAN Bus User Manual
Package Contents
Tiny EGT should include the following Items:
- 1x circuit board with soldered surface mount components
- 1x MicroMolex connector
- 12x MicroMolex receptacles
- 1x 3D printed case
Electrical connections
C1 | Function |
---|---|
1 | CANH |
2 | Tc2 |
3 | Tc4 |
4 | Tc6 |
5 | 5V |
6 | GND |
7 | CANL |
8 | Tc1 |
9 | Tc3 |
10 | Tc5 |
11 | 12v |
12 | GND |
Molex-Notch facing Tc connections
Operational led Status
LED | Status | Function |
---|---|---|
1 | Power | Controller Started |
Off | Unit No Power | |
2 | Blinking/On | Canbus Activity/Connection OK **** CAN-connection |
or settings NOK
Off
CAN-bus Setup
Custom CAN-ID addressing(Optional)
Use full for users who already have multiple CAN-devices connected; resulting in duplicate ID conflicts.
Default ID = 5
Select custom ID via solder bridges S1&S2 on the bottm
CAN-ID | S1 | S2 |
---|---|---|
8 | open | closed |
7 | closed | closed |
6 | closed | open |
5(default) | open | open |
The Tiny EGT CanBus data:
Item | Function | Detail |
---|---|---|
CAN Speed | 500 Kbit | Default Speed |
CAN ID | 5 /6/7/8 | CAN-Bus ID |
Tunerstudio Setup
EGT OR (Spare ADC) CAN-Inputs:
CAN ADC 17-20 are used for EGT 1-4:
Your selected CanBus ID, Table 7 with offset 34
CAN ADC 21-22 are used for EGT 5-6:
CAN ADC 23-24 are used for monitoring PowerInput and version.
Your selected CanBus ID, Table 7 with offset 42
6x CAN EGT Inputs:
Unused EGT Inputs as spare CAN Analog Inputs:
WARNING
Do NOT connect more than 5V on input pins
CAN ADC 23-24 can NOT be re-used
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>