Schluter System BTERWL Room Sensor WL
About these operating instructions
These operating instructions describe the room sensor WL (also referred to as “product” in these operating instructions). These operating instructions are part of the product.
- You may only use the product if you have fully read and understood these operating instructions.
- Verify that these operating instructions are always accessible for any type of work performed on or with the product.
- Pass these operating instructions as well as all other product-related documents on to all owners of the product.
- If you feel that these operating instructions contain errors, inconsistencies, ambiguities or other issues, contact the manufacturer prior to using the product.
These operating instructions are protected by copyright and may only be used as provided for by the corresponding copyright legislation. We reserve the right to modifications. The manufacturer shall not be liable in any form whatsoever for direct or consequential damage resulting from failure to observe these operating instructions or from failure to comply with directives, regulations and standards and any other statutory requirements applicable at the installation site of the product.
Safety messages and hazard categories
These operating instructions contain safety messages to alert you to potential hazards and risks. In addition to the instructions provided in these operating instructions, you must comply with all directives, standards and safety regulations applicable at the installation site of the product. Verify that you are familiar with all directives, standards and safety regulations and ensure compliance with them prior to using the product. Safety messages in these operating instructions are highlighted with warning symbols and warning words. Depending on the severity of a hazard, the safety messages are classified according to different hazard categories.
NOTICE indicates a hazardous situation which, if not avoided, can result in equipment damage.
Intended use
This product may only be used to control the temperature in single rooms with
an underfloor heating system (heating/cooling).
Any use other than the application explicitly permitted in these operating
instructions is not permitted and causes hazards.
Verify that the product is suitable for the application planned by you prior
to using the product. In doing so, take into account at least the following:
- All directives, standards and safety regulations applicable at the installation site of the product.
- All conditions and data specified for the product.
- The conditions of the planned application.
In addition, perform a risk assessment in view of the planned application, according to an approved risk assessment method, and implement the appropriate safety measures, based on the results of the risk assessment. Take into account the consequences of installing or integrating the product into a system or a plant.
When using the product, perform all work and all other activities in conjunction with the product in compliance with the conditions specified in the oper-ating instructions and on the nameplate, as well as with all directives, standards and safety regulations applicable at the installation site of the product.
Predictable incorrect application
The product must never be used in the following cases and for the following
purposes:
- Explosive environments – In case of operation in explosive environments, sparks may lead to deflagration, fire or explosions.
- In conjunction with devices which are used for health-saving or life-saving purposes or whose operation may incur hazards to humans, animals or property.
Qualification of Personnel
Only persons who are familiar with and understand the contents of these
operating instructions and all other pertinent product documentation are
authorized to work on and with this product. Qualified personnel must be able
to predict and recognise potential hazards, based on their technical training,
knowledge and experience, that may arise from the use of the product.
Qualified personnel must be familiar with all regulations, standards and
safety guidelines that have to be followed when working on and with the
product.
Personal protective equipment
Always wear the required personal protective equipment. When performing work
on and with the product, take into account that hazards may be present at the
installation site which do not directly result from the product itself.
Modifications to the product
Only perform work on and with the product which is explicitly described in
these operating instructions. Do not make any modifications to the product
which are not described in these operating instructions.
Transport and storage
The product may be damaged as a result of improper transport or storage.
IMPROPER HANDLING
- Verify compliance with the specified ambient conditions during transport or storage of the product.
- Use the original packaging when transporting the product.
- Store the product in a clean and dry environment.
- Verify that the product is protected against shocks and impact during transport and storage.
Product description
Overview
A. Solar cell
B. Rotary dial for adjusting the room temperature
Dimensions
Function
The single room temperature controller is used to control the temperature in
rooms with underfloor heating system (heating/cooling).
The product measures the actual temperature of the corresponding room. The
desired set temperature is selected via the rotary control of the
corresponding product. The product transmits EnOcean® radio telegrams to the
WL connection modules. Every product has a unique identifier. If multiple
products are in use, the receiver can distinguish between the individual
products.
The product features a solar cell for energy supply. If the product is to be
set up in dark environments, an optional battery may be used (see “Technical
data”).
Approvals, conformities, certifications
The product complies with:
- EMC Directive (2014/30/EU)
- Low Voltage Directive (2014/35/EU)
- RoHS Directive (2011/65/EU)
The declaration of conformity can be accessed (downloaded) at www.bekotec- therm.de
Technical specifications
Mounting
Preparing mounting
In case of using multiple products, create an installation diagram that shows
the individual installation locations prior to installation. Label the
individual products with a number or the name of the installation location as
shown in the diagram.
- Make sure all connected devices are accessible at the installation location.
- Make sure the installation location is not situated in shielded areas or niches.
- Make sure the solar-powered energy storage is charged.
- Normal daylight is sufficient to charge the energy storage.
- Direct sun exposure decreases the charging time.
Connect the product via EnOcean®.
Connect the product with the recommended EnOcean components before you install
it (see section “Connecting the product to the WL connection module”).
Mounting the product
Cold walls and draughts affect temperature measurement.
Mount the product to inner walls and at an adequate distance from doors and
windows.
Stick the product to uneven walls using the adhesive dots supplied.
Screw or glue the product to even walls.
Sticking the product to a wall
Stick the product to the wall using the adhesive dots.
Removing the rotary dial and the upper part of the housing
- Turn the cam screw on the underside of the product by about 90 degrees with a screwdriver.
- Lift up and remove the twist-lock plate.
- Remove the upper part of the housing.
Mounting by screwing
Screw the bottom part of the housing to the even wall.
In darker environments:
Insert a battery into the battery compartment (A) of the top housing.
See “Inserting a battery (optional)”.
Refitting the rotary dial and the upper part of the housing
Turn the cam screw at the bottom of the thermostat back to the initial
position using a screwdriver.
Fit the upper part of the housing and the rotary dial to the bottom part of
the housing. Verify correct position with reference to the axis of rotation
when inserting the rotary dial.
Inserting a battery (optional)
If daylight is below 200 Lux, use an optional battery (see “Technical data”,
not included in the scope of supply).
- Remove the twist-lock plate and the top housing (see “Installing the product”).
- Insert a battery into the battery compartment (A) of the top housing. The positive terminal (+) must be visible after inserting the battery.
- Place the top housing and the twist-lock plate on the bottom housing.
Commissioning
Plug the product into the connection module WL
The installation instructions for the “Connection module WL” describe the
programming process.
Make sure the wireless signal of the room sensor reaches the connection module
WL and that the room sensor is located close to the connection module.
- Use the tip of a paper clip to push the LRN button of the product for at least 0.5 seconds.
Function test
Verify that the room temperature is between 15 °C and 25 °C.
-
Set the product to be tested for frost protection.
-
Set the product to be tested to 30°C.
After no more than one minute, the yellow LED lights up at the connection module WL to which the product is connected. -
Verify that the product to be tested is connected to the correct control circuit.
-
Repeat this procedure for all other products.
Operation
Adjusting the room temperature
Adjust the desired temperature at the thermostat.
-
Without temperature reduction:
The room temperature is set to the adjusted value -
With temperature reduction:
The room temperature is set to a value 4 K below the adjusted value
Limiting temperature adjustments
The adjustment range of the rotary dial is factory-set to a minimum of 8 °C
and a maximum of 30 °C by means of restrictors.
You can change the minimum and maximum temperature setting by adjusting the
limiter.
- Turn the cam screw on the underside of the product by about 90 degrees with a screwdriver.
- Lift up and remove the twist-lock plate.
Setting the minimum temperature
- Lift the blue restrictor at the flag (A).
- Turn the blue restrictor with the restrictor adjustment edge (B) to the desired value for the minimum temperature and refit it.
Setting the maximum temperature
- Lift the red restrictor at the flag (A).
- Turn the red restrictor with the restrictor adjustment edge (B) to the desired value for the maximum temperature and refit it.
- Turn the cam screw at the bottom of the thermostat back to the initial position so that you can refit the rotary dial.
- Place the twist-lock plate on the top housing.
Frost protection function
-
Without temperature reduction:
The room temperature is adjusted to 8 °C. -
With temperature reduction:
The room temperature is adjusted to 4 °C.
Maintenance
Time Activity
If necessary replace the optional battery
Troubleshooting
System impairments may only be addressed by the manufacturer.
Decommissioning, Disposal
Dispose of the product in compliance with all applicable directives, standards
and safety regulations.
Electronic components and batteries may not be disposed of in household waste.
- Dismount the product (see chapter “Mounting”, reverse sequence of steps).
- Remove the battery (see section “Inserting a battery (optional)” in reverse order).
- Dispose of the product and the optional battery separately.
Warranty
See our terms and conditions or your purchase contract for information on
warranty.
Spare parts and accessories
Product designation Room sensor WL
Part no. BTERWL/BW
Figure
Learn more online
Would you like to know more about Schlüter-Systems?
The quickest way is to visit our website.
You can also follow us on Instagram, Facebook and YouTube.
Schlüter-Systems KG · Schmölestraße 7 · D-58640 Iserlohn
Tel.: +49 2371 971-1261 · Fax: +49 2371 971-1112 ·
info@schlueter.de · schlueter-systems.com
Schlüter-Systems Ltd · Units 3-6 Bardon 22 Industrial Estate · Bardon
Hill · Coalville · Leicestershire · LE67 1TE
Tel.: +44 1530 813396 · Fax: +44 1530 813376 ·
sales@schluter.co.uk ·
schluter.co.uk
References
- Schlüter-Systems international: Choose your language | Schlüter-Systems
- Schlüter-Systems Ltd – Profile of innovation | Schlüter-Systems
- Fußbodenheizungen von Schlüter-Systems: Wohlfühl-Klima mit System | Schlüter-Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>