LSIL633T-E Electric Range Installation Guide

July 3, 2024
LSIL

LSIL633T-E Electric Range

LSIL633T-LOGO

Specifications

  • Model: LSIL633TE, LSIL6332E
  • Width: 29 7/8″ (758.8 mm)
  • Height: 36 1/2″ (927.9 mm)
  • Depth (Including Door Handle): 29 5/16″ (743.9 mm)
  • Depth (Product Body Only): 24 3/4″ (629.4 mm)
  • Depth (Excluding Door Handle): 26 7/8″ (683.0 mm)
  • Depth (Drawer Fully Opened): 36 1/16″ (916.2 mm)
  • Depth (Door Fully Opened): 48 5/8″ (1235.9 mm)

Installation Instructions

Before Installing
Before installing the product, follow these steps:

Installation Overview
Please read the following installation instructions first after purchasing this product or transporting it to another location. The images in this guide may be different from the actual components and accessories, which are subject to change by the manufacturer without prior notice for product improvement purposes.

LSIL633T-E-Electric-Range-fig- \(1\)

  1. Check and choose the proper location
  2. Install anti-tip device
  3. Level the range
  4. Engage the anti-tip device
  5. Connect electric range
  6. Test run
  7. Plug in the power cord

Tools Needed
You will need the following tools for installation:

LSIL633T-E-Electric-Range-fig- \(1\)

  1. Phillips Screwdriver
  2. Flat-blade Screwdriver
  3. 1/4 Nut Driver
  4. Pliers
  5. Tape Measure
  6. Level
  7. Adjustable Wrench
  8. Drill
  9. Safety Glasses
  10. Gloves

Leveling the Range
To level the range, adjust the leveling legs using a wrench. Extending the legs slightly may facilitate inserting the rear leg into the anti-tip bracket.

Parts

Parts Provided

LSIL633T-E-Electric-Range-fig- \(3\)

  1. Template (1 ea)
  2. Anti-tip Bracket Kit (1 ea)
  3. Anchor Sleeves (6 ea)
  4. Lag Bolts (6 ea)

NOTE

  • Observe all governing codes and ordinances.
  • Have the installer show you the location of the circuit breaker or fuse. Mark it for easy reference.
  • As when using any appliance generating heat, there are certain safety precautions you should follow.
  • Be sure your range is installed and grounded properly by a qualified installer or service technician.

Unpacking and Moving the Range

WARNING

  • You should use two or more people to move and install the range. (Excessive Weight Hazard) Failure to do so can result in back or other injury.
  • Do not use the door handles to push or pull the range during installation or when moving the range out for cleaning or service. Doing so can result in serious damage to the range.LSIL633T-E-Electric-Range-fig- \(4\)
  • Do not push or pull the range by grabbing the open oven door or cooktop only. Doing so can result in serious damage to the range.
  • Do not lift the range using the cooktop or door handle. Doing so can cause damage and improper operation of the range.
  • To reduce the risk of burns, do not move this appliance while it is hot.

NOTE

  • The image may differ from the actual model.
  • Your range is heavy and can be installed on soft floor coverings such as cushioned vinyl or carpeting. Use care when moving the range on this type of flooring. Use a belt when moving the range to prevent damaging the floor. Or slide the range onto cardboard or plywood to avoid damaging the floor covering.
  • Remove packing material, tape and any temporary labels from your range before using. Do not remove any warning-type labels, the model and serial number label, or the Tech Sheet that is located on the back of the range.
  • To remove any remaining tape or glue, rub the area briskly with your thumb. Tape or glue residue can also be easily removed by rubbing a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.
  • Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your range.

Choosing the Proper Location

Dimensions and Clearances

LSIL633T-E-Electric-Range-fig- \(8\)

| Dimensions| *LSIL633TE**

*LSIL6332E**

---|---|---
A| Width| 29 7/8″ (758.8 mm)
B| Height| 36 1/2″ (927.9 mm)
C| Depth (Includes Door Handle)| 29 5/16″ (743.9 mm)
D| Height (Excludes Vent Trim)| 36″ (913.0 mm)
E| Depth (Includes only the product body that is loaded into the cabinet. Excludes door, drawer, and handles)| 24 3/4″ (629.4 mm)
F| Depth (Excludes Door Handle)| 26 7/8″ (683.0 mm)
G| Depth when drawer is fully opened| 36 1/16″ (916.2 mm)
H| Depth when door is fully opened| 48 5/8″ (1235.9 mm)

Minimum Dimensions

LSIL633T-E-Electric-Range-fig- \(9\)

  1. Minimum distance from the top of the range to combustible surface overhead: 30″ (76.2 cm)
  2. Minimum distance from countertop to overhead cabinets at side: 15″ (38.1 cm)
  3. Minimum opening in overhead cabinets: 30″ (76.2 cm)
  4. Height of countertop: 36″ (91.3 cm)

NOTE

  1. 30″ (76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24″ (60.9 cm) minimum when the bottom of a wood or metal cabinet is protected by not less than 1/4″ (0.64 cm) flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015″ (0.381 mm) stainless steel, 0.024″ (0.610 mm) aluminium or 0.020″ (0.508 mm) copper.
  2. 15″ (38.1 cm) minimum between the countertop and adjacent cabinet bottom.
  • Important – Save for the use of the local electrical inspector.
  • For installation in Canada, a free-standing range is not to be installed closer than 15/32″ (12 mm) from any adjacent surface.

Clearances

LSIL633T-E-Electric-Range-fig- \(9\)

  1. Acceptable Electrical Outlet Area
  2. Normal Countertop Depth
  3. Counter Top Height
  4. Cabinet
  5. Wall
  6. Center
  7. Cabinet Opening
    • = 30″ (76.2 cm) For U.S.A
    • = 30″ (76.2 cm) ~ 31″ (78.7 cm) For CANADA

Electricity
The range should always be plugged into its own individual properly grounded electrical outlet.

  • This prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
  • It is recommended that a separate circuit serving only this appliance be provided.

Flooring

  • CAUTION
    • Use an insulated pad or 1/4 in. (0.64 cm) plywood under the range if installing the range over carpeting.

Ambient Temperature

  • CAUTION
    • Make sure wall coverings, countertops and cabinets around the range can withstand the heat (up to 194 °F) generated by the range. Discoloration, delamination or melting may occur. This range has been designed to comply with the maximum allowable wood cabinet temperature of 194 °F
    • Before installing the range in an area covered with linoleum or other synthetic floor covering, make sure the floor covering can withstand temperatures of at least 200 °F (93 °C).

Levelling

  • Levelling the Range
    Level the range by adjusting the levelling legs with a wrench. Extending the legs slightly may also make it easier to insert the rear leg into the anti-tip bracket.LSIL633T-E-Electric-Range-fig- \(11\)

Checking Adjustments

  1. Place the level diagonally on the oven rack, and check each direction for level.
    • First check direction a. Then check direction b.
  2. If the level doesn’t show that the rack is level, adjust the leveling legs with a wrench.

Connecting Electricity

  • Electrical Requirements
    This appliance must be installed and grounded on a branch circuit by a qualified technician in accordance with the National Electrical code ANSI/ NFPA NO. 70 – latest edition. All wiring should conform to local and NEC codes. This range requires a single-phase, 3 wire, AC 120/ 208 V or 120/240 V 60 Hz electrical system. Use only a 3-conductor or a 4-conductor UL – listed range cord with closed-loop terminals, open-end spade lugs with upturned ends or similar termination. Do not install the power cord without a strain relief. A range cord rated at 40 amps with 120/240 Vminimum range is required. If a 50 amp range cord is used, it should be marked for use with 1 3/ 8″ diameter connection openings. This appliance may be connected by means of a conduit or power cord. If a conduit is being used, refer to “3-Wire Connection: Conduit” or “4-Wire Connection: Conduit” sections.

WARNING

  1. Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary.
  2. The power supply cord and plug should not be modified. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
  3. Using an extension cord to connect the power is prohibited. Connect the power cord and plug directly.
  4. Electrical ground is required on this appliance.
  5. Make sure that the power cord is not pinched by the range or heavy objects. Failure to do so can result in serious burns or electrical shock.

Specified Power Cord Kit Rating

  • Case 1
    • Voltage: 120/240 volts (3-wire)
    • Range rating: 8,750 W – 16,500 W
    • Specified rating of power supply-cord kit, amperes: 40 A or 50 A
    • Diameter (inches) of range connection opening
    1. Power cord: 1 3/8″
    2. Conduit: 1 1/8″
  • Case 2
    • Voltage: 120/240 volts (3-wire)
    • Range rating: 16,501 W – 22,500 W
    • Specified rating of power supply-cord kit, amperes: 50 A
    • Diameter (inches) of range connection opening
    • Power cord: 1 3/4″
    • Conduit: 1 3/8″
  • Case 3
    • Voltage: 120/208 volts (3-wire)
    • Range rating: 7,801 W- 12,500 W
    • Specified rating of power supply-cord kit,amperes: 40 A or 50 A
    • Diameter (inches) of range connection opening
    • Power cord: 1 3/8″
    • Conduit: 1 1/8″
  • Case 4
    • Voltage: 120/208 volts (3-wire)
    • Range rating: 12,501 W – 18,500 W
    • Specified rating of power supply-cord kit, amperes: 50 A
    • Diameter (inches) of range connection opening
    • Power cord: 1 3/4″
    • Conduit: 1 3/8″

Wire Electrical Wall Receptacle

4 Wire receptacle (14-50R)

3 Wire receptacle (10-50R)

Connecting the Power Cord / Conduit
The rear access cover must be removed. Loosen the two screws with a screwdriver. The terminal block will then be accessible.

Use the cord/conduit connection plate b to install the power cord or conduit. Leave the connection plate as installed for power cord installations. Remove the connection plate for conduit installations and rotate it to use the smaller 1 1/8 in. (2.8 cm) conduit hole c instead of the 1 3/8 in. (3.5 cm) power cord hole d.

LSIL633T-E-Electric-Range-fig- \(15\)

For power cord e installations, hook the strain relief over the 1 3/8 in. (3.5 cm) power cord hole located below the rear of the oven. Insert the power cord through the strain relief and tighten it.

LSIL633T-E-Electric-Range-fig- \(16\)

For conduit installations, insert the conduit strain relief in the 1 1/8 in. (2.8 cm) conduit hole. Then install the conduit through the body of the strain relief and fasten the strain relief with its ring.

LSIL633T-E-Electric-Range-fig- \(17\)

  • Ring
  • Body
  • Cord/Conduit Connection Plate
  • Conduit

3-Wire Connection: Power Cord

  • WARNING
    • The white middle (neutral or ground) wire of a 3- wire power cord or a 3-wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. Failure to do so can result in electrical shock, severe personal injury or death.
    • If screws are not tightened securely, it can result in electrical spark and severe personal injury or death.
  1. For power cord installations, hook the strain relief over the power cord hole (1 3/8″) located below the rear of the oven.

  2. Insert the power cord through the strain relief and tighten it.
    CAUTION

    • Do not install the power cord without a strain relief.
  3. Remove the lower 3 screws from the terminal block and retain them.

  4. Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block.

    • Make sure that the white center wire is connected to the center lower position of the terminal block.
  5. Tighten the 3 screws securely into the terminal block.

CAUTION
Do not remove the ground strap connections.

LSIL633T-E-Electric-Range-fig- \(17\)

  • Black
  • White
  • Red
  • Terminal Block
  • Cord/Conduit Connection Plate

4-Wire Connection: Power Cord

WARNING

  • Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed-loop connectors or opened spade lugs with upturned ends must be used. The white middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block. The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection. The 4th ground wire (green) must be connected to the frame of the range with the ground screw. Failure to do so can result in electrical shock, severe personal injury or death.
  • If screws are not tightened securely, it can result in an electrical spark and severe personal injury or death.
  1. For power cord installations, hook the strain relief over the power cord hole (1 3/8″) located below the rear of the oven.

  2. Insert the power cord through the strain relief and tighten it.
    CAUTION

    • Do not install the power cord without a strain relief.
  3. Remove the lower 3 screws from the terminal block and retain them.

  4. Remove the ground screw and bend the end of the ground strap up so the slot is over the hole of the center screw removed in step 3.

  5. Insert the ground screw into the power cord ground wire (green) terminal ring and secure it to the range frame.

  6. Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block.

    •  Make sure that the white center (neutral) wire is connected to the center lower position of the terminal block.
  7. Tighten the 3 screws securely into the terminal block.

    • The center screw now attaches the bent up ground strap to the block.

LSIL633T-E-Electric-Range-fig- \(19\)

  1. Black
  2. White
  3. Red
  4. Terminal Block
  5. Ground Strap
  6. Ground Screw
  7. Cord/Conduit Connection Plate
  8. Bend strap up and attach.

3-Wire Connection: Conduit
WARNING

  1. If screws are not tightened securely, it can result in electrical spark and severe personal injury or death.

Conduit Installations
CAUTION

  • Do not install the conduit without a strain relief.
  1. Remove the cord/conduit connection plate
    from the rear of the oven and rotate it.

  2. The conduit hole (1 1/8″) must be used.

  3. Prepare the conduit wires as shown below.

  4. Cord/Conduit connection plate

  5. Install the conduit strain relief.

  6. Insert the strain relief in the 1 1/8 in. (2.8 cm) conduit hole.

  7. Install the conduit through the body of the strain relief and fasten the strain relief with its ring.
    NOTE

  8. For conduit installations, purchase a strain relief.

  9. Reinstall the cord/conduit connection plate.

Conduit Connections
If the wire in the conduit is copper it must be 8 or 10 AWG wiring. If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring.

  1. Loosen the lower 3 screws from the terminal block.
  2. Insert the bare wire (white/neutral) end through the center terminal block opening. Do not remove the ground strap connections.
  3. Insert the two side bare wire ends into the lower left and the lower right terminal block openings.
  4. Tighten the 3 screws securely into the terminal block. (approximately 35 – 50 IN-LB)

LSIL633T-E-Electric-Range-fig- \(21\)

  1. Black
  2. White
  3. Red
  4. Terminal Block
  5. Wire Ends
  6. Conduit Connection Plate

4-Wire Connection: Conduit

WARNING

  1. The white middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block. The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. The 4th ground wire (green) must be connected to the frame of the range with the ground screw. Failure to do so can result in electrical shock, severe personal injury or death.

WARNING

  1. If screws are not tightened securely, it can result in electrical spark and severe personal injury or death.

Conduit Installations
CAUTION

  • Do not install the conduit without strain relief.
  1. Remove the cord/conduit connection plate from the rear of the oven and rotate it.

  2. The conduit hole (1 1/8″) must be used.

  3. Prepare the conduit wires as shown below.

  4. Cord/Conduit Connection Plate

  5. Ground Wire

  6. Install the conduit strain relief.

  7. Insert the strain relief in the 1 1/8 in. (2.8 cm) conduit hole.

  8. Install the conduit through the body of the strain relief and fasten the strain relief with its ring.
    NOTE

  9. For conduit installations, purchase a strain relief.

  10. Reinstall the cord/conduit connection plate.

Conduit Connections
If the wire in the conduit is copper it must be 8 or 10 AWG wiring. If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring.

  1. Loosen the 2 lower left and right screws from the terminal block. Remove the lower 2 center screws. Do not discard any screws.
  2. Remove the ground screw and bend the end of the ground strap up so the slot is over the hole of the center screw removed in step 1.
  3. Attach the ground (green) bare wire end to the range frame and secure it in place with the ground screw.
  4. Insert the bare wire (white/neutral) end through the center terminal block opening. The center screw now attaches the bent up ground strap to the block.
  5. Insert the two side bare wire ends into the left and the right terminal block openings. Tighten the 3 screws securely into the terminal block. (approximately 35 – 50 IN-LB)

LSIL633T-E-Electric-Range-fig- \(23\)

  1. Black
  2. White
  3. Red
  4. Terminal Block
  5. Wire Ends
  6. Ground Strap
  7. Conduit Connection Plate
  8. Ground Screw
  9. Ground Wire
  10. Bend strap up and attach.

Optional Rear Filler

Installing the Rear Filler
If the counter does not bridge the opening at the rear wall, the rear filler kit that is provided with the slide in range will be needed.

NOTE

  • If the countertop depth is greater than 25 3/8″ there will be a gap between the filler kit and the back wall.
  • If the countertop depth is less than 24 3/4″, the control panel will not sit flush with the countertop.

LSIL633T-E-Electric-Range-fig- \(24\)

  • Using a screwdriver, remove the three screws holding the rear top plate in place.
    1. Rear Top Plate
  • Attach the rear top plate and filler assembly as shown, using three screws removed in step 1.LSIL633T-E-Electric-Range-fig- \(25\)
    1. Rear filler

Anti-tip Device

Installing the Anti-tip Device Tip Hazard

WARNING

  • A child or adult can tip the range and be killed.
  • Install the anti-tip device to the structure and/or the range. Verify the anti-tip device has been properly installed and engaged by following the guide on the anti-tip bracket template.
  • Engage the range to the anti-tip device by following the guide on the anti-tip bracket template. Ensure the anti-tip device is reengaged when the range is moved by following the guide on the anti-tip bracket template.
  • Re-engage the anti-tip device if the range is moved. Do not operate the range without the anti-tip device in place and engaged.
  • See installation instructions for details.
  • Failure to follow these instructions can result in death or serious burns to children or adults.
  • Range must be secured with an approved antitip device.
  • The range could be tipped by standing, sitting or leaning on an open door if the range or anti-tip device is not properly installed.
  • The use of this device does not preclude tipping of the range when not properly installed.
  • After installing the anti-tip device, verify that it is in place by carefully attempting to tilt the range forward.
  • This range has been designed to meet all recognized industry tip standards for all normal conditions.
  • The installation of the anti-tip device must meet all local codes for securing the appliance.

Using the Anti-tip Bracket Template

  • The anti-tip bracket is packaged with an installation template. The instructions include necessary information to complete the installation. Read and follow the range installation instruction sheet.
  • Screws c must enter wood or concrete.LSIL633T-E-Electric-Range-fig- \(27\)
    1. Anti-tip Bracket
    2. Wall Plate

Engaging the Anti-tip Device

  • Anti-tip Bracket
  • Leveling Leg
  1. Slide the range against the wall, making sure the back leg slides into and engages the antitip bracket.
  2. Check for proper installation by grasping the front edge of the cooktop and carefully attempting to tilt the range forward.

Test Run

Test the Range Before Use
Check if the range is properly installed and run a test cycle.

  1. Before using the cooktop for the first time, clean it with a ceramic cooktop cleaner. This helps protect the top and makes cleanup easier.
  2. Fill an induction-capable pot with water and place it on a surface element. Turn on the surface element. The water should heat. Repeat for all surface elements.
  3. After checking all the surface heating elements, check the locking system by pressing Control Lock for three seconds. The oven controller should lock and the cooktop should not operate while the Control Lock function is turned on. Press Control Lock for three seconds to disable Control Lock.
  4. Now check the oven’s operation. Press Bake. 350 °F appears in the display. Press START.
  5. The oven should finish preheating in 15 minutes, and the convection fan should operate while the oven is preheating.
  6. After checking the oven’s operation, turn thetemperature up to 450 °F and leave the oven on for at least an hour to help remove any oil which might cause smoke and odors when first using the oven.

NOTE

  1. Smoke may come out of the range when it is first used.

Frequently Asked Questions (FAQ)

Q: What should I do if I encounter issues during installation?
A: If you face any problems during installation, refer to the troubleshooting section of the user manual or contact our customer support for assistance.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals