Haier HPR10XC6 Air Conditioner Owner’s Manual

July 2, 2024
Haier

Haier-LOGO

Haier HPR10XC6 Air Conditioner

Specifications

  • Model: HPR10XC6
  • Manufacturer: Haier America
  • Voltage: 115V
  • Frequency: 60Hz
  • Version: 1.0

Product Usage Instructions

  • Before performing any maintenance or repair on the unit, ensure to unplug it to avoid electric shock.
  • Take precautions when touching cooling coils or performing welding/soldering.
  • Only qualified professionals should conduct welding on the unit.
  • Strictly adhere to the manual specifications when replacing components.
  • Use factory-approved electrical components and ensure proper wiring.
  • Follow the outlined steps in the flow chart to troubleshoot and repair common issues like the air conditioner not starting or not cooling properly.
  • Refer to the troubleshooting guide for issues like the unit not running, not cooling properly, or water full indicator lights.
  • Follow the suggested actions to resolve these problems.

Operation

  • Operate the unit by adjusting fan speed, setting time on/off, selecting cooling/dry/fan modes, and monitoring the display for warnings or indicators.

FAQ

  • Q: How do I troubleshoot if the air conditioner won’t start?
  • A: Check for power issues, loose plug/socket, timer failure, or power switch problems. Follow the flow chart for detailed troubleshooting steps.
  • Q: What should I do if the air conditioner doesn’t cool properly?
  • A: Troubleshoot compressor failure, protector failure, capacitor failure, refrigerant leakage, or loose wiring. Follow the specific steps mentioned in the manual.
  • Q: How can I resolve issues with water full indicator lights?
  • A: Drain water using the drainage pipe on the rear panel. If the problem persists, seek assistance from a qualified technician.

This manual is for the use of technical personnel entrusted with maintenance.
Widetech reserves the right to change this dehumidifier’s casing, circuit, and parts without notice.

IMPORTANT POINTS ON SERVICE OPERATING SAFETY

Please follow these instructions carefully

  • Unplug the unit to avoid any danger from electric shock before disassembling the unit for repair.
  • If there is any sound of the refrigerant circulating when in operation, avoid touching the cooling coils.
  • If you need to perform any welding or soldering, be sure you are in a well-ventilated area.
  • Only a qualified professional should perform any welding on the unit.
  • When repairing the unit, the specifications listed in this manual must be strictly adhered to when replacing any components.
  • When replacing any electrical components they should be factory-approved units.
  • Be sure that any electrical components are properly wired and in place.

FLOW CHART FOR INSPECTING AND REPAIRING THE UNIT

Haier-HPR10XC6-Air-Conditioner-FIG-1

APPEARANCE(OUT WARD)

Haier-HPR10XC6-Air-Conditioner-FIG-3 Haier-
HPR10XC6-Air-Conditioner-FIG-4

TROUBLESHOOTING

Haier-HPR10XC6-Air-Conditioner-FIG-13 Haier-
HPR10XC6-Air-Conditioner-FIG-14

OPERATION

CONTROL PANEL

Haier-HPR10XC6-Air-Conditioner-FIG-5

Power Control

  • The power control turns the unit on and off.

Warning Light

  • Condensed water may accumulate in the unit. If the internal tank becomes full, the Warning Light will shine and the unit will not operate until the unit has been drained.

Mode Control

The Mode Control has 3 settings:

  • Cool
  • Dehumidify
  • Fan

The settings are adjusted with Mode Control button. A light will indicate which setting is currently being used.

Cooling Mode

  • During the cooling mode, the air is cooled and hot air is exhausted to the outside through the exhaust tube. Adjust fan speed and air temperature to suit your desired comfort level.

Note: The air exchange hoses must vent outside the room when using cool mode.

Dehumidify Mode

Air is dehumidified as it passes through the unit, without being in full cooling mode. If room temperature is 25 degrees Celsius, fan speed can be adjusted; otherwise, fan speed is fixed to ” Low

“. Note: The warm air exchange hoses must vent inside the room when using Dehumidify Mode, not outside as it does when cooling.
If the unit is vented outside some cooling will occur.

Fan Mode

Air is circulated throughout the room with no cooling.
Note: The unit does not need to be vented in Fan mode

Fan Speed Control

  • The Fan Speed Control has 3 settings: High, Medium, and Low.

Timer

Auto turn off

  • With the machine in running mode, press the timer button to select the number of hours you would like the unit to run in air conditioning mode until it automatically shuts off.

Auto turn on

  • With the machine in standby mode, press the timer button to select the number of hours until you would like the unit to automatically start running in air conditioning mode.

Timer / Temp set controls

  • Used for adjusting the timer and thermostat.
  • The default display is room temperature.
  • In cooling mode, when “ ” button is pressed, the set temperature is displayed and may be adjusted.
  • After 15 seconds the display will revert to room temperature. Temperature is only adjustable in cool mode. The time is adjustable between 1~12 hours.

Note: By pressing both set buttons at the same time, the display will toggle between Celsius and Fahrenheit.

  • Air Conditioner Remote Control (batteries not included)
  • The functions work the same as your air conditioner’s touch controls
  • All key functions can be accessed from the remote control.

CONTROL PANEL

Haier-HPR10XC6-Air-Conditioner-FIG-9

Notes

  • Do not drop the remote control.
  • Do not place the remote control in a location exposed to direct sunlight.
  • The remote control should be placed about 1 meter or more away from TV, or any electrical appliances.

Battery replacement

  • Remove the cover on the back of the remote control and insert the batteries with the ( + ) and ( – ) poles pointing in the proper direction.

Haier-HPR10XC6-Air-Conditioner-FIG-10

CAUTION

  • Use only AAA or IEC R03 1.5V batteries.
  • Remove the batteries if the remote control is not used for a month or longer.
  • Do not attempt to recharge the supplied batteries.
  • All batteries should be replaced at the same time, do not mix old batteries.
  • Do not dispose of the batteries in a fire as they may explode.

TECHNICAL SPECIFICATIONS

AIR CONDITIONER

ITEM UNIT HPR10XC6
OUTER DIMENSION mm 470W900H370D
REFERENTIAL USING AREA m2 16∼22
RATED VOLTAGE V/Hz 115 / 60
COOLING CAPACITY B.T.U. 10000
DEHUMIDIFYING CAPACITY L/H 1.6
RUNNING CURRENT A 9.0
POWER CONSUMPTION W 950
INDOOR AIR VOLUME M3/hr 380

COMPRESSOR

|

MODEL

|  | 2R12S3R126A
INPUT POWER| W| 740
OPERATING CYCLE| uF/V| 35/250
PROTECTOR|  | MRA98503 or MRA98706 or MRA98706-9090
LOCKED ROTORAMPS| A| 6.9

INDOOR MOTOR

| MODEL|  | LS-13T3-4P
OUTPUT POWER| W| 17
OPERATING CYCLE| uF/V| 4.0/250

OUTDOOR MOTOR

| MODEL|  | LS-40T1-4P
OUTPUT POWER| W| 33
OPERATING CYCLE| uF/V| 6.0/250

TURBINE FAN MOTOR

| MODEL|  | WT-15T1-01
OUTPUT POWER| W| 2
CAPILLARY| mm| 2.6(O.D.)1.6(I.D.)950(L)
EVAPORATOR|  | 3R14S17FPI
CONDENSER|  | 3R14S21FPI
REFRIGERANT| R-22/g| 460
WEIGHT| Kg| 34

REFRIGERATOR SYSTEM DIAGRAM

Haier-HPR10XC6-Air-Conditioner-FIG-11

SCHEMATIC WIRING DIAGRAM

Haier-HPR10XC6-Air-Conditioner-FIG-12