BLUSTREAM SW12USB USB 3.2 Gen 2 Switch
Thank You For Purchasing This Product.
For optimum performance and safety, please read these instructions carefully before connecting, operating or adjusting this product. Please keep this manual for future reference.
Surge Protection Device Recommended
This product contains sensitive electrical components that may be damaged by electrical spikes, surges, electric shock, lightning strikes, etc. Use of surge protection systems is highly recommended in order to protect and extend the life of your equipment.
Safety And Performance Notice
Do not substitute or use any other power supply other than the enclosed unit, or a Blustream approved replacement.
Do not disassemble the unit for any reason. Doing so will void the manufacturer’s warranty.
Introduction
The SW12USB is a USB 3.2 Gen2 10Gb switcher, supporting 4 x USB devices that can be switched to 2 x USB-C host connections. The SW12USB supports auto switching between host devices using signal sense, or manually controlled via the front-panel push buttons, Web-GUI, TCP/IP, or RS-232
FEATURES:
- USB 3.2 Gen2 switch allowing up to 4 x USB peripheral devices to connect to 2 x USB hosts
- Features 2 x USB-C and 2 x USB-A device inputs and 2 x USB-C hosts
- USB 3.2 Gen2 connectivity with data transfer rate up to 10Gbps
- Backwards compatible with USB 2.0 and 1.1
- Auto or manual switching
- Plug-and-play with no drivers, downloads, or software required
- Features 1 x GPI port for integration with 3rd party products
- Features 802.3at PoE+ for powering of product from PoE+ network
- Local 24v power supply input for when network switch does not support PoE+
- Web interface module for control and configuration of SW12USB
- Control via front panel buttons, RS-232, or TCP/IP
Front Panel
- Power LED indicator – Illuminates when the unit is powered
- USB Host LED Indicator – Illuminates when the corresponding USB Host is selected
- Auto Switching LED Indicator – Illuminates when auto switching mode is enabled
- USB Host Input – USB-C to connect to USB Host device
- Select Button – Press to toggle between USB Hosts. Press and hold for 3 seconds to enable / disable auto switching function
- Reset Switch – Press to factory reset the unit
- Upgrade Selection Switch – Select between Hub or MCU for firmware upgrade function
- Upgrade Port – Micro USB for firmware upgrade function
Rear Panel
-
USB-C Device Inputs – Connect to USB-C devices
-
USB-A Device Inputs – Connect to USB-A devices
NOTE: Total USB Device (USB-C + USB-A) charging support = 5V 4A. Max output per port is 5V 1.7A. -
GPI Port – General purpose input for triggering input change – see follow page for details
-
RS-232 Port – 3-pin Phoenix connector for control of the switcher from a PC or control processor
-
External IR Port – Connect Blustream 5V IR receiver, or control processor to control the switcher
-
Power Port – Use supplied Blustream 24V/1.25A DC adaptor to power the unit
USB Performance
The SW12USB is a USB 3.2 Gen2 USB switch with data transfer rate up to 10Gbps and backwards compatibility support for USB 2.0 and 1.1 devices. Please note that actual USB performance will be dependent on the following factors:
- USB Host version and cable length / quality
- USB Device version and cable length / quality
It is possible for the SW12USB to limit the USB-A Device port speed from 10Gbps to 5Gbps to improve device compatibility via the Web GUI and API.
General Purpose Input (GPI) Port
The General Purpose Input (GPI) Port can be used to trigger the Host input to change on the SW12USB. It has 3 modes of function and can be configured via the Web GUI.
Pulse Mode:
In Pulse Mode, when the GPI port receives a signal pulse (every high (1-12V) to low (Ground) voltage change), it triggers the SW12USB device to change Host inputs.
Level Mode:
In Level Mode, the SW12USB will trigger based on the voltage applied to the GPI port. The low level trigger and high level trigger can be specified between 0-12V.
The SW12USB will switch to Host 1 when GPI voltage is greater than the High Level trigger level. The SW12USB will switch to Host 2 when GPI voltage is less than the Low Level trigger level.
Contact Closure Mode:
In Contact Closure Mode when GPI port is open circuit, the SW12USB will select Host 1.
When GPI port is shorted to ground, the SW12USB will select Host 2.
Web-GUI Control
The SW12USB features an in-built web-GUI for control and configuration of the unit. By default the device is set to DHCP, however if a DHCP server (eg: network router) is not installed the device IP address will revert to below details:
Default Username: blustream Default Password: 1234 Default IP Address: 192.168.0.200
The device can also be accessed via its mDNS name which is defaulted to: http://SW12USB.local/
Telnet & RS-232 Control Port
The SW12USB can be controlled via a 3-pin Phoenix to serial RS-232 cable or via Telnet. The RS-232 communication settings and commands are as follows:
Baud Rate: 57600 bps Data Bit: 8-bit Parity: None Stop Bit: 1-bit Flow Control: None
RS-232 / TELNET COMMAND | DESCRIPTION |
---|---|
?/HELP | Print Help Information |
STATUS | Print System Status And Port Status |
PON/OFF | Set System Power On Or Of |
RESET | Reset System To Default Setting Type ‘Yes’ To Confirm, ‘No’ To Discard |
Within 30 Seconds
HOST yy FR All| Set Connect From Host: yy
yy = 01 : Host1
yy = 02 : Host2
SWITCH aa| Set Switching To aa
aa = AUTO: Auto Switching ON – Auto Mode
aa = MAN: Auto Switching OFF – Manual Mode
USBDP aa| Set USB Device Power Mode
aa = FH : Follow Host
aa = ON : Always On
USBDPOUT yy ON/OFF| Set USB Device Power Output yy = 00 : All Devices yy =
01-04 : Device1-4
GPI yy| Set GPI Mode
yy = 00 : Pulse Mode
yy = 01 : Level Mode
yy = 02 : Contact Closure Mode
GPI LOW xx| Set The Low Level Voltage In The Level Mode xx Range 0~12000 Unit
mV
GPI HIGH xx| Set The High Level Voltage In The Level Mode xx Range 0~12000
Unit mV
FP LOCK ON/OFF| Set Front Panel Lock ON Or OFF
NAME zz| Set Device Name zz Is New Device Name
UG HUB yy| Select Hub Upgrade
Note: All Connected Devices Will Lost. Switch The Host Or Reconnect The
USB Cable It Will Be Returned To Normal
yy = 01 : Hub1
yy = 02 : Hub2
SPEED yy| Set Type-A Port Speed
yy = 00 : Speed 5G
yy = 01 : Speed 10G
RS232BAUD z| Set RS232 Baud Rate To xx
z = 1 2400, 2 4800, 3 9600, 4 19200, 5 38400, 6 57600 (Default), 7 115200
RS232ON y:z:a| Send y Type Of Command a Stored In Local RS232 Whose Baud
Rate Is z
y = a ASCII, h HEX
z = 1 2400, 2 4800, 3 9600, 4 19200, 5 38400, 6 57600 (Default), 7 115200
a = RS232 Command
NET DHCP ON/OFF| Set Auto IP(DHCP) On Or Of
NET TN 8000 ON/OFF| Set Telnet Port 8000 On Or Of
NET TN ON/OFF| Set Telnet Port On Or Of
NET MDNS ON/OFF| Set mDNS On Or Of
NET IP xxx.xxx.xxx.xxx| Set IP Address
NET GW xxx.xxx.xxx.xxx| Set Gateway Address
NET SM xxx.xxx.xxx.xxx| Set Subnet Mask Address
NET RB| Set Network Reboot And Apply New Config!!!
NET TN xxxx| Set Telnet Port
Specifications
- USB Device: 2 x USB Type A female, 2 x USB Type C female
- USB Host: 2 x USB Type C female
- GPI / RS-232 Serial Port: 1 x 4-pin Phoenix connector
- TCP/IP Control: 1 x RJ45, female
- Firmware Upgrade: 1 x Micro-USB
- Dimensions (W x D x H): 150mm x 110mm x 23mm
- Shipping Weight: 0.6kg
- Operating Temperature: 32°F to 104°F (0°C to 40°C)
- Storage Temperature: -4°F to 140°F (-20°C to 60°C)
- Power Supply: 24V/1.25A DC, 4-pin DIN connector
NOTE: Specifications are subject to change without notice. Weights and dimensions are approximate.
Package Contents
- 1 x SW12USB
- 1 x 24V/1.25A DC power supply
- 1x Mounting kit
- 1 x Quick Reference Guide
Maintenance
Clean this unit with a soft, dry cloth. Never use alcohol, paint thinner or benzene to clean this unit.
Components inside this unit are not user serviceable. Do not remove the protective cover from the unit. Removing any panel from this product will invalidate the manufacturers warranty.
Certifications
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CAUTION – changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
CANADA, INDUSTRY CANADA (IC) NOTICES
This Class B digital apparatus complies with Canadian ICES-003.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
CORRECT DISPOSAL OF THIS PRODUCT
This marking indicates that this product should not be disposed with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.
Customer Support
www.blustream-us.com
www.blustream.com.au
www.blustream.co.uk
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>