FOLODA ME83 Heating Thermostat User Manual

June 22, 2024
FOLODA

FOLODA ME83 Heating Thermostat

ME83 Heating Thermostat Manual

Application
The thermostat is recommended for control of electric heating devices or on/off valve actuator used in water-based system.

User Operation

  • Power Key: Press the On / Off key to turn the system on or off.
  • M Mode Key: You can select “period control mode” or “manual mode” by this key.
  • Δ ∇ Up / Down key: Press the Up and Down keys to set the temperature and adjust system parameters. And press Up and Down simultaneously and hold for 5 seconds to enter lock key function.
  • Clock key: You can adjust the time and the week by this key.
  • Manual mode: Set the temperature manually by this key.
  • Automatic mode: Adjust to the automatic mode, the thermostat will work cyclically by week programming.

Anti-frozen function

In the state of shutdown, the thermostat will turn on the heating device automatically When the room temperature is below 5°C. when the room temperature is above 7°C, the thermostat will turn off the heating device automatically.

Technical data

  1. Temperature sensor: NTC
  2. Temperature accuracy: ±1
  3. Power consumption: <170uW
  4. Voltage: Two sections of 1.5V battery (not included)
  5. Load current: 3A
  6. Temperature setting: 5-90°C
  7.  Protection Class: IP20

Programming: 6-event time and temperature

In the shutdown state, long press mode key and the clock key for 5 seconds to enter programming mode. you can switch parameters by mode key. After entering the programming mode, press mode key to adjust “hour”, then press mode key to adjust “minute”. Press the mode key again to adjust temperature.

  1.  Wake-up 2. Leave(am) 3. Return(am) 4. Leave (pm) 5. Return (pm) 6. SleepFOLODA-ME83-Heating-Thermostat- \(5\)

Advanced setting (qualified person preferred)

Press at the same time to enter the mode of advanced setting immediately when thermostat is turned off. The following seven functions can be chosen by ” M ” key.FOLODA-ME83-Heating-Thermostat- \(7\)

Mounting steps

  1. See figure 1, mounted on the wall with a pitch of 86mm screw expansion sleeve.
  2. See figure 2, open the surface shell and the bottom shell, according to the alignment direction, route the desired wire through the back of the case to the wire slot, and according to the actual situation to set aside about 20CM length.
  3. See figure 3, fix the bottom shell on the wall, terminal fixed wire, cover the bottom shell with the surface shell.FOLODA-ME83-Heating-Thermostat- \(8\)

Wiring diagram

  • NC: Normally Closed Interface (Boiler or Loading);
  • COM: Common Interface (Boiler or external power input);
  • NO: Normally Open Interface (Boiler or Loading);

Dimension

Icon description

FOLODA-ME83-Heating-Thermostat- \(11\)

Mounting Location Recommended

The heating thermostat should be mounted on the wall with air flowing freely around. Warning: The mounting location should not be influenced by other heat source (e.g., sunlight), air flow through doors& windows or temperature of outer wall.

Common failure handling

Failure Handling
No power on
  1. Check whether the battery is reversed.
  2. Check if the power button is working.

LCD display garbled| he shell is deformed after installation, can be reinstalled.
Display normal No output|

  1.  Check whether the wiring between the MPU and the power board is damaged.
  2. Check whether the null line of live line is connected wrong.

Remote failure| Check if the remote-control battery has enough power, if not replace the battery.
Temperature display error| Adjust the panel temperature display by the first option in the Advanced tab.

MK71C DIGITAL DISPLAY PROGRAMMING HEATING THERMOSTAT

Attention: THIS THERMOSTAT IS SUITABLE FOR GAS BOILER. The temperature controller is using microchip real-time detection room temperature and target temperature contrast, control the wall-mounted furnace start or stop work, has achieved the purpose of constant temperature control. Weekly cycle, you can set 6 periods of programming run, each period with the corresponding preset temperature. You can select Cycle control mode or Manual mode as required.

User normal operation

Key description:

FOLODA-ME83-Heating-Thermostat- \(19\)

Press Δ Plus key and ∇ Minus key simultaneously and hold for 5 seconds, the thermostat will be locked/ unlocked. when locked will display (Disappear means unlocked).

Display symbols

FOLODA-ME83-Heating-Thermostat- \(12\)

Press F programming key to enter programming mode. The following is the factory default state.

FOLODA-ME83-Heating-Thermostat- \(13\)

Advanced setting (qualified person preferred)

Press M mode key and F programming key at the same time to enter the mode of advanced setting immediately when thermostat is turned off. The following ten functions can be chosen by M mode key. And then press the , power key to exit and save the advanced settings.

Symbol| Setting|
---|---|---
1| ADJ| Temperature calibration| Adjust measured temperature
2| SEN| Sensor mode|

  • IN: built-in sensor
  • OUT: floor sensor
  • ALL: both sensor

3| LIT| Limitation temperature| Adjust limitation value, limitation range:5-60°C.
4| DIF| Switching differential| Adjust switching differential
5| LTP| Anti-frozen function| Turn on/off Anti-frozen function

6

| PRG| Kinds of periods of time mode|

  • 5+2 day mode
  • 6+1 day mode
  • 7 day mode

7

| RLE| Potential-free output and main power output in the same/different way| Change the present linkage way
8| DLY| Delay time of potential-free output| Change linkage delay time
9| HIT| Max temperature| Max limitation temperature setpoint: 95°C
10| FAC| Reset to factory setting| Press Δ __ and hold for 5s then all parameters will be reset.

Technical data

  • Voltage: 3*AAA dry batteries
  • Power consumption: 2W
  • Temperature setting range: 5-95°C
  • Temperature limitation range: 5-60°C (factory setting: 35°C)
  • Switching differential: 1-10°Cadjustable, factory setting ±l°C
  • Ambient temperature: -5-50°C
  • Protective housing: IP20
  • Housing material: anti-flammable PC
  • Dimensions(H/W/D): 86/86/13mm

Common failure handling

Failure Handling
Crash
  1. Check the power supply wiring is correct or not.
  2. Check the power key.

LCD display garbled| The shell is deformed after installation, can be reinstalled.
Display  normal No output|

  1. Check whether the wiring between the MPU and the power board is damaged.
  2. Check whether the null line or live line is connected wrong.

Remote failure| Check if the remote-control battery has enough power, if not replace the battery.
Temperature display error| Adjust the panel temperature display by the first option in the Advanced tab.

Sensor failure

  • Please select the right sensor mode when operation, it will display “Er” symbol for sensor failure, thermostat must be checked till the fault is eliminated.
  • ErO: Built-in sensor disconnected or fault with it.
  • Erl : External sensor disconnected or fault with it.

Warranty and after-sales service

Since the date of products sold for 2 years warranty. In the warranty period, such as human factors or irresistible damage caused by power failure is not covered by the warranty, beyond the warranty period or damage caused by human factors, need to return to the maintenance company, as the case charged a certain maintenance fee.

Wiring diagram

  • NC: Normally Closed Interface (Boiler or Loading);
  • COM: Common Interface (Boiler or external power input);
  • NO: Normally Open Interface (Boiler or Loading);
  • Note: As a part of circuit of this product involve high voltage, must be installed by professional.

Mounting steps

  1. See figure 1, mounted on the wall with a pitch of 86mm screw expansion sleeve.
  2.  See figure 2, open the surface shell and the bottom shell, according to the alignment direction, route the desired wire through the back of the case to the wire slot, and according to the actual situation to set aside about 20CM length.
  3.  See figure 3, fix the bottom shell on the wall, terminal fixed wire, cover the bottom shell with the surface shell.

Icon display description

FOLODA-ME83-Heating-Thermostat- \(18\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals