Rowenta LY4000F0 Body Sculpt Massager User Manual

June 3, 2024
Rowenta

Rowenta LY4000F0 Body Sculpt Massager

DESCRIPTION

Rowenta-LY4000F0-Body-Sculpt-Massager-fig-1--
1

  1. Body massager device
  2. Accessory connector
  3. On/Off button
  4. Battery indicator
  5. Massage level indicator (1 = Low | 2 = High)
  6. Anti-slippery handle
  7. Charging pin cover
  8. Charging pin
  9. Massaging silicon wheels
  10. Charging cable

SAFETY INSTRUCTIONS

For your safety, this appliance complies with the applicable standards and regulations (Low Voltage Directive, Electromagnetic Compatibility, Environmental…).
As an additional safety measure, we recommend the installation of a residual current difference device in the electrical circuit supplying the bathroom, acting at not more than 30 mA. Ask your installer for advice. For countries subject to EU regulations (CE marking): This device can’t be used by children. This appliance can be used by persons with impaired physical, sensory or mental abilities, or lacking experience or knowledge, if they are properly supervised or if they have received instructions concerning how to safely use the appliance and if they have understood the risks involved. Children should not be allowed to play with the appliance. Children should not clean or perform maintenance procedures on the appliance. The battery must be removed from the appliance before it is scrapped. The appliance must be disconnected from the supply mains when removing the battery. The battery is to be disposed of safely. For other countries not subject to EU regulations: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. This appliance contains batteries that are only replaceable by skilled people. Your device should be used only for domestic use. It could not be used for professional purpose. Warranty become null and void if used wrongly. Only the device is suitable for cleaning under an open water tap. Detach the hand-held part from the supply cord before cleaning it in water. Do not charge the device near water and outdoors and never immerse into liquids or wet the charger. Please select a dry location. Never use the dishwasher to clean your device. Please do not use corrosive products for cleaning (alcohol, vinegar…) Massager only, with its massage head, can be used in bath or shower. Before any use, please ensure that the product and accessories have any defect. If your device is damaged or shows any defect, don’t use it anymore. If your appliance fall down and works abnormally after, don’t use it and contact after sales service. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

Detachable supply unit
WARNING: For the purpose of recharging the battery, only use the supply unit and base 1002 provided with this appliance. For an optimal charge, the device should be correctly inserted into the base. Make sure your appliance is in accordance with the supply network of your country. Don’t unplug the cord by cord pulling but by plug pulling. Don’t use Electrical extension cord.

FORBIDDEN USE

When the device is on, it must not come into contact with eyelashes, hair, clothing, or any other object, in order to avoid any risk of injury or blockage of the device.
Do not use on head and hair must be worn in such a way that they cannot become entangled in moving parts. In order to avoid irritation, be careful to not use any other exfoliating and aggressive products such as scrubs, alcohol, clay… This appliance is a skincare appliance, not a medical device. If you are on medication or if you suffer from medical problems, please contact your doctor before using our appliance. Make sure to use the device only on your body, not on eyes or face. Always use the device in motion on your skin.
Do not use the appliance:

  • With homemade cosmetics, essential oils, medical creams and corrosive products
  • on damaged and sun burned skin
  • on unhealthy skin
  • on areas which may present a health hazard (varicose veins, moles, birthmarks)
  • if you suffer from skin conditions and diseases such as eczema, inflammation…
  • If you are allergic to some metals (nickel)
  • If you take steroids or photosensitive substances
  • If you are pregnant*
  • Our product has not been tested under these conditions, ask for medical advice. Please stop using the appliance in case of allergy, irritation, redness, or if you feel pain or any signs of discomfort. If you wear piercings on the areas to be treated, please take them off before using the device. Take care to not use the device next to those areas. If you wear jewelry near treated areas, remove it before use.

CLEANING – MAINTENANCE – STORAGE – TRANSPORT

After charging, remember to close the power connector cover. Massaging silicon wheels can be removed from the device and should be rinsed under lukewarm water.

BEFORE FIRST USE

You have purchased the Rowenta Body Sculpt Massager. This device was designed to enhance your silhouette and reduce cellulite. This device provides an effective massage that reduces dimpling and firms the skin in the thighs, buttocks, belly, and arms areas. It has a set of 4 wheels that perform a rotational movement (2 speeds). Massage helps to naturally de-stock the fat that causes cellulite, for smoother skin and a refined silhouette. Before first use, fully charge the battery.

USING THE APPLIANCE

  • Apply your anti-cellulite skincare product
  • Switch on the device by pressing the “power” button. Start with speed 1 and increase it according to your sensitivity to the massage.
  • Hold the massager firmly and move it with circular movements (refer to the pictograms below). We recommend a use 5 min per area (thighs, buttocks, belly and arms) daily for 1 month, then one maintenance session per week the following months.
  • Your device is waterproof and can be used underwater.
  • We recommend recharging your device after each use

IN CASE OF ANY ISSUE

Your device shuts down during use:

  • Check that the battery charge level is sufficient.
  • Check that you do not apply too much pressure to the skin in use. For safety reasons, the device is fitted to stop the device if the pressure is too high for too long. The product should restart automatically when the pressure is released.

For any other reason, return your device to a service center.

ENVIRONMENT PROTECTION FIRST

Your appliance contains valuable materials which can be recovered or recycled. Leave it at a local civic waste collection point. Recycling the batteries: Before removing the LI-ION batteries, discharge them completely. Open the battery compartment using a tool, cut all the connections and then recycle the batteries in a safe manner. Those instructions are also available on our website www.rowenta.com

  • Ref. : 1002

  • Groupe SEB – Rue du Champ de courses 38780 Pt Evêque – France

  • 421 266 271 R.C.S. Lyon

  • INPUT : 100-240V 50/60Hz

  • OUTPUT : 10.0V 1.5A 15W

  • A.A.E.: 84,5%

  • E.L.L. (10%): 81.5%

  • No load: 0,06W

Documents / Resources

| Rowenta LY4000F0 Body Sculpt Massager [pdf] User Manual
LY4000F0 Body Sculpt Massager, LY4000F0, Body Sculpt Massager, Sculpt Massager, Massager
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Rowenta User Manuals

Related Manuals