ELATION KL FRESNEL 4 CW User Manual
- June 7, 2024
- ELATION
Table of Contents
- GENERAL INFORMATION
- LIMITED WARRANTY (USA ONLY)
- SAFETY GUIDELINES
- MAINTENANCE GUIDELINES
- FIXTURE OVERVIEW
- INSTALLATION INSTRUCTIONS
- CLAMP INSTALLATION
- SYSTEM MENU
- MANUAL DIMMING CONTROL
- DMX CHANNEL FUNCTIONS AND VALUES
- SPECIFICATIONS
- DIMENSIONAL DRAWINGS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELATION KL FRESNEL 4 CW User Manual
©2021 ELATION PROFESSIONAL all rights reserved. Information,
specifications, diagrams, images, and instructions herein are subject to
change without notice. ELATION PROFESSIONAL logo and identifying product names
and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright
protection claimed includes all forms and matters of copyrightable materials
and information now allowed by statutory or judicial law or hereinafter
granted. Product names used in this document may be trademarks or registered
trademarks of their respective companies and are hereby acknowledged. All non-
ELATION brands and product names are trademarks or registered trademarks of
their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and
all liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com |
info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The
Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax |
www.elationlighting.eu |
info@elationlighting.eu
Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma,
Lerma, Mexico 52000
+52728-282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of
this document may be available online. Please visit
https://www.elationlighting.eu/en for the latest revision/update of this
manual, before installation and/or programming.
__
Date
| __
Document Version
| __
Software Version ≥
| DMX
Channel Modes
| __
Notes
---|---|---|---|---
03/02/19| 1.0| 1.03| 1 / 2 / 3 / 4 / 5| Initial release.
10/02/20| 1.1| N/C| NO CHANGE| Updated box contents
10/08/20| 1.2| N/C| NO CHANGE| Updated refresh frequency
10/21/20| 1.3| N/C| NO CHANGE| Updated specifications
05/26/21| 1.4| N/C| NO CHANGE| Added Standalone instructions to System Menu
section
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and
thoroughly before attempting to operate this device. These instructions
contain important safety and use information.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton is damaged, carefully inspect the
device for damage, and be sure all accessories necessary to install and
operate the device have arrived intact. In the event damage has been found or
parts are missing, please contact our customer support team for further
instructions. Please do not return this device to your dealer without first
contacting customer support. Please do not discard the shipping carton in the
trash. Please recycle whenever possible.
BOX CONTENTS
Barn Door
Gel Frame
Barn Door Safety Cable (USA Only)
CUSTOMER SUPPORT
Contact ELATION Service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments or suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET +31 45 546 85 63 |
Fax +31 45 546 85 96 |
support@elationlighting.eu
REPLACEMENT PARTS please visit
parts.elationlighting.com
IMPORTANT NOTICE!
LIMITED WARRANTY (USA ONLY)
A. Elation Professional hereby warrants, to the original purchaser, Elation
Professional products to be free of manufacturing defects in material and
workmanship for a period of two years (730 days), and Elation Professional
product rechargeable batteries to be free of manufacturing defects in material
and workmanship for a period of six months (180 days), from the original date
of purchase. This warranty excludes discharge lamps and all product
accessories. This warranty shall be valid only if the product is purchased
within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by
acceptable evidence, at the time service is sought. B. For warranty service,
send the product only to the Elation Professional factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts
replacement) are within the terms of this warranty, Elation Professional will
pay return shipping charges only to a designated point within the United
States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any
accessories are shipped with the product, Elation Professional shall have no
liability what so ever for loss and/or or damage to any such accessories, nor
for the safe return thereof. C. This warranty is void if the product serial
number and/or labels are altered or removed; if the product is modified in any
manner which Elation Professional concludes, after inspection, affects the
reliability of the product; if the product has been repaired or serviced by
anyone other than the Elation Professional factory unless prior written
authorization was issued to purchaser by Elation Professional; if the product
is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual. D. This is not a service
contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation Professional
will replace defective parts at its expense, and will absorb all expenses for
warranty service and repair labor by reason of defects in material or
workmanship. The sole responsibility of Elation Professional under this
warranty shall be limited to the repair of the product, or replacement
thereof, including parts, at the sole discretion of Elation Professional. All
products covered by this warranty were manufactured after January 1, 1990, and
bare identifying marks to that effect. E. Elation Professional reserves the
right to make changes in design and/or performance improvements upon its
products without any obligation to include these changes in any products
theretofore manufactured. F.
No warranty, whether expressed or implied, is given or made with respect to
any accessory supplied with the products described above. Except to the extent
prohibited by applicable law, all implied warranties made by Elation
Professional in connection with this product, including warranties of
merchantability or fitness, are limited in duration to the warranty periods
set forth above. And no warranties, whether expressed or implied, including
warranties of merchantability or fitness, shall apply to this product after
said periods have expired. The consumer’s and/or dealer’s sole remedy shall be
such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional be liable for any loss and/or damage,
direct and/or consequential, arising out of the use of, and/or the inability
to use, this product. G. This warranty is the only written warranty applicable
to Elation Professional products and supersedes all prior warranties and
written descriptions of warranty terms and conditions heretofore published.
WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre-
paid and accompany a return authorization (R.A.) number. The R.A. number must
be clearly written on the outside of the return package. A brief description
of the problem as well as the R.A. number must also be written down on a piece
of paper and included in the shipping container. If the unit is under
warranty, you must provide a copy of your proof of purchase invoice. Items
returned without a R.A. number clearly marked on the outside of the package
will be refused and returned at customer’s expense. You may obtain a R.A.
number by contacting customer support.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts (omega brackets) included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufactures warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES
WARRANTY. DAMAGES RESULTING FROMMODIFICATIONS TO THIS FIXTURE AND/OR THE
DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE
MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR
REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE! UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK – MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and
allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating
fixture.
DO NOT operate fixture if the power cord is frayed, crimped, damaged
and/or if any of the power cord connectors are damaged and do not insert into
the fixture securely with ease.
NEVER force a power cord connector into the fixture. If the power cord or
any of its connectors are damaged, replace it immediately with a new one of
similar power rating.
DO NOT block any air ventilation slots.
All fan and air inlets must remain clean and never blocked.
Allow approx. 6” (15cm) between fixture and other devices or a wall for proper
cooling.
When installing fixture in a suspended environment, always use mounting
hardware that is no less than M10 x 25 mm, and always install fixture with an
appropriately rated safety cable.
Always disconnect fixture from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug end,
never pull out the plug by tugging the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit
from the interior of the fixture. This is a normal process and is caused by
excess paint in the interior of the casing burning off from the heat
associated with the lamp and will decrease gradually over time.
Consistent operational breaks will ensure fixture will function properly for
many years.
ONLY use the original packaging and materials to transport the fixture in
for service.
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light
output, and an extended life. The frequency of cleaning depends on the
environment in which the fixture operates: damp, smoky or particularly dirty
environments can cause greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface at least every 20 days with a soft cloth to
avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended
life.
There are no user serviceable parts inside this fixture, please refer all
other service issues to an authorized Elation service technician. Should you
need any spare parts, please order genuine parts from your local Elation
dealer.
Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three
months, to make sure the circuit contacts are in good condition and prevent
overheating.
Be sure all screws and fasteners are securely tightened at all times. Lose
screws may fall out during normal operation resulting in damage or injury as
larger parts could fall.
Check for any deformations on the housing, color lenses, rigging hardware and
rigging points (ceiling, suspension, trussing). Deformations in the housing
could allow for dust to enter into the fixture. Damaged rigging points or
unsecured rigging could cause the fixture to fall and seriously injure a
person(s).
Electric power supply cables must not show any damage, material fatigue or
sediments.
NEVER remove the ground prong from the power cable.
FIXTURE OVERVIEW
- Power Out
- Power in
- 5pin DMX In
- 5pin DMX Out
- USB Software Update Port
- OLED Control Menu Display
- MODE Button
- UP Button
- DOWN Button
- ENTER Button
- Manual Dimming Control Knob
- Fuse
- Manual Zoom Control Knob
INSTALLATION INSTRUCTIONS
FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or
pyrotechnics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or
installations.
USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION
OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE. CHECK
SILK SCREEN FOR MAX AMPS.
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.
Before rigging/mounting a single fixture or multiple interconnected fixtures for custom matrix designs to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories.
Fixture ambient operating temperature range is 14° to 113°F. (-10° to 45°C)
Do not use the fixture under or above this temperature.
Fixture(s) should be installed in areas outside walking paths, seating areas, or away from areas were unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing or
servicing.
Overhead fixture installation must always be secured with a secondary safety
attachment, such as an appropriately rated safety cable that meets all local,
national, and country codes and regulations. Allow approximately 15 minutes
for the fixture to cool down before serving.
GEL FRAME AND BARN DOOR INSTALLATION
The fixture has 2 slots on the front to hold the GEL FRAME and BARN DOOR. The
first smaller slot is for the GEL FRAME and the second larger slot is for the
BARN DOOR.
The fixture also has a top lock that secures these accessories to the fixture.
Secure the included mini SAFETY CABLE to the BARN DOOR and the top lock.
- Lift up lock on top of fixture and insert GEL FRAME into the first slot closest to fixture.
- Insert BARN DOOR into the second slot.
- Lower the lock on top of the fixture to secure both the GEL FRAME and BARN DOOR.
- Secure the included mini SAFETY CABLE to the BARN DOOR and top lock.
CLAMP INSTALLATION
When mounting the fixture to truss, be sure to secure an appropriately rated professional grade rigging clamp to the fixture using an M10 screw fitted through one of the 3 holes of the yoke bracket. The fixture provides a built- in rigging point for a SAFETY CABLE. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle.
RIGGING
Overhead rigging requires extensive experience, including amongst others
calculating working load limits, installation material being used, and
periodic safety inspection of all installation material and the fixture. If
you lack these qualifications, do not attempt the installation yourself.
Improper installation can result in bodily injury. Fixture is fully
operational in the specific mounting positions illustrated below.
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED
ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS
SYSTEM MENU
The fixture includes an easy to navigate system menu. The control panel (see image below) located on the side of the fixture provides access to the main system menu and is where all necessary system adjustments are made to the fixture. During normal operation, pressing MODE button once will access the fixture’s main menu. Once in the main menu you can navigate through the different functions and access the sub-menus with the UP and DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm your setting. You may exit the main menu at any time without making any adjustments by pressing the MODE button.
NOTE: To access the LCD Menu Control Display when locked, press and hold the MODE button for 3 seconds. The LCD Menu Control Display will shut OFF automatically about 1 minute from the last button press.
STANDALONE
Press the MODE button to access the fixture’s main menu. Use the UP
and DOWN buttons to navigate to DMX Settings and press the ENTER
button.
Navigate to No DMX Status and press the ENTER button. Navigate to
Standalone and press the ENTER button
ELATION KL FRESNEL 4 CW S Y S T E M M E N U
Supports Software Versions: ≥ 1.03
Features subject to change without notice.
MAIN MENU| SUB MENU| OPTIONS / VALUES (Default
Settings in BOLD )| DESCRIPTION
Address| Address| 001 ~ XXX| Set DMX Address Setting
UserMode| User Mode| Dimmer / Dimmer 16bit / 3CH / Standard /
Extended| Set DMX Channel / User Mode
Function
| Status| Lost Dmx| Hold / Black| Function If NO DMX Detected
LCD. Set
|
Display
|
ON / OFF
| OLED Display Screen Saver Mode
*When ON goes off after 30 seconds.
ONLY WHEN DMX IS CONNECTED.
Key Lock| ON / OFF| Control Front Panel Buttons Key Lock
Flash| ON / OFF| Display flashes when NO DMX
Invert| ON / OFF| Flip LCD Display 180º
Temp. C/F| C / F| Temperature Switch Between C˚/ F˚
Dim Mode
| Standard , Stage, TV, Architec, Theatre. Stage2, 0.0s, 0.1s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, 0.7s, 0.8s, 0.9s, 1.0s,
1.5s, 2.0s, 3.0s, 4.0s, 5.0s, 6.0s, 7.0s, 8.0s, 9.0s, 10.0s
|
Set Dimmer Mode
Disp. Set| ADDR , Disp.CH, Salve| Set Information to Display on LCD
Fan. Set| Led Fan| Auto / High / Low| Set LED Fan Speed
Dim Curve| Linear / Square / INV-Square / S-Curve| Set Dimmer Curve
Mode
Frequen
| 900kHz, 1000kHz, 1100kHz, 1200kHz , 1300kHz, 1400kHz,
1500kHz, 2500kHz, 4000kHz, 5000kHz, 10kHz, 15kHz, 20kHz,
25kHz
|
Set LED Refresh Frequency
USB_Data| ON, OFF| Software Update Port – Contact Service
MasterSW| ON, OFF|
DFSE| ON, OFF| Restore Factory Settings
Info
|
TimeInfo
| Current| 000 (Hours)| Fixture Run Time From Power ON
Total| 000 (Hours)| Fixture Total Run Time
Last| 000 (Hours)| Clear Fixture Last Run Time
Password| PIN= 050| Enter PIN to Access Clear Last. Menu
Clear| ON / OFF| Reset Fixture Last Run Time
TempInfo| Led Temp| 000 C / F| Temperature of LED
Err. Info| Error Record 1 ~ Error Record 10| Display 10 Recent Error Messages
ModelInf| KL F4 CW| Display Model Name
Software| Software| V1.03| Software Version (Greater than or Equal to)
Test| ManCtrl| Dimmer| 000 – 255| Manual Control Functions
DIMMER CURVE MODES – Dim Curve
Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre, Stage2).
MANUAL DIMMING CONTROL
FEATURE IS DISABLED WHEN DMX INPUT CABLE IS CONNECTED TO FIXTURE!
TO USE MANUAL DIMMING KNOB, DISCONNECT DMX CABLE IF CONNECTED.
Follow steps below to enable manual DIMMING control knob.
- Access fixture system menu navigating to Test menu then access ManCtrl sub menu.
Test
| Reset.M| Zoom| Reset Zoom Motor
---|---|---|---
Calibrat| PassWord| Password= 050| Calibrate Zoom Motor
(PSWD Required to Access)
Zoom| 000-255
ManCtrl| Dimmer, Zoom, Strobe| Manual Control Functions
NOTE: To access the LCD Menu Control Display when locked/OFF, press and hold the MODE button for 3 seconds.
2. Select Stobe menu, set to value of 255 (LED ON), then exit fixture
system menu.
3. Push DIMMING knob to unlock, rotate to desired level, push knob
again to lock.
Repeat this process each time a dimmer adjustment is desired.
DMX CABLE CONNECTED
NO DMX CABLE CONNECTED
DMX CHANNEL FUNCTIONS AND VALUES
ELATION KL FRESNEL 4 CW
DMX Channel Values / Functions (5 DMX Channels)
Supports Software Versions: ≥ 1.03
Features subject to change without notice.
MODE / CHANNEL| __
VALUE
| __
FUNCTION
Dimmer| Dimmer 16bit| 3CH| Standard|
Extended
1| 1| 1| 1| 1| | DIMMER INTENSITY
000-255| Dimmer 0 to 100%
| 2| | 2| 2| | DIMMER INTENSITY FINE
000-255| Dimmer FINE Adjustment
| | __
__
__
__
__
2
| __
__
__
__
__
3
| __
__
__
__
__
3
| | SHUTTER | STROBE
000-031| LED OFF
032-063| LED ON
064-095| Strobe Effect SLOW to FAST
096-127| LED ON
128-159| Pulse Effect In SLOW to FAST
160-191| LED ON
192-223| Random Strobe Effect SLOW to FAST
224-255| LED ON
| | __
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
3
| __
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
4
| __
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
__
4
| | DIMMER MODES | DIMMER DELAY TIMES
000-020| Standard
021-040| Stage
041-060| TV
061-080| Architectural
081-100| Theatre
101-120| Stage 2
121| Dimmer Delay Time 0.0 seconds
122| Dimmer Delay Time 0.1 seconds
123| Dimmer Delay Time 0.2 seconds
124| Dimmer Delay Time 0.3 seconds
125| Dimmer Delay Time 0.4 seconds
126| Dimmer Delay Time 0.5 seconds
127| Dimmer Delay Time 0.6 seconds
128| Dimmer Delay Time 0.7 seconds
129| Dimmer Delay Time 0.8 seconds
130| Dimmer Delay Time 0.9 seconds
131| Dimmer Delay Time 1.0 seconds
132| Dimmer Delay Time 1.5 seconds
133| Dimmer Delay Time 2.0 seconds
134| Dimmer Delay Time 3.0 seconds
135| Dimmer Delay Time 4.0 seconds
136| Dimmer Delay Time 5.0 seconds
137| Dimmer Delay Time 6.0 seconds
138| Dimmer Delay Time 7.0 seconds
139| Dimmer Delay Time 8.0 seconds
140| Dimmer Delay Time 9.0 seconds
141| Dimmer Delay Time 10.0 seconds
142-255| Default
MODE / CHANNEL| __
VALUE
| __
FUNCTION
---|---|---
Dimmer| Dimmer 16bit| 3CH| Standard|
Extended
| | | | __
__
__
__
__
__
__
__
__
__
__
__
__
5
| | LED REFRESH RATE | DIMMER CURVES*
*Hold selected DMX value for 5 seconds to set LED Refresh Rate.
000-100| IDLE
101-105| 900 kHz
106-110| 1000 kHz
111-115| 1100 kHz
116-120| 1200 kHz
121-125| 1300 kHz
126-130| 1400 kHz
131-135| 1500 kHz
136-140| 2500 kHz
141-145| 4000 kHz
146-150| 5000 kHz
151-155| 10,000 kHz
156-160| 15,000 kHz
161-165| 20,000 kHz
166-170| 25,000 kHz
171-200| IDLE
201-210| DIMMER CURVE LINEAR (DEFAULT)
211-220| DIMMER CURVE SQUARE
221-230| DIMMER CURVE INVERSE SQUARE
231-240| DIMMER CURVE S-CURVE
241-255| IDLE
SPECIFICATIONS
SOURCE
50W Cool White LED Engine 5,600K, 97CRI
50,000 Hour Average LED Life
May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling),
Control, and Dimming.
PHOTOMETRIC DATA
2300+ Total Lumen Output
3,753 LUX 349 FC @ 9.8’ (3m) (Min. Zoom)
814 LUX 76 FC @ 9.8’ (3m) (Max. Zoom)
Zoom Range 14° – 33°
Beam Angle 14° – 32.9°
Field Angle 22.1° – 51.7°
EFFECTS
Manual Zoom
Electronic Dimmer and Strobe
Variable 16-bit Dimming Modes and Curves
COLOR
5,600K Cool White LED
CONTROL / CONNECTIONS
Manual and DMX Controlled Dimmer and Shutter
Dimmer Rotary Dial
(5) DMX Channel Modes (1 / 2 / 3 / 4 / 5)
4 Button Control Panel LCD Menu Display
RDM (Remote Device Management)
5pin DMX and IP65 Locking Cable In/Out
With Wired Digital Communication Network
SIZE / WEIGHT
Length: 9.9” (251mm)
Width: 7.9” (201mm)
Vertical Height: 11.4” (289mm)
Weight: 9.0 lbs. (4.08 kg)
ELECTRICAL / THERMAL
AC 100-240V – 50/60Hz
50W Max Power Consumption
5°F to 113°F (-15°C to 45°C)
Power Linking: 12Pcs @ 110V / 27Pcs @240V
INCLUDED ITEMS
Gel Frame and Rotating Barn Doors
IP65 Locking Power Cable
Barndoor safety cable (USA Only)
APPROVALS / RATINGS
CE | cETLus | IP30
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part
15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
device uses and can radiate radio frequency energy and, if not installed and
used in accordance with the included instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this device does cause harmful interference to
radio or television reception, which can be determined by turning the device
off and on, the user is encouraged to try to correct the interference by one
or more of the following methods:
- Reorient or relocate the device.
- Increase the separation between the device and the receiver.
- Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
DIMENSIONAL DRAWINGS
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
References
- WorldSite ist nun VIVANET
- Topics | Elation Lighting Forums
- Elation Professional EUROPE - Professional Lighting Products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>